Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.7 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹9.4 L+₹3,920 (0.42%)Rejected-AOC | L2 | Rejected-AOC Other than lowest bidder | |
| 3 | L3₹10.5 L+₹1.1 L (11.4%)Rejected-AOC | L3 | Rejected-AOC Other than lowest bidder |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
20 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Rajouri
HQ CWE Rajouri PIN-900129 C/o 56 APO
REPAIR / MAINTENANCE AND IMPROVEMENT OF HT INFRASTRUCTURE INCLUDING TRANSFORMER GOD SWITCHES WITH CONNECTED WORKS AT VARIOUS LOCATION UNDER AGE(I) CIF(R).
2021_MES_423273_1
CANO-CWE/PAL-67/2020-21
Open Tender
Support/Maintenance Service
Item Rate
180 days
AOR of AGE (I) CIF (R)
Class E Category b(ii)
9 documents required · 9 mandatory
₹500
AGE (I) CIF(R)
₹20,000
Yes
25 May 2021
18 Feb 2021
22 Mar 2021
18 Feb 2021
20 Mar 2021
4 Mar 2021
60 days
Amount
Steel tubular swaged poles erected to truly vertical or planted as strut complete with 6 mm thick mild steel base plate, welded to Pole, B-118 finial taper cap, bolts, nuts and screws, poles made out of ERW MS tubing conforming to IS-2713 Part-II type 410-SP-55 (11 m long) including drilling of holes of required size for fixing of cross arms, panting the exposed surfaces of pole with two coats of aluminum paint over a coat of red oxide zinc chrome primer and with two coats of black bituminous paint internally and portion embedded in concrete, making five black and white bands at lower portion of pole each 300mm wide alternately and marking pole number. with black paint at suitable height all as specified and directed.
Anti climbing devices, comprising 2.24mm dia galvanised steel 2-strand barbed wire with 2.00mm dia barbs wrapped spirally round poles, to a length of 0.5 to 1.0 metre clamped and properly secured or as ordered complete all as specified and directed. Note :- Clamps will be measured separately.
Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint all as specified & directed.
Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S Clamps, bolts and nuts of approved size for LT 20x15 cm size, complete all as specified and directed.
Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S Clamps, bolts and nuts of approved size for HT 25x20 cm size, complete all as specified and directed.
Stay assembly 20 mm dia of stay rod complete with all accessories as shown in electrical plate No 1 complete all as specified and directed. Note : Loop type insulator, stay clamps excavation and concrete work shall be measured separately.
Loop type insulator, vitreous porcelain, white, brown or green with overall dimensions 90x140mm, clearance of hole 25.5mm all as specified and directed.
Lightening arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 Kilo Amps, suitable for 11000 Volts, 10 KA, complete all as specified and directed.
Supply and install HT 11 KV outdoor gang operated air break switch suitable for horizontal or vertical mounting with drop out fuse having 12 insulators of rating upto 400 Amps incl taking down old unsv GOD all as specified and directed by Engr-in-charge. Note : All the connected tripping/fuse system shall be sleeved with coded colour as RYB.
Resin cast epoxy paint for GOD handle all as specified and directed by Engr -in -Charge
Earthing complet with galvanised steel earth plate eletrode 60cm x 60cm and 6 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level, connecting to the Galvanised iron earth lead 32mmx6mm size, by means of bolts, nuts, check buts and washers of galvanised iron and 32mmx6mm earth lead protected by provision of GI medium grade pipe 40mm bore including provision of aggregates with 40mm thick cover of RCC (1;2:4) reinfored with XPM (weight not less than 4 Kg/Sqm) and frame of angle iron 25mmx25mmx6mm with lugs 02 Nos and with 6mm dia MS bar handle made to shae, GI light grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, and fixed withexisting test point and fixing arrangment, funnel, wire mesh and earth work in hard/dense soil, returning filling in distance not exceeding 50 mtr and removal of surlus soil to plate No 3 of SSR-2009 Part-I and connecting to earth test point all as specified or indicated including testing on completion complete all as specified and directed.
GI pipe medium grade of dia 15 mm size for dropping system to all earthing with control valves & connecting up including bending, welding, cutting and fitting as required at site complete all as specified and directed.
GI pipe medium grade of dia 80 mm size for dropping system to all earthing with control valves & connecting up all as specified and directed.
Excvation in trenches n.exc 1.5 mtr wide and n.exc 1.5 m in depth for foundation and getting out in any type of soil, complete all as specified.
Description all as per item No-14 above but depth exceeding 1.5 m and not exceeding 3.00 m depth.
Removing of excavated soil not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all as specified and directed by Engineer-in-Charge.
Sand cushioning to underground cable, provided with a layer 8 cm thick before and 15 cm thick after laying and stretching and testing the cable all as specified and directed. Note: Punned thickness of sand shall be measured.
Sub class ‘B’ bricks old size, laid flat transversely along the length of cable with width equal to the length of bricks over sand cushioning as cable protection, laid in trenches, complete all as specified.
PCC (1:3:6) type D2 using 40 mm graded stone aggregate as in foundation filling and mass concrete including necessary use and waste of form work, complete all as specified.
Precast cement concrete block walling exc 10 cm width with solid block in nominal mix 1:3:6 type C-1 and setting in cement mortar (1:6), complete all as specified and directed.
PCC (1:4:8) Type D2 using 40 mm graded stone aggregate as in foundation filling and mass concrete including necessary use and waste of form work, complete all as specified and directed.
Rolled mild steel posts and struts in fencing including cutting tops to shape and split at bottom as directed, drilling holes for binding wires etc. incl providing flat iron fillets for securing wire mesh etc. incl all drilling, rivetting, bolting etc. and similar works. (Fe 410-w gde E-250 quality 'A'), complete all as specified and directed.
TMT bars 8mm dia & over, cut to length, bent to shape required including cranking, bending spirally or hooping for column, hooking ends and binding with and including mild steel wire(annealed) not less than 0.90mm dia, complete all as specified.
Chain link fencing 50 mm x 50 mm square mesh ( 3 mm dia of wire and min wt of 2.22Kg/sqm) with GI wire on MS angle posts incl binding wire complete all as specified and directed by the Engineer-in-Charge.
MS screw bolts (machine made 12 mm dia Shank) to MS angles with hexagonal or square heads at one end and screwed at another end, each screwed end to be fitted with washer and one hexagonal or square nut length of bolt not less than 75 mm, complete all as specified.
Preparation of steel surfaces of any description, over 10cm in width or girth, not otherwise described by treating with one coat of mordant solution to new galvanised steel surfaces and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed.
Factory made, machine pressed chequered cement conctrete tiles of size 20cmX20cmX25mm thick, set, jointed, and pointed in neat cement slurry in floors, complete all as directed by Engr-in-charge.
Cutting /Trimming/ Chopping of tree trenches along the overhead lines upto 3 m from electric lines clearance on both sides of overhead lines and disposing off the cut tree/ branches site to a distance not exc. 50 m and clearing the site as directed by Engr-in-Charge. (Note: The clar distance between two poles will be treated as one span).
Supply, laying & testing cable XLPE insulated, screened PVC bedded galvanised steel strip armoured HT electric power cable (heavy duty) 11000 volts grade with aluminum conductor 6.35 KV (UE)/11 KV (E) grade, cross sectional area 95 Sqmm, 3 core as per IS-7098 suitable for earth system laid in trenches complete all as specified and direcetd by the Engr-in-Charge. Note:- Earth work including excavation, returning filling in, removing, sand coushioning, brick covering for mechanical protection of cable etc will be measured and paid for separately under respective items of schedule.
Hard core of broken stone/boulders of gauge n exc 63mm deposited spreed and leveled in layers n exc 15cm thick watered and rammed to a true surface, complete all as specified.
XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 sqmm 4 core, complete all as specified.
XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 50 sqmm 3.5 core, complete all as specified.
Cable termination 11 KV HT (Heat shrinkable) cable jointing kit for 11 KV grade cable for end joint outdoor type heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sq mm, complete all as specified.
Cable termination 1.1 KV LT (Heat shrinkable) cable jointing kit for 1.1 KV grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size up to 95 sq mm, complete all as specified.
Taking down old unsv transformer at different locations in the area of responsibility falls under AGE(I) CIF (R) from two pole structure/ or plinth mounted by any means of mechanically operated pulley/ mechanical crane including disconnecting the LT/HT connection and transportation to MES store Yard / workshop and factory for repair/maint with & including transporting back of transformer to existing places to MES store yard or other existing substaions after repair & hoisting / lifting and placing in position and securing properly on pole mounted/plinth mounted including connecting all cable, earth lead, clamps and channels etc as per site requirement and testing after installation complete all as directed by Engineer-in-Charge of capacity transformer:- 25 to 100 KVA.
All as per items No 35 above but 100 to 200 KVA. Note for item No-35 & 36: (i) Please note that If any damage to transformer/OH line/cables occur during handling, transportation or during hoisting/lifting, the same will be rectified by the contractor without any extra cost to the department. (ii) Transportation to workshop and back to site /and required T&P like crane etc are to be arranged by contractor & rate for which is dimmed to be included in the item. (iii) If retrieved transformer oil's di-electric strength is very less, then it will be replaced with new one .as directed by Engineer Incharge and same will be measured & paid under relevent item. (ii) If any items like winding of HT coil, reconditioning of LT coil, spares like breather ,silica jel, bushes to be replaced for smooth functioning of transformer shall be measured in relevent items. (iii) Any minor item like nut ,bolt are included in this item rate.
Replacement of burnt defective HT/LT copper coile of different type capcity winding with superior qulity enamelled copper winding wire/strips of approved of suitable size/guage and Nos of turns maching with the existing impendence and insulated including all allied materials such as cork sheets, fiver glass insulation/paper insulation cotton, empire tape and wooden, bolts, nuts and washer (Brass) soldering and other packing material etc required for entire winding of coils all as specified and directed by Engineer- in-Charge.
Replacement of HT bushing porcelain, vitreous with brass spindle, threaded with washers nuts, lock nut and rubber seal suitable for transformer of any make /type/capacity in repairs all as specified and directed by Engineer-in-Charge.
Replacement of LT bushing porcelain, vitreous with brass spindle, threaded with washers nuts, lock nut and rubber seal suitable for transformer of any make /type/capacity in repairs all as specified and directed by Engineer-in-Charge.
Top gasket sheet made out of 2 mm thick cork sheet with suitable GI bolts, nuts, washers for top of transformer any capacity in repairs complete all as specified and directed.
Dehydrating breather assembly CI body of standard size filled with silica-gel for transformer of capacity upto and including upto and including 200 KVA in repairs complete all as specified and directed.
Temperature gauge circular dia type of standard size for transformer of capacity upto and including upto and including 250 KVA in repairs complete all as specified and directed
Material and labour for filling in with new transformer oil for top up having low viscosity of approved make as per IS 355 of 1992 and di-electric strength 40 KV(after filtration) complete all as specified and directed by Engineer-in-Charge. Make : Savita/Castrol
Supply and fixing in repairs Battery lead acid 12 volt DC, 150 Ah to be fitted on DG set including connecting S/C copper lead of size 10 Sqmm dia with two nos of bty terminal complete all as specified and directed.
Stay wire stranded 7/3.15 or 4mm including stay clamp and fixing arrangement complete all as specified
Kalsi Engineers and contractors
M/S PARSHOTAM KUMAR GUPTA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .