Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹3.0 LAdmitted-Finance SHOP NO Z2 10004 FIRST FLOOR MAIN 100 FEET ROAD NEAR GHORE WALA CHOWNK BATHINDA PUNJAB 151001 UDYAM PB 03 0033297 | BATHINDA | PUNJAB | 151001 | +0.00% | ₹3.0 L | L1 | Admitted-Finance |
| 2 | L2₹3.0 LAdmitted-Finance T G 4 4 TEGHARIA MAIN ROAD KOLKATA 700157 | 24 PARAGANAS NORTH | WEST BENGAL | 700157 | +1.35% | ₹3.0 L | L2 | Admitted-Finance |
| 3 | L3₹3.1 LAdmitted-Finance DONNAGAR GANGANAGAR KOLKATA 700132 | KOLKATA | NORTH 24 PARGANAS | WEST BENGAL | 700132 | +2.16% | ₹3.1 L | L3 | Admitted-Finance |
| Rank | Bidder | Quote | Total Amount |
|---|---|---|---|
| L2 | PIONEER ELECTRICALS Bid ID 7968411 | 1.35% above | ₹3,03,674.27 |
| L1 | PRINCE AND CO Bid ID 7968339 | At par | ₹2,99,629.27 |
| L3 | R S ENTERPRISE Bid ID 7968464 | 2.16% above | ₹3,06,101.26 |
Tender Value
₹3.0 L
EMD Value
₹6,000
Closing Date
26 Jan 2026, 4:00 pmClosed
EX.ENG(E)
SANTOSHPUR , KOL 75
IMPROVEMENT OF LIGHTING SYSTEM WITH LED FITTINGS AND POLE AT 2B, CHETLA ROAD WARD-81 IN KMC BR-X.
2026_KMC_990628_1
KMC/LTG/Z-IV/160/81/18/25-26
Open Tender
ELECTRICAL WORKS M/R
ward 81
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹6,000
13 Feb 2026
19 Jan 2026
26 Jan 2026
19 Jan 2026
26 Jan 2026
19 Jan 2026
Outdoor Lighting Installation, Steel Tubular Pole, M.S. Pipe, G.I. Pipe, Pole CAP etc Supplying of Swaged Steel Tubular pole as per IS 2713, Pt. II, 1980 for following designation and of following dimensions.(Outside dia & thickness are given in Annexture -1)e) 410 SP - 9 ; 7.5 Mtr., 110.00 Kg.
SCHEDULE OF RATES FOR OH LINE INSTALLATION (LT DISTRIBUTION).Erection of Poles.Erection of Single Steel tubular pole of length as given below with/without sole plate & Cap etc. in CC foundation (Proportion and dimension indicated below), having 600x600x150 mm thick CC (4:2:1) base block below sole plate/pole with hard jhama metal including CC (6:3:1) muffing 0.30 mts. dia and 0.30 mts. above ground level including 3 mm thick neat cemented finish and GI earth bolt after making drilled holes etc. on pole & carriage of pole upto 1.6 Km from Store to work(site including filling up the excavated earth pit with shifted soil and ramming properlyUpto 9.0 mtr. Size 0.6x0.6x1.70 mts
SCHEDULE OF RATES FOR EARTHING INSTALLATIONS.Earthing Installation ... with Pipe Electrode.Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (HOT Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:(a)By ISI Medium GI pipe.
SCHEDULE OF RATES FOR OVERHEAD LINE INSTALLATION - REPAIR 13. Providing CC (6:3:1) muffing 450x450x600 mm in size or equivalent size of cylindrical muffing above ground level around the pole base complete with 3 mm thick neatly finished cement plaster all round after dismantling the unserviceable muffing if any incl. fixing only loop box if necessary (a) Without Loop Box
S/F arm bracket of 50 mm bore tubular Pipe (M.S.) of 1. 5 m (5') length for fixing on 75/100 mm pole top including S/F 4 mm thick M.S. plate welded with bolts, nuts & clamps, etc. as required with fabrication work
S/F of special head type M S loop box (3 mm thick) with connecting bar and other accessories fixed on the top the pole as required and as per direction of Engineer-In-Charge. For 3 phase connection.
Supplying Al.conductor PVC insulated and sheathed unarmoredcable (1.1KVgrade, Gloster/Havells/Polycab). 10sqmm x 2core
Supplying Al.conductor PVC insulated and sheathed unarmoredcable (1.1KVgrade,Gloster/Havells/Polycab). 4sqmm x 2core
Supply and drawing of 7/14 SWG galvanised stranded wire for drawing unarmored cable (supply of cable is not included in the scope) by catenary system of wiring with 3nos. reel insulator per mtr. and binding with binding wires etc,as reqd. for drawing
SUPPLY & DELIVERY OF 200 WATT LED FITTINGS
Laying through RCC/Hume/GI Pipe.(a)Laying only Cable upto 50 sqmm through existing RCC/Hume/ GI Pipe/open masonary trench FOR single, 2, 3, 3... & 4 core
Painting steel tubular pole including projected arm bracket with one coat of red oxide primer and two coats with si lverlac AI. paint ete. (Scraping where necessary).Painting upto7 mtr Pole
Fixing only Floodlight fittings on top of masonary structure by 3 Nos. 10 mm dia x 87 mm long rag bolts, nuts & double washers complete either 37 mm x 10 mm MS flat support/or by other means as required
Sub Total
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.38 MB
BOQ_2421820.xls
BOQ • 0.27 MB
form.pdf
Tender Documents • 1.13 MB
Download all tender documents and submit your bid