Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹90,000Qualified Make: BPL
Model: BPL DF 2509 5G 8 5G 8 GURUDWARA ROAD NIT FARIDABAD HARYANA 121001 | FARIDABAD | HARYANA | 121001 | Make: BPL
Model: BPL DF 2509 | L1 | Qualified | |
| 2 | L2₹98,750+₹8,750 (9.72%)Qualified Make: BPL
Model: BPL DF 2509 D 6 BDA DUPLEX NEAR RAILWAY TRACK ZONE 1 M P NAGAR BHOPAL MADHYA PRADESH 462011 | BHOPAL | MADHYA PRADESH | 462011 | Make: BPL
Model: BPL DF 2509 | L2 | Qualified | |
| 3 | L3₹1 L+₹10,000 (11.1%)Qualified Make: BPL
Model: BPL DF 2509 A 38 1ST FLOOR NARAINA INDUSTRIAL AREA PHASE 1 NARAINA INDUSTRIAL AREA PHASE 1 SOUTH WEST DELHI DELHI 110028 | NEW DELHI | DELHI | 110028 | Make: BPL
Model: BPL DF 2509 | L3 | Qualified | |
| 4 | L4₹1.1 L+₹22,000 (24.4%)Qualified Make: BPL
Model: BPL DF 2509 A 1 3 A 1 3 ALIGANJ ALIGANJ LUCKNOW UTTAR PRADESH 226024 | LUCKNOW | UTTAR PRADESH | 226024 | Make: BPL
Model: BPL DF 2509 | L4 | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
9 Oct 2018, 4:00 pmClosed
Defibrillator with CPR Monitoring and TC Pacing ( PAC Only ) Defibrillator With CPR Monitoring And TC Pacing ( 1 ) ( Under PAC ) Make bpl Model bpldf2509 Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values Product configuration and features Defibrillator should be light weight
small size with bright coloured display: Yes * Display screen size (diagonal) 7 Any applicable numeric value Defibrillator should be Biphasic waveform with 3 waveform display Yes * Defibrillator should display selected and delivered energy
both Yes * Ability to select energy
from paddles as well as from the Defibrillator unit Yes * 1/3 Manual mode of the unit should provide energy selection at: 1 to 10
15
20
30
50
70
85
100
150
200 joules * Have ability to measure chest compression rate and depth in real time with both visual and audible feedback Yes * Ability to display CPR index on screen real time: true true
false Have transcutaneous external pacing with 40 mili second pulse width Yes * Unit should do set test daily with facility to give print out of defibrillator testing report and also have code ready indicator on unit Yes * Ability to filter out CPR artefacts and allowing person to see organised rhythms without interrupting chest compression Yes * Capability to monitor Parameter(s): ECG SPO2
ETCO2
NIBP
ECG Capability of internal defibrillation
if and when required? true true
false Accessories to be supplied with each unit of defibrillator: Li-ion battery - 1 no.
NIBP paediatric/adult cuff with hose - 1 no. each
Reusable airway adapter to be used with ETCO2 mainstream sensor & cable - 1 no.
Multi-function defibrillator/Pacing pads - 24 nos.
Reusable CPR feedback sensor/or similar product reused at least on 90 patients - 2 nos. * Certification & Warranty Certification US FDA approved * Warranty 1 1
3
5 (or higher) * Bold specifications are the golden parameters. Consignees and Quantity 2/3 S.No. Consignee Address Quantity Delivery Days 1 Praveen Kumar 641017
CTC CBE
Thoppamp atti
Coimbatore-641017 1 15
673198
GEM/2018/B/95469
Defibrillator with CPR Monitoring and TC Pacing
15 days
Tamil Nadu; Coimbatore
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Defibrillator with CPR Monitoring and TC Pacing ( PAC Only ) Defibrillator With CPR Monitoring And TC Pacing ( 1 ) ( Under PAC ) Make bpl Model bpldf2509 Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values Product configuration and features Defibrillator should be light weight | - | - | - |
| small size with bright coloured display: Yes * Display screen size (diagonal) 7 Any applicable numeric value Defibrillator should be Biphasic waveform with 3 waveform display Yes * Defibrillator should display selected and delivered energy | - | - | - |
| both Yes * Ability to select energy | - | - | - |
| from paddles as well as from the Defibrillator unit Yes * 1/3 Manual mode of the unit should provide energy selection at: 1 to 10 | - | - | - |
| 15 | - | - | - |
| 20 | - | - | - |
| 30 | - | - | - |
| 50 | - | - | - |
| 70 | - | - | - |
| 85 | - | - | - |
| 100 | - | - | - |
| 150 | - | - | - |
| 200 joules * Have ability to measure chest compression rate and depth in real time with both visual and audible feedback Yes * Ability to display CPR index on screen real time: true true | - | - | - |
| false Have transcutaneous external pacing with 40 mili second pulse width Yes * Unit should do set test daily with facility to give print out of defibrillator testing report and also have code ready indicator on unit Yes * Ability to filter out CPR artefacts and allowing person to see organised rhythms without interrupting chest compression Yes * Capability to monitor Parameter(s): ECG SPO2 | - | - | - |
| ETCO2 | - | - | - |
| NIBP | - | - | - |
| ECG Capability of internal defibrillation | - | - | - |
| if and when required? true true | - | - | - |
| false Accessories to be supplied with each unit of defibrillator: Li-ion battery - 1 no. | - | - | - |
| NIBP paediatric/adult cuff with hose - 1 no. each | - | - | - |
| Reusable airway adapter to be used with ETCO2 mainstream sensor & cable - 1 no. | - | - | - |
| Multi-function defibrillator/Pacing pads - 24 nos. | - | - | - |
| Reusable CPR feedback sensor/or similar product reused at least on 90 patients - 2 nos. * Certification & Warranty Certification US FDA approved * Warranty 1 1 | - | - | - |
| 3 | - | - | - |
| 5 (or higher) * Bold specifications are the golden parameters. Consignees and Quantity 2/3 S.No. Consignee Address Quantity Delivery Days 1 Praveen Kumar 641017 | - | - | - |
| CTC CBE | - | - | - |
| Thoppamp atti | - | - | - |
| Coimbatore-641017 1 15 | - | - | - |
Exempted
9 Oct 2018
28 Sept 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_673198.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .