| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.4 LAccepted-AOC | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹48.8 L+₹2.4 L (5.17%)Rejected-Finance AT ROAD NEAR RENUKA CINEMA P O DIST TINSUKIA ASSAM PIN 786125 | TINSUKIA | TINSUKIA | ASSAM | 786125 | L2 | Rejected-Finance Rejected being L2 | |
| 3 | L3₹48.9 L+₹2.5 L (5.34%)Rejected-Finance | L3 | Rejected-Finance Rejected being L3 | |
| 4 | L4₹49.0 L+₹2.6 L (5.54%)Rejected-Finance 1389 RADHETENAMENT SOCIETY SARDAR ROAD SURENDRANAGAR SURENDRA NAGAR GUJARAT 363001 | SURENDRANAGAR | GUJARAT | 363001 | L4 | Rejected-Finance Rejected being L4 | |
| 5 | L5₹49.4 L+₹3.0 L (6.52%)Rejected-Finance AT ROAD HATIALI PO CHABUA DIST DIBRUGARH ASSAM 786184 | CHABUA | DIBRUGARH | ASSAM | 786184 | L5 | Rejected-Finance Rejected being L5 |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
15 Oct 2024, 6:00 pmClosed
GE AF Chabua
Office of GE AF Chabua, PIN-786102
AS per BOQ details
2024_MES_674665_1
627/E8
Open Tender
Civil Works
Item Rate
180 days
Chabua
As per tender document
8 documents required · 8 mandatory
₹500
GE AF Chabua
₹94,000
Yes
21 Oct 2024
14 Sept 2024
17 Oct 2024
14 Sept 2024
15 Oct 2024
8 Oct 2024
Amount
Supply laying & testing of XLPE insulated, armoured, heavy duty electric under ground cable with stranded aluminum conductor, 1100 volts grade, laid in trenches, sleeving through pipes or fixed on poles & walls or laid under floors including jointing with suitable size aluminum lugs including taking down of old unserviceable cable complete of size 70 Sqmm nominal cross section 3.5 core complete all as specified and as directed.
All as per ser item No 01 above but Size of cable 50 Sqmm X 3.5 core
All as per ser item No 01 above but Size of cable 25 Sqmm X 4 core
All as per ser item No 01 above but Size of cable 16 Sqmm X 4 core
All as per ser item No 01 above but Size of cable 16 Sqmm X 2 core
Supply and lay cable insulated screened PVC bedded, galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with standarded aluminium conductor of size 150 Sqmm 3.5 Core complete all as specified and ditected ( Lt Panel to UPS conected)
Excavation in trenches nexc 1.5 mtr wide and n exc 1.5 mtr in depth and getting out in soft/ loose for laying cables, erection of poles complete all as specified.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified.
Removing surplus excavated soil nexc 50 mtr and depositing where directed at a level n-exc 1.5 mtr above the starting point.
Supply and laying well burnt Sub Class 'B' locally available best quality laid in trenches perpendicular to UG cable above sand cushioning for cable protection complete all as specified.
Supply and spreading dry coarse sand in trenches for protection of underground electric cable, spread in uniform 23 cm thickness and punned down gently to 18 cm complete all as specified and as directed.
M & L for replacement flood light mounted on high mast light of 200 Watt energy saving, environmental friendly, long life, made up of pressure die-cast aluminium housing with toughened glass and high power LEDs, iP66 protection, suitable for highlighting architectural facade and general purpose lighting after taking down the old unserviceable one complete all as specified and directed (56 Light Disparsal and 8 light high mast)
S&F GI tube light grade 50mm dia with all fitting and laid in floors, under road, pavement or hard standing for protection of earthing strip including takingout GI pipe complete all as specified and directed.
M&L for GI pipe of 40 mm bore and supply & fix GI tube light grade laid in trenches or fixed on wall, floor or on pole for cable protection complete all as specified and directed.
M&L for GI pipe of 25 mm bore and supply & fix GI tube light grade laid in trenches or fixed on wall, floor or on pole for cable protection complete all as specified and directed.
Horizontal Boring by Passing GI Protection Pipe up to 50 mm Bore (dia), under Road /Foot Path, not exc. 10.00 METRE in a Single Length, complete all as specified and as directed.
S&F Cable Junction Box 155x210x92 mm in size, made out of thermoplastic sheet having IP 65/66 protection for outdoor installation fixed on poles with flat aluminium clamps of size 20x3 mm, nuts, bolts, washers etc.including MCB single pole of capacity 6 to 40 A & taking out of old unserviceable cable junction box complete all as specified and as directed.
Supply and fix street light bracket, bend to 120 degree angle, made out of 50 mm bore, galvanised iron, light grade tubing (approx 1.5 mtr in length) including necessary two nos suitable size of clamps with nuts, bolts and washers, etc. and two coats of synthetic enameled paint over a coat of red oxide primer complete all as specified and directed.
S&F in Supply and fixing 6 to 32 Amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning.
M & L for maintenance free chemical earthing system complete with 03 (three) nos copper bonded rods, 17.2 mm dia 3000 mm long electrode buried at suitable distance apart directly in ground, to bore holes of 120 mm dia vertically to a depth not less than 3.60 mtr deep below ground level with top edge of earth electrode at a depth not less than 100 mm below normal ground level, provision of clamps or brazed or both for each copper bonded rods made of copper and copper strip of size 25 x 3 mm & strip connection on the top of the electrode and copper strip of size 25 x 3 mm for inter connection of 03 nos copper bonded rods and laying at least 500 mm below in the ground and further connected to test point terminal block, including back filling of bore holes with advanced earth enhancing compound 96 kilogram (minimum) for artificial treatment to soil so as to achieve earth resistance below 01 Ohms as specified in para 19.140 of SSR Part-1 (2009), including provision of earthing pit in PCC(1:3:6) type C1 pre-cast cover RCC slab of size 400 x 400 x 50 mm with one handle made out of 8 mm dia round bar, including necessary earth work and three coats of white wash on plastered surface (exposed surfaces) and testing complete all as directed and including necessary earth work and testing complete all as specified and directed. Note :-(i) The concrete pit shall be made in PCC 1:3:6 type C-1, using 12.5mm graded crushed stone aggregate 40mm thick precast cover slab of RCC (1:2:4), type B-1, using 20mm graded crushed stone aggregate with suitable MS handle in lieu of CI cover shown in electrical plate No 3 of MES SSR Part-I shall be provided. Reinforcement in RCC cover shall be of 8mm dia TMT bars laid @150mm c/c both ways (ii) Item includes the cost of 9 metre GI pipe for protection of earth strip. Any variation in length shall be measured and paid through deviation order. (iii) Item includes cost of 9 metre earth strips. Any variation in length shall be adjusted through deviation order. (iv) Earth plate electrode shall be surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides.
Earthing complete with galvanised mild steel earth plate electrode 600X600X6 mm thick buried directly inground vertically (earth pit not less than 2.25 m deep below normal ground level) with the top edge of the earth plate electrode at a depth not less than 1.5m below normal ground level and including GI earth strip 32 x 6 mm bolted (with GI nuts, bolts & check nuts) and riveted to earth plate electrode at one end and nected to metallic bodies of HT/LT equipments etc at the other end, earth strip encased in and including 50 mm bore GI medium grade pipe with all fittings from top of earth plate electrode to body of equipment fixed with and including 25x 6mm flat iron clamps, bolts, nuts and washers and including providing watering pipe 20mm bore GI pipe medium grade from Bottom of concrete pit to top of earth plate electrode complete all as specified and shown in electrical plate No 3 of MES SSR Part-I. The scope of work includes necessary excavation and earth work in any type ofsoil, removal of soil upto 50 metre, PCC pit with precast RCC cover, charcoal/salt, funnel, CI frame etc complete. NOTES :- (i)The concrete pit shall be made in PCC 1:3:6 type C-1, using 12.5mm graded crushed stone aggregate 40mm thick precast cover slab of RCC (1:2:4), type B-1, using 20mm graded crushed stone aggregate with suitable MS handle in lieu of CI cover shown in electrical plate No 3 of MES SSR Part-I shall be provided. Reinforcement in RCC cover shall be of 8mm dia TMT bars laid @150mm c/c both ways (ii) Item includes the cost of 7.5 metre GI pipe for protection of earth strip. Any variation in length shall be measured and paid through deviation order. (iii) Item includes cost of 7.5 metre earth strips. Any variation in length shall be adjusted through deviation order. (iv) Earth plate electrode shall be surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides. (At LT Panel)
Earthing complete with copper earth plate electrode 60 x60 cm x 3.15 mm thick buried directly inground vertically (earth pit not less than 2.25 m deep below normal ground level) with the top edge of the earth plate electrode at a depth not less than 1.5m below normal ground level and including copper earth strip of size 20 x 3 mm bolted (with GI nuts, bolts & check nuts) and riveted to earth plate electrode at one end and nected to metallic bodies of HT/LT equipments etc at the other end, earth strip encased in and including 50 mm bore GI medium grade pipe with all fittings from top of earth plate electrode to body of equipment fixed with and including 25x 6mm flat iron clamps, bolts, nuts and washers and including providing watering pipe 20mm bore GI pipe medium grade from Bottom of concrete pit to top of earth plate electrode complete all as specified and shown in electrical plate No 3 of MES SSR Part-I. The scope of work includes necessary excavation and earth work in any type ofsoil, removal of soil upto 50 metre, PCC pit with precast RCC cover, charcoal/salt, funnel, CI frame etc complete. NOTES :-(i)The concrete pit shall be made in PCC 1:3:6 type C-1, using 12.5mm graded crushed stone aggregate 40mm thick precast cover slab of RCC (1:2:4), type B-1, using 20mm graded crushed stone aggregate with suitable MS handle in lieu of CI cover shown in electrical plate No 3 of MES SSR Part-I shall be provided. Reinforcement in RCC cover shall be of 8mm dia TMT bars laid @150mm c/c both ways (ii) Item includes the cost of 7.5 metre GI pipe for protection of earth strip. Any variation in length shall be measured and paid through deviation order. (iii) Item includes cost of 7.5 metre earth strips. Any variation in length shall be adjusted through deviation order. (iv) Earth plate electrode shall be surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides.
Supply , install, testing and commissioning of cubical housing cabinet type Out door LT panel of size 2000 mm x 1500 mm x 600 mm, platform mounted factory made, totally enclosed dust and vermin proof openable from both front and rear side made out of 3.15 mm thick CRCA (Cold Rolled Cold Annealed) MS Sheet, Powder coated, CPRI approved and built upon 50 x 50 x 6 mm size angle iron frame work , having front and rear hinged doors, lifting lugs (2 Nos) , earthing strips at rear side , bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts , spring and washers. The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment Necessary foundation work as required at site and comprising including dismantling of old unsv panel complete all as specified. BUS BAR- (a) Electrolytic grade high conductivity TP&N solid copper bus bars, rated 350 amps supported at required intervals sleeved with heat shrinkable PVC sleevings. The bars shall be colour coded at required intervals for identification - 04 Nos. INDICATING DEVICES-(a) LED Indicating lamps for Main Supply indicating R', Y' B' - 01 Set of 3 (b) Digital Voltmeter - 01 No (c)Current Transformer having Ratio 400/5, 15 VA - 01 Set of 3 (d) Digital Ammeter - 01 N0 CONTROLS- (a) Supply and fixing MCCB of 4 pole of capacity 200 amps, with breaking capacity of 36 KA with fixed thermal & fixed magnetic setting - 01 Nos (Incomming) (b) Supply and fixing MCCB of 4 pole of capacity 100 amps, with breaking capacity of 25 KA with fixed thermal & fixed magnetic setting - 02 Nos (Outgoing) (c) Supply and fixing MCCB of 4 pole of capacity 40 amps, with breaking capacity of 16 KA with fixed thermal & fixed magnetic setting - 02 Nos (Outgoing) (d) MCB, SPN, 32 Amps - 02 Nos (For 2 nos Parking Shead)
M & L for providing cement concrete 1:2:4 type B-1 using 20 mm graded stone aggegrate in copings to poles & the like etc including weathering,slightly rounded or chamfered angles and throating as complete all as specified and diected.
Supply, installation, testing and commissioning Aviation Light Integral LED aviation light with electronic ballast comprising of aluminium housing with polycarbonate enclosure (Bajaj Cat. No.BGAV302 LED)
Supply, Installation, testing and commissioning of High Mast 12 meter in two section, 3 mm section thickness, top dia 150 mm, bottom dia 340 mm suitable for 08 Nos LED Flood Light fittings, symetrically fitted along with their driver and having 2 point suspension system with stainless steel wire rope of 6 mm dia 97/19 guage and double drum winch with luminnaire mounting arm, pully assembly,twin red LED aviation obstruction light 2X6 watt , lightning arrestor spike including RCC shallow foundation as per manufacturer design based on soil bearing capacity with integral power tool installed inside base compartment for operation suitable for wind velocity as per IS 875 Part 3, including & confirming to the following Providing pedestal type RCC foundation as per soil conditions including excavation, RCC shuttering, centering, etc. complete as required. Connecter/Terminal set 16-50 sqmm 5 pole fitted inside the mast for cable connection. Note :(i) The installation fittings and accessories shall be gote done under the supervision of manufacturer and as per manufacturers instructions and approved by GE. (ii) PV and Test certificate for each and every item related to High mast system to be produced. (iii) Necessary approval must be taken regarding details technical specificatio and foundation drawing of high mast light before placing order to the company. (iv) Earthing shall be done for HM and FP Box and paid seperately.
Providing PCC (1 :4 : 8), type D2,using 40 mm graded crushed stone aggregate as in foundations, filling, mass concrete, bed of pipe etc complete
Supply and fix in replacement MCCB, 3 Pole, 100 Amps, with breaking capacity 16KA, Thermal magnetic trip Unit, fixed thermal Fixed magnetic (FTFM), Ics=100% Icu, AC 415 volt ,50 HZ complete all as specified and as directed.
Supply & Fix in replacement Factory made, distribution boards, sheet metal enclosure VTPN, 4 Ways, 415 Volts double door type, protection class (IP-43) suitable for mounting MCCBs DBs confirming to IS-13032, IS-8623, BS-5484 with min 200 Amps rating copper bus bar complete all as specified and as directed.
Test point terminal block made of copper size 300 mm x 32mm x 6mm, drilled and screwed including 3 Nos. 8 mm dia. screw hex. Head screw and MS cover made of 2mm thick sheet including provision for entry/exit of earth strip
Supply and fixing copper strip of size 20 x 3.15 mm with saddles with required porcelian insulator , fixing screws etc. for roof conductors and down conductors complete all as specified and directed.
S&F Triple pole and earth encolsure with a three pin and earth plug with socket complete with one triple pole MCB MCB of 63 amps complete all as specified and directed.
Taking down existing 60 KVA UPS in semuletor building akash missile after proper disconnecting of electric connection and shifting to FMS Building for re fixing commisning and testing as same complete all as specified and directed.
STANDARD ELECTRIC WINDERS (BID ID -3133407)
FREEZCON (BID ID -3134092)
M/S S. P. ENTERPRISE (BID ID -3133808)
D.D Construction (BID ID -3135988)
M/S MAHATO ENTERPRISE (BID ID -3137055)
M/s PRABIR ENTERPRISE (BID ID -3133174)
pintoo construction (BID ID -3135250)
M/s KL Agarwalla & Co (BID ID -3137077)
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .