Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹26.5 LAccepted-AOC | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹27.5 L+₹52,190 (1.93%)Rejected-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NORTH | DELHI | 110006 | L-2 | Rejected-Finance L-2 | |
| 3 | L-3₹29.7 L+₹2.7 L (10.1%)Rejected-Finance | L-3 | Rejected-Finance L-3 | |
| 4 | L-4₹38.5 L+₹11.5 L (42.6%)Rejected-Finance | L-4 | Rejected-Finance L-4 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
12 Jul 2023, 6:00 pmClosed
GE (AF) FARIDABAD
GE (AF) FARIDABAD
REPAIR/REPLACEMENT OF LOW VOLTAGE PANELS, KIOSK BOX, AIR BREAKER SWITCH AND REPAIR/ROUTINE MAINTENANCE OF DG SETS, AMF PANELS AND OTHER MISC E/M ITEMS INSTALLATION AT DIFFERENT LOCATION AT AF STN DADRI IN AOR OF GE (AF) FARIDABAD (2ND CALL)
2023_MES_596787_2
GE (FBD)/AF-21/2023-2024
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
DADRI
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) FARIDABAD
₹80,000
Yes
21 Sept 2023
28 Jun 2023
14 Jul 2023
28 Jun 2023
12 Jul 2023
28 Jun 2023
Amount
S & F in replacement of hot pressed moulded SMC boxes with hinged door fixing of size 230 mm x 170mmx105 mm complete with suitable aluminium busbar 4 Nos fixed in side the box complete all as specified and directed byh Engineer-in-Charge.
S&F Busbar boxes including aluminium busbar grout with proper nut, bolts fixing on wall proper connection with lugs including painting, making good surface complete all as specified and directed byh Engineer-in-Charge.
Supplying installing,in repair testing and commissioning of air break, gang operated, triple pole switch, outdoor, vertical mounting type of capacity 200 amps, ISI marked, mechanically operated on insulators and frame work with operating mechanism worked from ground level, with locking arrangements including 65 mm pad lockes with two keys, complte with fuse mounts, fuse carriers and HT fuse elements having suitable rating rating suitable for HT 11 KV, 50 Hz Ac Supply incl necessary electric connections complete all as specified and directed byh Engineer-in-Charge.
Dismantling & taking down old, deteriorated, lightening, arrestor and supply and fixing litghtening arrestor expulsion type complete with all fittings transmission class discharge capacity 65 Kilo Amp suitable for 11000 Volts complete all as specified and directed byh Engineer-in-Charge.
M&L for Servicing, testing, commissioning of VCB battery charger, battery for VCB including all minor spare parts complete all as specified and directed byh Engineer-in-Charge.
M&L for painting of old LT panels of any size and descreption with two coat anti corrosive synthetic enamelled smoke gray paint or as per existing condition required on site incl rubbing old surface with emery paper complete all as specified and directed byh Engineer-in-Charge.
M&L for Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion all excavation and earth work & connectiing the earthing complete all as specified and directed byh Engineer-in-Charge.
All as above item No 09 but with earthing lead 25 x 4 mm GI strip complete all as specified and directed byh Engineer-in-Charge.
All as above item No 09 but, but using copper plate 60×60cm ×3.15mm thick electrode and 20×3mm copper strip as earthing lead complete all as specified and directed byh Engineer-in-Charge.
M&L and testing for Advance Maintenance Free environment friendly chemical earthing as per IS 3043 with copper strip of size 40 x 6 mm, 3 mtr long, 50mm dia outer pipe of thickness 2mm filled with highly conducting metellic compound in gel foam and boath end sealed, electrolytic copper eathing electrodes. The earth pits shall be filled with sufficent quality ultra high conductive black fill compound with neccessary accessories like lockable pit cover and PVC 16 sqmm single core multistrand PVC insulated copper conductor drawn in HDPE pipe bore 25mm Including test point terminal block made of gun metal phosphorus bronze of size 75 x 75 x 25 mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hexagonal head screws and Hot dip galvanised sheet 2 mm thick box of size 200 x 100 x 100 mm with Hexagonal head screws 125 mm complete as required all as per standard practices and specifications, complete all as specified and directed byh Engineer-in-Charge. Note: The concrete pit shall be PCC 1:3:6 type c-140 mm thick precast cover slab of RCC (1:2:4) type B-1 using 20mm aggregate reinforced with 8mm TMT bars @ 10 cmm c/c on both sides with suitable cast iron handle shall be provided in liew of cost iron cover shown in the electrical plate No. 3 MES SSR Part - I
S & F Earthing lead 25 x 4 mm GI strip including strip insulators complete all as specified and directed byh Engineer-in-Charge.
Supply & fixing MCCB TPN 63 Amps 16 KA complete all as specified and directed byh Engineer-in-Charge.
All as item ser No 14 above but 100 Amps 16 kA complete all as specified and directed byh Engineer-in-Charge.
All as item ser No 14 above but 125 Amps 415 Volts 16 kA complete all as specified and directed byh Engineer-in-Charge.
Supply & fixing of MCCB 4 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 36 KA complete all as specified and directed byh Engineer-in-Charge.
All as per item No 17 above but TPN 200 Amps 415 volts 36 kA complete all as specified and directed byh Engineer-in-Charge.
All as per item No 17 above but TPN 250 Amps 415 volts 36 kA complete all as specified and directed byh Engineer-in-Charge.
All as per item No 17 above but TPN 400 Amps 415 volts 36 KA complete all as specified and directed byh Engineer-in-Charge.
Supply & Fixing in repair of Four Pole Contactor, 415V AC, 2 NO+NC, 250 Amp complete all as specified and directed byh Engineer-in-Charge.
All as per item No 21 above but 160 Amps complete all as specified and directed byh Engineer-in-Charge.
All as per item No 21 above but upto 100 Amp complete all as specified and directed byh Engineer-in-Charge.
S & F OFF load Change Over Switch 250 Amps 4 pole 415 Volt complete all as specified and directed byh Engineer-in-Charge.
M&L for LT pole painting two coated anti corrosive synthetic enamelled silver paint as per existing condition incl rubbing old surface with emery paper alternate black and yellow 30 cm wide strip upto 1.5 mtr of pole above ground level and marking pole numbers complete all as specified and directed byh Engineer-in-Charge.
M&L for Preparation of surface Distempering walls with cement paint one coat complete all as specified and directed byh Engineer-in-Charge.
Supply and Fixing including repair/replacement of LED driver 230 volt single phase of 45/48 watt, driver life >= 25000 Hrs efficiency - 85%, with out put short circuit protection all as specified and directed by Engr-in-Charge.
Supply and Fixing including repair/replacement of LED light strip 230 volt single phase of 45/48 watt, driver life >= 25000 Hrs efficiency - 85%, with out put short circuit protection complete all as specified and directed byh Engineer-in-Charge.
M & L for replacement of cable PVC insulated unarmored for connection 1.5 sqmm x 2 core Copper conductor duly drawn MS conduit 20 mm dia from cut out junction box to street light fittings on poles including PVC flexible pipes complete all as specified and directed byh Engineer-in-Charge.
M&L for Mild steel plates, plain or chequered, 5mm thick or over in thickness in available sizes complete all as specified and directed byh Engineer-in-Charge.
S&F Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size complete all as specified and directed byh Engineer-in-Charge.
M&L for Preparation of surface Distempering walls with distemper oil emulsion one coat complete all as specified and directed byh Engineer-in-Charge.
Taking down chowkhats or frames exc 1.5 sq. m but n exc 4 sq m each with shutters (without taking off shutters from the frames) etc complete all as specified and directed byh Engineer-in-Charge.
Taking down chowkhats or frames n. exc. 1.50 sqm each (without taking off shutters from the frames) etc complete all as specified and directed byh Engineer-in-Charge.
M&L precast cement concrete type-B1 1:2:4 by using 20 mm graded crushed broken stone aggregate, in window or door cills, lintels, bressumers, steps, quoin blocks (for use with masonry), string courses, copings set in cement mortar 1:4 complete all as specified and directed byh Engineer-in-Charge.
S&F for ECO 2000 series Approx size of 1.65 m x 1.2 m (Elixir/NCL SECCOLOR ) Roll framed galvanised prepainted steel section windows section including provision of grills, 4 mm thick glass and SS wiremesh specification and drawing as per CE (AF) WAC, PALAM sheet no -1/2 and 2/2 of drawing no-CEAF/STD-191/2014 etc complete all as specified and directed byh Engineer-in-Charge. (a) Fixing details:- frame and shutter frame sections should be cut to lenth and miter joined with poly propylene corner brackets, mullion section should be joined with frame/mullion using nylon mullion cap, ethyl propyllene diamene monomer(EPDM) gasket should be used all around glass in shutter and fixed glass. Rubber gasket should be used aroud the fly mesh to fix mesh in mesh shutter. (b) Accessories:- Each Glazed shutter should be provided with MS powder coated friction hinges, high grade aluminium powder coateed handle -1 for each shutter. (c) Glass shutters having fixed glass shall be 4 mm th orion blue (ET725) GLASS, having U value of 3.85 W/sqm K, light transmission factor of 18% and solar radiation factor of 0.23 fo ST Gobin, HNG OR MODIGUARD (d) Windows should be provided with grill made of 10mm SQR. MS Bars welded to at 150 mm centre to centre, 6mm x 12mm MS flat. Total grill unit should be powder coated and fixed to window frame with screws. (e) Window frame should be fixed to brick/concrete masonry by using nylons self expanding caps and driving MS electroplated 80 mm long screws into the caps through frames. (f) Mesh shutter should be provided with a stainless steel 32 gauge fly mesh of 304 grades with 144 holes per Sqr.inch.
M/L for Brick works with old size sub class 'B' bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed byh Engineer-in-Charge.
M&L 15mm thick rendering in cm 1:4 on fair surfaces of walls finished even and smooth w/o using extra cement complete all as specified and directed byh Engineer-in-Charge.
M&L for applying two coats of cement based paint on walls in different patterns including preparation of new plastered surfaces complete all as specified and directed by Engineer-in-Charge.
M&L for preperation of new plastered surface and applying two coats of oil bound distemper on walls over a coat of 3 mm thick wall care putty complete all as specified and directed byh Engineer-in-Charge.
M&L 15 mm thick rendering in cm 1:6 on brick surfaces or concrete surfaces finished even and smooth without using extra cement incl mixing of water proofing liquid of Dr. fixit as per manufactrer instruction complete all as specified and directed by Engineer-in-Charge. (Note:- Plastering work to be done upto height of 30 mtr for RCC OHT as per site requirement.)
M&L for rendering 10mm thick in CM 1:3 on concrete surface in ceillings etc including with mixing of water proofing liquid of Dr. fixit as per manufactrer instruction complete all as specified and directed by Engineer-in-Charge.
M &L for applying two coat of external emulsion paint over 3 mm thick wall care putty complete all as specified and directed by Engineer-in-Charge.
M&L two coat of oil bound distemper after 3mm Birla/JK wall care putty on new plastered surfaces including necessary prepararion complete all as specified and directed by Engineer-in-Charge.
Taking down cement plaster from brick or stone masonry or concrete surfaces and hacking for key and scrubbing down with water etc all as specified (Note:- Taking down Plastering work to be done upto height of 30 mtr for RCC OHT as per site requirement.), complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 15 mm thick in CM 1:4 on stone masonary or surface other than fair face of brick works etc or similar surfaces etc including with mixing of water proofing liquid of Dr. fixit Qty as per manufactrer instruction complete all as specified and directed by Engineer-in-Charge.
Dismantling floor, hearth or wall tiling or stone flooring including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer-in-Charge.
M&L for coloured printed non skid tiles area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm in floors etc set and jointed with neat cement slurry pointed with colour cement to match the floor, and including 15 mm thick screed bed cement mortar in CM 1:4 and including the chipping of the existing PCC floor complete all as specified and directed by Engineer-in-Charge.
M&L for digital design glazed ceramic tiles in vertical surface of size of each tile 350 x 250 mm and 7 to 8 mm thick fixed to wall with 10 mm thik cement sand mortar in CM 1: 4 , set and joint in neat cement slurry and pointed in white or coloured cement to match the same complete all as specified and directed by Engineer-in-Charge.
M&L for cross arms (MC 75), bracings, supports, clapms and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one prime coat, one under coat and one finishing coat paint complete all as specified and directed by Engineer-in-Charge.
M&L for General Servicing of DG sets upto 62.5 KVA , at run of 500 hours or 5 months which ever comes first (twice in Contract period based on condition ) comprising of following jobs i/c Transportation, Labour charges & minor material required for servicing etc. as reqd complete all as specified and directed by Engineer-in-Charge. (i) Cleaning & greasing of the parts. (ii) Tappet setting as per standard (iii) Fan belt, tensioner pulley and lever adjustments. (iv) Tightening of all the nuts, bolts and clamps. (v) Testing & checking of AC & DC Wiring. (vi) Self & Charging Alternator cleaning and testing, checking of working & minor fault removal. (vii) Checking of Supply & return fuel pipes from fuel tank to engine. (viii) Checking of FIP timing by Fuel cut off method.
All as Item No. 51 Above but DG set 75 KVA complete all as specified and directed by Engineer-in-Charge.
All as Item No. 51 Above but DG set 160 KVA complete all as specified and directed by Engineer-in-Charge. .
Supply only diesel filter suitable for capacity upto 62.5 KVA DG set Primery & secondary set complete all as specified and directed by Engineer-in-Charge.
All as per item No 54 but capacity from 75 KVA upto 160 KVA primary and secondary set complete all as specified and directed by Engineer-in-Charge..
Supply only Engine oil filter suitable for capacities of DG sets upto 62.5 KVA complete all as specified and directed by Engineer-in-Charge.
All as per item No 56 but capacity from 75 KVA upto 160 KVA complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair / replace of Air cleaner elements inner and outer for DG sets upto 62.5 KVA complete all as specified and directed by Engineer-in-Charge.
All as per item No 58 but capacity from 75 KVA upto 160 KVA complete all as specified and directed by Engineer-in-Charge.
M&L for Dismantling the radiator and fan from the engine for cleaning of copper tubes and cooling fins by descaling solution and using air compressor ,soldering on leakage, patch work and re-assembling the radiator and fitted with DG set properly including replacement of radiator hose pipe with clamps and bolt/nut with washer , leak check and pressure testing including transporting to repair workshop and bringing back for upto 62.5 KVA complete all as specified and directed by Engineer-in-Charge.
All as per item No 60 but capacity from 75 KVA upto 160 KVA complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair of Water Pump of Radiator suitable for DG set Radiator up to 62.5 KVA complete all as specified and directed by Engineer-in-Charge.
All as per item No 62 but capacity from 75 KVA upto 160 KVA complete all as specified and directed by Engineer-in-Charge.
M&L for Removal & replacement of flywheel gear ring suitable for upto 62.5 KVA DG set connection & testing complete all as specified and directed by Engineer-in-Charge.
All as per item No 64 but capacity from 75 KVA upto 160 KVA complete all as specified and directed by Engineer-in-Charge.
M&L for Removal & replacement of thermostat suitable for upto 62.5 KVA DG set connection & testing complete all as specified and directed by Engineer-in-Charge.
All as per item No 66 but capacity from 75 KVA upto 160 KVA complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of copper terminal end suitable for batteries of capacity 12V 180AH complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair of AVR for DG set having capacity upto 62.5 KVA complete all as specified and directed by Engineer-in-Charge.
All as per item No 69 but capacity from 75 KVA upto 160 KVA complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair for all type of hose pipe with clamps , over flow pipe, copper tube fuel supply pipe, etc with clip and complete fittings suitable for DG set upto 62.5 KVA complete all as specified and directed by Engineer-in-Charge.
All as per item No 71 but capacity from 75 KVA upto 160 KVA complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in repair of Battary Charger 12V DC, 5 Amp of Autocut Electrical Battery Charger Unit SMPS with Constant Voltage Output with Battery Charging Transformer and Moulded Rectifier Unit etc suitable for smoothing functioning of DG set as required on site complete all as specified and directed by Engineer-in-Charge.
All as per item No 73 but capacity Battary Charger 24V DC, 10 Amp complete all as specified and directed by Engineer-in-Charge.
Supply only distil water for top up in Batteries complete all as specified and directed by Engineer-in-Charge.
Supply only electrolyte battery solution (Dilute sulphuric acid have specific gravity 1210 degree) in 10 litrs sealed gallon packing complete all as specified and directed by Engineer-in-Charge.
Supply only filling Premixed coolent complete all as specified and directed by Engineer-in-Charge.
Supply and filling in sump/topping up engine oil, multi grade 20w40 in engine or relpacement of engine oil complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in repair of DC 12V Stop Solenoid suitable for DG Set complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in repair of DC 24V Self Solenoid Coil suitable for DG Set complete all as specified and directed by Engineer-in-Charge.
Supply and replacement of Bty 12 Volt 80 AH suitable DG set complete all as specified and directed by Engineer-in-Charge.
Supply and replacement of Bty 12 Volt 180 AH suitable DG set complete all as specified and directed by Engineer-in-Charge.
M&L for repairing of self starter of DG set capacity 12 Volts including transporting upto workshop to carry out necessary replacement of burnt copper winding with new copper winding/ coil of existing gauge from rotor and stator coil, cleaning of slots, dryings varnishing and proper insulating to winding complete all as specified and directed by Engineer-in-Charge.
All as per item No 83 but capacity 24 Volts complete all as specified and directed by Engineer-in-Charge.
S & F Copper Battery leds suitable for Bty 12V complete all as specified and directed by Engineer-in-Charge.
Supply, fixing and testing for smoothing fuctioning Fan Belt suitable for DG set up to 62.5 KVA complete all as specified and directed by Engineer-in-Charge.
All as per item No 86 but capacity from 75 KVA upto 160 KVA complete all as specified and directed by Engineer-in-Charge.
Material and Labour for replacement of crank shaft of DG set having capacity upto 62.5 KVA complete all as specified and directed by Engineer-in-Charge.
Material and Labour for replacement of crank shaft of DG set having capacity from 75 KVA to 160 KVA complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in repair of Four Pole Contactor, 415V AC, 2 NO+NC, 250 Amp complete all as specified and directed by Engineer-in-Charge.
All as per item No 90 above but 160 Amps complete all as specified and directed by Engineer-in-Charge.
All as per item No 90 above but upto 100 Amp complete all as specified and directed by Engineer-in-Charge.
Material and Labour for fixing white boards 5' x 4' with blue letters standard sizes with colour codes as per site details of Line digram / Machine History /Distribution boards complete all as specified and directed by Engineer-in-Charge.
M&L for overhauling of solar battery by disconnecting battery from GI pole and removel of suphation, cleaing of plate and all parts painting of poles Bty box etc with two coats of aluminium silver paints and fill up distil water full as required and testing after reassembling complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement Solar Bty suitable for Solar light 43 Watt 12 V as per existing specification complete all as specified and directed by Engineer-in-Charge.
Supply, Fixing and testing solar street light LED fitting suitable solar light 43 Watt as per existing specification complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement Charge controller/drive circuit suitable for solar light upto 43 Watt as per existing specification complete all as specified and directed by Engineer-in-Charge.
M&L for Taking down old U/S solar water heater of 100 LPD capacity incl dismantling and removal from staging of tank cold water tank and taking down all connections hot and cold water pipe line connections and electric supply connections and removal of all items from roof top for carrying out repair and servicing and re fixing complete all as specified and directed by Engineer-in-Charge.
S & F Heating element 3 KW with thermostat for electrical Back up suitable of solar geyser as existing model complete all as specified and directed by Engineer-in-Charge.
M&L for repair/ maintenanance opening of AMF Panel, Cleaning of dust using blower & cleaning agents. Checking/Detecting, Removal of Faults, Re-wiring of old u/s wiring & Testing of Control Wiring complete as reqd for diesel generating set of upto 62.5 KVA capacity three phase 415 Volts, 50 HZ AC with all standard features, safeties etc., complete all as specified and directed by Engineer-in-Charge.
M&L for repair/ maintenanance opening of AMF Panel, Cleaning of dust using blower & cleaning agents. Checking/Detecting, Removal of Faults, Re-wiring of old u/s wiring & Testing of Control Wiring complete as reqd for diesel generating set of from 75 KVA to 160 KVA capacity three phase 415 Volts, 50 HZ AC with all standard features, safeties etc., complete all as specified and directed by Engineer-in-Charge.
M&L for repair maintenance of Steel rolling shutters greasing and sythetic enemal paint blue / black colour, including ball bearing, anchoring rod, hasp and staple push pull or manual type but gear operated type with bevel gear box and crank handle as per site requirement complete all as specified and directed by Engineer-in-Charge.
M/S Anand Enterprises
H.B. Traders
M/S Yamin
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .