Staff Oficer(EnM) Dhori Area
Officer of General Manager, Staff Oficer(EnM), Dhori Area, 825102
Complete Rewiring and Upgradation of different weighbridges under Dhori Area.
2025_CCL_338217_1
GM(D)/SO(EnM)/NIT/25-26/05
Open Tender
Electrical and Maintenance Works
Item Wise
25 days
Dhori Area
Please refer Tender documents.
2 documents required · 2 mandatory
₹26,000
Yes
15 Jul 2025
23 Jun 2025
5 Jul 2025
24 Jun 2025
4 Jul 2025
24 Jun 2025
24 Jun 2025 - 28 Jun 2025
Amount
Supply and Providing of SPD MA 15 :- SPD on 230/440 V AC side to protect the electronic weight indicator & computer .01 nos for each weigh bridge Rated voltage 230/440 volt Pole 3P+N Imax – 20kA
Supply and Providing of RCBO with AFDD for protection from electrical shock and fires 40 amps 1P+N
Isolation transformer Input voltage – 0 – 415-440VAC Shield 1 – Copper shield between primary and each secondary with ground terminal Output voltage – 0-230-250V-415VAC Output current – 3.5A VA Rating – 15KVA Shield 2 – Copper Shield after the outer layer of secondary connected to transformer mounting Winding material – Copper Core material – CRNO stampings Mounting – foot mount with L Clamp
Reviving of old earth-pits with necessary backfill compound changing of nuts and bolts and complete reviving of water arrangement for earth-pits .
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 25 mm X 5 mm Copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit along with 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (2X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire)
Providing and fixing following capacity TP&N dis-connector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. (63 Amps)
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (Group A)
Total impact of GST for the purpose of CTC
M/S KUMAR ENTERPRISES (BID ID -1165468)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .