| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.3 LAccepted-AOC PLOT NO 14 SHIV COLONY KATI GHATI RAJGARH ROAD ALWER RAJ | ALWAR | ALWAR | RAJASTHAN | L1 | Accepted-AOC L1 | |
| 2 | L2₹12.1 L+₹59,214 (5.16%)Rejected-Finance 503 LAJPAT NAGAR ALWAR RAJ 301001 | ALWAR | RAJASTHAN | 301001 | L2 | Rejected-Finance NOT LOWEST BIDDER | |
| 3 | L3₹12.4 L+₹94,562 (8.24%)Rejected-Finance 2 GA 29 HOUSING BOARD MANU MARG ALWAR 301001 | ALWAR | RAJASTHAN | 301001 | L3 | Rejected-Finance NOT LOWEST BIDDER | |
| 4 | L4₹14.4 L+₹2.9 L (25.6%)Rejected-Finance | L4 | Rejected-Finance NOT LOWEST BIDDER | |
| 5 | L5₹14.6 L+₹3.1 L (27.1%)Rejected-Finance WZ 576 577 NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L5 | Rejected-Finance NOT LOWEST BIDDER |
Tender Value
₹15.7 L
EMD Value
₹31,500
Closing Date
21 Aug 2020, 6:00 pmClosed
GE ALWAR
GE ALWAR
PROVN OF REWIRING AND CHANGE OF LED TUBE AND OTHER SANCTIONED WORK UNDER AGE EM AT ITARANA CANTT ALWAR
2020_MES_362668_1
8936/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
ALWAR
AS PER NIT
3 documents required · 3 mandatory
₹500
GE ALWAR
₹31,500
Yes
6 Oct 2020
24 Jul 2020
24 Aug 2020
24 Jul 2020
21 Aug 2020
8 Aug 2020
24 Jul 2020 - 7 Aug 2020
Amount
Taking down carefully, copper / aluminium unserviceable /perished point wiring any type for light/ fan/ socket or power complete including fittings such as switches, ceiling roses, pendant holders, lamp holders, bracket holders, regulators sockets, light fittings etc, and making good to disturbed surfaces of wall/floor/ceiling etc, complete, all as specified and directed.
M&L for point wiring for one light point controlled by one, one way switch with 1.50 Sqmm two single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including PVC casing & caping with accessories fixed on surface of walls/ceiling by means of PVC sleeves/dash fasteners with cadmium plated screws all as per IS; terminated in & including sunken box concealed in wall for mounting fittings like switches, sockets, regulators etc with and including 3mm thick phenolic laminated sheet top cover for mounting switches, sockets, fan regulators etc complete all as specified.
All as per serial item No. 2 here-in-before but for one fan point controlled by one switch and regulator.
All as per serial item No. 2 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on same board.
All as per serial item No. 2 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on independent board.
All as per description of serial item No. 2.00 here-in-before but for one 3 pin socket outlet 15/16 Amps with 2.50 Sqmm two single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade including 2.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour
S&F switch piano flush type, single pole, one way, 5/6 Amp, 230 Volts complete all as specified and directed.
S&F switch piano flush type, single pole, one way, 15/16 Amp, 230 Volts complete all as specified and directed.
S&F socket outlet for 3 pin, 5/6 Amp, flush type 240 Volt complete all as specified and directed.
S&F socket outlet for 2 in 1, 3 pin 5/6 & 15/16 Amp, flush type 240 Volt complete all as specified and directed.
S&F lamp holder PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
S&F ceiling rose surface Bakelite 65x50mm two or three terminals complete all as specified and directed.
S&F fan regulators electronic step up type socket size and connecting up, ISI marked flush type, 120 watt, 230 volts complete all as specified and directed.
S&F decorative ultra slim round profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient suitable for 16 Watt to 20 Watt with LED tube 6000K of model E-LITE LED Pride Plus and connecting up with and including three core, PVC insulated, sheathed copper conductore cable of required size and length from ceiling rose to fitting complete all as specified & directed. Make :- Havells Cat Part No LHEXBLP7PN1W018 or equivalent of Syska / Crompton Greaves as approved by GE
S&F Adore LED lamp of 9 / 10 Watt including taking down old u/s CFL lamp complete all as specified. Make :- Havells Cat Part No LHLDERHEML8X010 or equivalent of Philips / Crompton Greaves / Wipro / Bajaj / GE
Supply and fixing LED type street DRACO Series light luminaire 20 watt 230 V 50 Hz including all necessary fitting accessories and LED complete, all as specified & directed. Make :- C&S Cat Part No LTESS20WLED or equivalent of Havells / Syska / CG as approved by GE
S&F sheet metal enclosures, double door type, suitable for fixing MCB,s, TPN with 200 Amps rated bus bar, 4 way, 415 volts complete all as specified and directed.
S&F sheet metal enclosures, double door type, suitable for fixing MCB,s, SPN with 200 Amps rated bus bar, 8 way, 240 volts complete all as specified and directed.
S&F MCB 32 Amps, single pole & neutral, 230 Volts complete all as specified and directed.
S&F MCB 6 to 32 Amps, single pole, 230 Volts complete all as specified and directed.
S&F MCB 32 to 63 Amps, Triple pole & neutral, 415 Volts complete all as specified and directed.
S&F 2nd class hard wood rectangular block open recessed of size 60x45x5 cm depth with 3mm thick hylum/Bakelite sheet on top grouted with 4 Nos bolts for DB complete all as specified and directed.
S&F 2nd class hard wood rectangular block open recessed of size 30x25x5 cm depth with 3mm thick hylum/Bakelite sheet on top grouted with 4 Nos bolts for DB complete all as specified and directed.
M&L for sub main wiring with two runs of 6 sqmm (nominal area) size main cable & one run of 4 sqmm size earth continuity conductor, single core, PVC insulated, unsheathed, FRLS with multi-stranded copper conductor, 1100 Volts grade, ISI marked (IS: 694) cables, drawn through & including suitable size of heavy duty PVC conduit ISI marked not less than 25mm dia & conduit fittings/accessories, fixed on surfaces of wall/ceiling complete including dismantling & taking down old unserviceable sub main wiring complete all as specified and directed. Note:- 02 runs of 6 sqmm size, 01 run of 4 sqmm size cable & conduit with accessories shall be measured as one run length for payment purpose.
Excavation in trenches, not exc 1.5 m wide and not exc 1.5 m depth or not exc 10 Sqm on plan and not exc 1.5 m in depth & getting out, for foundations of poles, struts, stays etc. or for laying underground cable etc. in soft/loose soil complete, all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in soft / loose soil back in trenches after cables have been laid and tested complete all as specified and directed.
Removing excavated surplus (soil) obtained from excavation to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete, all as specified and directed.
Supply, laying, jointing and testing XLPE insulated, armoured, heavy duty underground electric cable with stranded aluminium conductor 1100 volts grade cross sectional area 35 sqmm 3½ core laid in trenches, along poles through pipes etc complete all as specified & as directed. (i) Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately. (ii) Road cutting/floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall be inclusive of the above provisions.
M & L for brick work with FLY ASH BRICKS {As per IS-13757 (1993) burnt clay fly ash building bricks}, (OLD SIZE BRICKS) with width equal to the length of the brick laid dry & flat abutted with each other with gap between adjacent bricks not exc 10 mm over UG cable for protection complete all as specified & directed.
M&L dry sand (Tibba sand) and punning for cushioning to under ground cable all as directed. Note :- For the purpose of payment only punned thickness shall be measured.
M&L for Galvanized iron tubing, 40mm bore light grade, ISI marked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls with required size of flat iron (25mmx3mm) clamps, bolts, nuts and washers for protection of LT electric cable complete.
Material and labour for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4 mm dia by means of GI nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate No 3 of SSR Part-I and connection to main switch board/Test point/panel/equipment and testing on cont....
cont.... completion including excavation and earth work in any type of soil, returning filling in, and removal of surplus spoil to a distance not exc 50 metre, charcoal and salt in alternate layer 15 cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering and 15 mm bore 3.00 metre long GI pipe light grade for earth wire protection fixed with poles with two clamps, made from MS flat 25 mmx3mm, bolts, nuts and washers, PCC chamber (1:3:6) type C1, 40mm thick precast RCC cover 1:2:4 type B1 shall be provided on CI frame etc complete including taking down old unserviceable earthing all as specified & as directed.
Supply, Install, Commissioning & Testing ‘SOLAR HOT WATER SYSTEM' (Evacuated Tube Collector) based on direct transferring of heat of capacity 200 LPD complete all as specified & as directed. Make : BHEL / M/S RACOLD THERNO LTD, PUNE/ TATA BP SOLAR SYSTEM / M/S BOSCH LTD, BANGALORE or any of the manufacturer appended on the “List of manufacturers of Evacuated Tube Collector Based Solar Water Heating Systems” circulated by the Ministry of New and Renewable Energy, Govt. of India.
S&F galvanised steel water tubing medium grade of 20mm bore with & including all fittings and fixed complete to walls and ceilings or laid in floors with required size of flat iron (25mmx3mm) clamps complete all as specified and directed.
S&F galvanised steel water tubing medium grade of 25mm bore with & including all fittings and fixed complete to walls and ceilings or laid in floors with required size of flat iron (25mmx3mm) clamps complete all as specified and directed.
S&F 20mm bore Gun metal gate valve with iron wheel head, screwed both ends for iron pipe copmplete all as specified and directed.
S&F 25mm bore Gun metal gate valve with iron wheel head, screwed both ends for iron pipe copmplete all as specified and directed.
M&L for sub main wiring with two runs of 4 sqmm (nominal area) size main cable & one run of 2.5 sqmm size earth continuity conductor, single core, PVC insulated, unsheathed, FRLS with multi-stranded copper conductor, 1100 Volts grade, ISI marked (IS: 694) cables, drawn through & including suitable size of heavy duty PVC conduit ISI marked not less than 25mm dia & conduit fittings/accessories, fixed on surfaces of wall/ceiling complete all as specified and directed. Note:- 02 runs of 4 sqmm size, 01 run of 2.5 sqmm size cable & conduit with accessories shall be measured as one run length for payment purpose.
S&F single pole and neutral enclosure with a two pin and earth plug and socket complete with 01 No. MCB 20 Amp, single pole copmplete all as specified and directed.
S&F 15 mm bore bib tap, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule & fixed complete all as specified and directed.
S&F 500 Litre capacity Rotational moulded polyethylene water storage tanks double layered (cylindrical vertical with closed top) ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. complete as specified in SSR Part-I
S&F PP-R Ball valves (brass insert), high pressure, with polythene float and flynut complete, screwed for iron pipe 20mm bore or brass ferrule and fixed complete all as specified and as directed.
S&F mild steel work as in frame work for water storage tanks and like with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors and similar works of Gde E-165(Fe 290) including welding etc. complete all as specified and directed.
S&F rolled mild steel work as in Plates (plain or chequered) channels. Square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded etc. conforming to Gde E-250 (Fe 410-W) quality `A’ all as specified and as directed.
M&L for PCC 1:2:4 type B2 using 40 mm graded stone aggregate in foundations, filling and mass concrete complete all as specified and directed.
M&L for point wiring for one light point controlled by one, one way switch with 1.50 Sqmm two single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including PVC casing & caping with accessories fixed on surface of walls/ceiling by means of PVC sleeves/dash fasteners with cadmium plated screws, all as per IS and including wooden boxes fixed on wall with and including 3mm thick phenolic laminated sheet top cover for mounting switches, sockets, fan regulators etc complete all as specified.
All as per serial item No. 47 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on same board.
Supply & fixing and testing of exhaust fan of 300mm sweep, 1400 RPM, suitable for SP 230 / 240 volt, 50 Hz AC supply complete with louver shutter including fixing / grouting of frame in wall & cutting opening in wall for exhaust fan and finished the surface with mortar as good as to match with existing surrondings and connecting with & including 3 Nos 1.5 sqmm single core, PVC insulated but unsheathed FRLS 1100 volts grade cable with multi-stranded copper conductor from ceiling rose to fan complete.
Supply & Fixing Evaporative Air Cooler in steel body (Desert Cooler) with propeller type cooler fan with motor (ISI marked) 1400 RPM (4 Pole) three speeds, nominal capacity 4000 Cum/hour, fan size 450mm, type of blade - Plastic (HIP), submersible water pump, filter pads, power consumption - 225 Watts (maximum), electric driven, single phase, 230 Volts, 50 Hz, capacitor 4 mfd, including all accessories, complete all as specified & as directed. Notes :- (i) Filter panels, front, grill and top of the cooler body shall be made of 1.00 mm galvanized steel sheet. The sump tank and rest of the body shall be made of 1.20 mm thick galvanized steel sheet. The galvanised steel sheet shall be ISI marked and shall have zinc coating not less than 100 gms/sqm and shall conform to IS : 277. cont....
cont.... (ii) All internal surfaces including inside of the tank, fan blades, motor body, pump, pump body and frame shall be painted with water resistant paint conforming to IS: 9862. The outer surface of the cooler shall be spray painted with synthetic enamel paint of approved shade/tint. (iii) The desert cooler shall be fitted with adjustable grill with separate on/off switch of 5/6 Amp rating (ISI marked) for cooler fan and water pump and three stage speed regulator (Low, Medium, High) for three speed cooler fan motor. (iv) Suitable nylon bushes shall be provided in the grill for easy and smooth movement of louvers. (v) The filter pads shall contain wood wool. The filter pads shall be fixed over the panel and secured by clamping guard of galvanized wire of 2mm dia (approx.) and net size 100 mm (approx.) cont....
cont.... square/rectangular. The wire guard shall be fixed in the clamps to avoid any sagging. (vi) The drain plug of brass/stainless steel shall be fitted in such a way so as to be able to completely drain the water from the tank. (vii) The inside wiring connection shall be through suitable non-ferrous thimbles and the live contacts of rotary switch shall be protected by suitable enclosure of insulating material. The electrical cords of the motor and the pump shall be sheathed type. (viii) The cooler shall be provided with front filling arrangement and with 3 core copper stranded conductor size 23/0.0076 cable connecting cord (ISI marked) of 2.50 mtrs length fitted with 3 pin moulded plug top of 5/6 Amp rating (ISI marked). (ix) PVC pipe 15mm bore shall be heavy duty high density. cont....
cont.... (x) Overall minimum dimensions including water tank (sump) of the cooler shall be as under :- (a) Width – 660 mm (measured at front side) (b) Height – 860 mm (measured at front side) (c) Depth – 660 mm (d) Height of water tank – 228 mm (xi) Cooler fan with motor and submersible pump shall be of make :- Khaitan / Usha / Bajaj / GEC / Crompton / Orient / Polar / Havells. Makes of other material such as switches, copper cord etc shall be as specified in Particular specifications / Appendices. One year warrenty of pump and fan motor. (xii) Above aspects shall deemed to be included in quoted rates.
ALAKNANDA ENTERPRISES
B.S Constructions
M/S GAURI CONSTRUCTION
Shiv Enterprises
GAR CONSTRUCTIONS
S.S Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .