14 conditions · 2 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or V whichever is less, where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderer shall submit requisite information as per Annexure-VIB of GCC, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
a. The tenderer must have successfully completed any of the following during last 07 [seven] years, ending last day of month previous to the one in which tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or One similar work each costing not less than the amount equal to 60% of advertised value of the tender.
Execution of Indoor work (hardware/software) of same make of EI as existing one. NOTE: The tenderer should be either existing EI's OEM or OEM authorized /supported. Tenderer shall submit an undertaking with either OEM or OEM authorized /supported agency for installation, testing and commissioning (including after sales support during the warranty period).
39 conditions · 9 needing a document upload
Submit your bank details i.e. Name of the Bank along with Bank Branch Code, Account Number, IFSC Code, and PAN Number.
As per Correction slip "The tenderers shall submit a copy of certificate stating that all their statements/documents submitted along with bid are true and factual. Standard format of certificate to be submitted by the bidder is enclosed as Annexure-V. In addition to Annexurc-V, in case of other than Company/Proprietor firm. Annexure -V(A) shall also be submitted by the each member of a Partnership Firm / Joint Venture (JV) / Hindu Undivided Family (HUH / Limited Liability Partnership (LLP) etc., as the case may be. Non submission of above certificate(s) by the bidder shall result in summarily rejection of his/their bid. It shall be mandatorily incumbent upon the tenderer to identify, state and submit the upporting documents duly self- attested/digitally signed by which they/he is qualifying the Qualifying Criteria mentioned in the Tender ocument. [Format available in Correction slip}.
In case the Tenderer is a Partnership Firm: [i] A notarized copy Partnership deed. [ii] A notarized or registered Power of Attorney (duly registered as per prevailing law) in favour of an individual to sign the tender documents and create liability against the Firm. [iii] PAN / TAN number of Partnership firm (PAN / TAN number in the name of any of the constituent partners shall not be considered).
In case the Tender is a HUF: (i) A copy of notarized affidavit on Stamp Paper declaring that he who is submitting the tender on behalf of HUF is in the position of 'Karta' of Hindu Undivided Family (HUF) and he has the authority, power and consent given by other members to act on behalf of HUF. and (iii) All other documents in terms of explanatory notes in clause 10 of IRGCC 2022.
In case the Tender is a Sole Proprietorship Firm: (i) All other documents in terms of explanatory notes in clause 10 of IRGCC 2022.
In case the Tenderer is a Company registered under Companies Act-2013:(i) The copies of MOA (Memorandum of Association) / AOA (Articles of Association) of the company. (ii) A copy of Certificate of Incorporation. (iii) A copy of Authorization/Power of Attorney issued by the Company (backed by the resolution of Board of Directors) in favour of the individual to sign the tender on behalf of the company and create liability against the company. and (iv) Copy of PAN number of the Company .
In case the Tenderer is a LLP Firm registered under LLP Act-2008 (i) a copy of LLP Agreement, (ii) a copy of Certificate of Incorporation. (iii) a copy of Power of Attorney/Authorisation issued by the LLP Firm in favour of the individual to sign the tender on behalf of the LLP Firm and create liability against the Firm. and (iv) copy of PAN number of the LLP Firm.
In case the Tenderer is a Registered Society & Registered Trust: (i) A copy of the Certificate of Registration. (ii) Deed of Formation. (iii) A copy of Power of Attorney in favour of the individual to sign the tender documents and create liability against the Society/Trust. (iv) copy of PAN number of the Society/Trust.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions. NormalApplicable to all biddersNoYesAllowed(Optional)Click here for Deletion.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
If the mandatory documents asked for in the E-Tender Document are not submitted along with the tender, the tender submitted otherwise will be treated as incomplete and will not be considered.
The quantities shown in above Schedule are approximate and are as a guide to give the tenderer(s) an idea of quantum of work involved. The Railway reserves the right to increase/ decrease and/or delete or include any of the quantities given above and
All rates quoted in the tender shall be deemed to be inclusive of all Taxes royalties payable by the contractor s to the Government or public body or local authority and no additional amount will be paid or claim entertained on this account by the Railway.
It is responsibility of the tenderer that they ensure to see any Corrigendum of the tender to check the corrigendum on the website from time to time.
The works are required to be completed within a period of 9 months as mentioned in website from
The Tenderer(s) shall keep the offer open for a minimum period of 60 days from the date of opening of the Tender. It is understood that the tender documents have been sold/issued to the Tenderer(s) and the Tenderer(s), is / are permitted to tender in consideration of the stipulation on his / their part that after submitting his / their tender subject to the period being extended further, if required by mutual agreement from time to time, he will not resale from his offer or modify the terms and conditions thereof in a manner not acceptable to the DRM/S&T/Divisional Engineer of SW Railway, Should the tenderer fail to observe or comply with the foregoing stipulation, the amount deposited as Earnest Money for the due performance of
If the tender is accepted, the amount of Earnest Money will be retained and adjusted as Security Deposit for the due and faithful fulfillment of the contract. This amount of Security Deposit shall be forfeited, if the Tenderer(s)/Contractor(s) fail to execute the Agreement Bond within 7 days after receipt of notice issued by Railway that such documents are ready or to commence the work within 15 days after recei
Rights of the Railway to Deal with Tender: The authority for the acceptance of the tender will rest with the Railway. It shall not be obligatory on the said authority to accept the lowest tender or any other tender and no Tenderer's(s) shall demand neither any explanation for the cause of rejection of his /their tender nor the Railway to assign reasons for declining to consider or reject any particular tender or tenders.
If the tenderer(s) expires after the submission of his / their tender or after the acceptance of his their tender, the Railway shall deem such tender cancelled. If a partner of a firm expires after the submission of their tender or after the acceptance of their tender, the Railway shall deem such tender as cancelled, unless the firm retains its character
No post tender correspondence will be permitted and the tender shall be decided based on the
The Tenderer's shall not add any conditions on their own in the tender documents while submitting their offer. Any such conditions if stated and if tender conditions are in violation of the Railway s, may lead to summary rejection of the offer. Railway reserves the right to reject such tenders summarily without assigning any reasons whatsoever
The responsibility of uploading the correct documents lies with the Tenderer's. In case, the documents uploaded are found manipulated/forged, the offers of such Tenderer's will not be considered and such Tenderer's are liable to be debarred to participate for future works duly forfeiting their Earnest Money and the tenderer/contractor shall have no claims whatsoever in this regard. Railway reserves the right to determine/rescind the contract entered into in case of such false certificates/documents at any stage of the contract treating it as default of the contractor
Tender Opening will be done any time after the tender closing time. Tenderers are not required to be present during the opening. Railway reserves right to open the tender any time after the time of closing of tender
Before submitting a tender, the tenderer will be deemed to have satisfied himself by actual inspection of the site and locality of the works, that all conditions liable to be encountered during the execution of the works are taken into account and that the rates he enters in the tender forms are adequate and all inclusive to accord with the provisions in Clause-37 of the Standard General Conditions of Contract for the
Tender Opening will be done any time after the tender closing time. Tenderers are not required to be present during the opening. Railway reserves right to open the tender any time after the time of closing of tender.
Before submitting a tender, the tenderer will be deemed to have satisfied himself by actual inspection of the site and locality of the works, that all conditions liable to be encountered during the execution of the works are taken into account and that the rates he enters in the tender forms are adequate and all inclusive to accord with the provisions in Clause-37 of the Standard General Conditions of Contract for the completion of works to the entire satisfaction of the Engineer.
Railways, being principal employer are required to ensure that the contractors are complying with the provisions of the contract labour (R&A) Act, 1970 and Minimum wages Act, 1948 strictly and arranging prescribed minimum wages to the contractor labourers vide Railway Board letter No. 2016/E(LL)/AT/MW/1Dt. 05.06.2017.
1.Provision of shunting neck on Rd-4 for a length of 300m towards SLU end in JRU yard. 2. Signalling estimate for provision of trip shed at JRU station 3. Shunting Neck of 750m towards DRU end by extending the existing siding on Road-4 at Birur (RRB) station.
