Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹1.6 LAdmitted-Finance | -32.24% | ₹1.6 L | L1 | Admitted-Finance |
| 2 | L2₹2.0 LAdmitted-Finance B 26 DSIDC SHOPPING COMPLEX CENTER KALYANPURI DELHI 110091 | EAST | DELHI | 110091 | -12.99% | ₹2.0 L | L2 | Admitted-Finance |
| 3 | L3₹2.3 LAdmitted-Finance 15 119 DAKHINPURI NEW DELHI 110062 | SOUTH | DELHI | 110062 | -1.00% | ₹2.3 L | L3 | Admitted-Finance |
Tender Value
₹2.3 L
EMD Value
₹4,636
Closing Date
28 Apr 2026, 3:00 pmClosed
Assistant Engineer (E) SD-III
O/o The Assistant Engineer (E), PWD, EMSD-3 (M-South), Police Complex, Malviya, New Delhi
Providing, Servicing and Routine maintenance of WTAC/STAC/Refrigerater installed at MLA Office, Malviya Nagar Constituency
2026_PWD_290207_1
06EE(E) /EMD South Elect. Divn./PWD/2026-27
Open Tender
Electrical Works
30 days
New Delhi
Please refer Tender documents.
13 documents required · 13 mandatory
₹0
₹4,636
Yes
30 Apr 2026
22 Apr 2026
28 Apr 2026
22 Apr 2026
28 Apr 2026
22 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Servicing , repairing of WTAC / STAC type ac units installed at various location i/c cleaning of cooling coil, greasing of blower units as well as replacement of burnt wire complete as reqd. | |||||
| 2Supplying & charging of R-22/R-32/R-410 A refrigering gas in the 1.5 TR/2.0 TR Capacity Window/ Split type AC/Refrigerator i/c necessary copper pipe capillary & filter i/c pressure testing and flushing the complete system and gas charging complete as reqd. | |||||
| 3Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for Split AC, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for suction and Liquid lines, all accessories as per specifications etc. as required : i/c credit of old dismental material as and where basis etc. | |||||
| 3.1 | 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation | - | Mtrs. | - | - |
| 3.2 | 12.7 mm dia (OD) (Softdrawn) with tube thickness 1.2 mm with 19 mm thick insulation | - | Mtrs. | - | - |
| 4Replacement of following material for WTAC / split units: and when as reqd. i/c credit of old dismental material as and where basis etc. Condenser fan/blower blade for WTAC | |||||
| 4.1 | 1.5/2 TR | - | Nos. | - | - |
| 4.2 | Indoor blower | - | Nos. | - | - |
| 4.3 | AC Motor - ¼ To ⅛ HP (Copper winding) | - | Nos. | - | - |
| 4.4 | Front grill of WTAC. | - | Nos. | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.90 MB
BOQ_385246.xls
BOQ • 0.29 MB
FullNIT.pdf
Tender Documents • 2.89 MB
Download all tender documents and submit your bid