| 1 | L1₹13.9 LAccepted-AOC A 111 JHILMIL COLONY EAST DELHI 110095 | SHAHDARA | DELHI | 110095 | L1 | Accepted-AOC work order has been awarded | |
| 2 | L2₹15.4 L+₹1.5 L (10.6%)Rejected-Finance H 50 C SHAKARPUR DELHI 110092 | SHAHDARA | DELHI | 110092 | L2 | Rejected-Finance Not L1 |
Tender Value
₹16.6 L
EMD Value
₹33,259
Closing Date
9 Nov 2023, 1:00 pmClosed
EEE-I/SSZ
Office of the Executive Engineer (Elect)-I Room No.5 First Floor Vishwakarma Nagar Near Hanuman MandirJhilmil Colony Delhi-110095
Repair and Maintenance of Electrical installations and Fans in Community Hall under Electrical Division -I Shahdara (South) Zone Ward No.190 to 203
2023_MCD_172973_1
EEE-I/SSZ/2023-24/17.1
Open Tender
Electrical Works
Item Rate
365 days
work
Please refer to tender documents
4 documents required · 4 mandatory
₹590
₹33,259
29 Jan 2025
2 Nov 2023
10 Nov 2023
2 Nov 2023
9 Nov 2023
2 Nov 2023
Amount
OD11602/2023-2024:(1.17.3) Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3x1.5 sq.mm.
OD11604/2023-2024:(1.17.12) Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3x2.5 sq.mm.
OD11605/2023-2024:(1.17.30) Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3x6 sq.mm.
OD11606/2023-2024:(1.23.1)Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.5/6 amps switch
OD11607/2023-2024:(1.23.4)Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 3 pin 5/6 amp socket outlet
OD11608/2023-2024:(2.10.1) Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Single Pole)
OD11609/2023-2024:(2.12.1) Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 Amps
OD11610/2023-2024:(2.12.2) Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 Amps
OD11611/2023-2024:(19.1) Supply, installation, Testing and commissioning of 1200mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Currect (BLDC) Motor, class of insulation:B, 3 nos blades, 30 cm down rod, 2 nos. canopies, shackle kit, safety ropr, copper winding, power factor not less than 0.9, service value (CMM/W) minimum 6.00, Air delivery minimum 210 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C(max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, Earthng etc. complete as required.
OD11612/2023-2024:(2.2.1) Providing and fixing following capacity and braking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 100 A, 16 KA,TPMCCB MCCB
OD11613/2023-2024:(2.2.3) Providing and fixing following capacity and braking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 150 A, 25 KA,TPMCCB
OD11614/2023-2024:(7.7.1)Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)
OD11615/2023-2024:(1322) Supply of phenolic laminated sheet 3.00 mm thick ISI Marked as reqd.
Approved Rates
122.1.2:Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*6 sqmm
122.2.1:P/F Hot press sheet moulded compound (SMC) fire retardant (Temp. resistance up to 200 C), IP 55 weather proof pole box of inner dimension 300x200x105mm (NS) and outer dimension of 333X233X150 mm high dome complete with suitable arrangement for fixing of 4 nos of 6 to 32 amp single pole MCB & 63 Amp. Double pole isolator (MCB/Isolator excluded) with neutral link duly shorting on DIN Channel with2 Nos of MS clamps with SS back plate of suitable size with danger monogram property printed on the cover etc as reqd.
122.2.28:SITC of 60W LED Flood Light luminiare fitted with lens, made of pressure die cast aluminium housing & toughened glass cover complete with the following specification as reqd with IP 66 protection (a) Total system wattage =60 watt +/- 5% (b) Luminaire Efficacy>=100 Lm/w (c) Power Factor>=0.95 (d) Protection Class- IP-66
122.2.30.a:SITC of 150W LED Flood Light luminaire fitted with lens, made of pressure die cast aluminium housing & toughened glass cover complete with the following specification as reqd with IP 66 protection (a) Total system wattage =150 watt +/- 5% (b) Luminaire Efficacy>=100 Lm/w (c) Power Factor>=0.95 (d) Protection Class- IP-66
122.2.39:S/I/T/C of LED Tube type luminaire 20 Watt rating complete with polycarbonate housing batten integrated electronic driver prewired with high efficient LEDs with the following:(a) Total system wattage 20 watt +/- 5%(b )Luminous efficacy lumens/watt >=95 (c)Power Factor >=0.95
122.2.42:Repair/Rewinding of existing 1HP mono block pump set including replacement of parts like gun metal bush/ bearing condenser, impeller etc to make the pump functional as required.
OD11616/2023-2024:S/I/T/C of LED tube type luminaire 2x20 Watt rating Box Type complete with extruded Al.batten prewired with high efficient LEDs with the following : (A) Total System wattage= 40 watt +/- 5% (B) Luminous Efficiency Lumens/ watt >= 95 (C) Power factor ≥ 0.95
OD11618/2023-2024:Rewinding of A.C. Ceiling Fan all sizes and make including oiling , greasing as required. New Model (Light Weight)
OD11619/2023-2024:Replacement of Fan condensor 2.5 mfd as required.
OD11620/2023-2024:Replacement of Ball Bearing of size 117/120 NBC equivalent SKF make as required.
OD11621/2023-2024:S I T C of metal clad, powder coated, compartmentalized cubical panel board as per CPWD electrical specifications including insulated aluminum bus bars, supports, interconnection, erection of switchgears with depth 30 cm to 60 cm and making provisions for termination of incoming/ outgoing cables/ bus ducting and making foundation etc as required. (Suitable for 400 Amp TP 8 N)
OD11622/2023-2024:Comprehenive AMC(Annual Maintenance Contract) for repair and maintenance of Tube Wells installed at Various Municipal community services buildings for depth of 50 Mtr to 100 Mtr .Cost for one Tube wells with Submersible P/Set etc up to 1/1.5
Iluminators And Circuiteers
Bidder Name
Iluminators And Circuiteers
M/S. A.K. Electricals
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .