Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.1 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹43.6 L+₹54,392 (1.26%)Rejected-AOC 728 1 JOGIWARA VISHAVKARMA MANDIR ROAD AMBALA CITY | AMBALA CITY | AMBALA | HARYANA | 134003 | L2 | Rejected-AOC L2 | |
| 3 | L3₹44.6 L+₹1.5 L (3.55%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹44.7 L+₹1.6 L (3.75%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | L5₹50.2 L+₹7.1 L (16.5%)Rejected-AOC | L5 | Rejected-AOC L5 |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
25 Mar 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(AFA),Hyderabad
GE(AFA),Hyderabad, Dundigal AFA, Hyderabad - 500 043
PROVISION OF CERTAIN MINOR/ REVENUE WORKS UNDER AGE B/R-II AT AFA HYDERABAD
2023_MES_582902_1
8313/E8
Open Tender
Civil Works
Item Rate
180 days
GE(AFA)
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE(AFA),Hyderabad
₹94,000
Yes
18 May 2023
25 Feb 2023
27 Mar 2023
25 Feb 2023
25 Mar 2023
11 Mar 2023
25 Feb 2023 - 8 Mar 2023
Amount
M& L for Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out Hard / dense soil complete all as specified and directed.
Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50m and making good surface in hard/dense soil complete all as specified and directed by Engineer-in-Charge.
M& L for Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed.
Removing excavated soil exceeding 1.5 km and not exceeding 5.0 Km and depositing where directed within MD land at a level n exc. 1.5 m above the starting point complete all as specified and as directed.
Demolition of RCC of any description and in any position not otherwise specifically provided for and removing debris to a distance exc 1.5km and not exceeding 5km and depositing where directed all as specified and directed.
Demolition of Plain Cement Concrete of any description and in any position not otherwise specifically provided for and removing debris to a distance exc 1.5km and not exceeding 5km and depositing where directed complete all as specified and as directed.
Taking down cement plaster from walls built in cement mortar, etc. including raking out joints, hacking for key, scrubbing down with water, etc. to receive plaster and removing debris to a distance exc 1.5km and not exceeding 5km and depositing where directed all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and removing debris to a distance exc 1.5km and not exceeding 5km and depositing where directed all as specified and as directed.
M&L for Plain cement concrete 1:2:4, Type B2 using 40mm graded stone aggregate as in foundation, filling and mass concrete etc., complete all as specified and directed.
M& L for Plain Cement Concrete 1:4:8 Type D2 ( using 40 mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed.
M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished surfaces of concrete flat complete all as specified and as directed.
M&L for formwork to sides of pillars, posts, struts, piers, columns and stanchions Square, rectangular or polygonal shape for rough finished surfaces of concrete flat all as specified and directed. .
M&L for Reinforced Cement Concrete (1:2:4) type B1 nominal mix (using 20 mm graded stone aggregate) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc complete all as specified and as directed.
M&L Reinforced Cement Concrete 1:1.5:3 nominal mix type A-1 using 20 mm graded stone aggregate as in foundation, including raft, footing, foundation beam, plinth beam, bases for column etc, complete all as specified and directed
M&L Reinforced Cement Concrete 1:1.5:3 nominal mix type A-1 using 20 mm graded stone aggregate in columns, pillars, piers, posts and struts and mass concrete complete all as specified and directed
M & L for TMT bars 10mm dia and over cut to length bent to shape required including cranking bending, spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L for Mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified and directed.
Cutting holes into or through brick walls built in cement mortar and making good in cement mortar 1:3 or Cement Concrete 1:2:4 type B-l as required of superficial area of wall exc 400 Sqcm and n.exc. 0.1 sqm all as specified and directed.
S&F Sructural Steel work in hollow steel sections (Circular/Rectangular/Square) conforming to IS 4923-1997 or IS 1161-1998, Grade St-240 as in framed work for stairs, ladders, walkways etc., inlcuding supports, brackets, braces connceting cleats with necessary welding, bolting etc complete all as specified and as directed.
M& L for Rolled Mild Steel Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment grade conforming to Fe 410 -W (Gde E- 250) quality A, for stairs, ladders landings etc. complete all as specified and as directed.
M & L for Rendering 15 mm thick on fair faces of brick work or concrete surfaces in CM 1:4 finished even & smooth without using extra cement complete all as specified. Note for item No 19 to 22:- The work shall be executed upto 25m height from GL. The contractor should use mechanical equipment like boom lift / crane and/or steel tubular scaffolding for erection of steel structure. Contractor should take care of all necessary precautionary safety measures while execution of work. The rate quoted by the tenderer is deemed to be inclusive of the same and no claim whatsoever on this account is admissible.
M&L for Post Construction Anti Termite Treatment of soil under existing Floors using Emulsion @ one litre per hole, 300 mm apart including drilling and plugging 12 mm dia holes with cement mortar 1:2 (1 cement : 2 Coarse Sand) to match the existing Floors all as specified and directed.
M&L for Post Construction Anti Termite Treatment along the External Wall below concrete or masonry Apron using Chemical Emulsion @ 2.25 Litres per linear metre incl drilling and plugging holes etc in apron all as specified and directed.
M&L for Post Construction Anti Termite to voids in masonry using chemical emulsion one litre per hole, at 300 mm intervals incl drilling holes at 45 degree and replugging them with CM 1:2 (1cement : 2 Coarse sand) to match the Existing Floors all as specified and directed.
M&L for Post Construction Anti Termite Treatment at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre / hole by drilling 6 mm dia holes at a downward angle of 45 degree at 150 mm centre to centre and sealing the same all as specified and directed.
M&L for cutting holes into or through block masonry walls built in cement mortar with superficial area not exceeding 150 Sqcm and making good in CM 1:3 or cement concrete 1:2:4 type B-1 as required all as specified and directed.
M&L for Mild Steel framed work such as grills, gratings, framed guard bars; barred iron doors, gates, ladders, framed balusters, walk ways; railings, framework of water tanks and similar works conforming to Fe Fe 290 Gde E-165 including necessary cutting, welding, bolting etc all as specified and directed.
M&L for Mild steel small article work in Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required; hooks (stay), heavy, for large gates; hook and pintle hinges; large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe 290 Gde E-165 all as specified and directed.
S&F 2 mm thick solid transparent Acrylic Sheet of any colour fixed over grill door including necessary drilling, screwing etc complete all as specified and as directed. Make : Perspex , Crylux, Acrylite, Astariglas, Lucite, Perclax, or equivalent as approved by GE.
M&L for pre-cast cement concrete block masonry with solid blocks exc 10 cm in width, PCC 1:3:6 mix type C-1 using 20 mm graded stone aggregate and setting in cement mortar 1:4 complete all as specified and directed.
Providing, cement concrete type B1(1:2:4) using 20mm graded aggregate in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates and the like including weathering, slightly rounded or chamfered angles and throating, as directed including use of formwork wherever required. (Reinforcement if used shall be measured and paid seperately) all as specified and directed..
M&L for rendering 10 mm in Cement Mortar 1:4 finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-charge.
S&F of Structural Steel work in tubular posts, trusses, rafters, purlins including special shaped washer, cleats etc. using ERW or induction butt welded tubes conforming to IS-1161-1998 grade St.-240 or with holow structural steel sections conforming to IS 4923-1997 Grade St-240 all as specified and directed.
S&F of Rolled Mild steel Plates conforming to Fe 410 -W (Gde-E- 250) quality A, (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment as in base plates, gusset plates, etc complete all as specified and directed.
S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut n exc 5 cm long, dia of neck 11 to 15 mm all as specified and directed.
S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut exc 20 cm long, dia of neck exc 12 and n exc 20 mm all as specified and directed.
S&F Pre painted galvalume aluminium zinc coating GI based corrugated sheet 0.5mm thick of any colour having tensile strength of 550Mpa as in roof covering / cladding to wall with self tapping screws complete all as specified and as directed.
S&F Pre painted galvalume aluminium zinc coating GI based plain sheet 0.5mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall with self tapping screws complete all as specified and as directed.
Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in hard / dense soil all as specified and directed.
ML for Moorum/red bajri filling in floors, laid in layers n exc 15 cm thick, spread, levelled and rammed incl watering all as specified and as directed.
M&L for hardcore of gauge n exc. 63 mm of broken stone boulders, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface all as specified and directed..
M&L for 150 mm thick plain cement concrete 1:4:8 type D2 using 40mm graded stone aggregate as in sub floors, sub base etc all as specified and directed.
M&L for 75 mm thick PCC 1:3:6 type C2 using 40mm graded stone aggregate as in floor sub base etc all as specified and directed by Engr-in-charge.
M&L for 100 mm thick PCC 1:2:4 type B2 using 40mm graded stone aggregate as in floor, sub base etc finishing fair and even to receive topping layer all as specified and directed.
M&L for 20 mm thick wear proof topping as specified (incorporating an approved metallic floor hardener) laid on concrete floors and pavings and finished even and smooth (Except metallic hardener) complete all as specified and directed. Note : Metallic hardener will be measured seperately.
Supply only Metallic floor hardener of approved make all as specified and directed.
S&F 22 mm wide and 3 mm thick Glass dividing strips in Floor inserted in position conform to design all as specified and directed.
M&L for 60 mm thick pressed precast concrete interlocking paver block M-35 grade with grey cement and pigment any shape and size conforming to IS- 15658 - 2006 laid over and including sand filling to an average thickness of 50mm and levelled complete all as specified and directed by Engineer-in-Charge.
Preparation of new steel surfaces of any description over 10 cm in width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed.
M&L for preparation of new steel surfaces and applying two coats of synthetic enamel paint over a coat of red oxide zinc crome primer on Surfaces of any description, not exceeding 10cm in width or girth, not otherwise described complete all as specified and as directed.
M&L for preparation of old painted steel surfaces of any description, not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint etc complete.
M&L for preparation of old painted wood and wood based surfaces of any description, not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparing new surfaces of plastered or unplastered walls and applying two coats of oil bound emulsion distemper over a coat of primer all as specified and directed.
M&L for preparing old plasterd or unplasted wall surfaces and applying one coat of oil emulsion distemper all as specified and directed.
M&L for preparation of new surfaces plastered or unplastered walls and applying two coats of cement base paint over a priming coat all as specified and directed.
M&L for preparing old surfaces of plastered or unplastered walls and applying one coat of cement base paint all as specified and directed.
S&F of Collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with hold fasts and brackets, complete all as specified and directed.
M&L for Compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc, grade confirming to Fe-410- W(Gde-E-250) quality- B all as specified and directed.
M&L for second class hardwood in scantlings clean sawn timber fixed with nails all as specified and directed.
S&F 12 mm thick prelaminated particle board interior grade prelaminated one side with decorative choice lamination and other side balancing white lamination fixed with screws to wooden frame work complete all as specified.
M&L for joint free coloured non skid ceramic tiles 7 to 8mm thick (Square or rectangular) area of each tile exceeding 0.11 sqm but not exc 0.18 Sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including 15mm thick screed bed in CM (1:6) complete all as specified.
M & L for coloured glazed ceramic tiles of size 450x300x7 mm thick in skirting & Dado, set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 10 mm thick rendering or backing coat in cement mortar 1:4 complete all as specified and as directed.
S & F of Armstrong Ceiling Classic Lite 16 mm 600x600 mm , NRC-0.55, grid size m/t 32x24mm, cross Tee of 1200 mm of size 27x24 mm and cross tee of 600 mm of size 25x24 mm and wall angle of size 19x19mm and fixed alround the wall to form a grid of size 600x600.Tiles shall be provided in the formed grid and suspended with 2mm GI wire at every 1200mm intervals C/C all as per manufacturer instruction and as directed by Engr-in-Charge
Taking down carefully light fitting any type size and make after disconnecting electric connection and removing the material from site and making good the disturbed portion of wall/ floor ceiling etc., complete all as specified and directed.
S&F 1 x 40W high efficiency 2'X2' recess mounting LED light fitting with glare free homogeneous illumination including LED driver with all accessories internally pre-wired connecting up with three core twisted flexible copper conductor cable complete all as specified and directed by Engineer-in-Charge. Make : Havells / Phillips / Bajaj / CG / Luker.
Saiansh Associates
M.chandraiahsons
M/s D.Krishna Varma
MCS ENGINEERING CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .