Bill of Quantities
Item Wise
GeM BOQ Items (18 items)
Item No
Item Title
Description
Qty
Unit
Consignee
Delivery (days)
Spec
1
300048107C
VALVE SET FOR ISOLATION WITH WASHING VALVE COMPLETE AS PER FXSL DRG. NO. 9-59022-02 WITH BW WNDS AS PER ANST B 16.25, MATERIAL OF CONSTUCTION FOR BODY and SOLID PLUG CF3M, DULY RADIOGRAPHED AND TESTED, SIZE 8 inch YPE 5207328-BW-1/2 inch KSP SW PURGE. VALVE SHANK OF MAIN VALVE OF SH PATTERN.
1
NO
Dilip Ramdas Patil
402208,STORES, RCF Ltd Thal, Alibag, District Raigad
150
2
300067766
PLUG VALVE PLV205 300 rating TUFLIN 2 inch X 300 rating
2
NO
Dilip Ramdas Patil
402208,STORES, RCF Ltd Thal, Alibag, District Raigad
150
3
300049327
3 inch TUFLIN NON-LUBRICATED PLUG VALVE TYPE 462760 WITH 1/2 inch WA ATTACHMENT, RATING 300 rating BW ENDS, LEVER KPERATED, M.O.C. BODY AND P LUG ASTM A351, GR-CF3M (316L), FLUID UREA SOLUTION FOR MELT UREA TO PRILLINGTOWER PUMP (P-8), M/S XOMOX (I) LTD.
1
NO
Dilip Ramdas Patil
402208,STORES, RCF Ltd Thal, Alibag, District Raigad
150
4
300084608
PTFE SLEEVED NON-LUBRICATED TYPE TWO WAY PLUG VALVE SIZE - 3inch150rating END CONNECTIONS - BW MOC - CF3M
2
NO
Dilip Ramdas Patil
402208,STORES, RCF Ltd Thal, Alibag, District Raigad
150
5
310022438
PLUG VALVE ,MATERIAL BODY & PLUG ASTM A182 GR.F316L/351 GR.CF3M, 150 L BS, BW, SIZE6inch .
1
NO
Dilip Ramdas Patil
402208,STORES, RCF Ltd Thal, Alibag, District Raigad
150
6
310022435
PLUG VALVE, MATERIAL OF BODY and PLUG ASTM A 351 CF3M, 300rating, SOCKETWEL D, NON-LUBRICATED, TEFLON SLEEVED, SIZE1/2inch NB.
20
NO
Dilip Ramdas Patil
402208,STORES, RCF Ltd Thal, Alibag, District Raigad
150
7
300115324
3 WAY PLUG VALVE, 3inch 300, TYPE- SELF LUBRICATED WITH TEFLON BUSHING,RATING- 300 LBS PER ANSI B16.5,VALVE ENDS- FLANGED PER ANSI B16.5-300 LBS R.F.-125RMS, BODY MATERIAL- ASTM A 352 LCB, PLUG TYPE- PORT ARRANGEMENT, PLUG MATERIAL- ASTM A 182 F304, SEAL BUSHING- REINFORCED PTFE SUITABLE FOR 32 DEG.CENTIGRADE-60 DEG.CENTIGRADE TEMP AT 35 KG/CM2 FOR AMMONIA FLUID, OPERATE WITH WRENCH FOR UPTO 4inch
3
NO
Dilip Ramdas Patil
402208,STORES, RCF Ltd Thal, Alibag, District Raigad
150
8
300082449
TWO WAY PLUG VALVE
SIZE 3/4inch NB,
PTFE SLEEVED, SOCKET WELD ENDS, WRENCH OPERATED.
MOC
BODY, PLUG and COVER CAST STAINLESS STEEL AS PER ASTM A351 GRADE CF3,
SLEEVE PTFE
DIAPHRAGM PTFE and SS 304
WEDGE RING PTFE
THRUST COLLAR ASTM A 351 GR. CF8M
ADAPTER ROD CS - POWDER COATED
ALL FASTENERS A193 GR B8 / A194 GR 8 ONLY.
STANDARDS
FACE TO FACE DIMENSIONS AS PER ANSI B 16.10
SOCKET WELD END DIMENSIONS SHALL CONFORM TO ANSI B-16.11
DESIGN STANDARD API 599
PRESSURE and TEMPERATURE RATING AS PER ANSI B 16.34
INSPECTION AND TESTING AS PER API 598
NOTE
1) VENDOR SHALL HYDRAULICALLY TEST THE VALVE AT THEIR WORKS and SUBMIT DOCUMENTARY PROOF FOR THE SAME.
HYDROTEST PRESSURE 1) BODY (BARE BODY) 30 BAR 2) SEAT 22 BAR.
PNEUMATIC SEAT TEST AT 6 BAR.
2) VENDOR SHALL SUBMIT MATERIAL TEST CERTIFICATE FROM MANUFACTURER/NABL ACCREDITED LAB FOR PARTS USED FOR VALVE ASSEMBLY.
25
NO
Dilip Ramdas Patil
402208,STORES, RCF Ltd Thal, Alibag, District Raigad
150
-
9
300048090
SLEEVE PTFE 3inch .FOR TUFLIN VALVES M/S XOMOX(INDIA)MADRAS
10
NO
Dilip Ramdas Patil
402208,STORES, RCF Ltd Thal, Alibag, District Raigad
150
10
300048097
SEAL TOP KIT 3inch .FOR TUFLIN VALVES M/S XOMOX (INDIA) MADRAS.
5
ST
Dilip Ramdas Patil
402208,STORES, RCF Ltd Thal, Alibag, District Raigad
150
-
Stage Documents
Award of Contract
contract_GEMC-511687700292122.pdf
GEM_CONTRACT • 0.12 MB
Documents
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .