| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.2 LAccepted-AOC | L1 | Accepted-AOC lowest and reasonable | |
| 2 | L2₹11.0 L+₹4,125 (0.38%)Rejected-Finance 21 GURUKRIPA PATIL LAYOUT GOPLA NAGAR NAGPUR 440022 | NAGPUR | NAGPUR | MAHARASHTRA | 440022 | L2 | Rejected-Finance not lowest |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
12 Jan 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF NAGPUR
OFFICE OF GARRISON ENGINEER AIR FORCE VAYUSENA NAGAR NAGPUR- 440007
REPAIRS AND CLEANING OF SEWAGE LINES, SEPTIC TANK AND SOAK WELLS IN SMQ AREA AT VSN, NAGPUR
2020_MES_403601_1
GE/NAG/20-21/8414/60
Open Tender
Miscellaneous Works
Item Rate
270 days
GE AF NAGPUR
As per NIT
7 documents required · 7 mandatory
₹500
GE AF NAGPUR
₹20,000
22 Mar 2021
15 Dec 2020
14 Jan 2021
15 Dec 2020
12 Jan 2021
29 Dec 2020
60 days
Amount
Cleaning of blocked sewage line of the following dia by using bamboo sticks or MS rods and revolving with rope inside the sewer line between two manholes and cleaning the sewer line with fresh water including taking out sludge :-
(a) 100 mm dia
(b) 150 mm dia
(c) 200 mm dia
M&L for Blocking up the entry of manholes of any size & depth and pumping out effluent dirty liquid and sludge from bottom of manholes incl. collecting sludge and dirty liquid into closed container and cleaning the manholes with fresh water, after wards opening the inlet of manhole for re-use and lifting the sludge to outside premises, as directed by Engr-in-Charge (the rates quoted shall deemed to be included for transport if reqd).
Cleaning of blockage of GT/NT/FT of any size or any other similar kind of items complete all as specified and directed
Excavation in tr enches n.exc 1.5M wide and N.exc 1.5M in depth for foundation etc or for manholes n.exc 10 Sqm on plan and n.exc 1.5m indepth and getting out in hard/dense soil all as specified and directed by engineer-in-charge
Returning,filling in including spreading levelling,watering and well ramming in layers n.exc 25cm complete all as specified and directed
Removing excavated soil n.exc 50mand depositing where directed at a level n.exc 1.5M above the starting point complete all as specified and directed
M&L PCC in 1:4:8 type D2 using 40 mm graded stone aggregate as in foundation of Manhole complete all as specified and directed
M & for Plain Cement Concrete Type B0 1:2:4 (using 12.5 mm graded granite stone aggregate) in and other similar bands, plinth courses, string courses, copings, kneelers, the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed
M & L Pre cast reinforced cement concrete 1:2:4 type B1 (Using 20mm graded stone aggregate) set in cement mortar 1:4 for man holes and drain cover slab all as specified and directed.
Demolition of brick work or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, pillars etc. complete all as specified and directed
M&L for Brick work with fly ash bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:6 complete all as specified and directed
M&L for 15 mm thick rendering on fair faces of brick or concrete surfaces in cement mortar 1:4 with finished even and fair with out using extra cement with and including water proofing compound @3% by weight of cement all as specified and directed .NOTE- Supply only integal water proofing compounnd shall be measured and paid separately
M&L for 15 mm thick rendering on fair faces of brick or concrete surfaces in cement mortar 1:6 with finished even and fair without using extra cement with and including water proofing compound @3% by weight of cement all as specified and directed . NOTE- Supply only integal water proofing compounnd shall be measured and paid separately
M&L for Mild steel TMT bars 10 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified and directed
Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15 cm thickness.(below or above ground level) complete all as specified and directed
Demolition and breaking up drain pipes 150 mm dia (Salt glazed ware, AC or Reinforced concrete) set in cement mortar complete all as specified and directed
Demolition and breaking up drain pipes 200 mm dia (Salt glazed ware, AC or Reinforced concrete) set in cement mortar complete all as specified and directed
S & F 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed
S & F 110 mm bore PVC (SWR) bends of any radius complete all as specified and directed
M&L Salt glazed stoneware drain pipes of 150 mm dia grade 'A' laid in trenches and jointed in cement mortor 1:1 in proper gradient all as specified and as directed by engineer-in-charge
S & F RCC Class NP 2, 250 mm bore pipes laid and jointed complete with collars complete all as specified and directed
M & L for PCC 1:3:6 type C2 (using 40 mm graded granite stone aggregate) in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for pipes of 250 mm bore complete all as specified and directed
M & L for PCC 1:3:6 type C2 (using 40 mm graded granite stone aggregate) in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for pipes of 150 mm bore complete all as specified and directed
S&F Cast iron soil , waste and vent pipes 100 mm dia in any length with or without ears, with cement joints, laid in trenches or in floors/wall sand cast pipes complete all as specified and directed
S&F CI Bend 100 mm bore (any radius) diminishing pieces or tapers complete all as specified and directed
S&F CI Bend 100 mm bore (any radius) with duck's foot or heel rest complete all as specified and directed
S&F CI Branch pieces, single (equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches complete all as specified and directed
S/F in vitreous china squatting pan of orrisa pattern, size 580X 440 mm white, with integral foot rest 'P' or 'S' trap, including taking down old oneand makiing good to floor complete all as specified and as directed.
Supply only integral water proofing compound confirming to IS -2645-1975 all as specified and as directed.
Asha Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .