Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.6 LAccepted-AOC HOUSE NO 108 WARD NO 08 SHAKTI NAGAR DHAR ROAD UDHAMPUR UDHAMPUR JAMMU KASHMIR 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L1 | Accepted-AOC L1 | |
| 2 | L2₹41.7 L+₹2.9 L (7.44%)Rejected-Finance 53 HOUSING BOARD COLONY PHASE II UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | J K | 182101 | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹44.7 L+₹5.8 L (15.0%)Rejected-Finance C O SECTOR 02 HOUSING COLONY CHANNI HIMMAT JAMMU J K PIN 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | L3 | Rejected-Finance OTHER THAN L1 | |
| 4 | L4₹44.8 L+₹6.0 L (15.4%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN L1 | |
| 5 | L5₹46.3 L+₹7.5 L (19.3%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN L1 |
Tender Value
₹49.5 L
EMD Value
₹99,000
Closing Date
7 Jul 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (Utilities) Udhampur
GE (Utilities) Udhampur PO-Garhi, Pin-182121
Repair/Maint of Security lights at northern part of Garrison under GE (Utilities) Udhampur
2025_MES_713124_1
GE/U-36/2025-26
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (Utilities) Udhampur
AS PER NIT
8 documents required · 8 mandatory
₹500
GE (Utilities) Udhampur
₹99,000
1 Aug 2025
9 Jun 2025
9 Jul 2025
9 Jun 2025
7 Jul 2025
23 Jun 2025
Amount
Supply, Laying, jointing in replacement & testing 1100 Volts grade heavy duty cable PVC tape PVC sheathed 1.5 Sqmm aluminium solid conductor 2 core nominal cross section laid in trenches/fixed to walls/ passing under the roads in existing pipes etc including takind down old UNSV cable, complete all as specefied and directed by Engr-in-charge.
Supply, Laying, jointing in replacement & testing 1100 Volts grade heavy duty cable PVC tape PVC sheathed 2.5 Sqmm aluminium solid conductor 2 core nominal cross section laid in trenches/fixed to walls/ passing under the roads in existing pipes etc including takind down old UNSV cable, complete all as specefied and directed by Engr-in-charge.
Supply, Laying, jointing in replacement & testing 1100 Volts grade heavy duty cable PVC tape PVC sheathed 4 Sqmm aluminium solid conductor 2 core nominal cross section laid in trenches/fixed to walls/ passing under the roads in existing pipes etc including takind down old UNSV cable, complete all as specefied and directed by Engr-in-charge.
S&F in replacement modular box of size 333 x 233 x 120 mm made of FRP inpact resistance plastic & heat resistant materials including MCB SP 6 A, Connector terminal block 4 pole 16 A capacity and fixing to the street light or post top light pole with suitable sizes of clamps, nuts and bolts, complete all as specefied and directed by Engr-in-charge.
S&F in replacement MS bracket for street light fittings made out of 40 mm dia GI pipe of medium grade 1.5 mtr long each bent to required shape & size and fixed to pole with and including flat iron clamps 02 Nos made out of 32x6 mm flat iron including GI Nuts, bolts and washers and painting of clamps and street light brackets with two coat of aluminium paint over a coat of red oxide primer and fittings bracket to street light fittings, complete all as specefied and directed by Engr-in-Charge.
S&F in replacement 250 Watt LED Flood light with pressure die cast aluminium housing & toughened glass with IP-66 degree protection, individual LED's must have peanut lenses for better throw across & along the road with luminarie efficacy of greater than 110 lumen/Watt (Minimum lumen output of luminarie should be 13200 Lumens) color rendering (CRI) of > 75 and co-related color temperature (CCT) of 5700K (+ 500K), The luminarie should have 5 KV surge protection, PF > 0.95, and total harmonic distortion of THD < 10%, voltage range of 140-280V should be provided. Luminarie should have top maintainable driver compartment for easy access to driver during maintenance. The driver used must be a constant current driver with efficiency of > 85%. The manufactures LOGO must be embossed/Engraved in the housing of the luminarie. Manufactures to provide LM80 from source manufacturer and should have adequate testing facilities approved by ministry of science (Govt of India) to provide LM 79 report, complete all as specefied and directed by Engr-in-charge. Make :Wipro (LF30-272-060-57-G1)/Bajaj/Philips.
S&F in replacement 200 Watt LED Flood light with pressure die cast aluminium housing & toughened glass with IP-66 degree protection, individual LED's must have peanut lenses for better throw across & along the road with luminarie efficacy of greater than 110 lumen/Watt (Minimum lumen output of luminarie should be 13200 Lumens) color rendering (CRI) of > 75 and co-related color temperature (CCT) of 5700K (+ 500K), The luminarie should have 5 KV surge protection, PF > 0.95, and total harmonic distortion of THD < 10%, voltage range of 140-280V should be provided. Luminarie should have top maintainable driver compartment for easy access to driver during maintenance. The driver used must be a constant current driver with efficiency of > 85%. The manufactures LOGO must be embossed/Engraved in the housing of the luminarie. Manufactures to provide LM80 from source manufacturer and should have adequate testing facilities approved by ministry of science (Govt of India) to provide LM 79 report, complete all as specefied and directed by Engr-in-charge. Make:Wipro (LF30-272-060-57-XX)/Bajaj/Philips.
S&F in replacement 150 Watt LED Flood light with pressure die cast aluminium housing & toughened glass with IP-66 degree protection, individual LED's must have peanut lenses for better throw across & along the road with luminarie efficacy of greater than 110 lumen/Watt (Minimum lumen output of luminarie should be 13200 Lumens) color rendering (CRI) of > 75 and co-related color temperature (CCT) of 5700K (+ 500K), The luminarie should have 5 KV surge protection, PF > 0.95, and total harmonic distortion of THD < 10%, voltage range of 140-280V should be provided. Luminarie should have top maintainable driver compartment for easy access to driver during maintenance. The driver used must be a constant current driver with efficiency of > 85%. The manufactures LOGO must be embossed/Engraved in the housing of the luminarie. Manufactures to provide LM80 from source manufacturer and should have adequate testing facilities approved by ministry of science (Govt of India) to provide LM 79 report, complete all as specefied and directed by Engr-in-charge. Make : Wipro (LF20-192-060-57-G2)/Bajaj/Philips.
S&F in replacement 120 Watt LED Flood light with pressure die cast aluminium housing & toughened glass with IP-66 degree protection, individual LED's must have peanut lenses for better throw across & along the road with luminarie efficacy of greater than 110 lumen/Watt (Minimum lumen output of luminarie should be 13200 Lumens) color rendering (CRI) of > 75 and co-related color temperature (CCT) of 5700K (+ 500K), The luminarie should have 5 KV surge protection, PF > 0.95, and total harmonic distortion of THD < 10%, voltage range of 140-280V should be provided. Luminarie should have top maintainable driver compartment for easy access to driver during maintenance. The driver used must be a constant current driver with efficiency of > 85%. The manufactures LOGO must be embossed/Engraved in the housing of the luminarie. Manufactures to provide LM80 from source manufacturer and should have adequate testing facilities approved by ministry of science (Govt of India) to provide LM 79 report, complete all as specefied and directed by Engr-in-charge. Make : Wipro-132-060-57-XX/Bajaj/Philips.
S&F in replacement 120 Watt LED street light with pressure die cast aluminium housing & toughened glass with IP-66 degree protection, individual LED's must have peanut lenses for better throw across & along the road with luminarie efficacy of greater than 100 lumen/Watt (Minimum lumen output of luminarie should be 9000 Lumens) color rendering (CRI) of > 75 and co-related color temperature (CCT) of 5700K (+ 500K), The luminarie should have 5 KV surge protection, PF > 0.95, and total harmonic distortion of THD < 10%, voltage range of 140-280V should be provided. Luminarie should have top maintainable driver compartment for easy access to driver during maintenance. The driver used must be a constant current driver with efficiency of > 85%. The manufactures LOGO must be embossed/Engraved in the housing of the luminarie. Manufactures to provide LM80 from source manufacturer and should have adequate testing facilities approved by ministry of science (Govt of India) to provide LM 79 report, complete all as specefied and directed by Engr-in-charge. Make : Wipro-(LRO2-132-XXX-57-G3)/Bajaj/Philips.
S&F in replacement 90 Watt LED street light with pressure die cast aluminium housing & toughened glass with IP-66 degree protection, individual LED's must have peanut lenses for better throw across & along the road with luminarie efficacy of greater than 100 lumen/Watt (Minimum lumen output of luminarie should be 9000 Lumens) color rendering (CRI) of > 75 and co-related color temperature (CCT) of 5700K (+ 500K), The luminarie should have 5 KV surge protection, PF > 0.95, and total harmonic distortion of THD < 10%, voltage range of 140-280V should be provided. Luminarie should have top maintainable driver compartment for easy access to driver during maintenance. The driver used must be a constant current driver with efficiency of > 85%. The manufactures LOGO must be embossed/Engraved in the housing of the luminarie. Manufactures to provide LM80 from source manufacturer and should have adequate testing facilities approved by ministry of science (Govt of India) to provide LM 79 report, complete all as specefied and directed by Engr-in-charge. Make : Wipro-(LR02-102-XXX-57-G2)/Bajaj/Philips.
S&F in replacement 60 Watt LED street light with pressure die cast aluminium housing & toughened glass with IP-66 degree protection, individual LED's must have peanut lenses for better throw across & along the road with luminarie efficacy of greater than 100 lumen/Watt (Minimum lumen output of luminarie should be 6000 Lumens) color rendering (CRI) of > 75 and co-related color temperature (CCT) of 5700K (+ 500K), The luminarie should have 5 KV surge protection, PF > 0.95, and total harmonic distortion of THD < 10%, voltage range of 140-280V should be provided. Luminarie should have top maintainable driver compartment for easy access to driver during maintenance. The driver used must be a constant current driver with efficiency of > 85%. The manufactures LOGO must be embossed/Engraved in the housing of the luminarie. Manufactures to provide LM80 from source manufacturer and should have adequate testing facilities approved by ministry of science (Govt of India) to provide LM 79 report, complete all as specefied and directed by Engr-in-charge. Make :Wipro-(LRO2-671-XXX-57-G3)/Bajaj/Philips.
Supply and fix 15 Watt new generation, Post top lantern, energy saving, enviornmentla friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminarie with high power LEDs with IP-65 degree protection, individual LED's must have peanut lenses for better throw across & along the road with luminarie efficacy of greater than 100 lumen/Watt (Minimum lumen output of luminarie should be 1500 Lumens) color rendering (CRI) of > 75 and co-related color temperature (CCT) of 5700K (+ 500K), The luminarie should have 5 KV surge protection, PF > 0.95, and total harmonic distortion of THD < 10%, voltage range of 140-280V should be provided, complete all as specefied and directed by Engr-in-charge. Make :Wipro-(LPO7-251-XXX-57-CL)/Bajaj/Philips.
Supply and fix 35 Watt new generation, Post top lantern, energy saving, enviornmentla friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminarie with high power LEDs with IP-65 degree protection, individual LED's must have peanut lenses for better throw across & along the road with luminarie efficacy of greater than 100 lumen/Watt (Minimum lumen output of luminarie should be 1500 Lumens) color rendering (CRI) of > 75 and co-related color temperature (CCT) of 5700K (+ 500K), The luminarie should have 5 KV surge protection, PF > 0.95, and total harmonic distortion of THD < 10%, voltage range of 140-280V should be provided, complete all as specefied and directed by Engr-in-charge. Make :Wipro-(LPO7-431-XXX-57-CL)/Bajaj/Philips.
Supply and Fixing 11Watt Fantasy Bollard LB14 Bollard, LB14 Bollard, made of extruded aluminium housing, to redefine landscape with better light quality and enhance architectural dsign, rated IP65, complete all as specefied and directed by Engr-in-charge.
M&L in replacement of Aluminium lugs suitable for 630 sqmm copper cable including taking down the existing unserviceable one, complete all as specified and directed by Engineer-in-charge
Description all as per Ser Item No 16.00 here-in-before but for 500 sqmm, complete all as specefied and directed by Engr-in-charge.
Description all as per Ser Item No 16.00 here-in-before but for 400 sqmm, complete all as specefied and directed by Engr-in-charge.
Description all as per Ser Item No 16.00 here-in-before but for 300 sqmm, complete all as specefied and directed by Engr-in-charge.
Description all as per Ser Item No 16.00 here-in-before but for 185 sqmm, complete all as specefied and directed by Engr-in-charge.
Description all as per Ser Item No 16.00 here-in-before but for 150 sqmm, complete all as specefied and directed by Engr-in-charge.
Description all as per Ser Item No 16.00 here-in-before but for 120 sqmm, complete all as specefied and directed by Engr-in-charge.
Description all as per Ser Item No 16.00 here-in-before but for 95 sqmm, complete all as specefied and directed by Engr-in-charge.
Description all as per Ser Item No 16.00 here-in-before but for 70 sqmm, complete all as specefied and directed by Engr-in-charge.
Description all as per Ser Item No 16.00 here-in-before but for 50 sqmm, complete all as specefied and directed by Engr-in-charge.
Description all as per Ser Item No 16.00 here-in-before but for 35 sqmm, complete all as specefied and directed by Engr-in-charge.
Description all as per Ser Item No 16.00 here-in-before but for 25 sqmm, complete all as specefied and directed by Engr-in-charge.
Description all as per Ser Item No 16.00 here-in-before but for 16 sqmm, complete all as specefied and directed by Engr-in-charge.
Description all as per Ser Item No 16.00 here-in-before but for 10 sqmm, complete all as specefied and directed by Engr-in-charge.
Dismantling of unserviceable steel tubular pole swaged pole/PCC pole including PCC complete with acessories, complete all as specified and directed by Engr-in-Charge.
Dismantling of old unserviceable/broken/jointed ACSR conductor or earth wire from poles and removing from site of work, complete all as specefied and directed by Engr-in-charge.
Taking down existing old cross arms of MS channel or angle sections etc, complete all as specefied and directed by Engr-in-charge.
Cleaning the existing exposed surfaces of steel tubular pole of 9.0 mtr long including cross arms, brackets, clamps etc and painting with two coats of synthetic enamel paint (Aluminium shade) marking five black & white bands at lower portion of pole, each 300 mm wide alternately and marking pole No. with yellow paint on black base at suitable height, complete all as specified and directed by Engr-in-Charge.
Supply, laying, jointing & testing in replacement XLPE insulated, PVC bedded galvanised steel strip or wire armoured electric power cable heavy duty with stranded aluminium conductor 1100 volts grade cross sectional area 10 Sqmm 4 core laind in trenches or passing through pipe or fixed on poles, complete all as specified and directed by Engr-in-Charge.
Description all as per Ser item No 34.00 here-in-before but of size 16 Sqmm 4 core, complete all as specefied and directed by Engr-in-charge.
Description all as per Ser item No 34.00 here-in-before but of size 25 Sqmm 4 core, complete all as specefied and directed by Engr-in-charge.
Description all as per Ser item No 34.00 here-in-before but of size 35 Sqmm 3.5 core, complete all as specefied and directed by Engr-in-charge.
Taking down the unserviceable LT cable of any size from tranches/ walls /floor etc, complete all as specified and as directed by engineer in charge.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of cables, pipes foundations of poles/stays/pipes etc .not exc 10 Sqm area on plan and getting out in soft/loose soil, complete all as specified and directed by Engr-in-charge
Returning, filling in excavated soil in trenches including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick, complete all as specified and directed by Engr-in-charge.
Removing of excavated soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point, complete all as specified and directed by Engr-in-charge.
S&F double walled corrugated (DWC) pipe of size 77 mm including snap fit coupler conforming to IS14930 (Pt-II)/IS16205 Pt-II for protection of HT cable in under ground, complete all as specefied and directed by Engr-in-charge.. Make: REX/Tirupati Plastomatics Pvt Ltd
M&L for cement concreate 1:2:4 type D-2 (using 40 mm graded stone aggregate) as in coping etc including necessary form work and finishing the surface with cement mortar 1:4, 5mm thick finished to the portion of PCC muffs above ground level, complete all as specified and directed by Engr-in-Charge.
M&L for PCC 1:4:8 type D-2 (using 40 mm grade stone aggregrate in foundation, mass concrate) as in foundation of poles & stay etc, complete all as specified and directed by Engr-in-Charge.
Supply and Laying in replacement Galvanised iron steel tubes, ISI marked light grade of size 40 mm bore for cable protection along the poles under road under drains, laid in trenches/fixed on walls/poles with suitable clamps bolts nuts etc including taking down of old unserviceble pipe, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement erecting steel tubular swaged poles erected to truly vertical or planted as strut complete with 6mm thick mild steel base plate(300mmx300mm), welded to pole, finial taper plug, bolts, nuts, and screws poles made out of ERW MS tubing conforming to IS-2713 Part-II Type 410 SP-31, 9mtr long including drilling of holes of required size for fixing of cross arms, painting the exposed surfaces of pole with two coats of aluminum paint over a coat of red oxide zinc chrome primer and with two coats of black bitumenous paint internally and portion embedded in concrete, making five black & white bands at lower portion of pole each 300mm wide alternately upto the height and marking pole No. with black paint at suitable height including making two nos holes of suitable size in steel tubular pole by gas welding for passing PVC cable connection from junction box to security lights through pole where junction box to be fitted in pole, complete all as specified and directed by Engr-in-Charge. Note: - Excavation and Earth Work, PCC in foundation shall be measured and paid for separately.
Supply and installation in replecement of Supply and fix steel tubular swaged poles Type 410SP-31(9.0 meter long) Swan Neck Type complete with CI base plate and finial and double swan neck, Including foundation and coping.with necessary Foundation RCC 1:1:5:3 with 8Nos.16 mm dia tor bar as main bars and 8mm dia.Tor bars strips@190mm c/c as this reinforcement shall confirm to IS : 1786 latest edition.The foundation shall extend above surroundings ground/drive way level for 200 mm and have DWC 63 mm dia,PVC sleeve cast foundation for cable entry,Excavation,RCC and reinforcement etc as per manufacturer recommendation and the cost of necessary foundation , steel bars , strip as per Manufacturer instructions, complete all as specefied and directed by Engr-in-charge.
S&F in replacement Power contactor 3 phase 415 Volts, 40 Amps, coil voltage of rating 240 Volts including taking down old unserviceable power contactor, complete all as specefied and directed by Engr-in-Charge.
S&F in replacement Power contactor 4 pole 240 Volts, 30 Amps , coil voltage of rating 240 Volts including taking down old unserviceable power contactor, complete all as specified and as directed by Engr-In-Charge.
Supply only Driver for LED energy saving & enviornment area light fitting > 75 watts security light with active power factor correction (APFC) electronic driver. LED driver 75 Watt with operating voltage between 100-270 V of existing specifications & make, complete all as specefied and as directed by Engr-in-charge.
Supply only Driver for LED energy saving & enviornment area light fitting > 45 watts security light with active power factor correction (APFC) electronic driver. LED driver 45 Watt with operating voltage between 100-270 V of existing specifications & make, complete all as specefied and as directed by Engr-in-charge.
Supply only Surge protection 5 KV devices compatible with industrial & outdoor LED fixtures upto rated power of 45 W & up to 150 W with operating voltage between 100-270 V of existing specifications & make, complete all as specefied and as directed by Engr-in-charge.
S&F in replacement of Battery 12 Volt, 26 Ah of lift , make as per sample, complete all as specified and directed by Engr-in-Charge.
S&F in replacement of Battery 12 Volt, 42 Ah of lift , make as per sample, complete all as specified and directed by Engr-in-Charge.
M&L for carry for carry out Servicing/Calibration of 5KV UPS with 12 Volt 26AH & 42AH Bty Make as per sample, complete all as specified and directed by Engr-in-Charge.
S&F in replacement MS Channel/angle iron/flat iron of required size and bend to shape as cross arms, bracing and support including, MS clamps back plates with bolts, nuts, and washers drilled for insulators including painting two coats of synthetic enemel paint (Aluminium shade) over a coat of red oxide primer, complete all as specefied and directed by Engr-in-charge.
S&F in replacement Aluminium conductor steel reinforced (ACSR) any size on poles, stretched on LT poles without any kink and bends of various sizes complete including fixing to insulator with Aluminium binding wire, complete all as specefied and directed by Engr-in-charge.
S&F in replacement MCCB four pole 63 Amps, 50 Hz with breaking capacity 16KA, Ics = 100% Icu , 415 Volts, Adjustable thermal & Fixed magnetic setting including making all incoming/ outgoing connections, complete all as specified and directed by Engineer in Charge.
S&F Onload change over switch FP 200 Amps, 415 Volt, 4 pole, complete all as specefied and directed by Engr-in-charge.
S&F Onload change over switch FP 100 Amps, 415 Volt, 4 pole, complete all as specefied and directed by Engr-in-charge.
S&F Onload change over switch FP 63 Amps, 415 Volt, 4 pole, complete all as specefied and directed by Engr-in-charge.
M&L in replacement for heat shrinkable End joint for PVC/XLPE insulated armoured cable of size upto 50Sqmm 3.5/4 core, complete all as specified and directed by Engr-in-Charge.
Description all as per Ser item No 62.00 here-in-before but LT cable size of 70 to 150 Sqmm, complete all as specefied and directed by Engr-in-charge.
M&L for road cuttig existing road for crossing of underground electric cable for laying of any size GI tubing including necessary excavation and earth work including repairing the same as per existing with pre mix bituminious carpet, complete all as specefied and as directed by Engr-in-charge. Note: - Width of trench shall be 15 cm and depth shall be upto 30 cm.
M&L for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground (earth pit not less than 2.25 mtr below normal ground level) with top edge plate not less than 1.5 metre below normal ground level connected to galvanized earth wire 4 mm as earthing lead by means of bolts, nuts, chuck nuts and washers of galvanized iron earth lead with 15 cm thick alternate layers of charcoal dust & common salt including PCC pit in PCC 1:2:4 type B-1, RCC cover made out of cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) reinforced with TMT steel bars 8 mm dia @150 mm c/c both ways with suitable handle and angle iron 40x40x5mm frame, GI medium grade watering pipe 20 mm bore and funnel with wire mesh light grade protection pipe 20 mm bore up to main board complete as shown on electrical plate No 3 of MES Sch 2009 (Part-I) and testing on completion, complete all as specified and directed by Engr-in-Charge. Note: - On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction of Engineer-in-charge.
vijay kumar gupta and co (BID ID -3350422)
MAMTA ENTERPRISES (BID ID -3350365)
GURU KRIPA ENTERPRISES (BID ID -3340707)
PREM NATH KHAJURIA AND SONS (BID ID -3341609)
MOHAN LAL AND SONS (BID ID -3341036)
M/S DHARAM & SONS ENTERPRISES (BID ID -3350455)
ARNABH ASSOCIATES (BID ID -3341148)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .