| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.4 LAccepted-AOC 90 E B C ROAD KOLKATA 700034 | KOLKATA | KOLKATA | WEST BENGAL | 700034 | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹43.4 L+₹3.0 L (7.48%)Rejected-Finance 49 1 ISWAR GUPTA ROAD KOLKATA 700006 | KOLKATA | KOLKATA | WEST BENGAL | 700006 | L2 | Rejected-Finance 2nd lowest bidder | |
| 3 | L3₹50.1 L+₹9.7 L (24.0%)Rejected-Finance MASAT HARIPUR RD VILL P O HARIPUR HOOGHLY | HARIPUR | HOOGHLY | WEST BENGAL | 712701 | L3 | Rejected-Finance 3rd lowest bidder |
Tender Value
Refer Docs
EMD Value
₹1 L
Closing Date
14 Sept 2021, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE_I, Kol. South Health El. Divn.,P.W.Dte.
75 D H Road Kidderpore Kol_23
Electrical Installation Work regarding enhancement of COVID Critical Care beds to cope up with the upcoming 3rd wave at 1st floor and 2nd floor of Casualty Building of Sambhu Nath Pandit Hospital, Kolkata.
2021_WBPWD_341892_1
WBPWD/KSHED/Q35/21-22
Open Tender
ELECTRICAL WORKS ORG
Item Rate
15 days
Kolkata
Please refer Tender documents.
2 documents required · 2 mandatory
₹1 L
O/o Exe.Engr., Kol. South Health El. Divn., PWDte.
18 Nov 2021
27 Aug 2021
16 Sept 2021
27 Aug 2021
14 Sept 2021
2 Sept 2021
1 Sept 2021
120 days
Amount
Supply & Installation of floor cum wall mounted, cubicle type, indoor, compartmentalized, dust & moisture proof LT Distribution panel suitable for 415V., 50 Hz. AC system having IP-54 protection & fabricated out of 2 mm thick CRCA sheet steel & base frame having MS channel of section not less than ISMC 100mm x 50mm x 5mm and for operator safety, IP2X (touch proof) protection to be available even after opening the compartment door, with Continuous GI Earth bus of size 40 x 6 mm provided at a height of 150mm from the bottom and brought 75mm outside of the panel. Panel should have Cable alley spacious enough for maintenance & to be painted with RAL 7032 both inside and outside. (manufactured by CPRI approved Panel builder having CPRI Certification)
INCOMER:-
415V, 400A, 4 pole 36 kA (Uimp=8KV), Ics= 100% Icu MCCB with communicable microprocessor based release having adjustable O/L (0.4 to 1x In or better), Adjustable S/C (1/1.5 - 8/10 Ir), Inbuilt Instantenious protection, Adjustable E/F , Adjustable neutral protection at 50%, 100%, Both side spreader link, extended rotary handle etc. and castle interlock arrangement.
[Make :-ABB / Schneider / Legrand] Complete Set -- 2 Nos.
BUSBAR CHAMBER:-
S & F busbar made of 4 x 40 mm x 10 mm] of electrolytic tinned copper (99.9%) bar mounted on non-hygroscopic porcelain insulator / hylam sheet having sufficient di-electric strength duly wrapped with colour PVC tapes (Red, yellow, blue & black) for phases & neutral identification & all connection made with required size cu bars - 1set.
OUTGOING:-
a) 415V, 160A, 4 pole 36 kA (Uimp=8KV), Ics= 100% Icu MCCB with communicable microprocessor based release having adjustable O/L (0.4 to 1x In or better), Adjustable S/C (1/1.5 - 8/10 Ir), Inbuilt Instantenious protection, Adjustable E/F , Adjustable neutral protection at 50%, 100%, Both side spreader link, extended rotary handle etc.
[Make :- ABB/ Schneider/ Legrand] Complete Set ---1 No.
b) 415V, 125A, 4 pole 36 kA (Uimp=8KV), Ics= 100% Icu MCCB with communicable microprocessor based release having adjustable O/L (0.4 to 1x In or better), Adjustable S/C (1/1.5 - 8/10 Ir), Inbuilt Instantenious protection, Adjustable E/F , Adjustable neutral protection at 50%, 100%, Both side spreader link, extended rotary handle etc.
[Make :- ABB/ Schneider/ Legrand] Complete Set --- 3 Nos.
METTERING:-
8 Channel Touch Screen HMI for viewing Real time measurement data (V, A, KWH, PF, MD with date and time stamp), maintenance data (Operation count, Trip count, Trip History of at least 10 incident) and status of MCCB (on / off / trip) for all incoming and outgoing MCCBs - 1 No.
S & F cable supports of length 800 mm made from 50x50x6 mm MS angle, some portion of it properly inserted & grouted inside the wall & mending good the damages to original finish incl. S/F of 5 nos semicircular MS clamps made from 40x3 mm thick iron flat incl. nut, bolts & washers for rigidly holding the 5 nos 4 core 240/185 sqmm XLPE/Ar.Al cable and painting as per direction of the EIC.
Supply & Laying 1.1KV gr. 2 x 4 Core 185 mm² XLPE Ar./Al. Cable incl. making connections as per direction of E.I.C. as follows as to G.S. :- (For DG Panel) (Make: Havells / Polycab / Universal)
On existing Cable tray / MS angle support
In underground trench with brick protection
In GI protection pipe
In existing cable duct
Supply & Laying 1.1KV gr. 4 Core 70 mm² XLPE Ar./Al. Cable as per direction of E.I.C. as follows as to GS. :- (For VTPNDB)(Make: Havells / Polycab / Universal)
On wall surface by MS saddle.
On existing Cable tray / MS angle support.
Supply & Laying 1.1KV gr. 4 Core 25 mm² XLPE Ar./Al. Cable as per direction of E.I.C. as follows as to GS. :- (For PDB) (Make: Havells / Polycab / Universal)
On Wall Surface by MS saddle.
On prelaid cable tray
S & Fixing of compression type brass cable gland including end finishing of the following size cables :-
4 Core 185 mm² XLPE Ar./Al. Cable
4 Core 70 mm² XLPE Ar./Al. Cable
4 Core 25 mm² XLPE Ar./Al. Cable
S & F 8-Way Double Door vertical TPN MCB PDB comprising with 1 No. 415V, 125A 4-Pole MCCB (36 Ka), 2 Nos. 32 A TPMCB & 6 Nos. 63 A TP MCB (10KA, C CURVE), 2 nos. cable end boxes, DIN rail, N&E Bar, Spreader links, internal connections and other accessories, on wall with MS frame, including earthing attachment as per direction of EIC. (Make - Legrand / ABB Elegance / Schneider)
S & F 4-Way Double Door horizontal TPN MCB PDB comprising with 1 No. 415V, 63A. 4-Pole Isolator,12 nos. 250 V, 16-32 A. SP MCB (10KA, C CURVE), DIN rail, N&E Bar, internal connections and other accessories, on wall with MS frame, including earthing attachment as per direction of EIC. (Make - Legrand / ABB Elegance / Schneider)
S & F 2+14 Way Double Door SPN MCB BDB comprising with 1 No. 240V., 63A. DP Isolator, 14 nos. 6/16A. SP MCB (10KA, C CURVE), DIN rail, N & E Bar internal connections and other accessories, on wall with MS frame, including earthing attachment as per direction of EIC. (Make - Legrand / ABB Elegance / Schneider)
Distribution wiring in 1.1 KV grade 3 x 1.5 sq mm S/C stranded 'FR' PVC insulated & unsheathed copper wire (Finolex / Havells / Polycab ) in 20mm dia PVC Rigid conduit (Precision, MMS, FR) on wall to light/fan points with 6A Piano Key Switch (Anchor) fixed on 16 SWG sheet metal switch board complete with 3mm thick Bakelite top cover and 3 nos. suitable size cu connecting bars each on double bakelite insulation chairs including 175 x 100 x 65 mm MS inspection box on wall making earthing attachment & painting the MS box. [Avg. Run 8 Mtrs]
S & F 240V., 6A. 5 Pin Plug Socket without Top and Piano Key switch (Anchor) on Board as per direction of E.I.C.
S & F following sizes 16 SWG M.S. Box complete with 3mm thick Bakelite top cover, 3 nos. suitable size cu connecting bars (P,N, & E) each on double bakelite insulation chairs on wall with earthing attachment including S & F electrical accessories (All are Anchor Make) & making necesary connection as required.
250mm X 200mm X 65mm comprising with 1 No. 240 V 6 pin 20 A plug socket with 1No. 20 A piano key switch, 3 nos. 240V 6A 5 Pin plug socket with 3 nos. 6A Piano Key switch & 1 No. Indicator.
175mm X 125mm X 65mm comprising with 1 No. 240V 6 pin 20A plug socket with 1No. 20A piano key switch.
150mm X 100mm X 65mm comprising with 2 Nos. 240 V 5 pin 6A plug socket with 2 Nos. 6A piano key switch.
S & Drawing following sizes S/C stranded 'FRLS' PVC insulated & unsheathed copper wire (Make Finolex / Havells / Polycab) in PVC rigid conduit (Precision, MMS, FR) on wall as to G.S. :-
3 x 1.5 mm² in 20 mm dia PVC rigid conduit
2 x 2.5 & 1 x 1.5 mm² in 20 mm dia PVC rigid conduit
2 x 4 & 1 x 2.5 mm² in 20 mm dia PVC rigid conduit
2 x 6 & 1 x 4 mm² in 20 mm dia PVC rigid conduit
4 x 6 & 2 x 4 mm² in 25 mm dia PVC rigid conduit
Finishing the end of following sizes copper wire end with dowells solderless socket by crimping method as per GS :-
S & F 240 V, 1420 RPM, 300 mm. Dia A.C. Exhaust Fan (EPC Electrical Pvt. Ltd. - Heavy Duty) with Nuts, Bolts, washers etc. incl. Cutting hole on wall, S&F Louver Shutter (Aluminium) and mending good the damages to original finish.
S & F 18 Watt LED Tube lamp (Philips, Cat No. Master LED tube, 18W 865 T8 I 2100 lumens) in place of damaged tube light.
S & F 240V 36/34 watt recess mounted LED slim (2' x 2') light fittings complete with all accessories. [Make:-Wipro, Cat - CRCO 10 RO36 HP57 G2 / Philips, Cat No.RC380B LED36S-6500 G5 L60W60 PSU OD SG]
S & F 440 V. twin timer controlled starter assembled in S.S. enclosure of 6 way double door TPNDB comprising with 1 no 63A 4P MCB, 2 nos. 32A TP MCB, 2 nos. 32A TP power Contractor (Eq to MNX 40) , 2NO+2NC auxiliary contact, 1 no. 24 hrs. digital timer (Eq. to T2DDT7), 1 no Auto-Off-manual switch, 1 no 10A single way switch, 1 no. Indicating lamp & 1 no 6A SP MCB incl. front locking arrangement, internal wiring & earthing attachment as per direction of EIC. (Make - L&T /ABB / Legrand)
S & F 80 mm dia G.I. pipe (Tata / ISI Medium) to be laid in underground trench for cable protection as per GS.
S & Drawing 2 x 6 mm² S/C stranded 'FR' PVC insulated & unsheathed copper wire (Make Finolex / Havells / Polycab ) in 20mm dia PVC rigid conduit (Precision, MMS, FR) on prelaid tray for connecting the equipments to earth busbar as to G.S.
S & F Earth bus-bar of 25 mm x 6 mm GI flat on wall with drilled holes, double nut-bolts & washers etc. as to GS.
Earthing installation with 50mm dia, 3.04 m long G.I. pipe (ISI-M) for soft soil including excavation of earth & ramming properly as per G.S.
Cost of taken down LED tube light fittings, ceiling fans from the areas to be provided with AC duct / False ceiling & deposited to the safe place carefully as directed without any damage to the fixtures ( 280 nos).
Special Terms and Conditions 1. It is stated that the above work place is existing COVID Hospital and in some areas inside COVID ward. In case of any mishap or accidental to any staff that deputed by the agency the whole responsibility is to be borne by the concern agency. 2. The Agency shall be responsible for provisioning of all COVID safety measures including regular sanitization of work places, vaccination of employees and compliance of stated directive and COVID appropriate norms. 3. All the issues related to the safety of the staffs should be taken care by the agnecy itself.
Defect Liability period 1 (One) Year
Electromech Engineers Co-Operative Society Ltd.
GHANASHYAM ELECTRIC STORES
stage.html
html • 0.05 MB
technical_653617.pdf
PDF • 0.09 MB
techsummary_653617.pdf
PDF • 0.09 MB
finance_653617.pdf
PDF • 0.09 MB
BOQ Comparative Chart
xlsx • 0.01 MB
finsummary_653617.pdf
PDF • 0.09 MB
AOC_35.pdf
PDF • 0.36 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .