Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.6 LAccepted-AOC 93 4 16A BLOCK NO 3 JAWAHAR CHOWK PACHMARHI MP 461881 | PACHMARHI | HOSHANGABAD | MADHYA PRADESH | 461881 | L1 | Accepted-AOC L1 | |
| 2 | L2₹7.8 L+₹3,461.75 (0.44%)Rejected-Finance NEAR BUS STAND PACHMARHI MP PIN 461881 | PACHMARHI | HOSHANGABAD | MADHYA PRADESH | 461881 | L2 | Rejected-Finance Not Admitted | |
| 3 | L3₹8.7 L+₹87,435 (11.2%)Rejected-Finance SURVEY NO 93 392 PACHMARHI NEAR MILITARY HOSPITAL PAHMARHI HOSHANGABAD M P 461 881 | PACHMARHI | HOSHANGABAD | MADHYA PRADESH | 461881 | L3 | Rejected-Finance Not Admitted |
Tender Value
Refer Docs
EMD Value
₹19,500
Closing Date
12 Dec 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE Indpt Pachmarhi
AGE Indpt Pachmarhi Dist- Hoshangabad (MP)-461881
SPL REPAIR TO BLDG NO 19 (QUARTER MASTER OFFICES) AT AEC TRG COLLEGE and CENTRE, PACHMARHI
2022_MES_561874_1
CA No. AGE(I)/PACH/of 2022-23 (8516/E8)
Open Tender
Civil Works
Item Rate
180 days
Pachmarhi MP
Class E Category a(i)
8 documents required · 8 mandatory
₹500
AGE Indpt Pachmarhi
₹19,500
Yes
16 Jan 2023
7 Nov 2022
14 Dec 2022
7 Nov 2022
12 Dec 2022
21 Nov 2022
Amount
M&L preparation of old decorated surfaces of wall and applying two coat of cement based paint complete all as specified and directed.
M&L preparation of old decorated surfaces of wall and applying two coat of oil bound distemper including filling of minor nail hole with wall putty complete all as specified and directed.
M&L Preparing old wooden surfaces exceeding 10Cm in width or girth and applying two coats of synthetic enamel paint over a coat of primer complete.
M&L Preparing old steel surfaces exceeding 10Cm in width or girth and applying two coats of synthetic enamel paint over a coat of primer complete.
M&L preparation of new plastered or unplastered surfaces of wall and applying two coats of cement based paint over a coat of primer complete all as specified and directed.
Dismantling of ceiling board with fittings and any description including cover fillets as directed.
M&L for false ceiling at all height of 600x600x15mm mineral fibre perforated ceiling tiles micro looks edge laid on supe fine XL 15mm exposed grid systems with 15mm wide T-section flanges. The frame work comprises of main runner of size 15x32x3000mm spaced at 1200mm centre securing fixed to the structural soffits by approved hangers at 1200mm maximum centers. Hangers (GI wire of 4.0 mm dia) to be fixed by approved roof plug, level adjusters and screws etc. The last hanger at the end of each main runner should not be greater than 450mm from the adjacent wall flush fitting 1200mm long cross tees of size 15x26x1200mm to interlocked between main runners at 600mm centers to form a 1200mmx600mm module. Cut cross tees longer than that 600mm to be supported independently 600mmx600mm modules to be formed by fitting 600mm long flush fitting cross tees of size 15x26x600mm centrally between the 1200mm cross tees perimeter wall angle of size 19x19x3000mm secured to wall at 450mm maximum centers. Finally mineral fibre tile 15mm thick micro look edge has to be laid on the 600mmx 600mm module. .
Demolition of cement concrete (unreinforced) in ground floors and paving n exc 15 cm thickness (below or above ground level) all as specified and directed
M&L 50 mm thick PCC 1:3:6 type C-2 using 20mm graded aggregate as in plinth protection finishing even & fair without using extra cement laid in bays complete.
M&L vitrified tiles tiles10 mm thick (Square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set & jointed in neat cement slurry and pointed in coloured cement to match coloured tiles laid over and including 15 mm thick screed bed or bedding layer in CM (1:4) complete all as specfied and directed.
M&L 25 mm thick cement concrete (1:2:4), type B-0, using 12.50 mm graded aggregate as in floors including finishing the surface rough & even for receiving kota/tiles complete.
M&L plain cement concrete type B1 1:2:4 (20 mm crushed stone aggregate) as in,copings, kneelers, apex stones,bed plates, kerbs, watertroughs and the like includingweathering, slightly roundedor chamfered angles andthroating, as directed
Demolition of brick work built in cement mortar including all quions, arches, pillars, etc complete.
M&L Brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius built in CM (1:6) all as specified
M&L 15 mm thick rendering on fair faces of bk /concrete surfaces in CM (1:6), finished even and smooth (without using extra cement ) complete.
Dismantling timber scantlings as in framed work under 40 sq. cm in section, in any position
S&F for MS framed works as in purline, rafters, column , frame work for door and hard drawn steel in square/rectangular, round or angle section, flat iron fixed with and including iron cleats or other connected plates flate iron wind ties etc incl bending of MS section as requried complete all as specified and as directed.Fe-410 gd 250
M&L preparation of new steel surface and applying two coats of synthetic enameled paint over a primming coat of red oxide etc complete all as specified and as directed
Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and as directed
Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, including ridge of same colour fixed with self tapping screws as specified complete all as specified and as directed
Taking down carefully surface aluminium point wiring with PVC casing-caping (light, fan, socket, bell or power) including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc and making good disturbed surfaces complete. complete all as specified and as directed
M&L for point wiring with 1100 volts grade PVC insulated FR-LSH multistranded copper conductor cable 1.5 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 1.5 sqmm (Green) drawn into and including PVC casing-caping not less than 32x12 mm ISI marked ivory colour with all fittings / fixing accessories and sunken modular GI metal boxes not less than 1.2 mm thick and white modular mounting cover plates with frame for mounting of modular switches, sockets, fan regulators etc as required for the following :- Note :- Sheet cover of different module inclusive in this rate. complete all as specified and as directed
(a) One light point controlled by one switch.
(b) One Exhaust point controlled by one switch.
(c) One socket outlet 6 amp controlled by one switch on the same board with other switches.
(d) One socket outlet 6 amp controlled by one switch on indepdendent board.
M&L for point wiring with 1100 volts grade PVC insulated FR-LSH multistranded copper conductor cable 2.5 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 2.5 sqmm (Green) drawn into and including PVC casing-caping not less than 32x12 mm ISI marked ivory colour with all conduit fittings / fixing accessories and sunken modular GI metal boxes not less than 1.2 mm thick and white modular mounting plates with frame for mounting modular switches, sockets as required for 3 pin 16 amps socket outlet controlled by one switch.
S&F angle holder, insulated polycabonate body with back plate complete. Make - Havells Reo / Anchor Penta PC / SSK / CONA as approved complete all as specified and as directed
S&F modular switch one way 6 amp 1 module all as per Legrand Mylinc cat ref no. 675501 or equivalent in Schneider Zencelo or MK Blenze as approved. complete all as specified and as directed
S&F modular switch one way 16 amp 1 module all as per Legrand Mylinc cat ref no. 675511 or equivalent in Schneider Zencelo or MK Blenze as approved. complete all as specified and as directed
S&F modular socket 6/16 - 2/3 pin combined 2 module all as per Legrand Mylinc cat ref no. 675555 or equivalent in Schneider Zencelo or MK Blenze as approved. complete all as specified and as directed
S&F modular socket 6 amp 2/3 pin combined 2 module all as per Legrand Mylinc cat ref no. 675552 or equivalent in Schneider Zencelo or MK Blenze as approved. complete all as specified and as directed
S&F ceiling fan 1200 sweep AC, 230 V 50 Hz, five star rating white/Ivory colour complete all as directed. Make : Havells (ES NEO)/ Bajaj/ USHA complete all as specified and as directed
Supply and fixing LED luminaire 600x600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders and LED lamp suitable for roof ceiling including connecting with driver three core flexible copper conductor cases of suitable size complete complete all as specified and as directed
M&L earthing complete with galvanized steel earth plate electrode of size 600mm x 600mm x6.0mm thick buried directly under ground vertically to a depth not less than 2.25 meter below ground level with top edge of the plate at a depth not less than 1.5m below ground level connected to and including galvanized iron wire 4.0mm not exceeding 7.5meters for each earth without protection pipe, including test point by means of bolts, nuts, check nuts, and washers made out of GI all as shown on plate No 5 of SSR Part I to the extent applicable to this item including necessary making PCC pit of size 0.3 m x 0.3 m x 0.3 m (inner size) in mix 1:3:6 type C1 with RCC 1:2:4 type B-1, 40 mm thick cover reinforced with 6 mm dia MS bars 3 Nos both ways with lifting hook made out of 6 mm dia bar and testing on completion to achieve value complete all as specified and directed.
S&F MCB distribution board SPN 08 ways powder coated, CRCA steel sheet constructed as per IS : 8623, degree of protection IP 43 - IK 09 with metal double door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required. complete all as specified and as directed
S&F ceiling rose 6 amp, 3 plates polycarbonate body complete. Make - Havells Reo / Anchor Penta PC / SSK as approved complete all as specified and as directed.
M&L for submain wiring alongwith earth continuity conductor with PVC insulated FR-LSH multistranded copper conductor cable (Phase - Red, Neutral - Black, Earth - Green) drawing into and including PVC casing-caping not less than 32x12 mm, ISI marked ivory colour along with accessories of following nominal sizes 2x4 sqmm + 1x4 sqmm earth wire complete.
S&F LED tube light along with fixture 18 w size 4 feet complete all as specified and directed by EIC
S&F MCBs as per load requirement 'C' series of breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs of following ratings:-
(a) Single pole 6 to 32 amp.
(b) Single pole and neutral (SPN) 40 amp.
Taking down MCB distribution boards with incoming and outgoing controls any make, any capacity after disconnecting complete. complete all as specified and as directed
S & F 4 Way Novello vertical TPN distribution boards Double Door 415 V/50 Hz, protection class IP43 As per IS 8623 - III Impact resistance IK09 ,Provision for mounting Earth ,Leakage Relay, SVN Indications & MCCB RCD block way, MCCB+12 modules including taking out the old one. Make: HAGER Cat Pat No. VYV04DM or equivt make and model of LEGRAND/L&T complete all as specified and as directed
S & F MCB four pole 63 Amp complete all as specified and as directed
Supply & fix LED bulk head ,10 W complete all as specified and as directed
Taking out of ceiling/exhaust fan of and capacity from any lacation and refixing of the same after oilimg,greasing and overahauling complete all as directed.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area , 3.5 core 35 sqmm complete all as specified and as directed
Taking down carefully aluminium submain wiring with PVC surface conduit and making good disturbed surfaces complete. complete all as specified and as directed
SUBIR KUMAR ROY
Dev Enterprises
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .