Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.5 LAccepted-AOC SA 15 144 S 1 CHANDAN HERITAGE HAVELIA CHAURAHA SARNATH VARANASI U P 221007 | VARANASI | VARANASI | UTTAR PRADESH | 221007 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹28.6 L+₹6.1 L (27.1%)Rejected-Finance | L2 | Rejected-Finance Being Higher Bidder | |
| 3 | L3₹29.3 L+₹6.8 L (30.2%)Rejected-Finance | L3 | Rejected-Finance Being Higher Bidder | |
| 4 | L4₹29.9 L+₹7.4 L (32.7%)Rejected-Finance RAJEEV NAGAR KUTIA GHUSIYANA KHARIKA TELIBAGH LUCKNOW | LUCKNOW | LUCKNOW | UTTAR PRADESH | L4 | Rejected-Finance Being Higher Bidder | |
| 5 | L5₹33.9 L+₹11.4 L (50.7%)Rejected-Finance | L5 | Rejected-Finance Being Higher Bidder |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
10 Apr 2023, 6:00 pmClosed
GE E/M Lucknow
Garrison Engineer E/M, 36 LBS Marg, Lucknow Cantt, Lucknow (U.P.) PIN 226002
REPAIR/MAINT OF LT CABLE, ELECTRICAL BREAKDOWN INCL FAULT DETECTION, LOCALIZATION AND RECTIFICATION IN UG NETWORK AND OH CONDUCTOR, SWITCH GEAR INCL CONNECTED ITEMS WEST OF MG ROAD AND ADJOINING AREA OF AGE E/M EXT(ELECT) UNDER GE E/M LUCKNOW
2023_MES_585792_1
GE/EM/LKO/EXT(ELECT)/T-80 OF 2022-2023
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Lucknow
As per NIT
8 documents required · 8 mandatory
₹500
GE E/M Lucknow
₹80,000
Yes
19 May 2023
14 Mar 2023
12 Apr 2023
14 Mar 2023
10 Apr 2023
29 Mar 2023
Amount
Testing the cables with high voltage DC testing machine and locating the fault in the cables by fault locating machine to pin point exact position of fault, disconnecting faulty 1100 Volt LT cables of different sizes from both ends, removal of Fault, Re-connections and testing of cables after removal of fault complete all as specified and directed. Note: (a) 1100 Volt LT cable & joints shall be measured and paid for seperately under respective items of schedule. (b) Retrieved old serviceable cable cover/bricks will be laid in trenches for cable protection. If extra PCC cover/bricks and sand required at site shall be measured and paid separately under respective items of BOQs. (c) Excavation and earth work will be measured and paid for seperately under respective items of schedule.
Supply, laying jointing and testing LT UG cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured IS 7098 marked, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 240 sq mm 3.5 core, laid in trench/laid under floor or fixed naked with wall/on wall/in ducts/in GI pipes etc. with and includings MS Clamps, nuts,bolts,washers complete all as specified and directed. (Note- Excation, earth works,and sand cushioning,protection bricks/tiles/blocks and pipe shall be measured and paid seprately under given items).
All as per item No 2 above but size 35 sq mm 3.5 core
All as per item No 2 above but size 120 sq mm 3.5 core
All as per item No 2 above but size 95 sq mm 3.5 core
All as per item No 2 above but size 70 sq mm 3.5 core
All as per item No 2 above but size 50 sq mm 3.5 core
All as per item No 2 above but size 16 sq mm 4 core
All as per item No 2 above but size 10 sq mm 4 core
All as per item No 2 above but size 25 sq mm 4 core
All as per item No 2 above but size 185 sq mm 3.5 core
S&F Cable jointing kit for 1100 V (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core 25 to 50 sqmm XLPE armoured aluminium conductor, complete all as specified and directed.
S&F Cable jointing kit for 1100 V (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core 70 to 95 sqmm XLPE armoured aluminium conductor, complete all as specified and directed.
S&F Cable jointing kit for 1100 V (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core 120 to 185 sqmm XLPE armoured aluminium conductor, complete all as specified and directed.
S&F Cable jointing kit for 1100 V (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core 240 sqmm XLPE armoured aluminium conductor, complete all as specified and directed.
Boring/drilling (Horizontly) manually/mechanically under existing road max 10 M in depth) suitable for passing GI Tubing 40 to 100 mm bore complete all as specified and directed.
Excavation in trenches in soft/Loose soil not exceeding 1.5 mtr deep and not exceeding 1.5 mtr wide and getting out complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete all as specified and directed.
Removing excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed.
M & L for dry Sand cushioning in trenches for protection of cable including watering and consolidation complete all as specified and directed. (Note: Punned thickness shall be considerd for measurment purpose)
M & L for well burnt brick fly ash bricks as per IS 12894 -2002 laying in trenches perpendicular to axis of the cable complete all as specified and directed.
Trimming and cutting of tree branches(not more than 25mm girth) coming across 1100 Volt LT over head line clearing the line around 2m single/both sides and and disposal of branches from site exeeding 50m and not exceeding 250m from site complete all as specified and directed. Note : - (i) Length of span is approx 35 to 45 RM. (ii) Due care is to be given while trimming/cutting the tree branches that there should no damage to over head line conductor/pole. In case due to any negligence, damage is caused to be make good/renewal by the contractor from his own resources and nothing extra is admissible. (iii) All Safety to labourer must be adhered by the contractor during trimming and cutting of tree branches.
Dismetling and taking down old/unsv ACSR conductor any size complete all as specified and directed.
S/F ACSR conductor including jointing with existing conductor and straining on LT pole and proper fastening to pin/shackle insulators with aluminium binding wires and required jumpering connection complete all as specified and directed. (Note :- Size of aluminium conductor as per site requirement will be directed by Engineer-in-Charge).
Dimentling and taking down old/unsv insulator of any type any size from pole/stay complete all as specified and directed.
S&F pin type, porcelain, vitreous, brown, including one galvanised mild steel spindle, two galvanised iron washer and one galvanised iron nut, 100mm height and 65 mm dia for 1100 volts grade complete all as specified and directed.
S&F shackle type,porcelian vitreous white, brown or green insulator including galvanised mild steel straps, washers, insulators bolts ,washer and nuts of size 100 mm height and 115 mm dia for 1100 Volts grade complete all as specified and directed.
S&F Loop type insulator, porcelian vitreous brown of size 65x90mm and clearence hole 16mm complete all as specified and directed.
M&L for restraining of overhead ACSR conductor of any size of 5 conductor on pole after disconnecting all jumpering connection & binding of insulators and redoing all jumpering connection and insulator binding with aluminium conductor providing required T&P complete all as specified and directed.
M&L for restraining of ACSR conductor of any size of 2 conductor on pole after disconnecting all jumpering connection & binding of insulators and redoing all jumpering connection and insulator binding with aluminium conductor providing required T&P complete all as specified and directed.
S&F rigid PVC line spacer, suitable for 5 wire, made from high grade PVC material, distance between phase to phase 300mm, suitable for use with 1100 volts grade including taking down unsv one complete all as specified and directed.
Taking out faulty underground 1100 Volt LT cable of different sizes by excavation and removing bricks of any size and relaying in the same trenches or re routing after rectification of fault or replacing faulty portion of cable with new cable and removing of surplus soil and using new bricks as required. Note: (a) 1100 Volt LT cable & joints shall be measured and paid for seperately under respective items of schedule. (b) Retrieved old serviceable bricks will be laid in trenches for cable protection. If extra bricks and sand required at site shall be measured and paid separately under respective items of BOQs. (c) Excavation and earth work will be measured and paid for seperately under respective items of schedule.
Material and labour disconnecting faulty /burnt end or portion of cable by removing the cable from loop including necessary excavation & earth work , suitable size of thimble LT tap , relaying and reconnecting the cable by removing faulty/burnt portion of cable and preparing fresh terminals for 25 Sqmm 3.5/4 core to 240 Sqmm 3.5 core of LT cable to LT Panel/pole/main switch complete all as specified and directed.
Laying only old bricks obtained from excavation complete all as specified and directed.
S&F MCCB 63 Amps 4 Pole, 25 KA, 415 V, 50 Hz with thermal magnetic setting between 70% to 100% adjustable type including spreder and connected accessories and connecting up in the existing panel location including taking out existing unserviceable MCCB complete all as specified and directed.
All as per item No 35 above but MCCB 100 Amps 4 Pole, 25 KA, 415 V, 50 Hz
All as per item No 35 above but MCCB 125 Amps 4 Pole, 25 KA, 415 V, 50 Hz
All as per item No 35 above but MCCB 160 Amps 4 Pole, 25 KA, 415 V, 50 Hz
All as per item No 35 above but MCCB 200 Amps 4 Pole, 36 KA, 415 V, 50 Hz
All as per item No 35 above but MCCB 250 Amps 4 Pole, 36 KA, 415 V, 50 Hz
All as per item No 35 above but MCCB 400 Amps 4 Pole, 36 KA, 415 V, 50 Hz
S&F isolator 63 Amps 4 Pole, 240/415 V, 50 Hz connecting up in the existing panel location including taking out existing unserviceable MCCB complete all as specified and directed.
S&F isolator 100 Amps 4 Pole, 240/415 V, 50 Hz connecting up in the existing panel location including taking out existing unserviceable MCCB complete all as specified and directed.
Supply and laying in trenches/Floor/road crossing or fixed to Pole/Wall GI pipe light grade ISI marked with fitting of size 40 mm bore for protection of cable including taking down existing pipe complete all as specified and directed.
Supply and laying in trenches/Floor/road crossing or fixed to Pole/Wall GI pipe light grade ISI marked with fitting of size 50 mm bore for protection of cable including taking down existing pipe complete all as specified and directed.
Supply and laying in trenches/Floor/road crossing or fixed to Pole/Wall GI pipe light grade ISI marked with fitting of size 80 mm bore for protection of cable including taking down existing pipe complete all as specified and directed.
Supply and laying in trenches/Floor/road crossing or fixed to Pole/Wall GI pipe light grade ISI marked with fitting of size 100 mm bore for protection of cable including taking down existing pipe complete all as specified and directed.
M&L for cutting of PCC/Hard standing/WBM road not exceeding 20 cm in width not exceeding 30 cm in depth for passing of LT cable and making good of disturbed surface to match with the existing surfaces by using old and new material i.e bitumen/PCC (1:3:6) type C-1 complete all as specified and directed.
S&F 1100 volts grade heavy duty flat twin core cable PVC insulated with stranded aluminium conductor of size 16 sqmm and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension GI wire from pole to pole complete all as specified and directed.
S&F On load change over switch, four pole with sheet metal enclouser advance neutral 400 Amps, 415 V, 50 Hz conforming to IS : 13947 Part-3 connecting up in the existing location including taking out existing unserviceable change over switch complete all as specified and directed.
S&F On load change over switch, four pole with sheet metal enclouser advance neutral 250 Amps, 415 V, 50 Hz conforming to IS : 13947 Part-3 connecting up in the existing location including taking out existing unserviceable change over switch complete all as specified and directed.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .