| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.7 LAdmitted-Finance | ₹14.7 L | L1 | Admitted-Finance |
| 2 | L2₹14.8 LAdmitted-Finance | ₹14.8 L | L2 | Admitted-Finance |
| 3 | L3₹14.9 LAdmitted-Finance | ₹14.9 L | L3 | Admitted-Finance |
| 4 | L4₹15.1 LAdmitted-Finance | ₹15.1 L | L4 | Admitted-Finance |
| 5 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Others-No document physically submitted by the firm as per the web notification |
| Sl No | Description | Qty | Unit | Laxmi Enterprises L4 | D K ELECTRIC WORKS L2 | R.K.DIESEL SERVICE L1 | R N Power System L3 |
|---|---|---|---|---|---|---|---|
| 1.00Servicing of DEA sets of following capacity by replacing the old oil filters, lub oil, flushing testing and commissioning on load by doing following works etc. complete as reqd. | |||||||
| 1.01 | 15 KVA | 37 | Jobs | 4,300 ₹1.6 L | 3,500 ₹1.3 L | 5,000 ₹1.9 L | 3,800 ₹1.4 L |
| 1.02 | 30 KVA | 7 | Jobs | 4,800 ₹33,600 | 4,200 ₹29,400 | 5,500 ₹38,500 | 4,500 ₹31,500 |
| 1.03 | 40 KVA | 5 | Jobs | 5,500 ₹27,500 | 6,500 ₹32,500 | 5,500 ₹27,500 | 5,000 ₹25,000 |
| 1.04 | 62.5 KVA | 1 | Job | 6,500 ₹6,500 | 9,000 ₹9,000 | 10,000 ₹10,000 | 7,000 ₹7,000 |
| 2.00Replacement of choked/damaged Air Filter Element set (Inner & Outer) of the following capacity DG sets i/c testing, commissioning etc. complete as reqd. | |||||||
| 2.01 | 15/20/30 KVA DG sets | 30 | Nos | 800 ₹24,000 | 700 ₹21,000 | 450 ₹13,500 | 300 ₹9,000 |
| 2.02 | 50/62.5/82.5/100/125 KVA DG Set | 10 | Nos | 1,350 ₹13,500 | 800 ₹8,000 | 1,000 ₹10,000 | 500 ₹5,000 |
| 3.00Replacement of existing faulty batteries for the Diesel Engine Alternator sets i/c disconnection of faulty battery and Supply and fixing of following capacity batteries along with battery terminals and leads to the sites directed by the Engineer in charge i/c testing commissioning etc. complete as reqd. - Batteries with Minimum 24 Months Warranty) Note: - The old DG battery shall be retained by the agency and rates may be quoted accordingly. | |||||||
| 3.01 | 12V, 100AH (Make: Exide Drive) | 30 | Nos | 8,800 ₹2.6 L | 9,900 ₹3.0 L | 9,500 ₹2.9 L | 9,000 ₹2.7 L |
Updated dates
Tender Value
₹14.1 L
EMD Value
₹28,154
Closing Date
7 Jan 2026, 5:00 pmClosed
Executive Engineer E
BSNL Electrical Division First Floor Ambedkar Chowk MTE Rohtak
Servicing and repairing of different capacity DEA sets and Misc Electrical Works in various TE and BTS Sites under Distt Sirsa of BA Hisar
2025_BSNL_257029_1
EE/E/BSNL/ED/RTK/2025-26/24
Open Tender
Electrical Works
365 days
Sirsa
Please refer Tender documents.
7 documents required · 7 mandatory
₹590
Yes
AO Cash GMTD BSNL Hisar
₹28,154
Yes
17 Jan 2026
28 Nov 2025
9 Jan 2026
28 Nov 2025
7 Jan 2026
28 Nov 2025
Amount
Servicing of DEA sets of following capacity by replacing the old oil filters, lub oil, flushing testing and commissioning on load by doing following works etc. complete as reqd.
Replacement of choked/damaged Air Filter Element set (Inner & Outer) of the following capacity DG sets i/c testing, commissioning etc. complete as reqd.
15/20/30 KVA DG sets
50/62.5/82.5/100/125 KVA DG Set
Replacement of existing faulty batteries for the Diesel Engine Alternator sets i/c disconnection of faulty battery and Supply and fixing of following capacity batteries along with battery terminals and leads to the sites directed by the Engineer in charge i/c testing commissioning etc. complete as reqd. - Batteries with Minimum 24 Months Warranty) Note: - The old DG battery shall be retained by the agency and rates may be quoted accordingly.
12V, 100AH (Make: Exide Drive)
12V, 130AH (Make: Exide Drive)
Supply and fixing of following capacity batteries for the Diesel Engine Alternator sets along with battery terminals and leads to the sites directed by the Engineer in charge i/c testing commissioning etc. complete as reqd. - Batteries with Minimum 24 Months Warranty) [Theft Cases]
100AH (Make: Exide Drive)
Repairing of DG sets by carrying the suitable spare parts i/c the dismantling the faulty part & installation of new/repaired parts, commissioning, testing complete as reqd. (15/30KVA DGs).
PVC Wire Braided Fuel pipe (Main)
PVC Wire Braided Fuel pipe (Return)
V-Belt
Repairing & servicing of DG Self-starter Motor
Replacement of Static/ SMPS Battery Charger (12 Volt / 10 Amp) [Mahamaya/ SS make]
Repairing & servicing of Radiator
Alternator’s AVR
Hours Meter-230V AC
Diode [Set of 06 Nos]
Rectifier
Door hinges of canopy
Repairing & Calibration of fuel injector from the authorized work shop i/c replacement of minor components, getting the job done, re installation testing commissioning etc. complete as required.
Replacement of following defective/ burnt/ unrepairable/ obsolete items of AMF Control Panel of DEA set i/c dismantling the defective ones, refixing the new items, making connections testing/commissioning etc. as required at site.
Contactor 63Amp 4Pole AC-1 (L&T/TC/SS Make)
MCB 63Amp 4Pole (L&T/Siemens/Schneider/SS make)
Contactor Coil 40Amp -(Schnieder/TC/L&T /SS make)
Contactor Coil 63Amp (Schnieder/TC/L&T /SS make)
GCU (Make-Deepsea/Deif/Procom)
Start/Stop Relay Card compatible with GCU at site)
DC Relay 40Amp-5Pin (OVN/SS make )
Start/Stop Push Button-(vaisno/Salzer make)
12Volt Stop Solenoid Switch-(autolek/SS make)
DC Wiring 1.5mm i/c Ferrules/Lugs etc. supplying/making connections as reqd.
DC Wiring 2.5mm i/c Ferrules/Lugs etc. Supplying/making connections as reqd.
AC Power Wiring 10mm Ferrules/ Lugs etc. supplying/ making connections as reqd.
Battery leads (Copper)
Dismantling of 15/30/40/62.5 KVA make DEA set in silent canopy installed at BSNL BTS / Exchange by opening the DEA set mains cable, charging cable, earth connection, silencer etc. and keeping the set aside ready for transportation etc. as required.
Lifting of disentailed 15/30/50 KVA DEA set with due care with the help of Hydra/crane and placing on the truck/tempo, hired for transportation.
Charges for Transporting the DEA set from one BSNL site to other BSNL site as directed by the engineer in charge with the help of Truck/Tempo with due care etc. complete as req.
26 km to 50 Km
51 Km to 100 Km
Unloading of transported 15/30/50 KVA DEA set on the foundation at BSNL BTS/Exchange with due care from tempo by means of crane/Hydra and placing at the suitable place as directed by the engineer in charge.
ITC of shifted 15/30/50 KVA DEA set by making power connections, control connection, earth connections, testing the set on load etc. complete as required.
Dismantling the existing faulty burnt 15/30 KVA alternator from DG set i/c to and & fro transportation charges from BTS site/TE Exchange to workshop and bringing back at sites etc. complete with chain/pulley /labour charges etc. as required
Rewinding of rotor winding for 15 KVA alternator I/c dismantling the burnt wires, rewinding with super enameled copper wires of suitable gauge, varnishing i/c testing etc.as required
Rewinding of stator winding for 15/30 KVA alternator I/c dismantling the burnt wires, rewinding with super enameled copper wire of Suitable gauge, varnishing i/c testing etc. as required
ITC of 15/ 30 KVA alternator after repairing i/c coupling of engine and alternator making connections etc. testing the DEA set on load at respective sites as required
Checking, tracing out and removing the DG’s faults in TE/BTS as per following distances from district Main Exchange i/c tracing the fault in Engine/alternator/panel/wiring etc. and restoring the Electrical mains/DG Supply as per site requirements.
within (0- 10 KM)
within 25 KM
Between 25KM to 50 KM
Less for dismantled material
D K ELECTRIC WORKS (BID ID -954228)
R N Power System (BID ID -936835)
Laxmi Enterprises (BID ID -955485)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.81 MB
Tendernotice_2.pdf
PDF • 0.73 MB
BOQ_296402.xls
BOQ • 0.39 MB
Download all tender documents and submit your bid