Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
21 Feb 2023, 2:00 pmClosed
Executive Engineer JPDCL ED Kathua
Office of the Executive Engineer JPDCL ED Kathua
Execution of works for redressal of Public Demand from Panchayat Makwal Block Nagrota regarding Laying of HT/LT Network etc on Turnkey Basis
2023_PDD_203913_1
KED/45 of 2022-23 Dt.30.01.2023
Open Tender
Electrical Works
Turn-key
60 days
kathua
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
Executive Engineer JPDCL ED Kathua
₹60,000
3 Mar 2023
2 Feb 2023
23 Feb 2023
2 Feb 2023
21 Feb 2023
2 Feb 2023
2 Feb 2023 - 11 Feb 2023
Amount
Creation of 25 KVA Sub Station at Khrari Pyt Makwal on Turnkey Basis by way of Supply, Erection/Installation, Testing, commissioning etc of the following material:
11/0.433kV, 25 KVA, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, (Al wound ), and with LV Cable Box having detachable Aluminium Gland plate.
Gapless Surge Arrestor,9 kV ,10 KA ,LA with polymer housing, Stn. Type
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
11 kV Horn Gap Fuse Set 3 Phase 200A
50 mm² (1Ckt) Single Phase Cable,1.1K V Grade, PVC Insulated Stranded Conductor FRLS type
9 Mtr. Long PCC Pole(WL-300 Kg )
11KV Polymeric composite Disc Insulator 12kV,min failing load 45KN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
GI Channel/Angle/Flat of sizes including clamps
Galvinized Nuts and Bolts.
Cement Bottoming 1:2:4 mix as per REC Standards
Earthing of substation-Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
Pre fabricated LT Distribution switch
Danger Plates with Clamps
Sundary Items
GI Barbed wire for anti climbing
Laying of HT line on 9 Mtrs.PCC poles with ACSR Weasel Conductor at Khrari Pyt Makwal on Turnkey Basis by way of Supply, Erection/Installation, Testing, commissioning etc of the following material:
9 Mtr. Long PCC Pole(WL-300 Kg )
GI V cross-arm/Horizontal with top Bracket including clamp
GI Channel x-arm includingclaps and braces
30 mm² ACSR Conductor
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Galvanized Nuts and Bolts
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Danger Plates with Clamp
Anti Climbing Devices with clamps
Earthing Complete by GI Pipe 40mm dia or GI Rod 20mm ,2.5 mtrs long through GI Strip
Laying of LT line on 8 Mtrs.PCC poles with ACSR Weasel Conductor 3 Phase 4 wire at at Khrari Pyt Makwal on Turnkey Basis by way of Supply, Erection/Installation, Testing, commissioning etc of the following material:
8 Mtr. Long Pole(PCC WL-200Kg )
GI U-Clamp for Shackle insulators
Shackle insulator 16 KN
30 mm² ACSR Conductor
Galvanized Nuts and Bolts
Danger plates
Anit Climbing Device with Clamps
Earthing Complete by GI Pipe 40mm dia or GI Rod 20mm ,2.5 mtrs long through GI Strip
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
LT line Spacers
Stone Pad
Alm.Jointing Sleeves
Creation of 25 KVA Sub Station at Chamba Da Bagh Pyt Makwal on Turnkey Basis by way of Supply, Erection/Installation, Testing, commissioning etc of the following material:
11/0.433kV, 25 KVA, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, (Al wound ), and with LV Cable Box having detachable Aluminium Gland plate.
Gapless Surge Arrestor,9 kV ,10 KA ,LA with polymer housing, Stn. Type
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
11 kV Horn Gap Fuse Set 3 Phase 200A
50 mm² (1Ckt) Single Phase Cable,1.1K V Grade, PVC Insulated Stranded Conductor FRLS type
9 Mtr. Long PCC Pole(WL-300 Kg )
11KV Polymeric composite Disc Insulator 12kV,min failing load 45KN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
GI Channel/Angle/Flat of sizes including clamps
Galvinized Nuts and Bolts.
Cement Bottoming 1:2:4 mix as per REC Standards
Earthing of substation-Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
Pre fabricated LT Distribution switch
Danger Plates with Clamps
Sundary Items
GI Barbed wire for anti climbing
Laying of HT line on 9 Mtrs.PCC poles with ACSR Weasel Conductor at Chamba Da Bagh Pyt Makwal on Turnkey Basis by way of Supply, Erection/Installation, Testing, commissioning etc of the following material:
9 Mtr. Long PCC Pole(WL-300 Kg )
GI V cross-arm/Horizontal with top Bracket including clamp
GI Channel x-arm includingclaps and braces
30 mm² ACSR Conductor
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Galvanized Nuts and Bolts
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Danger Plates with Clamp
Anti Climbing Devices with clamps
Earthing Complete by GI Pipe 40mm dia or GI Rod 20mm ,2.5 mtrs long through GI Strip
Laying of LT line on 8 Mtrs.PCC poles with ACSR Weasel Conductor 3 Phase 4 wire at Chamba Da Bagh Pyt Makwal on Turnkey Basis by way of Supply, Erection/Installation, Testing, commissioning etc of the following material:
8 Mtr. Long Pole(PCC WL-200Kg )
GI U-Clamp for Shackle insulators
Shackle insulator 16 KN
30 mm² ACSR Conductor
Galvanized Nuts and Bolts
Danger plates
Anit Climbing Device with Clamps
Earthing Complete by GI Pipe 40mm dia or GI Rod 20mm ,2.5 mtrs long through GI Strip
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
LT line Spacers
Stone Pad
Alm.Jointing Sleeves
Laying of LT line on 8 Mtrs.PCC poles with ACSR Weasel Conductor 1 Phase 2 wire at Pyt Makwal on Turnkey Basis by way of Supply, Erection/Installation, Testing, commissioning etc of the following material:
8 Mtr. Long Pole(PCC WL-200Kg )
GI U-Clamp for Shackle insulators
Shackle insulator 16 KN
30 mm² ACSR Conductor
Galvanized Nuts and Bolts
Danger plates
Anit Climbing Device with Clamps
Earthing Complete by GI Pipe 40mm dia or GI Rod 20mm ,2.5 mtrs long through GI Strip
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
LT line Spacers
Stone Pad
Alm.Jointing Sleeves
Laying of LT line on 8 Mtrs.ST poles with ACSR Weasel Conductor 1 Phase 2 wire at Pyt Makwal on Turnkey Basis by way of Supply, Erection/Installation, Testing, commissioning etc of the following material:
8 Mtr. Long Pole(ST-410 SP-15 )
GI U-Clamp for Shackle insulators
30 mm² ACSR Conductor weasel
16 KN Polymer Shackle insulators
Galvanized Nuts and Bolts
Danger Plates with Clamp
Anti climbing Devices with Clamp
Earthing Complete by GI Pipe 40mm dia or GI Rod 20mm ,2.5 mtrs long through GI Strip
Red oxide Paint
Aluminium Paints
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Replacement/insertion of damage Pole in LT line with 8 mtrs PCC Pole at Pyt. Makwal on Turnkey Basis by way of Supply, Erection/Installation, Testing, commissioning etc of the following material: Note:- All the dismantlled reuseable material shall be returned to Divisional Store at kathua at no cost.
PCC pole 8 mtrs.long(W/L-200 Kg)
GI U Clamp for shackle insulator
16 KN Polymer shackle insulstor
Galvanised Nuts and bolts
30mm2 ACSR Weasel Conductor
Rreplacement of old LT Conductor at Pyt Makwal on Turnkey Basis by way of Supply, Erection/Installation, Testing, commissioning etc of the following material: Note:-All the dismantlled reuseable material shall be returned to Divisional Store at kathua at no cost.
30mm2 ACSR Weasel Conductor
GI U Clamp for shackle insulator
16 KN Polymer shackle insulstor
Galvanised Nuts and bolts
M/S MAHALAXMI ENTERPRISES
COUNTRY CONSTRUCTION
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .