| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.9 LAccepted-AOC | L1 | Accepted-AOC lowest bidder | |
| 2 | L2₹4.7 L+₹49,368 (11.7%)Rejected-AOC | L2 | Rejected-AOC Other than lowest bidder | |
| 3 | L3₹4.8 L+₹59,778 (14.2%)Rejected-AOC INDEX NO E 108 HQ CWE NO 2 DELHI CANTT J 636 SECTOR 23 SANJAY NAGAR GHAZIABAD UTTAR PRADESH 201002 | GHAZIABAD | UTTAR PRADESH | 201002 | L3 | Rejected-AOC Other than lowest bidder | |
| 4 | L4₹5.0 L+₹78,788 (18.7%)Rejected-AOC HOUSE NO 95 STREET NO 08 JAWAHAR COLONY NEAR LAXMI DAIRY FARIDABAD SECTOR 22 HARYANA 121005 | FARIDABAD | HARYANA | 121005 | L4 | Rejected-AOC Other than lowest bidder | |
| 5 | L5₹5.5 L+₹1.3 L (31.4%)Rejected-AOC E 73 FF GALI NO 17B SADH NAGAR PALAM COLONY NEW DELHI 110045 | SOUTH WEST DELHI | DELHI | 110045 | L5 | Rejected-AOC Other than lowest bidder |
Tender Value
₹7 L
EMD Value
₹14,000
Closing Date
4 Sept 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE I CG
AGE I CG Noida
SERVICING AND MAINTENANCE OF SUMMER APPLIANCES AT DIFFERENT SECTORS UNDER AGE (I) CG NOIDA
2024_MES_663350_1
AGE I CGN 15 24 25
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
AGE I CG NOIDA
E b i
8 documents required · 8 mandatory
₹500
AGE I CG
₹14,000
12 Dec 2024
2 Jul 2024
6 Sept 2024
2 Jul 2024
4 Sept 2024
17 Jul 2024
Amount
Disconnecting electric connection of the split AC cap 2.00 TR from its stabilizer or its electric board and remove the front cover of indoor AC unit and clean it with pressure water including cleaning wire mesh/ brush/nylon brush without spoiling inside area of room, then refixing the front cover of indoor unit split type AC including cleaning of air filter. Remove the outer cover of out door unit and covered the condenser moto with ploythene/ plastic cover so that water shall not be entered in the motor while cleaning the unit with pressure water and applying cleaner solution and clean wire mesh with bursh/nylon brush to the condensing coil of out door unit including greasing of fan motor, checking of complete wiring of ACs and tightening all electrical connection with thimble and reconnecting the electrical connection with DBs, Stabilizer as per site condition, Note - Spares required for replacement will be measured and paid separately
S&F in replacement new Running/ starting capacitors suitable for split AC cap 2.00 TR . Make :- Keltron/ Siemens/ Tibcon/ Sarda.
S&F in replacement new Thermostatic switch suitable for split AC cap 2.00 TR . Make:- utrtol/Siemens /Carrier/ Tibcon/ Sarda.
S&F in replacement new Fan Motor for out door unit suitable for split AC cap 2.00 TR Make:- Ranutrtol/ Siemens/Carrier/Tibcon/Sarda
S&F in replacement new Electronic Display Board suitable for split AC cap 2.00 TR Make :As per OEM
S&F in replacement new Swing Motor suitable for split AC cap 2.00 TR Make :As per OEM
S&F in replacement new evaporator coil copper for split AC cap 2.0 TR Make :As per OEM
S&F in replacement new condencer coil copper for split AC cap 2.0 TR Make :As per OEM
S&F in replacement new copper pipe of size 1/4" for split AC cap 2.0 TR
S&F in replacement new copper pipe of size 3/8" for split AC cap 2.0 TR
S&F in replacement new insulation for pipe of size 1/4" or 3/8" for AC cap 2.0 TR
M&L for Leak test with CO2/Nitrogen gas and arrest leakage with brazing on indoor/oudoor of copper pipe of AC 2.0 TR
M&L for charging refrigerant gas (Mafrom / Floron ) after pressure test to a compressor for split type AC 2.0 TR Capacity
S&F in replacement new nylon air filter cleanable indigenous of suitable size for the split type AC 2.0 TR Capacity complete all as directed.
S&F in replacement new fan blades suitable for condencer motor for the split type air conditioners 2 TR capacity all as directed. Make :As per OEM
S&F in replacement new balance centrifugal blower with motor for the split air conditioners of the 2 TR capacity complete all as directed. Make :As per OEM
S&F in replacement new cord less remote suitable for split AC of capacity 2.0 TR /1.5 TR as directed by Engineer-in-charge Make :As per OEM
S&F in replacement new printed circuit board (PCB) of 2 TR capacity and reconnecting the same with electrical connections for split type AC and complete all as directed. Make :As per OEM
S&F in replacement new printed circuit board (PCB) for inverter AC 1.5 TR capacity and reconnecting the same with electrical connections for split type AC and complete all as directed. Make :As per OEM
S&F in replacement new printed circuit board (PCB) for inverter AC 2TR capacity and reconnecting the same with electrical connections for split type AC and complete all as directed. Make :As per OEM
Disconnecting the electrical connections and remove the split type A/C including copper pipe of capacity 1.5TR/2TR from the existing position and shifting the same to the near location, re-connecting the A/C after making the suitable hole with necessary connections including closing the hole at removed place with brick masonry matching with existing colour all as directed.
Taking down unsv indoor unit and refixing indoor unit 2 Ton Cap after replacing defective copper coil i.e. (evaporator) including cutting brazing leak testing, gas charging reconnecting and testing complete all as specified and directed. Make : LG/Voltas/Blue Star/Carrier
Disconnecting electric connection of the split type AC 1.5 TR from its stabilizer or its electric board and taking out from its position, remove the front cover and outer cover, cleaning it with pressure water including cleaning of wire mesh/ brush/nylon brush with pressure water without spoiling inside area of room including cleaning of air filter, refixing the outer cover and front cover, greasing all moving parts. Checking and reconnecting electrical connection of DBs, Stabilizer,including checking of wiring of ACs as per site condition and tightening all electrical connection with thimble. Note - Spares required for replacement will be measured and paid separately
S&F in replacement new Running / Starting capacitors suitable for split type AC 1.5 ton . Make :- Keltron/ Siemens/ Tibcon/ Sarda.
S&F in replacement new Swing Motor suitable for split type AC 1.5 ton Make :As per OEM
S&F in replacement new copper evaporator coil for 1.5 ton split type AC. Make :As per OEM
S&F in replacement new copper condencer coil for 1.5 ton split type AC. Make :As per OEM
S&F in replacement new Electronic Display Board suitable for split type AC 1.5 ton. Make :As per OEM
S&F in replacement new dual speed blower fan motor 1/5 H.P. by disconnecting all the electrical connections and reconnecting same with electrical connections and testing for the split type air conditioners complete all as directed. Make :As per OEM
S&F in replacement new air filter cleanable indigenous of suitable size for the split type air conditioners of 1.5 ton capacity complete all as directed.
M&L for Leak test with CO2/Nitrogen gas and arrest leakage with brazing of copper pipe split AC 1.50 TR
M&L for charging refrigerant gas (Mafrom / Floron ) after pressure test to a compressor for split type 1.5TR Capacity
M&L for carrying out repairs/maintenance/servicing of water cooler storage type of 40/80,60/120 Litres capacity, flushing of storage tank and chemical cleaning, repair/replaement of unserviceable/ worn out spares and accessores cleaning of drain pipes, float valves, s/s tray, push tap, body frames and base plates fan motor all as specified and directed by Engineer-in-Charge. Note - Spares required for replacement will be measured and paid separately
S&F in replacement new compressor suitable for 40/80,60/120 ltrs water cooler Make: LG/ Blue Star/ Samsung
S&F in replacement new copper condenser coil suitable for 40/80,60/120 ltrs water cooler. Make :As per OEM
S&F in replacement new running/starting capacitor suitable for 40/80,60/120 ltrs water cooler. Make-Keltron/ Siemens/ Tibcon/ Sarda.
S&F in replacement new CP push type Water tap 15 mm size suitable for water cooler storage type of 80/40,60/120 Litres
S&F in replacement new relay suitable for 40/80,60/120 ltrs water cooler. Make :As per OEM
S&F in replacement new door lock with key suitable for 40/80,60/120 ltrs water cooler. Make :As per OEM
M&L for Leak test with CO2/Nitrogen gas and arrest leakage with brazing for 40/80,60/120 ltrs water cooler
Material & labour for charging refrigerant gas after pressure test for 40/80 ltrs water cooler with existing type gas R-22,134a
M&L for carrying out repair/ maintenance/ servicing of Refrigerator of 165 Ltrs,180 ltrs 250 Ltrs and 310 Ltrs cap periodic cleaning, checking of electrical circuit and accessories to make the Refrigerator in good working condition all as specified and directed by Engineer-in-Charge. Make:LG /Godrej Note - Gas charging if required will be measured and paid separately
M&L for Leak test with CO2/Nitrogen gas and arrest leakage with brazing for Refigarator of 180-320 ltr cap
M&L for charging refrigerant gas after pressure test of 180-320 ltr cap Refrigerator with existing type gas R-22,134a
M&L for carrying out repair/ maintenance/ servicing of Deep freezer 320 ltr cap Freezer periodic cleaning, cleaning of water tub and checking of electrical circuit repair/ replacement of unserviceable/worn out spares and accessories to make the Deep Freezer in good working condition all as specified and directed by Engineer-in-Charge. Note - Spares required for replacement will be measured and paid separately Make: Voltas
S&F in replacement new copper condenser coil for Deep freezer 320 ltr cap. Make :As per OEM
S&F in replacement new condenser fan motor for Deep freezer 320 ltr cap. Make :As per OEM
S&F in replacement new thermostate for Deep freezer 320 ltr cap. Make :As per OEM
M&L for Leak test with CO2/Nitrogen gas and arrest leakage with brazing for Deep freezer 320 ltr cap
M&L for charging refrigerant gas after pressure test of Deep freezer 320 ltr cap with existing type gas R-22,134a
S&F in replacement PVC flexible hose of 20 mm dia with all accessorfes fixed on wall/ceiling/roof etc with suitable GI saddles and screws for connecting with split type Air Conditioner as drain pipe complete all as specified and directed.
S&F in replacement Rigid PVC pipe of 20 mm dia with all accessorfes fixed on wall/ceiling/roof etc with suitable GI saddles and screws for connecting with split type Air Conditioner as drain pipe complete all as specified and directed. Make-AKG,Plaza,Prince
Taking down, cleaning and servicing of evaporative desert cooler of capacity of 3000 / 4000 Cum/Hr and refixing the same in original position complete all as directed.
S&F in replacement new fan motor working on 230 Volts 50 Hz 1/7 H.P. and reconnecting the same with electrical connections for the evaporative desert cooler of capacity of 3000 / 4000 Cum/Hr complete all as directed. MAKE: COOL HOME/KHAITAN /CG
S&F in replacement new water pump working on 230 Volts 50 Hz 1/66 H.P. and reconnecting the same with electrical/water connections for the evaporative desert cooler of capacity 3000/4000 cum/hr complete all as directed. MAKE: KHAITAN/CG/COOL HOME
S&F in replacement new Evaporative Cellulose Cooling Pad for the evaporative desert cooler of capacity 3000/4000 cum/ Hr.
DP COMPLEX (BID ID -3072746)
KRISHANA ELECTRIC WORKS (BID ID -3071172)
RND ENGINEERS & CONTRACTORS (BID ID -3080073)
PRASAD ELECTRICALS (BID ID -3081491)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .