Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹2.3 Cr
EMD Value
₹4.5 L
Closing Date
3 Nov 2025, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Maintenance Superintendent, NAPS
MS office, NAPS, Narora, Bulandshahr, U.P. -203389
Electrical Works of new Environmental Survey Lab Building at NAPS Township, Narora
2025_NPCIL_242365_1
NAPS/CTC/EMU/2025/CPPP/PT/1154
Open Tender
Electrical Works
Item Rate
90 days
Narora
As per Tender documents
3 documents required · 3 mandatory
₹0
₹4.5 L
ENC CTC office
21 Nov 2025
11 Oct 2025
4 Nov 2025
12 Oct 2025
3 Nov 2025
24 Oct 2025
12 Oct 2025 - 19 Oct 2025
21 Oct 2025
12 way power distribution boardd (panel-2) incomer 1. 4 pole, 3 phase 100 amp, 30mA, RCBO- 01 no. Outgoing 1. 20 amp SPN MCB-36 nos.
12 way power distribution board (panel-3) incomer1. 4 pole , 3 phase 100 amp. 30 mA , RCBO-01 no. Outgoing 1. 16 amp. TPN MCB- 8 nos. 2. 10 amp SPN MCB- 12 nos.
12 way power distribution board (panel-4) incomer 1. 4 pole, 3 phase 63 amp, 30 mA , RCBO- 01 no. Outgoing 1. 10 amp SPN MCB - 24 nos. 2. 20 amp SPN MCB- 12 nos.
12 way power distribution board (panel-5) incomer 1. 4 pole, 3 phase , 63 amp, 30 mA, RCBO- 01 no. Outgoing 1. 10 amp SPN MCB- 24 nos. 2. 20 amp SPM MCB - 12 nos. Incomer shall have change over switch for two source of supply.
8 way power distribution board for street light (panel-6) incomer 1. 4 pole, 3 phase , 63 amp, 30 mA , RCBO -01 no. Outgoing 1. 32 amp TPN MCB- 2 nos. 2. 16 amp SPN mcb - 12 nos. Panel shall be equipped with photo cell and timer for ON/OFF operation of street light.
Supply of 14 SWG copper wire
Installation of 14 SWG copper earhing wire along the run of GI conduit including necessary fixing hardware like copper clip and connection to earthig terminals, lighting, junction boxes, various boards, fan as per specification.
4 core x 50 sq. mm AL
4 core x 25 sq. mm AL
4 core x 10 sq. mm CU
4 core x 6 sq. mm CU
4 core x 4 sq. Mm CU
Excavation of cable trenches of required sizes, in all sort of soil at wherever necessary . After excavation & laying the cable, back filing in the scope of contractor.
Supply and spreading of good quality sand 100 mmm below and 100 mm above the cable in the cable treench
Supply & placing of good quality fully burnt bricks of standard size tn the cable trench after cable laying and spreading of sand
4C x 50 SQ mm AL
4C x 25 SQ mm AL
4C x 10 SQ mm CU
4C x 6 SQ mm CU
4C x 4 SQ mm CU
50 SQ mm AL
25 SQ mm AL
10 SQ mm CU
6 SQ mm CU
4 SQ mm CU
With overall diameter upto 25 mm
With overall diameter above 25 mm and upto 50 mm
With overall diameter upto 25 mm
With overall diameter above 25 mm and upto 50 mm
1.5,2.5,4.0,6.0 sq. Mm PVC FRLS wire
Primary wiring points wiring from all Ist. Panels/DB/SB or SB to SB to first light/Fan point using 2 x 2.5 sqmm (phase & neutral) + 1 x 1.5 sqmm (Earth) Cu PVC wires.
Secondary wiring points extending primary circuits to varous light points 2 x 1.5 + 1 x 1.5 sq. Mm Cu PVC wires from primary point.
Supply of modular type switch 6/10A. Make-Anchor/Roma/MK/Legrand/Havells/Clipsal
Supply of modular type swith 16/20A. Make-Anchor/Roma/MK/Legrand/Havells/Clipsal
Supply of moduar type plug socket 6/10A, 5 pin. Make-Anchor/Roma/MK/Legrand/Havells/Clipsal
Supply of moduar type plug socket 16/20A, 6 pin. Make-Anchor/Roma/MK/Legrand/Havells/Clipsal
Supply of modular type step fan regulator 100W, 1M. Make-Anchor/Roma/MK/Legrand/Havells/Clipsal
Supply of modular type plug socket 20A, twin socket, 2M. Make-Anchor/Roma/MK/Legrand/Havells/Clipsal
Supply of modular type mini MCB 25A, single pole, C-type, 1M. Make-Anchor/Roma/MK/Legrand/Havells/Clipsal
Installation of different modular type switches, socket, Fan regulators in duly erected modular box with base frame & cover plate, internal wiring connections shall be in scope of contractor. Make-Anchor/Roma/MK/Legrand/Havells/Clipsal
Supply of 16 Gauge metal concealted /surface bs with modfular plates with base frame of following modules. Make-Anchor/Roma/MK/Legrand/Havells/Clipsal
3 Module
4 Module
6 Module
8 Module
12 Module
16 Module
Installation of metal concealed box/metal box with base frame and its cover plate in the wall.ceiling by making required groove for following modules
3 Module
4 Module
6 Module
8 Module
12 Module
16 Module
LED fixture, 1 x 12-18W (Recess Mounting)
LED fixture, 1 x 4-8W (Recess Mounting) Suitable for Toilet/Bathroom
LED fixture, 1 x 3-9W (Wall/Surface/Mounting) Suitable for Washbasin area
LED fixture, 1 x 12-18W (Wall/Surface Mounting) Suitable for staicase and entrance area
LED fixture, 1 x 6-10W (Wall/Surface Mounting) Bulkhead for outdoor area
Outdoor street light LED fixture 1 x 20-30W
All type of lighting fixtures indicated sr. No. 26.1 to 26.5 at various location of building
Mounting of street light on pole as per specification
Supply of following type 415V AC, 63A 3f AC power receptacle with MCB
Industrial type 415V AC, 63A, 3 f AC power receptacle with MCB
supply of 150mm W x 75 mm H x 2 mm perforated cable tray with cover
supply of 90 mm W X 20 mm H , GI performed cable tray.
supply of 1.1 KV grade, AL, ARMD, 3.5 C X 240 sqmm cable with XLPE insulation and FRLS PVC outer sheath. Make: Polycab / RR cables/ Finolex
supply of 100 W LED flood light. Make: Bajaj/Philips/Crompton Greaves/Wipro/Osram/Syska/Havells
supply of 3C X 2.5 sqmm FRLS TRS cable. Make- Polycab/RR cables/ Finolex
supply of GI clamp for lightning protection
supply of Cable route marker
supply & installation of PVC casing caping.
supply & installation of fan hook
supply & installation of 1 mtr long fan rod.
supply & installation of panel shed
Supply & installation of 200 mm hume pipe for cable laying.
laying and termination of 3C X 2.5 sqmm FRLS TRS cable.
Installation of of GI clamp for lightning protection including supply and installation of anchor fastner
Installation of 50 mm X 6 mm GI strip for lightning protection
Installation of 35 mm X 6 mm GI strip for lightning protection
installation of test link for lightning protection
Installation of 3 mtr length 40mm dia MS rod for lightning protection system with necessary excavation in soil
installation of 150mm W x 75 mm H x 2 mm perforated cable tray with cover along with supply and installtion of cable tray support and anchor fastener.
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.11 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.70 MB
Tendernotice_2.pdf
PDF • 0.02 MB
Tendernotice_3.pdf
PDF • 2.09 MB
BOQ_276582.xls
BOQ • 0.40 MB
TechnicalbidCPPP1154.xls
Additional Documents • 0.19 MB
approvedcorrigendum1154.pdf
PDF • 0.24 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .