Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.4 LAccepted-AOC | L1 | Accepted-AOC Low | |
| 2 | L2₹17.6 L+₹17,839.35 (1.02%)Rejected-AOC LUDHIANA CANAL CIRCLE LUDHIANA | LUDHIANA | PUNJAB | 141001 | L2 | Rejected-AOC High |
Tender Value
₹15.5 L
EMD Value
₹31,069
Closing Date
16 Apr 2024, 12:00 pmClosed
EXECUTIVE ENGINEER
Ropar Canal and Ground Water Division WRD Punjab
ESTIMATE FOR BRIDGE cum FALL AT RD 49300 OF ROHIRA DISTRIBUTARY
2024_WR_120327_1
92/22A/2023-24
Open Tender
Civil Works
Item Rate
30 days
VILL ROHIRA NEAR MALERKOTLA
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
Yes
₹31,069
Yes
16 Jul 2024
14 Mar 2024
16 Apr 2024
14 Mar 2024
16 Apr 2024
14 Mar 2024
Amount
Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with excavated surplus soil. (Depth upto 3 m)
Cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.
Plain/ Reinforced cement concrete in substructure as per drawing and Technical Specification RCC Grade M 25- with batching plant, transit mixer and concrete pump
Plain/Reinforced cement concrete in substructure as per drawing and Technical Specification RCC Grade M 30- with batching plant, transit mixer and concrete pump
Plain/Reinforced cement concrete in substructure as per drawing and Technical Specification RCC Grade M 20- with batching plant, transit mixer and concrete pump
Furnishing and Placing Reinforced/Prestressed cement concrete in superstructure as per drawing and Technical Specification RCC/PSC Grade M-40 (a) For Solid slab super-structureincluding centering and shuttering (i) Height up to 5m
Providing and fixing drainage spout complete as per drawing and Technical specification.
Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications.xvi 160mm o/d pipe of 6 Kgf. / sqcm
Providing and applying two coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ 1 Litre for 2 sqm.
Cautionary sign board 600x600x600mm triangular as per IRC 67- 2012 with high intensity Microprismatic grade retro reflective Sheeting as per ASTM D 4956 – 09 and as per IRC 67 – 2012. fixed over 3mm thick aluminium Composite material (ACM) sheeting having aluminium skin thickness of 0.25 to 0.3 mm on both sided and fixing the same with suitable size aluminium alloy rivets @ 200 mm c/c to back support frame of 25x25x3mm angle iron supported on a square hollow steel section post 60x60x3.2mmmm conforming to IS 4923 without cost of definition plate firmly fixed to ground in foundation concrete M-25 of size 0.45x0.45x0.60m for vertical post complete as per clause 801 of MORT&H specifications. Supplier shall provide a warranty as per clause 6.9 of IRC 67-2012 for retro reflective sheeting & a certified copy of test reports from an independent test laboratory conforming to clause 6.7 of IRC 67-2012 .(b) Using high intensity Microprismatic grade retro reflective Sheeting Type XI as per ASTM D 4956 09 and as per IRC 67 2012
Informatory sign board 600x600mm square as per IRC 67- 2012 with high intensity Microprismatic grade retro reflective Sheeting as per ASTM D 4956 – 09 and as per IRC 67 – 2012. with retro reflective high intensity Microprismatic grade sheeting fixed over 3mm thick Aluminium Composite Material (ACM) sheeting having aluminium skin thickness of 0.25 to 0.3 mm on both sided and fixing the same with suitable size aluminium alloy rivets @ 200 mm c/c to back support frame of 25x25x3mm angle iron supported on a square hollow steel section post 60x60x3.2mm conforming to IS 4923 without cost of definition plate firmly fixed to ground in foundation concrete M-25 of size 0.45x0.45x0.60m for vertical post complete as per clause 801 of MORT&H specifications. Supplier shall provide a warranty as per clause 6.9 of IRC 67-2012 for retro reflective sheeting & a certified copy of test reports from an independent test laboratory conforming to clause 6.7 of IRC 67- 2012 .(c) Using high intensity Microprismatic grade retro reflective Sheeting Type XI as per ASTM D 4956 09 and as per IRC 67 2012
Painting new letters and figures of black synthetic enamel paint to an even shade
Plain/reinforced concrete in open foundation complete as per drawing and technical specification. PCC grade M15
Filling expansion jpoint with special bitiminous material for joint size appro 400mm depth and 20mm wide.
Supplying fitiing and placing HYSD bar reinforcement in substructure complete as per drawing and technical specifications.
Any Other Items
DARSHAN SINGH KALER AND COMPANY
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .