Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAccepted-AOC | ₹1.1 Cr | L1 | Accepted-AOC Being L1 |
| 2 | L2₹1.2 Cr+₹14.3 L (13.1%)Rejected-Finance HOUSE NO 102 LANE NO 4 C ANAND NAGAR BOHRI JAMMU 180002 J K | JAMMU | JAMMU AND KASHMIR | 180002 | ₹1.2 Cr+₹14.3 L (13.1%) | L2 | Rejected-Finance Other than L1 |
| Sl No | Description | Qty | Unit | M/s Sunny Gupta L1 | SUMEET TRADING CORPORATION L2 |
|---|---|---|---|---|---|
| 1.00 | Preparing of floor including repair and cleaning of old concrete by way of washing, removing loose concrete, including levelling and curing the surface grinding or light vacuum contained shot blasting to expose the coarse aggregate, heavy oil or grease deposits should be removed by vacuum equipment complete all as specified and/ or as directed by Engr-in-Charge. | 2,984 | Sqm | 275 ₹8,20,600 | 110 ₹3,28,240 Lowest |
| 2.00 | Material and labour for cleaning the joints to remove all dust, dirt, oil & grease and the excessive laitance be removed by vacuum cleaning and filling dummy/ contraction/ expansion joint with Backer Rod so that the width to depth ratio of 1:1 to 1.5 :1 is achieved before applying sealant. Prime sealing slot surfaces with Primer No 20 using a clean dry brush. Sealant must be applied between 30 minutes and 02 hours after priming. Lay cold applied two component pitch free chemically cured PU Sealant Colpor 200PF at the designated joints over the Backer Rod. Colpor 200PF shall conform to BS 5212:1990 types N, F & FB with movement accomodation factor of 30% in butt joints and solid content of 96%. Colpor 200PF shall be resistant to fuel, oil and hydraulic fluid spillage. PU Sealant shall be allowed to cure for 12 - 16 hours at 35 Degree Celcius before accepting traffic. | 290 | 10 RM | 1,500 ₹4,35,000 | 550 ₹1,59,500 Lowest |
| 3.00 | Material and labour for Scratch coating with Fosroc Nitoflor SL3000 UT/ Tremco (Flowfresh, flowcrete)/ Sika or equivalent at a coverage rate of up to a nominal 1mm thickness; actual coverage rate will depend on concrete surface texture and porosity without any extra cost. This scratch coat is designed to prime and seal the floor, mixed and spread evenly by trowel. The scratch coat should be allowed to cure for 12-48 hours at 20 degree celcius before applying the top coat, complete all as specified and/or as directed by Engr-in-Charge. | 2,984 | Sqm | 985 ₹29,39,240 | 370 ₹11,04,080 Lowest |
| 4.00 | Providing and applying trowel applied heavy duty Cementitious polyurethane floor topping at 6 mm thickness using Fosroc Nitoflor RT 6000 UT a five-component product/ Tremco (flowcrete, Flowfresh - RT /Sika or equivalent). A forced-action rotary paddle mixer is recommended for mixing the product. Lightly textured finish makes the product ideal for both wet and dry processing environments giving slip resistance. Topping applied at 6mm thickness over scratch coat using a steel float while ensuring that enchorage grooves are fully wetted out with material. The cured product should be protected from other trades using Kraft paper or similar breathable material. The cured Polyurethane flooring shall exhibits the following minimum technical profiles and or as per relevant IS codes and standards of the make approved by GE :-
Fire Resistance-Class 1 BS 476
Coefficient of Thermal Expansion :- 3.74x10 @05 Degree Celcius BS EN 1770
Abrasion Resistance :- 0.12g loss per 1000 cycles (ASTM D4060 (1 KG load using CS17 wheels).
Compressive Strength 28D :- >50N/mm2 (BS 6319)
Abrasion Resistance :- 0.12g loss per 1000 cycles (ASTM D4060 (1 KG load using CS17 wheels). ASTMD4060
Impact Resistance :- 23Nm (ASTMD2794)
Water Absorption : 0.04% ASTMC413
Flexural Strength :- >13 N/mm2 (BS6319)
Vapour Permeability :- 3g/m2/24 hrs. at 6mm thick (ASTM E 96)
Tensile Strength :- >6 N/mm2 (BS 6319)
Flexural Modulus :- 3.2GPa (ASTM C580)
Bound Strength :- >2.5MPa (ASTMD4541)
Temperature Resistance : (Minus) -30 Deg C to Plus (+) 100 Deg C at 6mm thickness.
Anchorage grooves should be cut to a minimum of twice the thickness to be laid, upto a maximum of 10 mm and atleast equal in width to the thickness of material to be laid, at the edges, day joints, up-stands, drains, doorways and at regular points across the floor, and all debris removed work shall be executed by authorised Fosroc applicator and complete as per the instructions of manufacturer.
Note Srl No 01, 02 & 03 : Resurfacing works of flooring shall be carried out as per manufacturer's instructions and work shall be got executed through authorised applicator of the manufacturer's only. A certificate to this effect shall be obtained from the manufacturer about authorised applicator and got approved from GE. | 2,984 | Sqm | 2,250 ₹67,14,000 Lowest | 3,600 ₹1,07,42,400 |
Tender Value
₹1.0 Cr
EMD Value
₹1.8 L
Closing Date
27 Jul 2026, 6:00 pmClosed
CWE, HQ 138 WE
CWE, HQ 138 WE
SPECIAL REPAIR OF HANGER FLOOR OF BLDG NO T-32 AND T-33 AT ARMY AVN SQN UNDER GE 865 EWS
2026_MES_772528_1
138WE/L-24/2026-27
Open Tender
Civil Works
Item Rate
180 days
GE 865 EWS
As per Tender Documents
6 documents required · 6 mandatory
₹1,000
GE 865 EWS
₹1.8 L
Yes
12 Sept 2026
16 Jun 2026
3 Aug 2026
16 Jun 2026
27 Jul 2026
7 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Preparing of floor including repair and cleaning of old concrete by way of washing, removing loose concrete, including levelling and curing the surface grinding or light vacuum contained shot blasting to expose the coarse aggregate, heavy oil or grease deposits should be removed by vacuum equipment complete all as specified and/ or as directed by Engr-in-Charge. | 2,984 | Sqm | - | - |
| 2 | Material and labour for cleaning the joints to remove all dust, dirt, oil & grease and the excessive laitance be removed by vacuum cleaning and filling dummy/ contraction/ expansion joint with Backer Rod so that the width to depth ratio of 1:1 to 1.5 :1 is achieved before applying sealant. Prime sealing slot surfaces with Primer No 20 using a clean dry brush. Sealant must be applied between 30 minutes and 02 hours after priming. Lay cold applied two component pitch free chemically cured PU Sealant Colpor 200PF at the designated joints over the Backer Rod. Colpor 200PF shall conform to BS 5212:1990 types N, F & FB with movement accomodation factor of 30% in butt joints and solid content of 96%. Colpor 200PF shall be resistant to fuel, oil and hydraulic fluid spillage. PU Sealant shall be allowed to cure for 12 - 16 hours at 35 Degree Celcius before accepting traffic. | 290 | 10 RM | - | - |
| 3 | Material and labour for Scratch coating with Fosroc Nitoflor SL3000 UT/ Tremco (Flowfresh, flowcrete)/ Sika or equivalent at a coverage rate of up to a nominal 1mm thickness; actual coverage rate will depend on concrete surface texture and porosity without any extra cost. This scratch coat is designed to prime and seal the floor, mixed and spread evenly by trowel. The scratch coat should be allowed to cure for 12-48 hours at 20 degree celcius before applying the top coat, complete all as specified and/or as directed by Engr-in-Charge. | 2,984 | Sqm | - | - |
| 4 | Providing and applying trowel applied heavy duty Cementitious polyurethane floor topping at 6 mm thickness using Fosroc Nitoflor RT 6000 UT a five-component product/ Tremco (flowcrete, Flowfresh - RT /Sika or equivalent). A forced-action rotary paddle mixer is recommended for mixing the product. Lightly textured finish makes the product ideal for both wet and dry processing environments giving slip resistance. Topping applied at 6mm thickness over scratch coat using a steel float while ensuring that enchorage grooves are fully wetted out with material. The cured product should be protected from other trades using Kraft paper or similar breathable material. The cured Polyurethane flooring shall exhibits the following minimum technical profiles and or as per relevant IS codes and standards of the make approved by GE :-
Fire Resistance-Class 1 BS 476
Coefficient of Thermal Expansion :- 3.74x10 @05 Degree Celcius BS EN 1770
Abrasion Resistance :- 0.12g loss per 1000 cycles (ASTM D4060 (1 KG load using CS17 wheels).
Compressive Strength 28D :- >50N/mm2 (BS 6319)
Abrasion Resistance :- 0.12g loss per 1000 cycles (ASTM D4060 (1 KG load using CS17 wheels). ASTMD4060
Impact Resistance :- 23Nm (ASTMD2794)
Water Absorption : 0.04% ASTMC413
Flexural Strength :- >13 N/mm2 (BS6319)
Vapour Permeability :- 3g/m2/24 hrs. at 6mm thick (ASTM E 96)
Tensile Strength :- >6 N/mm2 (BS 6319)
Flexural Modulus :- 3.2GPa (ASTM C580)
Bound Strength :- >2.5MPa (ASTMD4541)
Temperature Resistance : (Minus) -30 Deg C to Plus (+) 100 Deg C at 6mm thickness.
Anchorage grooves should be cut to a minimum of twice the thickness to be laid, upto a maximum of 10 mm and atleast equal in width to the thickness of material to be laid, at the edges, day joints, up-stands, drains, doorways and at regular points across the floor, and all debris removed work shall be executed by authorised Fosroc applicator and complete as per the instructions of manufacturer.
Note Srl No 01, 02 & 03 : Resurfacing works of flooring shall be carried out as per manufacturer's instructions and work shall be got executed through authorised applicator of the manufacturer's only. A certificate to this effect shall be obtained from the manufacturer about authorised applicator and got approved from GE. | 2,984 | Sqm | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.33 MB
TenderL24202627.pdf
Tender Documents • 1.12 MB
BOQ_865042.xls
BOQ • 1.23 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .