| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.8 LAccepted-AOC 16 BAITHAKKHANA ROAD 16 BAITHAKKHANA ROAD SEALDAH BAITHAKKHANA ROAD SEALDAH BAITHAKKHANA ROAD SEALDAH KOLKATA | L1 | Accepted-AOC L1 BIIDER | |
| 2 | L2₹45.4 L+₹78,713 (1.76%)Rejected-Finance AT MAIN ROAD DANDAI PO PS DANDAI DIST GARHWA | LATEHAR | JHARKHAND | 822112 | L2 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 3 | L3₹45.5 L+₹85,325.80 (1.91%)Rejected-Finance COLLEGE ROAD CHABUA PO CHABUA DIST DIBRUGARH ASSAM 786184 | DIBRUGARH | ASSAM | 786184 | L3 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 4 | L4₹46.4 L+₹1.8 L (4.09%)Rejected-Finance | L4 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 5 | L5₹46.8 L+₹2.2 L (5.00%)Rejected-Finance | L5 | Rejected-Finance HIGHER THAN L1 BIDDER |
Tender Value
₹44 L
EMD Value
₹88,000
Closing Date
24 May 2022, 6:00 pmClosed
MAJ JP SAHOO
GE 872 EWS, C/O 99 APO
REPAIRS AND MAINT OF EXTERNAL WATER SUPPLY, REPAIRS/ MAINT TO LT EXTERNAL ELECTRIFICATION AND REPAIRS/ MAINT/ SERVICING OF DG SETS, LT PANELS AND EARTHING AT LIKABALI MIL STN UNDER GE 872 EWS
2022_MES_521770_1
8417/T-17/E8
Open Tender
Electrical and Maintenance Works
Item Rate
274 days
LIKABALI
All as per NIT and Tender documents
7 documents required · 7 mandatory
₹500
GE 872 EWS
₹88,000
Yes
10 Jun 2022
4 May 2022
25 May 2022
4 May 2022
24 May 2022
19 May 2022
4 May 2022 - 7 May 2022
Amount
EARTH WORKS
Excavating in Trenches, not exc. 1.50 Metre Wide and Depth not exc. 1.50 Metre for Taking out/up and Laying of Water Mains, Cables, Electric Poles, etc., Forming Surfaces to required Foundation, etc. and getting out as in Soft/Loose Soil, complete all as specified and as directed.
Excavating in Trenches, not exc. 1.50 Metre Wide and Depth exc. 1.50 Metre but not exc. 3.00 Metre for Electric Poles, etc., Forming Surfaces to required Foundation, etc. and getting out as in Soft/Loose Soil, complete all as specified and as directed.
Returning, Filling in including Spreading, Levelling, Watering, Well Ramming in Layers not exc. 25 Cm, Providing Heaps along the Route of the Water Mains, Cable Lines, etc. with Surplus Soil in Soft/Loose Soil, complete all as specified and as directed.
Removing Excavated Materials (Soils) not exc. 50.00 Metre and depositing where directed at a level not exc. 1.50 Metre above the Starting Point in Soil, complete all as specified and as directed.
Drilling/Making Hole (Horizontally) under Roads/ Hardstanding, etc. by any means suitable for passing GI Tubing 40mm to 80mm bore (dia), complete all as specified and as directed.
M&L Cutting on Existing Road not exc. 0.50 Metre in Depth and not exc. 1.00 Metre in Width including Making Good the Same with Cement Concrete 1:3:6 (40mm graded stone aggregate) 200mm thick on Top Layer after necessary Returning, Filling in, Well Ramming and Levelling in Layers to match the Existing Surface Levels, complete all as specified and as directed. NOTE : Cement Concrete 1:3:6 (40mm graded stone aggregate) 200mm thick will be Measured & Paid separtely under appropriate Item.
REPAIRS & MAINT TO EXTERNAL WATER SUPPLY
Taking up or down Steel Tubing 25mm bore (dia) and Connections/ Fittings of any description, complete all as specified and as directed.
Taking up or down Steel Tubing 32mm bore (dia) and Connections/ Fittings of any description, complete all as specified and as directed.
Taking up or down Steel Tubing 50mm bore (dia) and Connections/ Fittings of any description, complete all as specified and as directed.
Taking up or down Steel Tubing 63mm bore (dia) and Connections/ Fittings of any description, complete all as specified and as directed.
Taking up or down Steel Tubing 90/100mm bore (dia) and Connections/ Fittings of any description, complete all as specified and as directed.
Supply & Laying PP-R (Polypropylene Random Copolymer) 3 layer Pipe SDR 7.4 (PN 16) and Fittings 25mm bore (dia) having Inner with Anti-microbial Property and Outer Green Coloured, UV Stabilize Property Fusion welded having Thermal Stability for Hot and Cold Water Supply including PP-R Plain and Brass threaded Poypropylene Random Fittings and required for fixing to Walls or laid in Floor/ Ground and Testing of Joints as per Manufactures instruction, complete all as specified and as directed.
Supply & Laying PP-R (Polypropylene Random Copolymer) 3 layer Pipe SDR 7.4 (PN 16) and Fittings 32mm bore (dia) having Inner with Anti-microbial Property and Outer Green Coloured, UV Stabilize Property Fusion welded having Thermal Stability for Hot and Cold Water Supply including PP-R Plain and Brass threaded Poypropylene Random Fittings and required for fixing to Walls or laid in Floor/ Ground and Testing of Joints as per Manufactures instruction, complete all as specified and as directed.
Supply & Laying PP-R (Polypropylene Random Copolymer) 3 layer Pipe SDR 7.4 (PN 16) and Fittings 50mm bore (dia) having Inner with Anti-microbial Property and Outer Green Coloured, UV Stabilize Property Fusion welded having Thermal Stability for Hot and Cold Water Supply including PP-R Plain and Brass threaded Poypropylene Random Fittings and required for fixing to Walls or laid in Floor/ Ground and Testing of Joints as per Manufactures instruction, complete all as specified and as directed.
Supply & Laying PP-R (Polypropylene Random Copolymer) 3 layer Pipe SDR 7.4 (PN 16) and Fittings 63mm bore (dia) having Inner with Anti-microbial Property and Outer Green Coloured, UV Stabilize Property Fusion welded having Thermal Stability for Hot and Cold Water Supply including PP-R Plain and Brass threaded Poypropylene Random Fittings and required for fixing to Walls or laid in Floor/ Ground and Testing of Joints as per Manufactures instruction, complete all as specified and as directed.
Supply & Laying PP-R (Polypropylene Random Copolymer) 3 layer Pipe SDR 7.4 (PN 16) and Fittings 90mm bore (dia) having Inner with Anti-microbial Property and Outer Green Coloured, UV Stabilize Property Fusion welded having Thermal Stability for Hot and Cold Water Supply including PP-R Plain and Brass threaded Poypropylene Random Fittings and required for fixing to Walls or laid in Floor/ Ground and Testing of Joints as per Manufactures instruction, complete all as specified and as directed.
S&F PP-R (Polypropylene Random Copolymer) Gate Valve 25mm bore (dia), Brass insert with Wheel Head, screwed both Ends including Taking down/ out Unserviceable Gate Valve of any description, complete all as specified and as directed.
S&F PP-R (Polypropylene Random Copolymer) Gate Valve 32mm bore (dia), Brass insert with Wheel Head, screwed both Ends including Taking down/ out Unserviceable Gate Valve of any description, complete all as specified and as directed.
S&F PP-R (Polypropylene Random Copolymer) Gate Valve 40mm bore (dia), Brass insert with Wheel Head, screwed both Ends including Taking down/ out Unserviceable Gate Valve of any description, complete all as specified and as directed.
S&F PP-R (Polypropylene Random Copolymer) Gate Valve 50mm bore (dia), Brass insert with Wheel Head, screwed both Ends including Taking down/ out Unserviceable Gate Valve of any description, complete all as specified and as directed.
M&L Cast Iron Sluice Valve 80mm bore (dia), Operation-cap, both sides Flanged, ISI Marked (IS:14846-2000 & Class PN 1.6) having Cast Iron Hand Wheel, Brass Spindle, Cheek Nuts and Sliding Gate and Body with Mild Steel Bolts & Nuts and Testing against Leakage including Taking out/ down Unserviceable Sluice Valve, complete all as specified and as directed.
M&L Cast Iron Sluice Valve 100mm bore (dia), Operation-cap, both sides Flanged, ISI Marked (IS:14846-2000 & Class PN 1.6) having Cast Iron Hand Wheel, Brass Spindle, Cheek Nuts and Sliding Gate and Body with Mild Steel Bolts & Nuts and Testing against Leakage including Taking out/ down Unserviceable Sluice Valve, complete all as specified and as directed.
M&L Construction Brick Masonry Valve Chamber of Size 60x60x60 Cm (Internal Dimension of Chamber) with Cement Concrete 1:4:8 (40mm graded stone aggregate) 100mm thick in Foundation, One Brick thick Brick Walls in Cement Mortar 1:4, Rendering 15mm thick on Brick Walls in Cement Mortar 1:4 and all Internal Surfaces except PCC Foundation Bed, Externally upto 150mm below Normal Ground Level, providing Mild Steel Valve Chamber Cover 3.15mm thick with Hinges, Handle and Locking Arrangements with Mild Steel Angle Iron Frame 40x40x5.0mm on Top of Valve Chamber, Angle Iron Frame embedded in Cement Concrete 1:2:4 (20mm graded stone aggregate) 100mm thick including applying Two Coats of Black Synthetic Enamel Paint over a coat of Red Oxide Zinc Chrome Primer after necessary preparation to all Steel Surfaces Painting, all necessary Earth Work i.e. Excavation in any type of Soil, Returning, Filling in and Removal of Surplus Soil to a distance not exc. 50.00 Metre including Demolition of Damaged Valve Chamber, complete all as specified and as directed.
M&L Construction Brick Masonry Valve Chamber of Size 100x100x100 Cm (Internal Dimension of Chamber) with Cement Concrete 1:4:8 (40mm graded stone aggregate) 100mm thick in Foundation, One Brick thick Brick Walls in Cement Mortar 1:4, Rendering 15mm thick on Brick Walls in Cement Mortar 1:4 and all Internal Surfaces except PCC Foundation Bed, Externally upto 150mm below Normal Ground Level, providing Mild Steel Valve Chamber Cover 3.15mm thick with Hinges, Handle and Locking Arrangements with Mild Steel Angle Iron Frame 40x40x5.0mm on Top of Valve Chamber, Angle Iron Frame embedded in Cement Concrete 1:2:4 (20mm graded stone aggregate) 100mm thick including applying Two Coats of Black Synthetic Enamel Paint over a coat of Red Oxide Zinc Chrome Primer after necessary preparation to all Steel Surfaces Painting, all necessary Earth Work i.e. Excavation in any type of Soil, Returning, Filling in and Removal of Surplus Soil to a distance not exc. 50.00 Metre including Demolition of Damaged Valve Chamber, complete all as specified and as directed.
Dismantling Unserviceable/ Rusted Members of Mild Steel Work of any description from Pressed Steel Overhead Tank of Size 5.00x5.00x2.00 Metre having 10000 Gallon (45000 Litre) Capacity at 15.00 Metre High Staging by unscrewing Mild Steel Bolts, Nuts, Washers, etc. after Disconnecting Rising Mains, Delivery and Drain Pipes, complete all as specified and as directed.
M&L Mild Steel Angle Iron 40x40x6.0mm to 65x65x6.0mm as Frame Work (Supports, Cross, etc.) of Pressed Steel Overhead Tank 15.00 Metre High Staging and Similar Work, conforming to Fe-290, Gde E-165 and fixing with Mild Steel Bolts, Nuts, Washers, etc., complete all as specified and as directed. NOTE : Mild Steel Bolts, Nuts, Washers, Gasket, etc. will be Measured & Paid separately under appropriate Item.
M&L Pressed Steel Plates of Size 1225x1225x6.0mm thick (or nearest Size), Factory moulded/shaped as Bottom and Side Walls of Pressed Steel Overhead Tank 15.00 Metre High Staging and similar work, conforming to IS, Making Leak Proof with Lead Wools, Rubber Gaskets, Mild Steel Bolts, Nuts, Washers, etc., complete all as specified and as directed. NOTE : Cost of Lead Wools and Other Jointing Materials (as required/ ordered) will deem to be included in the Quoted Unit Rate. However, Mild Steel Bolts, Nuts, Washers, Rubber Gaskets, etc. will be Measured & Paid separately under appropriate Items.
M&L Mild Steel Sheets 3.15mm thick as Top Cover of Pressed Steel Overhead Tank 15.00 Metre High Staging and similar work, conforming to IS, Fixing with Mild Steel Bolts, Nuts, Washers, Hinges, etc., complete all as specified and as directed. NOTE : Cost of Mild Steel Hinges (as required/ ordered) will deem to be included in the Quoted Unit Rate. However, Mild Steel Bolts, Nuts, Washers, etc. will be Measured.
M&L Mild Steel Box of Size 200x200x130mm, made out of 8.0mm thick Mild Steel Plates, conforming to Fe-290, Gde E-165, providing Holes for fixing Mild Steel Angles, etc, complete all as specified and as directed.
M&L Mild Steel Screw Bolts, Machine made (Size of Bolt as per Site requirment /as ordred) with Hexagonal or Square Heads at One End and screwed the Other, or screwed Both Ends, Each screwed End to be fitted with 3.0mm thick Washers and One Hexagonal or Square Nut, complete all as specified and as directed.
S&F Rubber Gasket 6.0mm thick (sizes of Rubber Gasket as per Site requirment /as ordred), complete all as specified and as directed.
Supply only Calcium Hypo Chlorite (Altock GP/ Aquafit) 65%-70% Chlorine content (Calcium based Granular Disinfectant for Water Treatment (as approved by GE) for Chlorination of Water i.e. 2 PPM at Pump House and 0.2 PPM at User End, complete all as specified and as directed. NOTE : Manufacturer's Test Certificate for Each Lot alongwith Original Purchase Voucher shall be furnished by the Contractor for Payment.
Supply only Bleaching Powder for Water Treatment (as approved by GE) for Chlorination of Water i.e. 2 PPM at Pump House and 0.2 PPM at User End, complete all as specified and as directed. NOTE : Manufacturer's Test Certificate for Each Lot alongwith Original Purchase Voucher shall be furnished by the Contractor for Payment.
M&L Preparing & Removing Rusts, etc. from Steel Surfaces of Pressed Steel Overhead Tank 46800 LITRE Capacity having 15.00 Metre High Steel Stagging by Rubbing with Wire Brush, Cleaning completely and Applying One Coat of Black Bituminous Paint (suitable for Drinking Water purpose) to Inside Walls of Storage Water Tank and all Connected Assesories like all GI Pipes, Valves, Other Fittings, etc., complete all as specified and as directed.
M&L Cleaning existing Water Sump of 42000 LITRE Capacity by carrying out the following Works, complete all as specified and as directed :- (a) Dewatering the Sump by employing "Tulu Pump and Man Power" (b) Removing the Sludge, Muddy and dissolved Iron Water from the Sump by employing Man Power and required Tools. (c) Scrubbing the Algae from Walls, Corners etc completely by using Wire Brush and Man Power. (d) Washing the Walls, Bottom and all Conrners by Bleaching Powder. NOTE : All Materials and Labours such as Bamboos, Munj or other Equip-ments are required for Cleaning Sump shall arranged by the Contractor from his own Sources and Arrangement for which Cost of the same shall deemed to be included in the Quoted Unit Rate. No any Extra Amount shall be Paid separately on this account.
M&L Cleaning existing Water Sump of 80000 LITRE Capacity by carrying out the following Works, complete all as specified and as directed :- (a) Dewatering the Sump by employing "Tulu Pump and Man Power" (b) Removing the Sludge, Muddy and dissolved Iron Water from the Sump by employing Man Power and required Tools. (c) Scrubbing the Algae from Walls, Corners etc completely by using Wire Brush and Man Power. (d) Washing the Walls, Bottom and all Conrners by Bleaching Powder. NOTE : All Materials and Labours such as Bamboos, Munj or other Equip-ments are required for Cleaning Sump shall arranged by the Contractor from his own Sources and Arrangement for which Cost of the same shall deemed to be included in the Quoted Unit Rate. No any Extra Amount shall be Paid separately on this account.
REPAIRS & MAINT TO PUMPS AND MOTORS
M&L Lifting of Submersible Pump & Motor Assembly 12.5 HP capacity alongwith complete Column Pipes, Submersible Cable, Safety Rope, etc. from the existing Borewell by employing Chain Pulley Block, etc., Dismantling Column Pipes by Opening Nuts, Bolts, Pump & Motor, etc, Segregating & Stacking of Serviceable Column Pipes & Other Materials and Keep in Safe Custody for re-use, complete all as specified and as directed.
M&L Removing Submersible Pump & Motor Assembly 12.5 HP capacity to AGE E/M Store Yard at LIKABALI, Opening/Dismantling & Checking in presence of a Board of Officers to ascertain the quantum of Defects and Repair Works involves, Cleaning of Cover and Parts as required, Transporting defective Submersible Pump & Motor Assembly to nearest Workshop, Repairing & Replacing of Unserviceable Parts, Reassembling Submersible Pump Motor Assembly after repaired, Transporting repaired Submersible Pump Motor Assembly back to Work Site, complete all as specified and as directed. NOTE :- (a) Spare Parts required to be replace will be Measured and Paid as "Supply only" under relevant Items. Cost of Labour Element involved for replacement of Parts will deem to include in the Quoted Unit Rate. (b) Any Minor repairs involved to make the Submersible Pump & Motor Assembly Functional, even if not notified by the Board of Officers, the same will be carry out by the Contractor without any Extra Cost to the Department. (c) The Cost of Minor Spares Parts/Items viz Nuts, Bolts, Washers, Gasket, etc. will deem to be include in the Quoted Unit Rate. (d) Rewinding of Submersible Motor, wherever invloves will be Measured and Paid separately under relevant Item.
M&L Taking out burnt Windings from Submersible Pump & Motor 12.5 HP capacity, Cleaning of Slots of the Motor and Rewinding the same with Super Enamel Copper insulated Wire of suitable Gauge and Weight as per existing including necessary Insulation Materials, Varnishing, Heating, Reassembling the Same and Testing for Smooth Functioning after Rewinding, complete all as specified and as directed.
Supply only Valve Casing, 'O' Ring, Valve Cup, Valve Seat, Upper & Lower Valve Seat Retainer (as per Site Requirment/ as Ordered), complete all as specified and as directed.
Supply only Valve Guide, Rivet, Connecting Piece, Top Chamber, Upthrust Disc, Top Bearing (as per Site Requirment/ as Ordered), complete all as specified and as directed.
Supply only Neck Ring, Split Cone, Impeller, Nuts and Bolts (as per Site Requirment/ as Ordered), complete all as specified and as directed.
M&L Lowering down Submersible Pump & Motor Assembly 12.5 HP capacity (after Repaired & Testing of Functionability) alongwith Column Pipes of any Size and Length, Submersible Cable, Steel Wire Rope, etc. with the help of Chain Pulley Block and Tool & Plants, Testing on Completion, complete all as specified and as directed. NOTE : Serviceable Column Pipes and Other Materials, etc. obtained from Item No. 3.01 here-in-before will be reused.
M&L Deluxe Automatic Star Delta Starter suitable for 12.5 HP Motor (as per existing as approved), fixing to Existing Panel Board with necessary Fixing Arrangements and Providing all Electric Connections including Taking down/out Unserviceable Star Delta Starter from Panel Board, complete all as specified and as directed. MAKE : HAVELLS Cat No. IHPASDMB* or Make as approved by GE
REPAIRS & MAINT TO LT EXTERNAL ELECTRIFICATIONS
Dismantling Unserviceable Steel Tubular Pole of any description and any size including Demolition Cement Concrete (if required on Ground) and Made Good disturbed Ground, complete all as specified and as directed. NOTE : Unserviceable Pole will be dismantled at Ground Level and disturbed Ground will Made Good as directed for which Earthwork, Demolition Cement Concrete, etc. will not be Measured and Paid separately.
Taking down Unserviceable Insulator of any size and any description from LT Electric Poles or from any Situations, complete all as specified and as directed.
Dismantling Cross Arms, Mild Steel Channel, Angle Section, Flat Iron, Mild Steel Rod, etc., complete all as specified and as directed.
Taking down ACSR Conductor including Line Spacers of OH Electric Lines from LT Electric Poles of any Size including Separators, etc., complete all as specified and as directed.
Taking down Unserviceable/ Rusted GI Earth Wire, Cradles Guards of any size and shape at any Position from LT Electric Poles of any Size, complete all as specified and as directed.
Dismantling Unserviceable LT Stay Assembly Complete Set of any description, complete all as specified and as directed.
M&L Cement Concrete 1:4:8 (40mm graded stone aggregate) in Foundation, Filling and Mass Concrete, etc. including Use and Waste of Formwork as required/ ordered, complete all as specified and as directed.
M&L Cement Concrete 1:3:6 (40mm graded stone aggregate) in Foundation, Filling and Mass Concrete, etc. including Use and Waste of Formwork as required/ ordered, complete all as specified and as directed.
M&L Cement Concrete 1:2:4 (20mm graded stone aggregate) in Copping of Electric Poles, etc., weathering slightly rounded or chamfered angle and throating, finishing all Exposed Faces of Concrete including necessary Formwork, complete all as specified and as directed.
M&L Steel Tubular Swaged Pole Type 410 SP-31 (9.0 Metre long) complete with Mild Steel Base Plate, Finial Taper Plug, Bolts, Nuts & Screws, etc. as specified including One coat Aluminium Paint over One Coat of Red Oxide Zinc Chrome Primer, providing 3 No. Band/ Strap with Paint Black/ Yellow Colour 300mm apart from Plinth Block and numbering of Pole/ Painting embedded portion of Pole with One coat of Bituminous Paint, complete all as specified and as directed. NOTE : Necessary Earth Work & PCC will be Measured and Paid separately under relevent Items.
M&L Cross Arms, Bracings, Supports, Clamps and Back Plates, fabricated from Structural Steel Sections including Nuts, Bolts, Washers, etc., welding, bending cold or hot, drilling holes for Bolts, in any shape or size as indicated or directed and applying Two Coats of Aluminium Paint over a Coat of Aluminium Oxide Primer after preparation of Surfaces, complete all as specified and as directed.
S&F Insulator Pin type, 100mm height, 65mm dia for 1100 Volt grade, Porcelain, Vitreous, white, brown or green including One Galvanised Mild Steel Spindle Two Galvanised Iron Washer and One Galvanised Iron Nut, complete all as specified and as directed.
S&F Insulator Shackle type, Porcelain, Vitreious, white brown or green of size 100mm High & 115mm dia including Galvanised Mild Steel Straps of Section 31x5.0mm, 14mm dia Insulator Bolts, Nuts, Washer, etc. for Working Pressure 1100 Volt grade, complete all as specified and as directed.
S&F Insulator Loop type, Small in size, Vitreous Porcelain, white, borwn or green with Overall Dimensions 65x90mm, Clearance of Hole 16mm 1100 Volt grade, complete all as specified and as directed.
M&L ACSR Conductor of any Size for LT Over Head Line including Stringing Conductor fixed on Poles and binding with Aluminium Binding Wire, etc., complete all as specified and as directed. NOTE : Sizes of Conductor will be as per Site requirement/ as directed.
M&L Restretching, Tightening & Fixing of ACSR Conductor of any size on LT Electric Poles including necessary Aluminium Binding Wire including Refixing of Connectors, PVC Sleeves for Jumper, etc. complete all as specified and as directed.
S&F PVC Fibre Separator for LT Line 1100 Volt Over Head Conductor 3 - 4 Wire System for Horizontal Spacing of Conductor complete with Nut and Bolts minimum 2 No. to prevent the Lines Touching Each Other on Heavy Winds as a Preventive Arrangement to the Existing System, complete all as specified and as directed.
S&F PVC Fibre Separator for LT Line 1100 Volt Over Head Conductor 5 - 6 Wire System for Horizontal Spacing of Conductor complete with Nut and Bolts minimum 2 No. to prevent the Lines Touching Each Other on Heavy Winds as a Preventive Arrangement to the Existing System, complete all as specified and as directed.
M&L Galvanised Iron Wire 4.0mm dia (8 SWG) as Continuous Earth Wire, Guards and Cradles (hexagonal/rectangular), etc. and binding with and including GI Binding Wire 1.6mm dia, complete all as specified and as directed.
M&L Stay Assembly complete with all Accessories including earth work such as Mild Steel Galvanised Flat Iron Stay Clamp, Galvanised Stay Wire 7/4.0mm stranded, One Insulator Loop type Porcelain Vitreous (white, brown or green) Overall Dimensions 90x140mm and Clearance of Hole 25.5mm, Stay Grips, Mild Steel Galvanised Stay Bow, Thimbles Galvanised steel 14mm dia & 400mm long, 20mm dia Mild Steel Galvanised Stay Rod 1900mm long and Mild Steel Galvanised Stay Plate of size 300x300x6.0mm all as shown in Electrical Plate No. 1 of MES Schedule Part-I, complete all as specified and as directed.
S&F Danger Notice Plate of Size 25x20 Cm for LT, made of 1.6 mm thick Mild Steel Sheet, Vitreous Enamelled White, Letters, Figures and Conventional Skull & Bones in Signal Red Colour and fixed with Mild Steel Vlamps, Bolts & Nuts of appoved size including Taking down Unserviceable Danger Notice Plate, complete all as specified and as directed.
M&L Trimming/Cutting of Tree Branches of any girth/size and Clearing of LT OH Lines (any Nos. of ACSR Conductors, Earth Wire, etc.) upto 3.0 Metre distance, Removing Tree Branches from the Sites, complete all as specified and as directed.
M&L Painting LT Pre-stressed Concrete Pole including Cross Arms, Channel, Flat Iron Clamps, etc. with Two coats of Cement Based Paints and Numbering of Code in letter size not less then 50mm in Black Paints and Painting of Pole with Strips 300mm high (5 Nos.) around the Pole with Two different Colour Synthetic Enamelled Paint for Pole 7.5 Metre height above Ground Level, complete all as specified and as directed.
M&L Painting LT Steel Tubular Pole including Cross Arms, Channel, Flat Iron Clamps, etc. with One coat of Aluminium Paints and Numbering of Code in letter size not less then 50mm in Black Paints and Painting of Pole with Strips 300mm high (5 Nos.) around the Pole with Two different Colour Synthetic Enamelled Paint for Pole 7.5 Metre height above Ground Level, complete all as specified and as directed.
REPAIRS & MAINT TO LT UG CABLE WORKS
Disconnecting & Taking down/out unserviceable LT Cable of any size and any description including GI Pipes, Bricks, etc. from Trenches, Floors, Poles, Walls, complete all as specified and as directed. NOTE : Necessary Earthworks will be Measured & Paid under appropriate Items.
M&L XLPE insulated, Armoured, Heavy duty, Electric Cable with Aluminium Stranded Conductor, 1100 Volt grade, Cross-sectional Area 10 Sqmm, 2 Core, laid in Trenches/ Ducts or Passing through Pipe or Fixing on Poles, etc., complete all as specified and as directed. NOTE : Necessary Earthworks, Sand Cushioning, Bricks Protection, GI Pipe, etc. will be Measured and Paid separately under relevent Items.
M&L XLPE insulated, Armoured, Heavy duty, Electric Cable with Aluminium Stranded Conductor, 1100 Volt grade, Cross-sectional Area 16 Sqmm, 3½ Core, laid in Trenches/ Ducts or Passing through Pipe or Fixing on Poles, etc., complete all as specified and as directed. NOTE : Necessary Earthworks, Sand Cushioning, Bricks Protection, GI Pipe, etc. will be Measured and Paid separately under relevent Items.
M&L XLPE insulated, Armoured, Heavy duty, Electric Cable with Aluminium Stranded Conductor, 1100 Volt grade, Cross-sectional Area 35 Sqmm, 3½ Core, laid in Trenches/ Ducts or Passing through Pipe or Fixing on Poles, etc., complete all as specified and as directed. NOTE : Necessary Earthworks, Sand Cushioning, Bricks Protection, GI Pipe, etc. will be Measured and Paid separately under relevent Items.
M&L XLPE insulated, Armoured, Heavy duty, Electric Cable with Aluminium Stranded Conductor, 1100 Volt grade, Cross-sectional Area 50 Sqmm, 3½ Core, laid in Trenches/ Ducts or Passing through Pipe or Fixing on Poles, etc., complete all as specified and as directed. NOTE : Necessary Earthworks, Sand Cushioning, Bricks Protection, GI Pipe, etc. will be Measured and Paid separately under relevent Items.
M&L XLPE insulated, Armoured, Heavy duty, Electric Cable with Aluminium Stranded Conductor, 1100 Volt grade, Cross-sectional Area 70 Sqmm, 3½ Core, laid in Trenches/ Ducts or Passing through Pipe or Fixing on Poles, etc., complete all as specified and as directed. NOTE : Necessary Earthworks, Sand Cushioning, Bricks Protection, GI Pipe, etc. will be Measured and Paid separately under relevent Items.
M&L XLPE insulated, Armoured, Heavy duty, Electric Cable with Aluminium Stranded Conductor, 1100 Volt grade, Cross-sectional Area 95 Sqmm, 3½ Core, laid in Trenches/ Ducts or Passing through Pipe or Fixing on Poles, etc., complete all as specified and as directed. NOTE : Necessary Earthworks, Sand Cushioning, Bricks Protection, GI Pipe, etc. will be Measured and Paid separately under relevent Items.
M&L XLPE insulated, Armoured, Heavy duty, Electric Cable with Aluminium Stranded Conductor, 1100 Volt grade, Cross-sectional Area 120 Sqmm, 3½ Core, laid in Trenches/ Ducts or Passing through Pipe or Fixing on Poles, etc., complete all as specified and as directed. NOTE : Necessary Earthworks, Sand Cushioning, Bricks Protection, GI Pipe, etc. will be Measured and Paid separately under relevent Items.
M&L XLPE insulated, Armoured, Heavy duty, Electric Cable with Aluminium Stranded Conductor, 1100 Volt grade, Cross-sectional Area 150 Sqmm, 3½ Core, laid in Trenches/ Ducts or Passing through Pipe or Fixing on Poles, etc., complete all as specified and as directed. NOTE : Necessary Earthworks, Sand Cushioning, Bricks Protection, GI Pipe, etc. will be Measured and Paid separately under relevent Items.
M&L XLPE insulated, Armoured, Heavy duty, Electric Cable with Aluminium Stranded Conductor, 1100 Volt grade, Cross-sectional Area 185 Sqmm, 3½ Core, laid in Trenches/ Ducts or Passing through Pipe or Fixing on Poles, etc., complete all as specified and as directed. NOTE : Necessary Earthworks, Sand Cushioning, Bricks Protection, GI Pipe, etc. will be Measured and Paid separately under relevent Items.
M&L Taking down unserviceable LT Cable of any description (Size, Core, etc.), 1100 Volt grade from any Situation, finding out Cable Fault and Rectification of Cable Fault as Ordered, Relaying/ Re-fixing the Cable after Rectification, complete all as specified and as directed. NOTE : Necessary Earthworks, Sand Cushioning, Bricks Protection, GI Pipe, etc. will be Measured and Paid separately under relevent Items.
M&L Cable Jointing Kit, Straight Through, Heat Shrink type complete with Jointing Materials and Accessories suitable for 1100 Volt Grade XLPE Armoured Aluminium Conductor Cable, Cross-sectional Area 25 Sqmm to 50 Sqmm, 3½/4.0 Core and Testing, complete all as specified and as directed.
M&L Cable Jointing Kit, Straight Through, Heat Shrink type complete with Jointing Materials and Accessories suitable for 1100 Volt Grade XLPE Armoured Aluminium Conductor Cable, Cross-sectional Area 70 Sqmm to 95 Sqmm, 3½/4.0 Core and Testing, complete all as specified and as directed.
M&L Cable Jointing Kit, Straight Through, Heat Shrink type complete with Jointing Materials and Accessories suitable for 1100 Volt Grade XLPE Armoured Aluminium Conductor Cable, Cross-sectional Area 120 Sqmm to 185 Sqmm, 3½/4.0 Core and Testing, complete all as specified and as directed.
M&L Sand Cushioning (Dry) in Trenches/Ducts for protection of UG Cables (below, above and around the UG Cable laid) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180mm thickness, complete all as specified and as directed. NOTE : For the purpose of Payment, Punned thickness of Sand Cushioning only will be Measured.
Supply & laying Sub-class ‘B’ Bricks of Size 230x115x75 mm, Kiln burnt, for Covering to UG Cable as Protection, laid Flat, Transversally Width Equal to the Length of the Cable, complete all as specified and as directed.
M&L Galvanised Steel Tubing Pipe 40mm bore (dia), 'Light grade' with Bend, laid in Trenches or Under Roads/ Flooring/ Culverts and/or fixing to Electric Poles with suitable Size Mild Steel Flat Iron Clamps, Bolts, Nuts, Washers, etc., complete all as specified and as directed.
M&L Galvanised Steel Tubing Pipe 50mm bore (dia), 'Light grade' with Bend, laid in Trenches or Under Roads/ Flooring/ Culverts and/or fixing to Electric Poles with suitable Size Mild Steel Flat Iron Clamps, Bolts, Nuts, Washers, etc., complete all as specified and as directed.
M&L Galvanised Steel Tubing Pipe 80mm bore (dia), 'Light grade' with Bend, laid in Trenches or Under Roads/ Flooring/ Culverts and/or fixing to Electric Poles with suitable Size Mild Steel Flat Iron Clamps, Bolts, Nuts, Washers, etc., complete all as specified and as directed.
M&L UG Cable Route Indicator, comprising of Mild Steel Round Bar 20mm dia as Leg 600mm long and welded to Mild Steel Plate 5.0mm thick of 100mm dia for Writing 1.1 KV LT UG CABLE with Arrow mark, fixing with and including Cement Concrete 1:2:4 (20mm graded Stone aggregate) Block of Size 300x300x 400mm, grouting in Natural Ground along the Cable Route including necessary Earth Works (as per Site requirment), complete all as specified and as directed. NOTE : Cost of necessary Earthworks will deem to be included in the Quoted Unit Rate.
REPAIRS & MAINT TO LT PANEL BOARDS AND EARTHING
S&F Air Circuit Breaker 630 Amp, 4 Pole, 415 Volt, 50 Hz, Front Operated with Thermal Magnetic Realease (Manual Drawout type) and fixing to existing Panel Board including Taking down/ out Unserviceable ACB of any description, complete all as specified and as directed.
S&F MCCB 63 Amp 3 Pole, 16 kA, 415 Volt, 50 Hz including Outgoing and Incoming Cable Connection and fixing to existing Panel Board including Taking down/ out Unserviceable MCCB, complete all as specified and as directed.
S&F MCCB 100 Amp 3 Pole, 16 kA, 415 Volt, 50 Hz including Outgoing and Incoming Cable Connection and fixing to existing Panel Board including Taking down/ out Unserviceable MCCB, complete all as specified and as directed.
S&F MCCB 100 Amp 3 Pole, 16 kA, 415 Volt, 50 Hz Volt, Adjustable Thermal (80%-100%), (Ics=100%) and fixing to existing Panel Board including Taking down/ out Unserviceable MCCB, complete all as specified and as directed.
S&F MCCB 125 Amp 3 Pole, 16 kA, 415 Volt, 50 Hz including Outgoing and Incoming Cable Connection and fixing to existing Panel Board including Taking down/ out Unserviceable MCCB, complete all as specified and as directed.
S&F MCCB 250 Amp 4 Pole, 36 kA, 415 Volt, 50 Hz including Outgoing and Incoming Cable Connection and fixing to existing Panel Board including Taking down/ out Unserviceable MCCB, complete all as specified and as directed.
S&F MCCB 250 Amp 4 Pole, 36 kA, 415 Volt, 50 Hz Volt, Adjustable Thermal (80%-100%), (Ics=100%) and fixing to existing Panel Board including Taking down/ out Unserviceable MCCB, complete all as specified and as directed.
S&F MCCB 400 Amp 4 Pole, 36 kA, 415 Volt, 50 Hz including Outgoing and Incoming Cable Connection and fixing to existing Panel Board including Taking down/ out Unserviceable MCCB, complete all as specified and as directed.
S&F MCCB 400 Amp 4 Pole, 36 kA, 415 Volt, 50 Hz Volt, Adjustable Thermal (80%-100%), (Ics=100%) and fixing to existing Panel Board including Taking down/ out Unserviceable MCCB, complete all as specified and as directed.
S&F On Load Change Over Switch 63 Amp rating, 4 Pole, 415 Volt (Side Handle Operated) in Sheet Metal Enclouser and Connecting up including Taking down/ out Unserviceable Change Over Switch, complete all as specified and as directed.
S&F On Load Change Over Switch 100 Amp rating, 4 Pole, 415 Volt (Side Handle Operated) in Sheet Metal Enclouser and Connecting up including Taking down/ out Unserviceable Change Over Switch, complete all as specified and as directed.
S&F On Load Change Over Switch (Front Operated), Open Execution 100 Amp rating, 4 Pole, 415 Volt and Connecting up including Taking down/ out Unserviceable Change Over Switch, complete all as specified and as directed.
S&F On Load Change Over Switch (Front Operated), Open Execution 160 Amp rating, 4 Pole, 415 Volt and Connecting up including Taking down/ out Unserviceable Change Over Switch, complete all as specified and as directed.
S&F On Load Change Over Switch 200 Amp rating, 4 Pole, 415 Volt (Side Handle Operated) in Sheet Metal Enclouser and Connecting up including Taking down/ out Unserviceable Change Over Switch, complete all as specified and as directed.
S&F On Load Change Over Switch 320 Amp rating, 4 Pole, 415 Volt (Side Handle Operated) in Sheet Metal Enclouser and Connecting up including Taking down/ out Unserviceable Change Over Switch, complete all as specified and as directed.
M&L Repairing broken Door, Locking Arrangements, Hinges, etc. of LT Panel/ Feeder Pillar/ Pole Box, Indoor/ Outdoor type of any size, necessary welding, drilling as reqiured, Replacing Door, Locking Arrangements, Hinges, etc., complete all as specified and as directed.
M&L Cleaning, Scraping of Exposed Surfaces of LT Panel/ Feeder Pillar /Pole Box, Indoor/ Outdoor Type and applying One coat of Synthetic Enamel Paint (Paint & Shade as approved) with Spray Painting Machine including Writing MES No. and Machine No. with Black Paint, Letters 50mm High and 15mm Wide, complete all as specified and as directed.
S&F Synthetic Insulation Mat of Size 2000x1000x12mm thick (as approved), ISI marked and suitable for 1100 Volts Grade including Taking out Unserviceable Insulation Mat of any description, complete all as specified and as directed.
M&L Earthing with Galvanised Earth Plate Electrode 600x600x6.0mm thick, buried directly in Ground vertically to a depth not less than 2.25 Metre below Ground Level with Top Edge of Earth Plate at depth not less than 1.50 Metre below normal Ground Level, connected to Galvanised Earth Lead Wire 4.0mm dia by means of Bolts, Nuts, Check, Nuts and Washers of Galvanised Iron or Steel and Earth Wire protected with and including GI Pipe 15mm bore (dia) Light grade, connected to Test Point upto 7.50 Metre away from Earth Electrode situated, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc.150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, PGI Funnel with GI Watering Pipe 20mm bore (dia) Medium grade including necessary Earth Works in Soft/ Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including Taking down/out Unserviceable Earthing of any description, complete all as per specified and as directed.
M&L Earthing with Galvanised Earth Plate Electrode 600x600x6.0mm thick burried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with and including Galvanised Earth Strip of size 32x6.0mm by means of Bolts, Nuts, Check nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar with GI 40mm bore (dia) Light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc. 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, PGI Funnel with GI Watering Pipe 20mm bore (dia) Medium grade including necessary Excavation in Soft/Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including Taking down/out Unserviceable Earthing of any description, complete all as per specified and as directed. NOTE : All Joints should be joined by Exothermic Welding or Brazing.
M&L Earthing with Copper Earth Plate Electrode 600x600x3.15mm thick burried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with and including Copper Earth Strip of size 20x3.0mm by means of Bolts, Nuts, Check nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar with GI 40mm bore (dia) Light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc. 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, PGI Funnel with GI Watering Pipe 20mm bore (dia) Medium grade including necessary Excavation in Soft/Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including Taking Taking down/out Unserviceable Earthing of any description, complete all as per specified and as directed. NOTE : All Joints should be joined by Exothermic Welding or Brazing.
M&L Chemical Earthing with Copper Earth Plate Electrode 900x900x5.0mm thick, Maintenance Free UL Approved Copper Bonded Earth Rod of 10 Feet length 17.2mm dia made of High Tensile Low Carbon Steel Rod, molecularly bonded with 99.9% Electrolyte grade Copper on Outer Surface (minimum Copper bonding thickness-250 microns) jointed with Copper Strip 50x6.0mm through Stainless Steel Clamps Joint/Exothermic jointed with Bus-bar of 50x6x200mm with minimum 50 KG Eco Friendly Earth Enhancing Compound with Each Earth Rod, GI Protection Pipe 40mm bore (dia) of Light grade, Copper Strip 50x6.0mm upto Test Point. The Earth Pit 125mm dia with FRP Earth Pit Cover of Top Size 200x200mm and Bottom Size 300x300mm with Height of 150mm with Lockable Lid including All necessary Earth Works and all as shown in MES Schedule Part-I and Testing on Completion including Taking Taking down/out Unserviceable Earthing of any description, complete all as per specified and as directed. MAKE : OBO BETTERMAN/ ERICO/ FURSE/ INGESCO/ JMV LPS/ Make approved by E-in-C's Br./having sufficient Experience in this Field. NOTE : All Joints should be joined by Exothermic Welding or Brazing.
REPAIRS & MAINT TO DG SETS
M&L Repairs/Maint & Servicing of DG Set 25 KVA & 30 KVA Capacity of MAKE : KIRLOSKAR, complete all as specified and as directed comprising with the following Works:- (a) Replacement of all Filters, Lubricating Oil. (b) Checking of Belt Tension, Battery Connections and Topping up Distilled Water (if required), External Bolts and Nuts and its Tightening, Safety Units and its Electrical Connection, Alternator Cable Connections, Engine Control Wirings. (c) Carry out necessary Tappet Clearance, if required. (d) Cleaning of Fuel Lines, Inlet Air Lines and Exhaust Liner Radiator Fins. (e) Check functioning of Changing Alternator. (f) Engine Safety viz. High Water Temperature Gauge, Oil Pressure Gauge, Oil Temperature Gauge and High Speed Gauge shall be checked for their functions and repaired/replaced if required. (g) Coolant Level and Conditioning of Coolant shall be checked and refilled if required. (h) The Governor shall be Checked and Tuned for Proper Functioning. (j) Check for Leaks if any and shall be rectified. (k) The Engine shall be Run on NO LOAD or at AVAILABLE LOAD, Check any Leakage and Abnormal Noise. If any such abnormality Noticed the same shall be Diagnosed and Remedial Action shall be taken to removed the casues. NOTE :- (a) Cost of all Materials i.e. Spare Parts and Labour Elements required for Functional of DG Set will deem to be included in the Quoted Unit Rate. (b) Quantites of Spare Parts at Item No. 7.02 to 7.11 are Proisional and will be Measured & Paid as 'Supply only' under appropriate Items.
Supply only Air Filter Assembly (as per existing/ as approved) suitable for DG Set 25 KVA & 30 KVA Capacity of MAKE : KIRLOSKAR, complete all as specified and as directed.
Supply only AVR (as per existing/ as approved) suitable for DG Set 25 KVA & 30 KVA Capacity of MAKE : KIRLOSKAR, complete all as specified and as directed.
Supply only Bearing for Cooling Fan and Fan Belt (as per existing/ as approved) suitable for DG Set 25 KVA & 30 KVA Capacity of MAKE : KIRLOSKAR, complete all as specified and as directed.
Supply only Controler Model No. KG934 (as per existing/ as approved) suitable for DG Set 25 KVA & 30 KVA Capacity of MAKE : KIRLOSKAR, complete all as specified and as directed.
Supply only Cooling Fan (as per existing/ as approved) suitable for DG Set 25 KVA & 30 KVA Capacity of MAKE : KIRLOSKAR, complete all as specified and as directed.
Supply only Door Hinges with Nut & Bolts (as per existing/ as approved) suitable for DG Set 25 KVA & 30 KVA Capacity of MAKE : KIRLOSKAR, complete all as specified and as directed.
Supply only Fuel Pipe (as per existing/ as approved) suitable for DG Set 25 KVA & 30 KVA Capacity of MAKE : KIRLOSKAR, complete all as specified and as directed.
Supply only Fuel Filer Assembly (as per existing/ as approved) suitable for DG Set 25 KVA & 30 KVA Capacity of MAKE : KIRLOSKAR, complete all as specified and as directed.
Supply only Oil Filer Assembly (as per existing/ as approved) suitable for DG Set 25 KVA & 30 KVA Capacity of MAKE : KIRLOSKAR, complete all as specified and as directed.
Supply only 'V' Belt (as per existing/ as approved) suitable for DG Set 25 KVA & 30 KVA Capacity of MAKE : KIRLOSKAR, complete all as specified and as directed.
M&L Repairs/Maint & Servicing of DG Set 62.5 KVA Capacity of MAKE : ASHOK LEYLAND/ KIRLOSKAR, complete all as specified and as directed comprising with the following Works:- (a) Replacement of all Filters, Lubricating Oil. (b) Checking of Belt Tension, Battery Connections and Topping up Distilled Water (if required), External Bolts and Nuts and its Tightening, Safety Units and its Electrical Connection, Alternator Cable Connections, Engine Control Wirings. (c) Carry out necessary Tappet Clearance, if required. (d) Cleaning of Fuel Lines, Inlet Air Lines and Exhaust Liner Radiator Fins. (e) Check functioning of Changing Alternator. (f) Engine Safety viz. High Water Temperature Gauge, Oil Pressure Gauge, Oil Temperature Gauge and High Speed Gauge shall be checked for their functions and repaired/replaced if required. (g) Coolant Level and Conditioning of Coolant shall be checked and refilled if required. (h) The Governor shall be Checked and Tuned for Proper Functioning. (j) Check for Leaks if any and shall be rectified. (k) The Engine shall be Run on NO LOAD or at AVAILABLE LOAD, Check any Leakage and Abnormal Noise. If any such abnormality Noticed the same shall be Diagnosed and Remedial Action shall be taken to removed the casues. NOTE :- (a) Cost of all Materials i.e. Spare Parts and Labour Elements required for Functional of DG Set will deem to be included in the Quoted Unit Rate. (b) Quantites of Spare Parts at Item No. 7.13 to 7.22 are Proisional and will be Measured & Paid as 'Supply only' under appropriate Items.
Supply only Air Filter Assembly (as per existing/ as approved) suitable for DG Set 62.5 KVA Capacity of MAKE : ASHOK LEYLAND/ KIRLOSKAR, complete all as specified and as directed.
Supply only AVR (as per existing/ as approved) suitable for DG Set 62.5 KVA Capacity of MAKE : ASHOK LEYLAND/ KIRLOSKAR, complete all as specified and as directed.
Supply only Bearing for 62.5 KVA Capacity of MAKE : ASHOK LEYLAND/ KIRLOSKAR, complete all as specified and as directed.
Supply only Controler Model No. KG934 (as per existing/ as approved) suitable for DG Set 62.5 KVA Capacity of MAKE : ASHOK LEYLAND/ KIRLOSKAR, complete all as specified and as directed.
Supply only Cooling Fan (as per existing/ as approved) suitable for DG Set 62.5 KVA Capacity of MAKE : ASHOK LEYLAND/ KIRLOSKAR, complete all as specified and as directed.
Supply only Door Hinges with Nut & Bolts (as per existing/ as approved) suitable for DG Set 62.5 KVA Capacity of MAKE : ASHOK LEYLAND/ KIRLOSKAR, complete all as specified and as directed.
Supply only Fuel Pipe (as per existing/ as approved) suitable for DG Set 62.5 KVA Capacity of MAKE : ASHOK LEYLAND/ KIRLOSKAR, complete all as specified and as directed.
Supply only Fuel Filer Assembly (as per existing/ as approved) suitable for DG Set 62.5 KVA Capacity of MAKE : ASHOK LEYLAND/ KIRLOSKAR, complete all as specified and as directed.
Supply only Oil Filer Assembly (as per existing/ as approved) suitable for DG Set 62.5 KVA Capacity of MAKE : ASHOK LEYLAND/ KIRLOSKAR, complete all as specified and as directed.
Supply only 'V' Belt (as per existing/ as approved) suitable for DG Set 62.5 KVA Capacity of MAKE : ASHOK LEYLAND/ KIRLOSKAR, complete all as specified and as directed.
M&L Repairs/Maint & Servicing of DG Set 125 KVA Capacity of MAKE : ASHOK LEYLAND/ KIRLOSKAR/ KIRLOSKAR GREEN, complete all as specified and as directed comprising with the following Works:- (a) Replacement of all Filters, Lubricating Oil. (b) Checking of Belt Tension, Battery Connections and Topping up Distilled Water (if required), External Bolts and Nuts and its Tightening, Safety Units and its Electrical Connection, Alternator Cable Connections, Engine Control Wirings. (c) Carry out necessary Tappet Clearance, if required. (d) Cleaning of Fuel Lines, Inlet Air Lines and Exhaust Liner Radiator Fins. (e) Check functioning of Changing Alternator. (f) Engine Safety viz. High Water Temperature Gauge, Oil Pressure Gauge, Oil Temperature Gauge and High Speed Gauge shall be checked for their functions and repaired/replaced if required. (g) Coolant Level and Conditioning of Coolant shall be checked and refilled if required. (h) The Governor shall be Checked and Tuned for Proper Functioning. (j) Check for Leaks if any and shall be rectified. (k) The Engine shall be Run on NO LOAD or at AVAILABLE LOAD, Check any Leakage and Abnormal Noise. If any such abnormality Noticed the same shall be Diagnosed and Remedial Action shall be taken to removed the casues. NOTE :- (a) Cost of all Materials i.e. Spare Parts and Labour Elements required for Functional of DG Set will deem to be included in the Quoted Unit Rate. (b) Quantites of Spare Parts at Item No. 7.24 to 7.33 are Proisional and will be Measured & Paid as 'Supply only' under appropriate Items.
Supply only Air Filter Assembly (as per existing/ as approved) suitable for DG Set 125 KVA Capacity of MAKE : ASHOK LEYLAND/ KIRLOSKAR/ KIRLOSKAR GREEN, complete all as specified and as directed.
Supply only AVR (as per existing/ as approved) suitable for DG Set 125 KVA Capacity of MAKE : ASHOK LEYLAND/ KIRLOSKAR/ KIRLOSKAR GREEN, complete all as specified and as directed.
Supply only Bearing for 125 KVA Capacity of MAKE : ASHOK LEYLAND/ KIRLOSKAR/ KIRLOSKAR GREEN, complete all as specified and as directed.
Supply only Controler Model No. KG934 (as per existing/ as approved) suitable for DG Set 125 KVA Capacity of MAKE : ASHOK LEYLAND/ KIRLOSKAR/ KIRLOSKAR GREEN, complete all as specified and as directed.
Supply only Cooling Fan (as per existing/ as approved) suitable for DG Set 125 KVA Capacity of MAKE : ASHOK LEYLAND/ KIRLOSKAR/ KIRLOSKAR GREEN, complete all as specified and as directed.
Supply only Door Hinges with Nut & Bolts (as per existing/ as approved) suitable for DG Set 125 KVA Capacity of MAKE : ASHOK LEYLAND/ KIRLOSKAR/ KIRLOSKAR GREEN, complete all as specified and as directed.
Supply only Fuel Pipe (as per existing/ as approved) suitable for DG Set 125 KVA Capacity of MAKE : ASHOK LEYLAND/ KIRLOSKAR/ KIRLOSKAR GREEN, complete all as specified and as directed.
Supply only Fuel Filer Assembly (as per existing/ as approved) suitable for DG Set 125 KVA Capacity of MAKE : ASHOK LEYLAND/ KIRLOSKAR/ KIRLOSKAR GREEN, complete all as specified and as directed.
Supply only Oil Filer Assembly (as per existing/ as approved) suitable for DG Set 125 KVA Capacity of MAKE : ASHOK LEYLAND/ KIRLOSKAR/ KIRLOSKAR GREEN, complete all as specified and as directed.
Supply only 'V' Belt (as per existing/ as approved) suitable for DG Set 125 KVA Capacity of MAKE : ASHOK LEYLAND/ KIRLOSKAR/ KIRLOSKAR GREEN, complete all as specified and as directed.
M&L Repairs/Maint & Servicing of DG Set 160 KVA Capacity of MAKE : KIRLOSKAR, complete all as specified and as directed comprising with the following Works:- (a) Replacement of all Filters, Lubricating Oil. (b) Checking of Belt Tension, Battery Connections and Topping up Distilled Water (if required), External Bolts and Nuts and its Tightening, Safety Units and its Electrical Connection, Alternator Cable Connections, Engine Control Wirings. (c) Carry out necessary Tappet Clearance, if required. (d) Cleaning of Fuel Lines, Inlet Air Lines and Exhaust Liner Radiator Fins. (e) Check functioning of Changing Alternator. (f) Engine Safety viz. High Water Temperature Gauge, Oil Pressure Gauge, Oil Temperature Gauge and High Speed Gauge shall be checked for their functions and repaired/replaced if required. (g) Coolant Level and Conditioning of Coolant shall be checked and refilled if required. (h) The Governor shall be Checked and Tuned for Proper Functioning. (j) Check for Leaks if any and shall be rectified. (k) The Engine shall be Run on NO LOAD or at AVAILABLE LOAD, Check any Leakage and Abnormal Noise. If any such abnormality Noticed the same shall be Diagnosed and Remedial Action shall be taken to removed the casues. NOTE :- (a) Cost of all Materials i.e. Spare Parts and Labour Elements required for Functional of DG Set will deem to be included in the Quoted Unit Rate. (b) Quantites of Spare Parts at Item No. 7.02 to 7.11 are Proisional and will be Measured & Paid as 'Supply only' under appropriate Items.
Supply only Air Filter Assembly (as per existing/ as approved) suitable for DG Set 160 KVA Capacity of MAKE : KIRLOSKAR, complete all as specified and as directed.
Supply only AVR (as per existing/ as approved) suitable for DG Set 160 KVA Capacity of MAKE : KIRLOSKAR, complete all as specified and as directed.
Supply only Bearing for Cooling Fan and Fan Belt (as per existing/ as approved) suitable for DG Set 160 KVA Capacity of MAKE : KIRLOSKAR, complete all as specified and as directed.
Supply only Controler Model No. KG934 (as per existing/ as approved) suitable for DG Set 160 KVA Capacity of MAKE : KIRLOSKAR, complete all as specified and as directed.
Supply only Cooling Fan (as per existing/ as approved) suitable for DG Set 160 KVA Capacity of MAKE : KIRLOSKAR, complete all as specified and as directed.
Supply only Door Hinges with Nut & Bolts (as per existing/ as approved) suitable for DG Set 160 KVA Capacity of MAKE : KIRLOSKAR, complete all as specified and as directed.
Supply only Fuel Pipe (as per existing/ as approved) suitable for DG Set 160 KVA Capacity of MAKE : KIRLOSKAR, complete all as specified and as directed.
Supply only Fuel Filer Assembly (as per existing/ as approved) suitable for DG Set 160 KVA Capacity of MAKE : KIRLOSKAR, complete all as specified and as directed.
Supply only Oil Filer Assembly (as per existing/ as approved) suitable for DG Set 160 KVA Capacity of MAKE : KIRLOSKAR, complete all as specified and as directed.
Supply only 'V' Belt (as per existing/ as approved) suitable for DG Set 160 KVA Capacity of MAKE : KIRLOSKAR, complete all as specified and as directed.
S&F Asbestos Rope (as approved) including Taking down/out Unserviceable Asbestos Rope, complete all as specified and as directed.
S&F Battery 12 Volt, 100 AH Capacity (as approved) and Providing all Electrical Connection including Taking down/out Unserviceable Battery, complete all as specified and as directed.
S&F Battery Copper Lead with Brass Clamps, Bolts & Nuts (as approved) for DG Set of any Capacity, Make, Type and connecting up including Taking down/ out Unserviceable Battery Lead, complete all as specified and as directed.
S&F Battery Terminal of Copper/Brass (as per existing/ as approved) and connecting up including Taking down/out Unserviceable Battery Terminal, complete all as specified and as directed.
S&F Digital Battery Charger of 100 to 150 AH Capacity suitable for Charging Battery 12 Volt and Providing All Electrical Connections as required for Battery Charging including Taking down Unserviceable Battery Charger after disconnect- ing all Electrical Connections and Removing Battery Charger to MES Store Yard at LIKABALI and deposited, complete all as specified and as directed.
S&F Fuel Pump Assembly, 1500 RPM, Supply Pressure of Fuel 4.5 PSI to 5.5 PSI, as per ISO : 4113 (as per existing/ as approved), suitable for DG Set 125 KVA Capacity of MAKE : ASHOK LEYLAND/ KIRLOSKAR/ KIRLOSKAR GREEN, and connecting up including Taking down/out Unserviceable Fuel Pump Assembly, complete all as specified and as directed. MAKE : STANDYNE or equivalent Make as approved by GE.
S&F Oil Safety Control (as per existing/ as approved) for DG Set of any Capacity, Make, Type and connecting up including Taking down/out Unserviceable Oil Safety Control, complete all as specified and as directed.
S&F Solenoid Switch Assembly (as per existing/ as approved) for DG Set of any Capacity, Make, Type and connecting up including Taking down/out Unservice-able Solenoid Switch Assembly, complete all as specified and as directed.
S&F Toggle Switch 3-Way, Double Pole (as per existing/ as approved) and connecting up including Taking down/out Unserviceable Toggle Switch, complete all as specified and as directed.
S&F Water Safety Control (as per existing/ as approved) for DG Set of any Capacity, Make, Type and connecting up including Taking down/out Unservice-able Water Safety Control, complete all as specified and as directed.
S&F Water Temperature Gauge (as per existing/ as approved) for DG Set of any Capacity, Make, Type and connecting up including Taking down/out Unservice-able Water Temperature Gauge, complete all as specified and as directed.
M&L Dismantling Alternator of DG Set 25 KVA to 62.5 KVA from its Position after Disconnecting All Electric Connections with the help of Chain Pully, Removing the Bearing with the help of Bearing Pullar and Shifting the Alternator to Authorised Workshop for Repair and Servicing complete, Checking of Connection, Terminals, Lugs Tightning of Connections, Replacement of Bushes complete and Refixing the same in Orignal Position and Proper Alignement, complete all as specified and as directed. NOTE : Rewinding of Alternator, Insulation Materials, Gasket, etc. will be Measured and Paid separately under relevent Items.
M&L Dismantling Alternator of DG Set 125 KVA to 160 KVA from its Position after Disconnecting All Electric Connections with the help of Chain Pully, Removing the Bearing with the help of Bearing Pullar and Shifting the Alternator to Authorised Workshop for Repair and Servicing complete, Checking of Connection, Terminals, Lugs Tightning of Connections, Replacement of Bushes complete and Refixing the same in Orignal Position and Proper Alignement, complete all as specified and as directed. NOTE : Rewinding of Alternator, Insulation Materials, Gasket, etc. will be Measured and Paid separately under relevent Items.
M&L Rewinding of Alternator Coils of any Capacity using Proper Size, Double Paper covering with Super Enamel Copper Winding Wires with Proper Guage, conforming to IS:7404 (Part-I) : 1991 (as per existing Size, Turns and Insulation Class including Providing All Insulation Materials, Gasket, etc., suitable for 415 Volt Alternator and Testing, complete all as specified and as directed.
Disconnecting & Dismounting of Self Starter 12 Volts from the Engine of DG Set 30 KVA to 62.5 KVA, Transporting to nearest Authorised Workshop for Repairing, Replacement of Unservicable Parts, Servicing Complete, Transporting the same from Workshop to Site of Work and Re-fixing with DG Set, Testing, complete all as specified and as directed.
Disconnecting & Dismounting of Self Starter 12 Volts from the Engine of DG Set 125 KVA to 160 KVA, Transporting to nearest Authorised Workshop for Repairing, Replacement of Unservicable Parts, Servicing Complete, Transporting the same from Workshop to Site of Work and Re-fixing with DG Set, Testing, complete all as specified and as directed.
M&L Repairing & Cleaning of Diesel Tank with suitable Materials after disconnecting Fuel Line, Opening of all Nuts, Bolts, etc., Re-fixing the same after satisfactory Repairing including necessary Welding (if required), etc., complete all as specified and as directed.
M&L Cleaning of Radiator of any Capacity after Opening all Nuts, Bolts, etc. by dismounting, Re-mounting after Cleaning with Chemical and Tightening of Nuts, Bolts, etc. including Straightening of Radiator Fins with suitable Tools, complete all as specified and as directed.
M&L Disconnecting all Electrical Cable Connection from the Dynamo Assembly and Taking down the Dynamo Assembly for Carry out Repairs and Complete Overhauling the System including Replacing the Unserviceable Parts like Carbon Bushes, Bearings, Armature, Burnt out coils, etc., Re-assambling & Re-fixing the Dynamo Assembly to Original Position and re-connecting all Electrical Cable Connections & Testing for DG Set 25 KVA to 62.5 KVA Capacity of Make : Ashok Leyland/ Kirloskar, complete all as specified and as directed.
M&L Disconnecting all Electrical Cable Connection from the Dynamo Assembly and Taking down the Dynamo Assembly for Carry out Repairs and Complete Overhauling the System including Replacing the Unserviceable Parts like Carbon Bushes, Bearings, Armature, Burnt out coils, etc., Re-assambling & Re-fixing the Dynamo Assembly to Original Position and re-connecting all Electrical Cable Connections & Testing for DG Set 62.5 KVA to 125 KVA Capacity of Make : Ashok Leyland/ Kirloskar, complete all as specified and as directed.
Supply & Filling Coolant for Radiators as approved), complete all as specified and as directed. MAKE : KIRLOSKAR or as approved by GE
Supply & Filling Engine Oil 20 W/ 40 Grade as approved), complete all as specified and as directed. MAKE : CASTROL CRB PLUS or as approved by GE
ms singh construction
M/s PRABIR ENTERPRISE
M/S P R SINGH AND SONS
Vicky Construction
M/s Singh enterprises
STANDARD ELECTRIC WINDERS
NChetia and Sons Trading
M/S R G Construction
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .