| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.0 LAccepted-Finance | L1 | Accepted-Finance OK | |
| 2 | L2₹19.8 L+₹87,487 (4.61%)Accepted-Finance | L2 | Accepted-Finance OK |
Tender Value
₹19.1 L
Closing Date
22 Sept 2021, 3:00 pmClosed
Executive Engineer (E) P
517, Fifth Floor, T.E. Building Lodhi Road, 9 CGO Complex, MTNL, New Delhi
Essential work for AC units at various TE Bldgs/different sites under EE (E)P, at TE building Lodhi Road, MTNL, New Delhi
2021_MTNL_647624_2
EE(E)P/2021-22/20
Open Tender
Electrical Works
Item Rate
180 days
NEW DELHI
Please refer Tender documents.
7 documents required · 7 mandatory
₹590
MTNL ,Delhi
Exempted
3 Dec 2021
15 Sept 2021
23 Sept 2021
15 Sept 2021
22 Sept 2021
15 Sept 2021
Amount
Providing and installing following size soft/hard copper pipe including cutting, bending, jointing, brazing etc as reqd. for hot and liquid refrigerant line complete as required as per site requirement. a) 7/8" or 6/8"
Fabricating & installing of following size copper piping/cable tray made out with M.S slotted angle/factory fabricated tray i/c nut bolt, screw, etc as reqd. width size not exceeding 150mm
Pdg & fixing kini foam 3mm thick for thermal insulation of copper pipping in order to protect it from airborn impurities i/c removal of old insulation etc. complete as reqd
Supplying, laying and fixing of following sizes pvc sheathed copper conductor armoured / unarmoured cable on the existing wall / ceiling for power / control cable etc making connections and testing etc complete as reqd as per site location. a) 4 x 10 sq. mm copper armoured cable.
b) 4 x 6 Sq. mm copper armoured cable.
c) 4 x 1.5 Sq. mm copper armoured cable.
d) 3 x 2.5 Sq. mm copper armoured cable.
e) 17 core unarmoured cable.
f) 3 core 2.5 Sq.mm flexible copper cable.
Replacement of the following defective / unserviceable faulty components of 1.5 TR / 2 TR AC units with the new ones complete as required as per the site location. a) Outdoor condenser motor.
b) Indoor unit motor.
c) Indoor blower.
d) Fan Blade.
e) Starting Capacitor (80-120 Mfd)
f) Running Capacitor (45-50 Mfd)
g) Capacitor (6/50Mfd)
Charging of R-22 refrigerant gas in the existing package/ ductable/ sensicool/ tower/ cassette/ split/ window AC unit after purging the air, testing and commissioning the units etc. complete as reqd. a) 1.5 TR / 2.0 TR (nominal capacity) AC unit.
b) 2.5 TR / 3.0 TR (nominal capacity) AC unit.
c) 4.0 TR / 5.0TR / 5.5 TR (nominal capacity) AC unit.
d) 8.5 TR / 9.0 TR (nominal capacity) AC unit (each Circuit).
e) 11.0 TR / 12 TR (nominal capacity) AC unit (each Circuit).
f) 7.0 TR / 7.5 TR (nominal capacity) AC unit (each Circuit).
Supplying and fixing following new condenser coils including dismantling the existing condensor coil and making proper size copper pipe connection, brazing at joints etc as reqd. a) Condenser coil for 1.5 TR / 2 TR (nominal capacity) AC unit.
b) Condenser coil for 2.5 TR / 3.0 TR (nominal capacity) AC unit.
c) Condenser coil for 4 TR / 5 TR / 5.5 TR (nominal capacity) AC unit.
d) Condenser coil for 7.0 TR / 7.5 TR (nominal capacity) AC unit.
e)Condenser coil for 8.5TR /9 TR (nominal capacity) AC unit.
f) Condenser coil for 11.0 TR (nominal capacity) AC unit.
Pdg. & fixing of electrical/switchgears used for AC plant/centifugal fan/air washer & other works complete as reqd. a) 63amp TPN SFU/MCCB/MCB
b) 100amp TP MCCB
Providing and making MS structure work such as MS platform/duct supports /tray supports/frame for indoor and outdoor AC units i/c cutting, welding, painting with redoxide and then enamel oil paint of approved color etc. complete as reqd. as per site location.
Replacement of faulty compressor with the factory repaired compressor i/c dismantling of the faulty one from site and re-fixing the new one etc as reqd. a) 1.5 TR.
Pdg. & fixing automatic Phase correction system for ductable A C unit which should work in such a way that as the series of phases changed from the 3 phase A C supply it will work and make the series phase correct so that the A C units operation does not effect i/c its wiring etc complete as reqd.
Pressure testing with nitrogen, vaccumizing & checking of leakage, commissioning of existing package/ ductable/ sensicool/ tower/ cassette/ split/ window AC unit etc. complete as required. a) 1.5 TR / 2.0 TR (nominal capacity) AC unit.
b) 2.5 TR / 3.0 TR (nominal capacity) AC unit.
c) 4.0 TR / 5.0TR / 5.5 TR (nominal capacity) AC unit.
d) 8.0 TR / 8.5 TR / 9.0 TR (nominal capacity) AC unit (each Circuit).
e) 11.0 TR / 12 TR (nominal capacity) AC unit (each Circuit).
f) 7.0 TR / 7.5 TR (nominal capacity) AC unit (each Circuit).
Supplying and fixing new evaporator coils for following AC unit including dismantling the faulty existing evaporator coil and making proper size copper pipe connection, brazing at joints etc as reqd. a) Evaporator coil for 1.5 TR / 2 TR (nominal capacity) AC unit.
b) Evaporator coil for 2.5 TR / 3.0 TR (nominal capacity) AC unit.
c) Evaporator coil for 4 TR / 5 TR / 5.5 TR (nominal capacity) AC unit.
d) Evaporator coil for 7.0 TR / 7.5 TR (nominal capacity) AC unit.
e) Evaporator coil for 8.5 TR / 9.0 TR (nominal capacity) AC unit.
f) Evaporator coil for 11.0 TR (nominal capacity) AC unit.
Providing & making drain arrangement for AC units with following pipe i/c Tee, Union, Socket & Elbow etc as required. a) 40 mm dia medium class PVC pipe.
b) 25 mm diamedium class PVC pipe.
Providing and fixing of 6mm thick cross linked polyethylene insulation for drain / copper piping in order to protect it from air borne impurities complete as reqd. as per site location.
Minor civil work such as cutting, widening and opening the floor/wall and other civil work for installing refrigerant piping/drain piping/ ducting/electrical cabling for each cutout including finishing the same complete as reqd.
P/F PCB in the existing Ductable / Package AC units of 4/5/7.5 / 8.5/9/11.0 TR AC units i/c contactor and single phase preventor etc. complete as required.
Less credit for dismantled material and dismantled material shall be the property of contractor.
M/s Super Maintenace and Services
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .