Loading…
Loading…
| # | Company | Amount |
|---|---|---|
| 1 | ₹64.7 Cr B 38 SECTOR 32 INSTITUTIONAL AREA NEAR JHARSA GURGAON 122 001 HARYANA | ₹64.7 Cr |
Tender Value
₹64.7 Cr
Closing Date
30 Dec 2021, 11:00 amClosed
Comprehensive ARM and operation of Civil, E and M Services (Internal and External), Housekeeping, Security Services, Control & Command Centre, Horticulture/ Landscaping works, SWM, STP etc. of 4608 dwelling unit of various Type II to Type VII at East Kidwai Nagar, New Delhi.
NBCC/CPG/ARM/EKN/New-Delhi/2021/309
NBCC/CPG/ARM/EKN/New-Delhi/2021/309
Open Tender-Domestic
Civil Works General
New Delhi, Delhi
₹1.2 L
Exempted
16 Nov 2021
16 Nov 2021
30 Dec 2021
30 Dec 2021
24 Jan 2022
ABSTRACT OF COST
S. No. Description DSR Amount (In Non Schedule
Rs.) Amount (In Rs.)
Maintenance (After Defect Liability Period of
executing agency)
1.0 ARM of Internal Civil Works including Housekeeping - 17,00,00,943.50
2.0 ARM of Electrical Installations - 3,61,04,020.67
ARM of Wet riser & Sprinkler system, drinking water & sump - 1,42,90,961.77
3.0 pump system, Fire Alarm, Detection System
4.0 Operation of Lifts - 16,74,58,420.97
5.0 Cleaning of Water tank at Terrace/ loft tank 1,22,40,000.00 -
6.0 ARM of External Civil Works - Road, Sewer, water - 2,18,17,850.99
supply, boundary wall etc.
7.0 ARM of Electrical Installations - 3,32,74,718.88
8.0 Cleaning of Sewer line & UG tank 9,52,047.00 -
9.0 Safety of equipments & fixtures - 9,76,64,340.28
10.0 Disposal of building rubbish/ malba/ waste material 30,02,490.00 -
11.0 Horticulture 3,30,92,571.99
S. No. Description DSR Amount (In Non Schedule
Rs.) Amount (In Rs.)
12.0 Internal & External Finishing 2,99,06,533.77 -
13.0 Special Repair Works Civil works 40,70,772.70 27,63,400.99
14.0 Special Repair Works Electrical works 22,62,951.35 47,62,899.63
TOTAL AMOUNT 64,72,57,235.39
TOTAL AMOUNT 64,72,57,235.39
GAURAV Digitally signed by GAURAV
RAVINDRA GAIKWAD
RAVINDRA Date: 2021.11.16 14:39:49
BILL OF QUANTITIES
DSR CIVIL- Description of item of work RATE IN RS. AMOUNT IN RS
2021 DSR derived
S.No. DSR ELECT.- Unit QTY from DSR-
DSR NS DSR NS
2018 2018 (factor
Maintenance of Residential Building
1.00 SH - I: CIVIL WORKS i/c SANITARY , WATER SUPPLY & SEWERAGE SYSTEM
Maintenance and upkeep of all internal civil assets i/c safety, security of all
services at GPRA campus,complete with all materials labour, T&P , machines ,
trucks etc. as required on all days including Sunday and holidays comprising
following operation as per the details of quarters, Buildings, as per direction of
the engineer in charge and as per enclosed GCC, Special & other conditions,
specifications etc.
Cleaning & repairing of lift lobby, staircases, etc, daily sweeping by machine and
/ or manually and picking up of papers, dry leaves & garbage etc. wet mopping of
1.2 floors and mechanised wet mopping periodically , Lift lobby, stairscase at least
every week with phenyl and terrace cleaning once in a month complete to the
entire satisfaction and as per directions of Engineer- in - charge.
1.3 Antitermite treatment, rodant, cockroach & insect treatments etc. complete.
Maintenance ,repairing and cleaning of chajjas, roofs, expansion joints etc, and
removing of cobwebs, beehives, vegetation including disposal of slit, vegetation,
malba, waste garbage etc. to the authorized dumping ground outside the campus
at the location approved by MCD/NDMC complete to
the entire satisfaction and as per the direction of Engineer - in -
Maintenance, repairing and fixing of damaged doors, windows, ventilators of steel,
aluminium, wood , PVC including replacement of glass panes etc. at all floors &
1.5 heights and replacement of necessary fittings & fixtures of approved make and
quality, wherever required to keep them in proper functional conditions to the
entire satisfaction and as per direction of Engineer - in - charge .
Maintenance and repair of plumbing system for the entire campus including
stopping leakages or over flow of water from PVC/RCC over head tanks
1.6 ,cisterns and replacement of damaged fittings i/c CP Brass fitting, ball cocks and
G.I. fittings etc to keep the entire water supply system efficient and functional to
the entire satisfaction and as per direction of Engineer - in - charge .
Maintenance and repair of internal & external plaster, flooring
,masonry & RCC works, pointing on roof tiles , patch plaster on area upto 2.5
sqm ,CC gola i/c fixing of W.C. seat, gully
1.7 trap, W.C trap, floor traps and sealing of leakages from gully trap, W.C trap, floor
trap, drainage and vertical stacks etc. and restoration of existing finishing in the
affected areas to the entire satisfaction and as per direction of Engineer -in -
Welding by electric plant including transportation of electric welding plant at site to
weld broken grills, hinges, doors, windows, gates, railing and any other steel
work of dwelling units, offices, parks, boundary walls etc.complete as per direction
of Engineer -in - charge .
GAURAV Digitally signed by GAURAV
RAVINDRA GAIKWAD
RAVINDRA Date: 2021.11.16 14:40:28
Investigating causes of seepage / dampness/ leakage from roof, wall, floors,
pipes of all kinds etc. Dismantling existing affected portion, arranging required
materials, labours, T&P including taking all necessary measures, rectification
complete in all respect in time bound manner as per satisfaction of Engineer -
in - charge i/c making arrangement of lift/ ladder or jhulla as per required
Replacement of broken, damaged, edge depressed & reverse flow floor tiles
1.10 including base mortar/ adhesive to match with surrounding colour tiles & colours
shades as per specification & complete satisfaction to the Engineer - In- Charge.
Fabrication works in Main Gates, Stair cases, i.e realignments, additional tower
bolts, sliding bolt including making holes & welding wherever required.
Cutting RCC & providing hooks for additional ceiling fans including making repairs
to original condition.
Closing holes in walls, ceilings, floors etc including repairing with cement mortar
or some other suitabe materials to prevent entry of Rats & others animals.
Any other miscellaneous works connection with above as per direction of Engineer
Assigning all the complaints received from any source to the worker of respective
1.15 trade and get back confirmation from the allotee w.r.t. disposal of complaint on
All civil works, housekeeping etc as mentioned above or elsewhere in tender are to
be carried out in all towers and basements
Cleaning & repairing of basement parking spaces, etc, daily sweeping by
machine and / or manually and picking up of papers, dry leaves, grass, earth,
brick bats, stone pieces, etc. disposing of resulting rubbish/ garbage etc,
including removing of garbage from garbage bins to the soild waste management
in the campus complete to keep the entire basement neat and clean including
wet mopping of floors and mechanised wet mopping periodically cleaning once in
a day complete to the entire satisfaction and as per directions of Engineer- in -
Running and Maintenance of NBCC service centre (Main control command center) at
Type IV basement East Kidwai Nagar Complex by providing & operating 24x7
intigrated facility management centre(help desk) with all necessary
manpowers,hardware and software for lodging day to day complaints and duly
intigrated with NBCC Sewa wherever required wherein broadly the following
jobs are required to be performed (Campus and peripherial including operating
staff necessary consumables, computer,software, internet/broadband connection
shall be arranged by the contractor at his cost.)
a. Downloading the complaints received on IVRS/ Emails on daily basis.
Recording the complaints in register received at service centres in person or
through telephone and issuing acknowledgement with complaint no. i/c assigning
the complaint to the workers
of respective trade.
Uploading all the complaints received at the service centre in the IVRS/Emails/E-
sewa system on daily basis.
Uploading the status of attending of the complaints on daily basis on
IVRS/Email/E-sewa system so that the backlog is not more then one day.
Provide automated status/completion of complaints to allottes, Provide system to
e. allow feedback by allottes regarding complaints Generate online reports for
monitoring by Engineer-in-Charge
Preparing the abstract of attended / unattended complaints on daily, weekly and
monthly basis and submitting the same with reasons of unattended complaints,
action plan of completion to the Engineer - in - charge of the service centre or his
authorized representative.
g Generation of vacation/ occupation/inventory reports from IVRS/ Emails/E-sewa.
Any other miscellaneous works connection with above as per direction of Engineer
A. Super Structure - Towers
Type II (60 flats in each tower, Total 7 towers) Per Month Per
Type II (90 flats in each tower, Total 4 towers) Per Month Per
Type III (G+14, Total 12 towers) Per Month Per
Type IV G+14, Total 17 towers) Per Month Per
Type V (G+6 towers, Total 13 towers) Per Month Per
Type V (G+14 towers, Total 6 towers) Per Month Per
Type VI (G+6, Total 10 towers) Per Month Per
Type VII (G+6, Total 9 towers) Per Month Per
Type II & III Per Month Per
TypeIV Per Month Per
Type V Per Month Per
Type VI & VII Per Month Per
SUB TOTAL OF INTERNAL CIVIL WORK INCLUDING HOUSEKEEPING
2 SH-II :: INTERNAL ELECTRICAL INSTALLATIONS
All inclusive AR & maintenance, upkeep of all electrical internal installations, Lights,
Fans, Geysers etc. as per details below at residential units east kidwai nagar, New
2.1 NS Delhi in 24x7 for all days in a month i/c sundays and holidays complete with
materials, and as per direction of Engineer -in-Charge.
• Light points/Fan pts/ Ex-fan pts/ Call bell pts.
• 5 amp plug points
• 15 amp power plug points
• 25/32 amp AC plug points
• Telephone outlet, TV Outlet
• Telephone wire, TV Wire
• control/communication cables/wires, connectors
• OFC, ONT (Optical Network Terminal) device & Box, jack panel
• Splitter boxes, Switches, racks
• LED light fittings
• All type of light fittings
• Ceiling fans 1200 mm/900mm
• Ex-fans 250/300/450mm
• Water Heater Geyser 25 ltrs. and 3 Ltrs (Instant)
• SPN & TPN MCB DB’s with MCB’s, DP, TPN, RCCB
• Rising mains, Bus Bars, Bus duct and Tap off box of different ratings
• LT,HT Cables & Cables trays of different size
• Solar Street Lights, compound lights with LED, all decorative light fittings, control
2.2 gears, Solar panels, Batteries etc.
• All type of feeder pillars with switch gears etc.
• All HT, LT, UG & OFC cables.
• All LT/HT panels i/c RMU ,UPS Panels, Main LT panels , lighting panel, Lift panels,
Blocks panels, Common service panel etc.
• Domestic and fire pump houses.
• DG set with cooling towers and electric sub-stations.
• Lightning Arrestor System
• Earthing system
• Telephone exchange, Intercom, Public address system, Fire alarm system, CC TV
Surveillances system, Water Control & monitoring system.
• Boom barriers & all Security posts with security equipment’s.
• Control rooms having control of CCTV, Telephone, and water monitoring system,
boom barriers, security system.
• Automation of DG sets electric supply, Ventilation system, domestic water, all
water/ drainage/ flushing/ sewage/ sump pump etc.
• OFC network with its associated equipment’s for wifi, telephone, data, TV etc.
• And others services as required to keep the entire system good & operational &
directed by Engineer-in-charge.
• Solar Street Lights, compound lights with LED, all decorative light fittings, control
2.2 gears, Solar panels, Batteries etc.
• All type of feeder pillars with switch gears etc.
• All HT, LT, UG & OFC cables.
• All LT/HT panels i/c RMU ,UPS Panels, Main LT panels , lighting panel, Lift panels,
Blocks panels, Common service panel etc.
• Domestic and fire pump houses.
• DG set with cooling towers and electric sub-stations.
• Lightning Arrestor System
• Earthing system
• Telephone exchange, Intercom, Public address system, Fire alarm system, CC TV
Surveillances system, Water Control & monitoring system.
• Boom barriers & all Security posts with security equipment’s.
• Control rooms having control of CCTV, Telephone, and water monitoring system,
boom barriers, security system.
• Automation of DG sets electric supply, Ventilation system, domestic water, all
water/ drainage/ flushing/ sewage/ sump pump etc.
• OFC network with its associated equipment’s for wifi, telephone, data, TV etc.
• And others services as required to keep the entire system good & operational &
directed by Engineer-in-charge.
Any other works in connection with the smooth operation & maintenance work not
mentioned above, but required to be carried out with in the cost and/ or also as
per direction of the Engineer -in - charge .
2.4 pump house, UG Tank
2.5 Any other pumpset/ other installation
any other work in connection with the smooth operation & maintenance work not
mentioned above ,but required to be carried out within the cost and/ or also as per
direction of engineer-in charge.
Type II (60 flats in each tower, Total 7 towers) Per Month Per
Type II (90 flats in each tower, Total 4 towers) Per Month Per
Type III (G+14, Total 12 towers) Per Month Per
Type IV G+14, Total 17 towers) Per Month Per
Type V (G+6 towers, Total 13 towers) Per Month Per
Type V (G+14 towers, Total 6 towers) Per Month Per
Type VI (G+6, Total 10 towers) Per Month Per
Type VII (G+6, Total 9 towers) Per Month Per
SUB TOTAL OF INTERNAL ELECTRICAL WORK - 3,61,04,020.67
14 SH III:- ARM OF WET RISER & SPRINKLER SYSTEM, DRINKING WATER & SUMP PUMP SYSTEM, FIRE ALARM, DETECTION SYSTEM, Intercom ETC.
All inclusive AR & maintenance of fire-fighting system i.e. including providing
services for operation of manual fire alarm ,detection system, down comer system,
3.1 Pumps intercom & Lift intercom, 24x7 on all days of the year including Holidays as
per terms and conditions attached i/c periodical fire testing, mock drill & obtaining
fire clearance certificate as & when becomes due.
All water lines, motor, pumps, electrical wiring, intake, any other Pump/machinery
Any other works in connection with the smooth operation & maintenance work not
mentioned above, but required to be carried out with in the cost and/ or also as
per direction of the Engineer -in - charge .
Type II & III Per Month Per
TypeIV Per Month Per
Type V Per Month Per
Type VI & VII Per Month Per
SUB TOTAL OF ARM OF WET RISER & SPRINKLER SYSTEM, DRINKING
WATER & SUMP PUMP SYSTEM, FIRE ALARM, DETECTION SYSTEM, ETC. Total - 1,42,90,961.77
SUB HEAD-IV : LIFTS OPERATION
Providing services for running operations i/c cleaning and safety, security, watch&
ward of following lifts on all days of the year including Sunday & Holidays as per
terms and conditions.
Lift of M/s. Schindler Elevators (8 Passenger (544kg ) with Gearless MRL Elevator
System (2 nos in each tower)
Lift of M/s. Schindler Elevators (1088kgs Service Lift with Gearless MRL Elevator
System (1No for each tower)
4.2 24x7 shall be deployed.
Type II (11 towers) Per Month Per
Type III (12 towers) Per Month Per
TypeIV (17 towers) Per Month Per
Type V (19 towers) Per Month Per
Type VI (10 towers) Per Month Per
Type VII(9 towers) Per Month Per
SUB TOTAL OF LIFTS OPERATION TOTAL - 16,74,58,420.97
Sub Head V:-Cleaning of Water tank at Terrace/ loft tank,UG Tanks
Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre
capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish
from the tank and cleaning the tank with fresh water disinfecting with bleaching
powder @ 0.5gm per litre capacity of tank, including marking the date of cleaning
on the side of tank body with the help of stencil and paint and disposing of malba,
all complete as per direction of Engineer-in-Charge. (The old date already written
on tank should be removed with paint remover or black paint and if date is not
written with the stencil or old date is not removed deduction will be made @ Rs.
5 14.75A 0.10 per litre if during cleaning any GI fittings or ball cock is damaged that is to be litre 30600000.00 0.40 1,22,40,000.00
repaired by contractor at his own cost and nothing extra will be paid on this
a) Domestic tank in towers
b) Flush Tank in towers
c) Fire tank in towers
(Twice in a year)
SUB TOTAL OF CLEANING OF WATER TANK 1,22,40,000.00 -
SH-VI ::EXTERNAL CIVIL WORK
Maintenance and upkeep of all external assets and services i/c safety of all
services in common areas, service centre, under ground & over head tanks at
GPRA campus,complete with all materials labour, T&P , machines , trucks etc. as
required on all days including Sunday and holidays comprising following operation
6.1 as per the details of quarters, Buildings,external services, as per direction of the
engineer in charge and as per enclosed GCC, Special & other conditions,
specifications etc.
Cleaning & Maintenance of garbage bins i/c cleaning garbage chamber twice/thrice
in a day or as required by removing collected garbage from garbage bins,
6.2 disposing the garbage at soild waste management garbage yard by using the
NS covered mechanical vehicle, complete to the entire satisfaction of Engineer - in -
Maintenance and operation of water supply grid and valves including unfiltered
water supply line in the entire campus to keep the water supply system efficient
and operational at all times complete to the entire satisfaction and as per direction
of the Engineer - in - Charge.
Sweeping and wet mopping of Electrical Sub-Stations, pump house, sewege
treatment plant, adjoining open area, public toilet, pavements, basement parking
6.4 etc. daily including washing basment parking once in a week complete to the entire
satisfaction and as per direction of Engineer -in - charge .
Maintenance, repair of boundary wall i/c M.S grill, all items installed in Central
6.5 park like sitting benchs, children play equipments etc. & fogging of whole
complus periodically as an when required.
Cleaning & repairing of Central Road/Roads/Gurudwara Road, cycle track,
pavements, footpaths, walking tracks in lawns/park , open areas, storm water
drains, floors of common areas , spaces, etc,of full campus daily sweeping by
machine and / or manually and picking up of papers, dry leaves, grass, earth,
brick bats, stone pieces, etc. and cutting grass from the edges of Footpaths,
surrounding of building, open areas, etc, inside the campus and disposing of
resulting rubbish/ garbage etc, including removing of garbage from garbage bins
to the solid waste management in campus complete to keep the entire campus
neat and clean including wet mopping of floors and mechanised wet mopping
periodically cleaning once in a month complete to the entire satisfaction and as
per directions of Engineer- in - charge.
Periodical cleaning & Maintenance of sewerage & drainage network by using
Pressure jetting machines twice in a year or more, if required i/c desiliting of
gully traps, manholes, gratings, chocked sewer line,rain water harvesting pits of
6.7 whole campus, including all the sewer pipes lines,SW piped/coverd drains and
rain water pipe of all size twice in a year to the entire satisfaction of Engineer -
Running and Maintenance of NBCC service centre (Main control command center) at
Type IV basement East Kidwai Nagar Complex by providing & operating 24x7
intigrated facility management centre(help desk) with all necessary
manpowers,hardware and software for lodging day to day complaints and duly
6.8 intigrated with NBCC Sewa wherever required wherein broadly the following
jobs are required to be performed (Campus and peripherial including operating
staff necessary consumables, computer,software, internet/broadband connection
shall be arranged by the contractor at his cost.)
Recording the complaints in register received at service centres in person or
through telephone and issuing acknowledgement with complaint no. i/c assigning
the complaint to the workers of respective trade.
Any other miscellaneous works connection with above as per direction of Engineer
b. -in - charge .
Cleaning rubbing scrubbing with the help of scrubbing machine having nylon
brushes with the help of detergent to remove the stains of dust, furniture
mopping etc. on mosaic, tile, cement concrete flooring all complete as per direction
of Engineer-in-charge.
Investigating causes of seepage / dampness/ leakage from , valve, pipes of all
kinds etc. Dismantling existing affected portion, arranging required materials,
6.10 labours, T&P including taking all necessary measures, rectification complete in all
respect in time bound manner as per satisfaction of Engineer - in - charge i/c
making of all arrangement of T & P required all complete.
Replacement of broken, damaged, edge depressed & reverse flow floor tiles
including base mortar/ adhesive to match with surrounding colour tiles & colours
6.11 shades as per specification & complete satisfaction to the Engineer - In- Charge.
Fabrication works in Main Gates, i.e realignments, additional tower bolts, sliding
6.12 bolt including making holes & welding wherever required.
Closing holes in walls, ceilings, floors etc including repairing with cement mortar
6.13 or some other suitabe materials to prevent entry of Rats & others animals.
Any other miscellaneous works connection with above as per direction of Engineer
6.14 -in - charge .
All internal roads, Sewerline, water supply line, boundary wall, RWH system etc. Per Sqm per
(Total area is taken as 47300 sqm (Max.) Month
SH-VII :: ANNUAL RUNNING & OPERATION OF EXTERNAL ELECTRIFICATION, ELECTRIC SUB-STATION
EQUIPMENTS,DG SET ON GRID SYSTEM ETC.
All inclusive AR & maintenance, upkeep of all electrical external installations,Solar
light,street light & other fancy (Decorative) external light etc. in the residential
campus east kidwai nagar, New Delhi in 24x7 for all days in a month i/c sundays
7.1 and holidays complete with materials (excluding replacement of damaged battery),
and as per direction of Engineer -in-Charge.
Any other works in connection with the smooth operation & maintenance work not
mentioned above, but required to be carried out with in the cost and/ or also as
7.2 per direction of the Engineer -in - charge .
All inclusive AR & maintenance i/c providing services for operation of electric sub-
station equipments and DGset,including cooling towers on all days of the year
7.3 including Sunday & Holidays as per terms and conditions
Running, Operation & AR & maintenance of - 1500 KVA DG sets, stand by DG
sets on all the days including Sundays & Holidays complete with all materials i/c
7.4 Diesel oil etc as per terms and conditions attached.
7.5 1500 KVA DG set,1010 KVA DG Sets, 750 KVA DG Sets
HT Panel Dry Type Transformer (2000KVA/1600KVA)
LT Main Panel LT main common service panel with PLC control and DG automation
LT block panels
LT common service panels LT lighting panel
LT meter panels
7.6 LT rising mains with main adaptor switch
LT lifts panels at top roof Ventilation panel & starters
Ventilation fan (for basement fresh air & exhaust, lift well & stair case
pressurization)
UPS lighting panels Domestic water panels Sum-Pump Panel sewerage panel 10
KVA three phase UPS Submersible pump for sump HVAC SYSTEM BOOM
Weekly/periodically preventive maintenance shall be essentially carried out by
7.7 deploying full team on Tuesday to check each & every civil , electrical , pumps
items etc and maintained the record .
Any other item(s)/ work(s) in connection with above shall be carried out as per
direction of the Engineer -in - charge .
Type II & III Per Month Per
TypeIV Per Month Per
Type V Per Month Per
Type VI & VII Per Month Per
Consumtion of fuel (Diesel) in DG sets in case of power cut as per direction of
Engineer In-charge. The agency has to maintain the diesel consumption register
e which shall be countersigned by Engineer In-charge. per litre 50,325.00 88.77 44,67,350.25
SUB TOTAL OF ANNUAL RUNNING & OPERATION OF EXTERNAL
ELECTRIFICATION, ELECTRIC SUB-STATION EQUIPMENTS,DG SET ON GRID TOTAL - 3,32,74,718.88
CLEANING OF SEWER LINE BY JETTING SEWER CLEANING MACHINE
Cleaning of chocked sewer line by diesel running vehicle mounting hydraulic
operated high pressure suction cum jetting sewer cleaning machine fitted with
pump having 4000 litres suction capacity and 6000 litres water jetting tank capacity
8 14.77 including skilled operator, supervising engineer etc. for cleaning and partial metre 3,330.00 285.90 9,52,047.00
desilting of manholes and dechocking of sewer lines. Dechocking and flushing of
sewer line from one manhole to another by high pressure jetting system of 2200
PSI for sewer line from 150mm dia upto 300mm dia for all depth.
CLEANING OF UNDER GROUND TANK
Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre
capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish
from the tank and cleaning the tank with fresh water disinfecting with bleaching
powder @ 0.5gm per litre capacity of tank, including marking the date of cleaning
on the side of tank body with the help of stencil and paint and disposing of malba,
all complete as per direction of Engineer-in-Charge. (The old date already written
9 14.75A on tank should be removed with paint remover or black paint and if date is not litre 0 0.40 0.00
written with the stencil or old date is not removed deduction will be made @ Rs.
0.10 per litre if during cleaning any GI fittings or ball cock is damaged that is to be
repaired by contractor at his own cost and nothing extra will be paid on this
a) Under Ground water tank - Domestic & Fire (Twice in a year)
SUB TOTAL 9,52,047.00 -
SH-IX FOR SAFETY & SECURITY PERSONNEL 24X7
Operation of watch & ward at entry and exit point, basement & other required
10 NS location round the clock with all requisite eccessories etc complete i/c complete Per Month 3240.00 30,143.31 9,76,64,340.28
basement parking arrangement.
SH-XI DISPOSAL OF GARBAGE ETC.
"Disposal of moorum/ building rubbish/ malba/ similar unserviceable, dismantled or
waste material by mechanical transport including loading, transporting, unloading
to approved municipal dumping ground for lead upto 10 km for all lifts, complete as
per directions of Engineer-in-Charge.
11 1.1.18 Note - Item to be applicable in urban areas having directions for restricted hours for cum 7,300.00 411.3 30,02,490.00
movement/plying of load carriying motor vehicle of 3.5 cum or more."
(only waste material which can not be recyled at in house Solid waste treatmnet
plant or in case SWMP is not working)
SUB TOTAL OF DISPOSAL OF GARBAGE ETC. SUB TOTAL 30,02,490.00 -
SH-XII HORTICULTURE WORK
Complete maintenance of the entire garden features of the garden area i/c lawn,
,shrubs, hedge, potted plants, flower beds, creepers etc. and other garden
features including watering, hoeing, making of plants basin, manuring, trimming
and cleaning of hedges/ plants beds, spraying of insecticides, fungicides, weeding,
mowing and top dressing of lawn with good earth and manure and hedge clipping
12 NS and removal of the garden waste as per direction and satisfaction of the officer-in-
charge (including the cost of manure and good earth) to maintain the plants,
hedge and lawns in good and healthy conditions at all the time during the
maintenance period as mentioned in general terms & conditions
Entire residential units of Type II,III,IV,V,VI,VII campus and inside the compound
wall and outer periphery of front side compound wall & at entrance gate etc.(Rate
12.1 are for total Green Area 1,13,600sqm however the payment will be made Per Month 36.00 9,19,238.11 3,30,92,571.99
in ratio of the area in hand for maintenance)
SUB TOTAL OF HORTICULTURE - 3,30,92,571.99
GRAND TOTAL 58,98,98,366.07
GRAND TOTAL 58,98,98,366.07
INTERNAL & EXTERNAL FINISHING
Providing and applying plaster of paris putty of 2 mm thickness over plastered
surface to prepare the surface even and smooth complete.
14 13.37 White washing with lime to give an even shade :
14.1 13.37.1 New work (three or more coats) sqm 13,262.56 32.45 4,30,370.07 -
Distempering with oil bound washable distemper of approved brand
and manufacture to give an even shade :
New work (two or more coats) over and including water
thinnable priming coat with cement primer
15 13.45 Finishing walls with textured exterior paint of required shade :
New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including
priming coat of exterior primer applied @ 2.20kg/10 sqm
Providing and applying white cement based putty of average thickness 1 mm, of
16 13.80 approved brand and manufacturer, over the plastered wall surface to prepare the sqm 2500.00 123.85 3,09,625.00 -
surface even and smooth complete.
Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic
Compound ) content less than 50 grams/ litre, of approved brand and manufacture
Wall painting with premium acrylic emulsion paint of interior grade, having VOC
(Volatile Organic Compound ) content less than 50 grams/ litre. of approved brand
and manufacture,including applying additional coats wherever required to achieve
even shade and colour.
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied
19 13.52 as per manufacturer's specifications including appropriate priming coat,
preparation of surface, etc. complete.
Wall painting with plastic emulsion paint of approved and manufacture to give an
20.1 13.98.1 One or more coats on old work. sqm 55585.00 90.85 50,49,897.25 -
Painting with synthetic enamel paint of approved brand and manufacture of
required colour to give an even shade :
21.1 13.99.1 One or more coats on old work. sqm 37500.00 86.55 32,45,625.00 -
22 13.109 Finishing walls with water proofing cement paint of required shade :
Old work (one or more coats applied @ 2.20 kg/10 sqm) over priming coat of
primer applied @ 0.80 litrs/10 sqm complete including cost of Priming coat.
22.2 13.109.2 Old work (one or more coats @ 2.20 kg/10 sqm) complete. sqm 63.25 0.00 -
22.3 13.110 Finishing walls with textured exterior paint of required shade :
Old work (Two or more coats on existing cement paint
surface applied @ 3.28 ltr/10 sqm.
22.5 13.110.2 Old work (One or more coats) applied @ 1.82 ltr/10 sqm. sqm 118.84 0.00
23 13.114 Melamine polishing on wood work (one or more coat). sqm 431.62 118.35 51,082.23 -
White washing with lime to give an even shade for old work (one or more coats)
TOTAL OF CIVIL WOKS CARRIED OVER TO ABSTRACT OF COST 2,99,06,533.77 0
SPECIAL REPAIR WORKS
Marble work gang saw cut (polished and machine cut) of thickness 18mm for wall
lining (veneer work), backing filled with a grout of average 12 mm thick in cement
mortar 1:3 (1 cement : 3 coarse sand) including pointing with white cement mortar
24 8.1 1:2 (1 white cement : 2 marble dust) with an admixture of pigment to match the
marble shade: (To be secured to the backing by means of cramps, which shall be
paid for separately).
Raj Nagar Plain white marble/ Udaipur green marble/ Zebra black marble.
Providing edge moulding to 18 mm thick marble stone counters, Vanities etc.,
including machine polishing to edge to give high gloss finish etc.complete as per
25 8.3 design approved by Engineer-in-Charge. Marble work
Extra for fixing marble /granite stone, over and above corresponding basic item, in
facia and drops of width upto 150 mm with epoxy resin based adhesive, including
cleaning etc. complete.
Extra for providing opening of required size & shape for wash basin/ kitchen sink in
kitchen platform, vanity counter and similar location in marble/Granite/stone work,
27 8.5 including necessary holes for pillar taps etc. including moulding, rubbing and Each 100.00 808.15 80,815.00
polishing of cut edges etc. complete.
Providing and fixing bright finished brass 100 mm mortice latch and lock with 6
levers and a pair of lever handles with necessary screws etc. complete (best make
of approved quality).
Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic
coating not less than grade AC 10 as per IS : 1868), transparent or dyed to
29 9.96 required colour or shade, with nuts and screws etc. complete :
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating
not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour
or shade, with necessary screws etc. complete
Providing and fixing aluminium handles ISI marked anodised (anodic coating not
less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or
shade with necessary screws etc. complete :
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised
(anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to
required colour and shade, with necessary screws etc. complete.
32.1 9.101.1 Single rubber stopper Each 100.00 35.50 3,550.00
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed
with grey cement slurry mixed with pigment to match the shade of the slab
33 11.26 including rubbing and polishing complete with base of cement mortar 1 : 4 (1
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on
12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed
34 11.27 with grey cement slurry mixed with pigment to match the shade of the slabs, sqm 200.00 2,038.55 4,07,710.00
including rubbing and polishing complete.
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS:15622
(thickness to be specified by the manufacturer), of approved make, in all colours,
shades except burgundy, bottle green, black of any size as approved by Engineer-
in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement
36 8.31 mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ sqm 200.00 1063.45 2,12,690.00
3.3kg per sqm, including pointing in white cement mixed with pigment of matching
Providing and laying vitrified floor tiles in different sizes (thickness to be specified
by the manufacturer) with water absorption less than 0.08%and conforming to IS :
36 15622, of approved make, in all colours and shades, laid on 20mm thick cement
mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white
cement and matching pigments etc., complete.
Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories
for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A,
37 12.42 including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for
thermal expansion.
38.3 12.42.3.2 Single tee with door 110x110x110 mm Each 20.00 205.45 4,109.00
Proving and fixing unplasticised- PVC Pipe clps of approved design to unplasticised-
PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with
39 12.43 M.S. screws of required length including cutting brick work and fixing in cement
mortar 1:4 ( 1 cement : 4 coarse sand) and amking good the wall etc.
Providing and fixing to the inlet motuh of rain water pipe cast iron grating 15 cm
40 12.44 diameter and weighnin not less than 440 grams Each 20.00 47.90 958.00
Providing and fixing false ceiling at all height including providing and fixing of frame
work made of special sections, power pressed from M.S. sheets and galvanized with
zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of
angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm,
at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5
mm dia x 50mm long with 6mm dia bolts other flange of cleat fixed to the angle
hangers of 25x10x0.50 mm of required length with nuts & bolts of required size
and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm
running at the rate of 1200 mm centre to centre to which the ceiling section 0.5
mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips
of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular
to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230
41 12.45 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm
thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of
ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with
25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to
ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x
25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered
and square edges of the board with recommended jointing compound , jointing
tapes , finishing with jointing compound in 3 layers covering upto 150 mm or both
sides of joint and two coats of primer suitable for board, all as per manufacturer’s
12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- Part I
42 13.1 12 mm cement plaster of mix :
15 mm cement plaster on the rough side of single or half brick wall of mix
12mm cement plaster finished with a floating coat of neat cement of mix
45 13.16 6 mm cement plaster of mix :
Providing and fixing trap of self cleansing design with screwed down or hinged
grating with or without vent arm complete, including cost of cutting and making
good the walls and floors :
100 mm inlet and 100 mm outlet
Making chases up to 7.5x7.5 cm in walls including making good and finishing with
47 18.78 matching surface after housing G.I. pipe etc. Mtr 94.00 171.80 16,149.20
Providing and fixing aluminium work for doors, windows, ventilators and partitions
with extruded built up standard tubular sections/ appropriate Z sections and other
sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash
fasteners of required dia and size, including necessary filling up the gaps at
junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene
48 21.1 gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and
jointed mechanically wherever required including cleat angle, Aluminium snap
beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as
per architectural drawings and the directions of Engineer-in-charge. (Glazing,
paneling and dash fasteners to be paid for separately) :
48.1 21.1.1 For fixed portion
Anodised aluminium (anodised transparent or dyed to required shade according to
48.1.1 21.1.1.1 IS:1868, minimum anodic coating of grade AC 15)) Kg 50.00 433.95 21,697.50
For shutters of doors, windows & ventilators including providing and fixing hinges/
pivots and making provision for fixing of fittings wherever required including the
49 21.1.2 cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for
Anodised aluminium (anodised transparent or dyed to required shade according to
49.1 21.1.2.1 IS:1868, minimum anodic coating of grade AC 15)) sqm 50.00 531.80 26,590.00
Providing and fixing glazing in aluminium door, window, ventilator shutters and
partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the
50 21.3 architectural drawings and the directions of engineer-in-charge .
(Cost of aluminium snap beading shall be paid in basic item): With float glass
Providing and fixing stainless steel SS 304 grade adjusatble friction window stays of
approved quality with necessary stanlss steel screws etc. to side hung windows,
to the directions of Engineer -in- charge
Providing and fixing glazing in aluminium door, window, ventilator shutters and
partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the
architectural drawings and the directions of engineer-in-charge.
52.1 21.3.1 With float glass panes of 4.0 mm thickness sqm 50.00 1019.80 50,990.00
21.15 Providing and fixing aluminium casement window fasteners of required length
21.15.1 Anodized (AC 15) aluminium
Providing and laying water proofing treatment in sunken portion of WCs ,bathroom
etc.by applying cement slurry mixed with water proofing cement compound
consisting of applying ; a) first layer of slurry of cement @ 0.488 kg/sqm mixed
with water proofing cement compound @ 0.253 kg/sqm . this layer will allowed to
air cure for 4 hours b)Second layer of slurry of cement @ 0.242 kg/sqm mixed with
54 22.5 water proofing cement compond @ 0126kg/sqm. this layer will be allowed to air sqm 50.00 516.60 25,830.00
cure for 4 hours followed with water curing for 48 hours. the rate includes
preparation of surface, treatment and seiling of all joints,corners, junctions of pipes
and masonry with polymer mixed slurry.
Providing and fixing mirror of superior glass (of approved quality) and of required
shape and size with plastic moulded frame of approved make and shade with 6
mm thick hard board backing :
55.1 17.32.2 Rectangular shape 453x357mm Each 50.00 1158.95 57,947.50
Providing and Laying 18mm thick Granite stone flooring in all shapes and at all
heights in steps, risers, laid on 20mm avg thick cement plaster 1:3 ( 1 cement:3
56 NS coarse sand) and jointed with mathcing color pigment mixed in white cement to sqm 50.00 2,668.96 - 1,33,448.23
match the shade of slab, including rubbing, polishing complete.
18mm thick granite stone work for wall linning over 20mm thick bed of cement
motor 1:3 1cement :3 coarse sand and cement slurry @3.3kg 12mm thick including
pointing with white cement.(Basic rate of granite stone=1500 per sqm.)
Providing and fixing white vitreous china Parryware floor mounted Bristol ( CODE
C8492) OR EQUIVALENT water closet of approved shape including providing & fixing
58 NS white vitreous china cistern with dual flush including seat cover, and cistern fittings,
nuts, bolts and gasket etc complete.
fitting, of flushing capacity 3 litre/6 litre (adjustable to 4 litre/8 litres),
Providing and fixing of Health Faucet with metal hose and holder in Polished
Chrome, (Parryware - T9940A1 / Cera - CG 105/ Hindware -making good the walls,
floors, slab wherever required as per direction of Engineer-Incharge.
F160059) alongwith all necessary accessories complete including cutting,
Providing and fixing of C.P Toilet Paper holder with wall flange, (Parryware -
T6005A1 / Cera - CA 106/ Hindware - F840008 / or cutting, making good the walls,
60 NS floors, slab wherever required as per direction of Engineer-Incharge.
60.1 NS equivalent) alongwith all necessary accessories complete including Each 20.00 597.19 11,943.70
Providing and fixing of C.P. 2 Way bib cock (Parryware - G3034A1 / Cera - CQ 605
/ Hindware - F100004 / or equivalent) with wall flangealongwith all necessary
61 accessories complete including cutting, making good the walls, floors, slab 10.00 905.77 9,057.67
wherever required as per direction of Engineer-Incharge.
Providing and fixing white vitreous china flat back half stall urinal (Parryware -
C0575/ Cera - 5013 / Hindware - 96005) with fittings, standard size C.P. brass
flush pipe, waste fittings bottle trap, (Parryware -T3202A1 / Cera - CM104B /
Hindware -F850003) spreaders (ParrywareC8095 / Cera - CG501 / Benelava-
62 NS BLACP70602 ) with unions and clamps (all in C.P. brass) other couplings in C.P. Each 10.00 4,699.87 46,998.73
brass, alongwith all necessary accessories complete including cutting, making good
the walls, floors, slab wherever required as per direction of Engineer-
Providing and fixing white vitreous china Urinals Partitions alongwith all necessary
accessories complete including cutting, making good the walls, floors, slab
63 NS wherever required as per direction of Engineer-Incharge.(Parryware C0571 / Cera - Each 2.00 1,224.39 2,448.78
5011 / Hindware 61001 or equivalent)
Providing and fixing of Stainless Steel Kitchen Sink without veg Bowls and drain
board (Parryware- C 8538 / Jayna- Galaxy SBFB 04 ) alongwith all necessary
64 NS accessories complete including cutting, making good the walls, floors, slab
wherever required as per direction of Engineer-Incharge.
Single bowl without veg bowl & drain bowl board. Overall size bowl size 17 x 17
Providing and fixing of Single Lever C.P. Sink Mixer with shower pollout with 1.5
mtr double lock flexible hose, table mounted (Parryware -T0835A1 / Cera - CS231A
66 / Hindware - F130013) alongwith all necessary accessories complete including 10.00 4,343.74 43,437.44
cutting, making good the walls, floors, slab wherever required as per
direction of Engineer-Incharge.
Providing and fixing C.P. liquid Soap Dispenser With Glass Bottle / Stainless steel (
Chilly - LSD01 / Euronices - ES 14H / Jaquar - AKB-35735) alongwith all necessary
67 NS accessories complete including cutting,making good the walls, floors, Each 10.00 1,361.17 13,611.74
slab wherever required as per direction of Engineer-Incharge.
Providing and fixing of Stainless Steel Soap Dish (Parryware - T6302A1 / Cera -
CA103 / Hindware - F870004) alongwith all necessary accessoriescomplete
68 NS including cutting, making good the walls, floors, slab wherever required as per Each 5.00 1,244.40 6,221.99
direction of Engineer-Incharge.
Providing and fixing of Towel Rail (Parryware - T6001A1 / Cera - CA101/ Hindware-
F890011) alongwith all necessary accessories complete including cutting, making
69 NS good the walls, floors, slab wherever required as per direction of Engineer- Each 5.00 1051.73 5,258.64
Providing and fixing of Robe Hook, (Parryware - T6006A1 / Cera -CA105 / Hindware-
F880004) alongwith all necessary accessories complete including cutting, making
70 NS good the walls, floors, slab wherever required as per direction of Each 10.00 1051.73 10,517.29
Engineer-Incharge.
Providing, Fixing, Testing and Commissioning of C.P. bath and shower fittings
comprising of :(Parryware - G1841A1 OR EQUIVALENT)1 No. CP Wall mixer with
71 spout and overhead shower arrangement.1 No. Spout with CP Cover1 No. Over 100.00 3,027.60 3,02,759.91
Head Shower ( T9901A1) consisting of arm with wall flange complete in all respect
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of
approved quality conforming to IS:8931 a) 15 mm nominal bore (Parryware -
G1807A1 / Cera - CS 108A / Hindware F230004)
72.1 NS 15mm nominal bore Each 100.00 567.15 56,714.89
Providing and fixing Floor Drain / Nahani Trap including all fitting and accessories
fixed in cement mortar complete in all respect. This includes the cost of cutting
73 NS chases and making good the same including testing of joints complete as per
direction of Engineer in Charge.
Providing and fixing 100% stainless steel "cockroach" trap of approved make and
quality on top of floor trap / Nahani Trap. The rate includes the cost of all ancillary
74 works as required to complete the work.This includes the cost of cutting chases and 250.00 786.51 1,96,627.59
making good the same including testing of joints complete as per direction of
Engineer in Charge.
Providing and fixing Rectangular HDPE Water Tank of 100 Ltrs. Capacity and
75 complete with cover, nut bolts etc. of approved makes. Each 5.00 625.54 3,127.72
Providing and fixing solid plastic seat with lid for pedestal type W.C. pan complete :
76.1 17.20.1 White solid plastic seat with lid each 50.00 586.55 29,327.50
Providing and fixing of C.P.brass angle valve for basin mixer and geyser points of
77 18.53 approved quality conforming to IS:8931 a) 15 mm nominal bore
COLD/HOT WATER SUPPLY SYSTEM
Providing and fixing G.I. pipes complete with G.I. fittings and clamps including
cutting and making good the wall etc.
Internal work _ Exposed on wall (Shaft, Terrace)
Painting G.I. Pipes and fittings with two coats of anti-corrosive bitumastic paints of
79 18.4 approved quality.
79.9 NS 100 mm diameter pipe Mtr 20.00 57.79 - 1155.74
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal
stability for hot & cold water supply, including all CPVC plain & brass threaded
fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of
80 18.8 pipes & fittings with one step CPVC solvent cement and the cost of cutting chases
good the same including testing of joints complete as per direction of Engineer in
Concealed work, including cutting chases and making good the walls etc.
Providing and fixing ball valve (brass) of approved quality, High or low pressure,
with plastic flots complete:
81.4 NS 32 mm dia nominal bore each 10.00 1387.676795 13,876.77
81.5 NS 40 mm dia nominal bore each 10.00 2128.45 21,284.48
81.6 NS 50 mm dia nominal bore each 10.00 3,006.54 30,065.42
Providing and fixing gun metal gate valve with C.I. wheel of approved quality
Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated
five layer, 3 mm thick water proofing membrane, black finished reinforced with
glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @
0.40 litre/sqm by the same membrane manufactured of density at 25°C, 0.87 -
0.89 kg/litre and viscocity 70 - 160 cps. Over the primer coat the layer of
membrane shall be laid using butane torch and sealing all joints etc., and preparing
the surface complete. The vital physical and chemical parameters of the membrane
83-a 14.90.1 shall be as under : Joint strength in longitudinal and transverse direction at 23°C as sqm 1500.00 534.10 8,01,150.00
350/300 N/5 cm. Tear strength in longitudinal and transverse direction as 60/80N.
Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C
when tested in accordance with ASTM, D - 5147. The laying of membrane shall be
got done through the authorised applicator of the manufacturer of membrane :
Providing & Exicuting injection grouting for water proofing of raft,walls, slabs etc by
grouting 15 mm dia 6 inch long GI nipple and injecting cement slurry mixed with
83-b NS water proffing compound @1 kg/50kg of Cement by suitable pressure pump sqm 3500.00 300.00 1049989.738
complete as per direction of EIC
SUB TOTAL OF SPECIAL REPAIRS CIVIL WORKS 40,70,772.70 27,63,400.99
SPECIAL REPAIRS - Electrical Works
Point wiring in MS conduit, with modular type switch Wiring for light point/ fan
point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper
84 1.3 conductor single core cable in surface / recessed steel conduit, with modular switch,
modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC
insulated copper conductor single core cable etc. as required.
Installation of exhaust fan in the existing opening, including making good the
85 1.5 damage, connection, testing, commissioning etc. as required. 0
Supplying and fixing two module stepped type electronic fan regulator on the
existing modular plate switch box including connections but excluding modular plate
etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on
surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket
87 1.31 outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to each 50 416.77 20,838.41 0
be used in non residential buildings).
Supplying and fixing suitable size GI box with modular plate and cover in front on
surface or in recess, including providing and fixing 6 pin 15/16 amps modular
socket outlet and 15/16 amps modular switch, connection etc. as required.
Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all
Supplying and fixing following way prewired vertical type TP&N MCB distribution
board of steel sheet for 415 volts on surface/ recess complete with loose wire box
of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned
90 2.3 copper bus bar, common neutral link, earth bar, din bar for mounting MCB's, 0
terminal connectors for all incoming and outgoing circuits, duly prewired with
Supplying and fixing following way, horizontal type three pole and neutral, sheet
steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned
91 2.4 copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder 0
painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power
cable of 1.1 KV grade of following size direct in ground including excavation, sand
cushioning, protective covering and refilling the trench etc as required.
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell
point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper
94 conductor single core cable in surface/ recessed steel conduit, and earthing the
point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc.
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell
point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper
DSR-2018, conductor single core cable in existing surface/ recessed steel/PVC conduit, and
ITEM NO. 1.54 earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single
core cable etc. as required.
95 NS STELLER BRITE LED GLASS TUBE-20W LED-2100 LUMENS (philips) or equivalent. each 200 541.32 1,08,264.00
96 NS BN208C LED40/DL L 1200 FR-40W LED-4000 LUMENS (Philips) or equivalent. each 200 1177.38 2,35,475.15
WT202W P LED 6S CW PSU S1 PC P3495-10W LED 600 LUMENS (PHILIPS)
RECESSED DN 391B LED6S-6500 PSU-7.5W LED-600 LUMENS (PHILIPS) OR
31083 SHELLINE WALL LAMP LED-9W LED-800 LUMENS (PHILIPS) OR
7W LED WALL LIGHT -LED DECON 05AAM WITH CYLINDRICAL GLASS OR
518C LED9S 6500 PSUOD WH 15W LED-900 LUMENS (PHILIPS) OR
RECESSED DN 392B LED 10S-6500 PS-11.5W LED-1000 LUMENS (PHILIPS)
DN 391B LED6S-6500 PSU WH 7.5W LED-600 LUMENS (PHILIPS) OR
RC 380 B LED 30S-6500 PSD OD WH-40W LED 3000 (PHILIPS) OR
518C LED9S 6500 PSUOD WH 15W LED-900 (INTEGRA SURFACE 10W)
LUMENS (PHILIPS) OR EQUIVALENTS
RECESSED DN 392B LED 10S-6500 PS-11.5W LED-1000 (EDGEPRO ROUND 15W)
LUMENS (PHILIPS) OR EQUIVALENTS
Wiring for circuit/ submain wiring along with earth wire with the following sizes of
107 1.14 FR PVC insulated copper conductor, single core cable in surface/ recessed medium
class PVC conduit as required
Supplying and fixing following modular switch/ socket on the existing modular plate
108 1.24 & switch box including connections but excluding modular plate etc. as required. 0.00
108.3 1.24.4 3 pin 5/6 amp A socket outlet each 25.00 115.36 2,884.12
Supplying and fixing following size/ modules, GI box along with modular base &
109 1.27 cover plate for modular switches in recess etc as required.
Supplying and fixing following Modular base & cover plate on existing modular
110 1.28 metal boxes etc. as required.
Supplying and fixing of following sizes of heavy guage PVC conduit along with
accessories in surface/recess including cutting the wall and making good the same
in case of recessed conduit as required.
Re-filling of all types of fire extinguishers ( e.g. 4.5kg /9 kg CO2 Type ,6kg /9 kg
118 NS ABC type, 9kg water co2 type etc) including transporation to & fro get to be done Nos. 2290.00 450.00 1030500
as per DFS/ manufacturers recommondations .
Telephone wiring in Existing Conduits: Supplying and drawing following pair 0.61 sq
DSR-2018, item mm FR PVC insulated annealed copper conductor, unarmored telephone cable in
no. 1.18 the existing surface/ recessed steel/ PVC conduit as required.
Supplying and fixing following modular switch/ socket on the
existing modular plate & switch box including connections but
120 excluding modular plate etc. as required. Nos. 100.00 123.68 12,367.93
Telephone socket outlet
Supplying and fixing following modular switch/ socket on the
existing modular plate & switch box including connections but
121 excluding modular plate etc. as required. Nos. 50.00 123.68 6,183.97
TV antenna socket outlet
Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar bent to
Civil DSR-2021, shape with hooked ends in R.C.C. slabs, beams during laying including painting the
item no.-10.17 exposed portion of loop, all as per standard design complete.
Supply & Installation of high discharge sealed maintenance free battery of12V 12AH
122 NS for Lifts/UPS inculding deduction for unserviceable batterys (Rs.100) complete as each 844 1783.65 - 15,05,400.60
SUB TOTAL OF SPECIAL REPAIRS ELECTRICAL WORKS 22,62,951.35 4762899.634
SUB TOTAL OF SPECIAL REPAIRS ELECTRICAL WORKS after Applying Cost
Index equivalnt as in 2021( 122.64/118)
NS Subject: Comprehensive Operation and maintenance of 2 nos. sewage treatment plant (1x1500KLD + 1x650KLD) based on SBR technology at GPRA Complex, Kidwai Nagar (East), New Delhi-110023.
comprehensive operation and maintenance of the 2 no. STP plant (1x1500KLD +
1x650KLD) 24*7hours
Maintenace,Repairing including major & minor all type of maintenance and all
instrument installed should be kept in operation and in good health at the per month 36 235562.66 84,80,255.86
satisfaction of Engineer Incharge
Supply of various chemical, consumables etc. for plant operation for 2
nos. sewage treatment plant (1x1500KLD + 1x650KLD) based on SBR
technology at GPRA Complex, Kidwai Nagar (East), New Delhi-110023.
are followings.
Bio Culture Ltr 108 180.00 19,440.00
Sodium Hypo Chloride Ltr. 64800 12.00 7,77,600.00
Salt for Softener KG 144000 5.50 7,92,000.00
Multi grade filter( Media), once in 2 years Kgs. 39000 5.00 1,95,000.00
Pebble & Gravel for Activated carbon filter, once in 2 years Kgs. 12000 5.00 60,000.00
Activated carbon for activated carbon filter, once in 2 years Kgs. 6000 50.00 3,00,000.00
Softener Resin, once in 2 years Kgs. 12000 125.00 15,00,000.00
Following items will be replaced in case these are damged and non
repaiable as per direction of Engineer in Chage complete in all respect.
Electrical -spare parts
MCB 2Amp (1-Pole) NOS. 1 350.00 350.00
MCB 6 Amp (1-Pole) NOS. 1 250.00 250.00
MCB 6 Amp (2-Pole) NOS. 1 690.00 690.00
MCB 10Amp (2-Pole) NOS. 1 690.00 690.00
MCB 16Amp (2-Pole) NOS. 1 695.00 695.00
MCB 20Amp (2-Pole) NOS. 1 700.00 700.00
Over Load Relay 5 amp-8 amp NOS. 1 1200.00 1,200.00
Over Load Relay 10 amp-16 amp NOS. 1 1500.00 1,500.00
Over Load Relay 9 amp-15 amp NOS. 1 1100.00 1,100.00
Over Load Relay 4.5 amp-7.5 amp NOS. 1 1000.00 1,000.00
Over Load Relay 3 amp-5 amp NOS. 1 1000.00 1,000.00
Over Load Relay 30 amp-50 amp NOS. 1 2750.00 2,750.00
Over Load Relay 6 amp-10 amp NOS. 1 1250.00 1,250.00
Over Load Relay 0.9 amp-1.5 amp NOS. 1 1150.00 1,150.00
Contactor , 12 amp NOS. 1 1000.00 1,000.00
Contactor , 09 amp NOS. 1 800.00 800.00
Contactor , 16 amp NOS. 1 1100.00 1,100.00
Contactor , 32 amp NOS. 1 3300.00 3,300.00
Contactor , 110 amp NOS. 1 16000.00 16,000.00
Star Delta Timmer NOS. 1 1150.00 1,150.00
PLC with programing NOS. 1 90000.00 90,000.00
Indicating lights , 220 Watt NOS. 1 200.00 200.00
Selector Switchs NOS. 1 250.00 250.00
Mechanical parts & Spares
Blower parts & Spares
Bearing , for 335 m3 blower NOS. 1 4000.00 4,000.00
Bearing , for 480 m3 blower NOS. 1 15000.00 15,000.00
Bearing , for 770 m3 blower NOS. 1 17000.00 17,000.00
Bearing , for 1200 m3 blower NOS. 1 17440.00 17,440.00
Gear set, for 335 m3 blower NOS. 1 18000.00 18,000.00
Gear set, for 480 m3 blower NOS. 1 24000.00 24,000.00
Gear set, for 770 m3 blower NOS. 1 30000.00 30,000.00
Gear set, for 1200 m3 blower NOS. 1 32000.00 32,000.00
Rotor for , 335 m3 blower NOS. 1 20000.00 20,000.00
Rotor for , 480 m3 blower NOS. 1 28000.00 28,000.00
Rotor for , 770 m3 blower NOS. 1 34000.00 34,000.00
Rotor for , 1200 m3 blower NOS. 1 38000.00 38,000.00
Packing for 335 m3 blower NOS. 1 960.00 960.00
Packing for 480 m3 blower NOS. 1 960.00 960.00
Packing for 770 m3 blower NOS. 1 960.00 960.00
Packing for 1200 m3 blower NOS. 1 960.00 960.00
Belt ( flat belt ) for 335 m3 blower NOS. 5 500.00 2,500.00
Belt ( flat belt ) for 480 m3 blower NOS. 5 700.00 3,500.00
Belt ( flat belt ) for 770 m3 blower NOS. 5 750.00 3,750.00
Belt ( flat belt ) for 1200 m3 blower NOS. 5 800.00 4,000.00
Oil seal for 335 m3 blower NOS. 1 2350.00 2,350.00
Oil seal for 480 m3 blower NOS. 1 2350.00 2,350.00
Oil seal for 770 m3 blower NOS. 1 2700.00 2,700.00
Oil seal for 1200 m3 blower NOS. 1 2700.00 2,700.00
Safety valve for 335 m3 blower NOS. 1 4000.00 4,000.00
Safety valve for 480 m3 blower NOS. 1 4000.00 4,000.00
Safety valve for 770 m3 blower NOS. 1 4000.00 4,000.00
Safety valve for 1200 m3 blower NOS. 1 4000.00 4,000.00
NRV for 335 m3 blower NOS. 1 3000.00 3,000.00
NRV for 480 m3 blower NOS. 1 3500.00 3,500.00
NRV for 770 m3 blower NOS. 1 4000.00 4,000.00
NRV for 1200 m3 blower NOS. 1 5000.00 5,000.00
BEARINGs for Pumps & Motors : -
Capacity in Horse Power -
Re-Winding of the Motors -
Capacity in Horse Power -
Bush for Motors -
Capacity in Horse Power -
Shaft for Motors -
Capacity in Horse Power -
Impeller for Pums -
Capacity in Horse Power -
Fan (Backward curve blade) -
Capacity in Horse Power -
Capacity in Horse Power -
Connection Plate -
Capacity in Horse Power -
Connection Box -
Capacity in Horse Power -
Capacity in Horse Power -
Coupling Set (Tyre Coupling) -
Capacity in Horse Power -
Coupling Set (Star Coupling) -
Capacity in Horse Power -
Silicon Seal -
Capacity in Horse Power -
TOTAL OF SUB HEAD-Y CARRIED OVER TO ABSTRACT OF COST - 1,35,92,311
aoc.pdf