03-SNT-MYS-2026-01
03-SNT-MYS-2026-01
Open
Works - General
9 Months
Dharwad, Karnataka
₹0
₹5.3 L
10 Jun 2026
18 May 2026
27 May 2026
517 items across 11 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 53,74,630 | ||
| — | — | — | Above/ 47045.00 Below/P | ||
| Chapter-1: Supply of Signal aspect - LED Signal Lighting Unit Red with current regulator, as per RDSO specification No. RDSO/SPN/199/2010 revision 1.1 or latest. | — | 5.00 | — | — | |
| — | — | — | Above/ 49230.00 Below/P | ||
| Chapter-1: Supply of Signal aspect - LED Signal Lighting Unit Yellow with current regulator, as per RDSO specification No. RDSO/SPN/199/2010 revision 1.1 or latest. | — | 5.00 | — | — | |
| — | — | — | Above/ 53685.00 Below/P | ||
| Chapter-1: Supply of Signal aspect - LED Signal Lighting Unit Green with current regulator, as per RDSO specification No. RDSO/SPN/199/2010 revision 1.1 or latest. | — | 5.00 | — | — | |
| — | — | — | Above/ 144720.00 Below/P | ||
| Chapter-1: Supply of Signal aspect -Shunt LED Signal Lighting Unit with current regulator, as per RDSO specification No. RDSO/SPN/153/2011 Rev 4.1 or latest. | — | 20.00 | — | — | |
| — | — | — | Above/ 17100.00 Below/P | ||
| Chapter-1: Supply of Ground type shunt signal - complete with surface base, signal pole, hood etc., as per latest specification. | — | 2.00 | — | — | |
| — | — | — | Above/ 5727.00 Below/P | ||
| Chapter-1: Excavation of pit and casting concrete foundation as per Drg, No.SG/SWR/053 using metallic templates, for erection of Ground type colour light Shunt Signal. [Foundation bolts and nuts, cement, river sand, stone jelly of size 20/25mm and all other miscellaneous materials for the work shall be supplied by the Contractor]. | — | 1.00 | — | — | |
| — | — | — | Above/ 4768.00 Below/P | ||
| Chapter-1: Erection of Ground type shunt signal complete including surface base, signal pole, LED aspects/ lenses, bulbs with holders (whichever is applicable), fixing of lens guards, number plate, termination of tail cables, wiring of signal unit with PVC wire 3/0.75mm copper, provision of EWS locks and painting of one coat of red oxide and two coats of Aluminium/ enamel paint. (Supply of Ground type shunt signal complete including surface base, signal pole, LED aspects, holder, bulbs, and lenses is not covered in this item). [Wire PVC 3/0.75mm copper, lens guards, EWS locks, Enameled number plates, bolts and nuts, lead wool, paints and all other miscellaneous materials shall be supplied by the Contractor]. | — | 1.00 | — | — | |
| — | — | — | Above/ 3504.00 Below/P | ||
| Chapter-1: Manufacturing, Supply, painting and fixing of markers of G/P/C/A/IB Markers/Number plates as per IRSEM DRG.No 19-D10 on MS sheet of thickness 3mm. Miscellaneous materials required for fixing is to be supplied by contractor. | — | 6.00 | — | — | |
| — | — | — | Above/ 3630.00 Below/P | ||
| Chapter-1: Dismantling and releasing of Existing Colour light Signals complete (upto 4 aspects) with or without Route Indicators, calling on signals, shunt signals etc., carefully without any damage to the gadgets, accounting and stacking them neatly at a place as instructed by Railway representative at site. The work includes breaking the concrete foundation, closing the resultant pit and resurfacing it by ramming and levelling. | — | 1.00 | — | — | |
| — | — | — | Above/ 145488.00 Below/P | ||
| Chapter-2: Supply of apparatus cases Full size as per latest specification/drawing. | — | 6.00 | — | — | |
| — | — | — | Above/ 34640.00 Below/P | ||
| Chapter-2: Supply of apparatus cases Half size as per latest specification/ drawing. | — | 2.00 | — | — | |
| — | — | — | Above/ 92000.00 Below/P | ||
| Chapter-2: Supply of PBT terminals 25mm centre, as per RDSO Specification No. IRS.S.75/2006 (Rev.2) or latest | — | 1000.00 | — | — | |
| — | — | — | Above/ 5600.00 Below/P | ||
| Chapter-2: Supply of PBT terminals 60mm centre as per RDSO Specification No. IRS.S.75/2006 (Rev.2) or latest. | — | 50.00 | — | — | |
| — | — | — | Above/ 7650.00 Below/P | ||
| Chapter-2: Supply of 60mm center PBT Fuse blocks as per RDSO Specification No. IRS.S.75/2006 (Rev.2) or latest. | — | 50.00 | — | — | |
| — | — | — | Above/ 9030.00 Below/P | ||
| Chapter-2: Supply of 'E' type locks of different wards as per requirement with key per E- type lock to Drg. No. SA.3376IM/Latest and RDSO Specn. No. IRS. S.30/64. Rev.0. | — | 10.00 | — | — | |
| — | — | — | Above/ 108890.00 Below/P | ||
| Chapter-2: Excavation of pit, casting concrete foundation and erection of Apparatus Case Full size as per Drg. No. SG/SWR/055 and fixing of 2 nos of "E" type locks, one for the front door and another for the back door, fixing of one hard wood shelf plank 37mm thick and painting the apparatus case inside and outside with one coat of red oxide and two coats of aluminium paints, along with painting of termination and equipment particulars on the doors of apparatus cases as per instructions of railway representative at site. (Supply of apparatus case is not included in this item). [ Foundation bolts & nuts, 'E' type locks, cement, river sand, stone jelly of size 20/25mm, hardwood plank of 37mm thick, paints, varnish, fixing bolts & nuts and all other miscellaneous materials required for the work shall be supplied by the contractor]. | — | 5.00 | — | — | |
| — | — | — | Above/ 30726.00 Below/P | ||
| Chapter-2: Excavation of pit, casting concrete foundation and erection of Apparatus Case Half size as per Drg, No.SG/SWR/056, fixing one 'E' type lock for the front door and latching arrangement for the back door, and fixing of one hardwood shelf plank 37mm thick and painting the apparatus case inside and outside with one coat of red-oxide and two coats of aluminium paints. (Supply of apparatus case is not included in this item). [Foundation bolts and nuts, cement, 'E' type locks, river sand, stone jelly of size 20/25mm, 37mm hard wood planks, latching arrangements, paints, varnish, fixing bolts & nuts and all other miscellaneous materials required for the work shall be supplied by the Contractor] | — | 2.00 | — | — | |
| — | — | — | Above/ 102500.00 Below/P | ||
| Chapter-2: Termination of main, tail, signalling and power cables on25/60mm PBT terminals on phenolic sheet and internal wiring on terminal in new apparatus cases, cable termination boxes and in gate lodges excluding cable termination rack at relay room. The work includes fixing of all new cables by teakwood clamp on teakwood base plank, fixing of phenolic synthetic industrial fiber base fine waves cotton fiber board 6mm thick for terminal board to suit each apparatus case, varnishing all teakwood items, fixing of terminals/ fuse blocks on the terminal board, drilling of necessary holes, termination of cables, wiring, identification of cables using aluminium tags with letters punched neatly, as per approved circuit diagram and cable plan painting of particulars on sleeves and also on the inner side of the doors of apparatus case. After terminations are over, the side openings of apparatus case foundation shall be closed with brick work, cement plastered, the inter space filled with sand up to base level and the bottom surface shall be sealed with sealing compound. (Supply of PBT terminals and fuse blocks is not covered in this item). { cement, teakwood cable clamp 50mmX 50mm, base planks 100mm x 25mm, phenolic synthetic industrial fiber base fine weave cotton fiber sheet - 6mm thick to IS specification 2036 -1995 - type F5, PVC / Nylon sleeves , varnish, paints, bolts, nuts, and washers, non-deteriorating type of fuses of various capacities, Aluminium cable tags, sealing compound, country bricks 220mm X 100mm X 60mm, copper bus bars, brass screw, river sand, wire PVC 3/0.75mm copper and other miscellaneous materials shall be supplied by the contractor) | — | 500.00 | — | — | |
| — | — | — | Above/ 7500.00 Below/P | ||
| Chapter-2: Termination of main, tail, signalling and power cables on PBT fuse block on phenolic sheet and internal wiring on fuse blocks in new apparatus cases, cable termination boxes and in gate lodges excluding cable termination rack at relay room. The work includes fixing of all new cables by teakwood clamp on teakwood base plank, fixing of phenolic synthetic industrial fiber base fine waves cotton fiber board 6mm thick for terminal board to suit each apparatus case, varnishing all teakwood items, fixing of terminals/ fuse blocks on the terminal board, drilling of necessary holes, termination of cables, wiring, identification of cables using aluminium tags with letters punched neatly, as per approved circuit diagram and cable plan painting of particulars on sleeves and also on the inner side of the doors of apparatus case. After terminations are over, the side openings of apparatus case foundation shall be closed with brick work, cement plastered, the inter space filled with sand up to base level and the bottom surface shall be sealed with sealing compound. (Supply of PBT terminals and fuse blocks is not covered in this item). ( cement, teakwood cable clamp 50mmX 50mm, base planks 100mm x 25mm, phenolic synthetic industrial fiber base fine weave cotton fiber sheet - 6mm thick to IS specification 2036 -1995 - type F5, PVC / Nylon sleeves , varnish, paints, bolts, nuts, and washers, non-deteriorating type of fuses of various capacities, Aluminium cable tags, sealing compound, country bricks 220mm X 100mm X 60mm, copper bus bars, brass screw, sand, wire PVC 3/0.75mm copper and other miscellaneous materials shall be supplied by the contractor) | — | 30.00 | — | — | |
| — | — | — | Above/ 34600.00 Below/P | ||
| Chapter-2: Termination of main, tail, Signaling and power cables of Cables on 25/60mm PBT terminals and internal wiring by fixing additional terminals on the Existing terminal boards of apparatus cases, cable termination boxes etc. The work includes fixing of all new cables by teakwood clamp on teakwood base plank, varnishing all teakwood items, fixing of terminals/ fuse blocks, on the existing terminal boards, drilling of necessary holes, termination of cables, wiring, identification of cables using aluminium tags with letters punched neatly, as per approved circuit diagram and cable plan, painting of particulars on sleeves and also on the inner side of the doors of apparatus cases. After terminations are over, the side openings of apparatus case foundation shall be closed with brick work, cement plastered, the inter-space filled with sand up to base level and the bottom surface shall be sealed with sealing compound. (Supply of PBT terminals and Fuse blocks is not covered in this item). [Cement, teakwood cable clamp 50mm x 50mm, base planks 100mm x 25mm, PVC/Nylon sleeves, varnish, paints, bolts, nuts and washers, Non-deteriorating type of fuses of various capacities, Aluminium cable tags, sealing compound, country bricks 220mm x 100mm x 60mm, copper bus bars, brass screw, sand, wire PVC3/0.75mm copper and other miscellaneous materials shall be supplied by the Contractor]. | — | 200.00 | — | — | |
| — | — | — | Above/ 4320.00 Below/P | ||
| Chapter-2: "Termination of main, tail, Signaling and power cables of Cables on PBT fuse block and internal wiring by fixing additional fuse blocks on the Existing terminal boards of apparatus cases, cable termination boxes etc. The work includes fixing of all new cables by teakwood clamp on teakwood base plank, varnishing all teakwood items, fixing of terminals/ fuse blocks, on the existing terminal boards, drilling of necessary holes, termination of cables, wiring, identification of cables using aluminium tags with letters punched neatly, as per approved circuit diagram and cable plan, painting of particulars on sleeves and also on the inner side of the doors of apparatus cases. After terminations are over, the side openings of apparatus case foundation shall be closed with brick work, cement plastered, the inter-space filled with sand up to base level and the bottom surface shall be sealed with sealing compound. (Supply of PBT terminals and Fuse blocks is not covered in this item). [Cement, teakwood cable clamp 50mm x 50mm, base planks 100mm x 25mm, PVC/Nylon sleeves, varnish, paints, bolts, nuts and washers, Non-deteriorating type of fuses of various capacities, Aluminium cable tags, sealing compound, country bricks 220mm x 100mm x 60mm, copper bus bars, brass screw, sand, wire PVC3/0.75mm copper and other miscellaneous materials shall be supplied by the Contractor]." | — | 20.00 | — | — | |
| — | — | — | Above/ 11698.00 Below/P | ||
| Chapter-2: Manufacture and Supply of M.S. Relay Frames of suitable size to Hold up to 4 relays /plug in type HMU as required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit and Point control circuits, fixing of plug boards, relays, resistors and electrolytic condensers on phenolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, wiring and termination as per approved circuit diagram and painting the particulars. (Supply of all types of relays, plug boards, connectors, retaining clips and plug in type HMU is not covered in this item). [Wire PVC copper, 3/0.75mm and 16/0.2mm copper, phenolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, for fixing resistors and condensers, MS flats 25mm x 6mm brass bolts and nuts, paints, soldering materials, resistors, condensers and all other miscellaneous materials required for the work shall be supplied by the contractor]. | — | 2.00 | — | — | |
| — | — | — | Above/ 14908.00 Below/P | ||
| Chapter-2: Manufacture and Supply of M.S. Relay Frames of suitable size to Hold up to 20 relays /plug in type HMU as required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit and Point control circuits, fixing of plug boards, relays, resistors and electrolytic condensers on phenolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, wiring and termination as per approved circuit diagram and painting the particulars. (Supply of all types of relays, plug boards, connectors, retaining clips and plug in type HMU is not covered in this item ). [Wire PVC copper, 3/0.75mm and 16/0.2mm copper, phenolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, for fixing resistors and condensers, MS flats 25mm x 6mm brass bolts and nuts, paints, soldering materials, resistors, condensers and all other miscellaneous materials required for the work shall be supplied by the contractor]. | — | 1.00 | — | — | |
| — | — | — | Above/ 75870.00 Below/P | ||
| Chapter-2: Painting of existing apparatus case - Full size without disturbing the terminations and equipments inside. The work involves scraping of old paint, applying one coat of Red oxide and two coats of Aluminium paint on the inside and outside the apparatus cases, and painting of termination and equipment particulars on the doors of the apparatus cases, as instructed by Railway representative at site. [Aluminium paint, red-oxide and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | — | 30.00 | — | — | |
| — | — | — | Above/ 24190.00 Below/P | ||
| Chapter-2: Painting of existing apparatus case - Half size without disturbing the terminations and equipments inside. The work involves scraping of old paint, applying one coat of Red oxide and two coats of Aluminium paint on the inside and outside the apparatus cases, and painting of termination and equipment particulars on the doors of the apparatus cases, as instructed by Railway representative at site. [Aluminium paint, red-oxide and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | — | 10.00 | — | — | |
| — | — | — | Above/ 4288.00 Below/P | ||
| Chapter-2: Breaking of concrete and releasing the existing Cable termination boxes, after releasing the base plank, Terminal blocks, Fuse Blocks, Terminal Boards, cut rails, pipes, etc., closing the resultant pits and consolidating it by ramming and levelling. The released materials shall be accounted and stacked neatly at a place as instructed by Railway representative at site. | — | 2.00 | — | — | |
| — | — | — | Above/ 8730.00 Below/P | ||
| Chapter-2: Alterations to painted termination/ wiring particulars of functions in the Existing apparatus cases-Full Size, cable termination boxes, etc., on the PVC/ nylon sleeves and painting of new nomenclature on the existing signaling gadgets. This work includes carrying out alterations of particulars on the inner side of the doors of apparatus cases, re-numbering of apparatus cases and cable termination boxes. [Paints and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | — | 5.00 | — | — | |
| — | — | — | Above/ 1832.00 Below/P | ||
| Chapter-2: Alterations to painted termination/ wiring particulars of functions in the Existing apparatus cases- Half Size, cable termination boxes, etc., on the PVC/ nylon sleeves and painting of new nomenclature on the existing signaling gadgets. This work includes carrying out alterations of particulars on the inner side of the doors of apparatus cases, re-numbering of apparatus cases and cable termination boxes. [Paints and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | — | 2.00 | — | — | |
| — | — | — | Above/ 3434.00 Below/P | ||
| Chapter-2: Releasing of existing apparatus cases (Full/ Half/ Quartersize) without damage after releasing the shelf planks, Terminal blocks, Fuse Blocks, Terminal Boards, Relays of all types EKTs, Secondary Cells, power equipment's, 'E' type locks, etc., and breaking the concrete foundation. After releasing, the resultant pits are to be closed and consolidated by ramming and levelling. The released materials shall be accounted and stacked at a place as instructed by Railway representative at site. | — | 1.00 | — | — | |
| — | — | — | Above/ 11678.00 Below/P | ||
| Chapter-2: Fencing for location box duly providing foundation (a pit of size 400mm x 400mm x 1000mm is to be dig and cement concrete foundation in the pit in the ratio 1:3:6 to be casted) and fixing the frames/doors and E- type lock to the fencing with supplied material. The rail post/angular is to be erected up right in the foundation. All materials are to be arranged and used by the contractor (Rail post / angular /frames /Fencing/ E type locks will be supplied by railway). Cutting of rail post / angular / fencing to the required length, transportation to the site is to be done by the contractor. | — | 2.00 | — | — | |
| — | — | — | Above/ 61724.00 Below/P | ||
| Chapter-2: Supply of cable termination box (FRP type) with necessary inspection as per latest specification/ drawing. | — | 4.00 | — | — | |
| — | — | — | Above/ 9350.00 Below/P | ||
| Chapter-2: Supply of Universal locks with one key for every ten locks. | — | 50.00 | — | — | |
| — | — | — | Above/ 107575.00 Below/P | ||
| Chapter-3: Supply of Electric Point Machine - IRS type 143 mm throw with Lock and detector Slides, Cable termination box with suitable ground connections, Insulation's etc. confirming to RDSO Specification no IRS:S24-2025 Revision 3.0 or latest | — | 1.00 | — | — | |
| — | — | — | Above/ 7620.00 Below/P | ||
| Chapter-3: Supply of insulations for 'D' clamp switch extension bracket to suit to universal point machine as per RDSO Drawing supplied by the Railways. (One set consists of 'D' clamp insulation - 2 No. Nylon insulation bushes 4 No., Nylon insulation washers - 8 No.) | — | 10.00 | — | — | |
| — | — | — | Above/ 18020.00 Below/P | ||
| Chapter-3: Installation of point machine - IRS type 143 mm and connecting all ground connections including wiring and termination in point machine and inter connections between point machine and CT box through PVC hose pipe with 3/0.75mm and 7/1.40mm copper wire and painting. This work includes provision of insulation to stretcher bars, throw bar lug and "D" bracket wherever required, cutting of notches on the point machines covers to suit crank handle configuration. (Combined type point machine with ground connection, uninsulated stretcher bar, throw bar lug and 'D' brackets will be supplied by Railways. [All types of insulations connected to point work, all type of bolts and nuts, washers spring/flat wire PVC 7/1.4mm copper, PVC hope pipe, paints, PVC/nylon sleeves and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | — | 1.00 | — | — | |
| — | — | — | Above/ 24812.00 Below/P | ||
| Chapter-3: Installation, termination of cable in termination box, wiring, testing and commissioning of IRS High Thrust point Machine 220mm.This includes fixing of point machine on MS plate fixed on sleepers complete with fixing of anti-theft covers, MS termination boxes, ground connections, required insulation, crank handle ward (wherever required) etc. This also include necessary adjustment and smithy work, drilling of holes on tongue rails, supply of all miscellaneous material such as flat, angle, bolt, nuts, pins etc. | — | 1.00 | — | — | |
| — | — | — | Above/ 448.00 Below/P | ||
| Chapter-3: Supply of Insulation for 'L' type bracket for point fitting IRS type as per drg. No. SA-8800-01(Adv.) or latest complete consisting of insulation rail joint splice plate - 01No. to drg. no. S-8804 Nylon Type-66 as per IRS-S-40/84 with latest amendment, Ferule -02 Nos. to drg. no. S-8813 as per specn.no.IRS:S-40/84 material nylon type-66, washer - 04 Nos. to RDSO drg.no. T- 10371ALT-2 IRS-40/84 nylon type-66. | — | 4.00 | — | — | |
| — | — | — | Above/ 28700.00 Below/P | ||
| Chapter-4: Supply of Track Feed Battery charger, 110V AC as per latest specification No. IRS :S-89-2013 ver 1.0 or latest. Charger shall be of 10Amp output capacity suitable for charging 80AH battery and No. of Lead acid cells, 2/3/4. | — | 5.00 | — | — | |
| — | — | — | Above/ 18100.00 Below/P | ||
| Chapter-4: Supply of B Type choke, confirming to RDSO specification No.IRS:S 65:83 version 1.0 or latest specification. | — | 5.00 | — | — | |
| — | — | — | Above/ 2175.00 Below/P | ||
| Chapter-4: Supply of Track feed regulating resistance disk type 0 to 30 ohms as per Drg.No.SA.20161/06/M or latest. | — | 5.00 | — | — | |
| — | — | — | Above/ 145460.00 Below/P | ||
| Chapter-4: Supply of Track lead junction box - FRP type with 4 terminals and stumps with necessary inspection as per latest specification/drawing. | — | 70.00 | — | — | |
| — | — | — | Above/ 2500.00 Below/P | ||
| Chapter-4: Supply of UL standard PPTC fuses complies to UL Thermistor standard 1434 with rating -2 Amps. | — | 50.00 | — | — | |
| — | — | — | Above/ 17992.00 Below/P | ||
| Chapter-4: Provision of DC Single/ Double rail track circuiting Point zone to suit RE/Non-RE areas as per approved signaling plan using Plug-in type track relays. This work includes provision of double bonding, and parallel jumpers, provision of bond wire clips, provision of track lead connections using 2c X 2.5 sq.mm cable, provision of TLJB boxes 2 Nos. at Relay end, 2 Nos. at Feed end and 2 Nos for parallel jumpers as necessary to suit layouts, for each Track Circuit, and termination of jumpers and tail cables in track lead junction boxes, installation of relays, track feed battery chargers to charge up to 4 cells, track feed resistance, B type choke and secondary cells - 80 AH capacity in apparatus cases and wiring with wire PVC 3/0.75mm copper. The work also includes painting of track Circuit No. with Feed end/ Relay end details on the TLJB boxes. The work also includes provision of insulations for gauge tie plates and nose crossing plates wherever required. (Provision of rail joint insulation is not covered in this item) (Uninsulated gauge type plate and nose crossing plate will be supplied by Railways. Supply of track feed battery charger, B type choke, track relays, uncharged secondary cells (2V - 80AH), TLJB boxes with stumps, 2cX2.5 sq.mm cable, is not covered in this item). [track feed resistance, Gauge tie plate and nose crossing plate insulations, PVC/Nylon bushes for TLJB boxes, PVC sleeves, all types of fixing bolts and nuts with spring and flat washers, teakwood stand for fixing track feed resistance, GI bond wire 8 SWG, Channel bond pins, bond wire clips, paints and all other miscellaneous materials shall be supplied by the contractor. Secondary cells-80 AH capacity shall be charged by the contractor through reputed charging agencies]. | — | 2.00 | — | — | |
| — | — | — | Above/ 4702.00 Below/P | ||
| Chapter-4: Alteration to existing track circuits at Feed end to suit RE/Non-RE standard as per approved signalling plan. This work includes provision of double bonding and parallel jumpers, provision of bond wire clips, wherever required, shifting of relay end and feed end equipments and re-wiring them, provision of track lead connections wherever necessary using 2c x 2.5 sqmm cable, provision of TLJB boxes and termination of jumpers and tail cables in track lead junction boxes, shifting of Track feed/Track relay set wherever required and wiring with PVC 3/0.75mm copper wire. (Supply of TLJB boxes, 2c x 2.5 sq.mm cable and TLJB boxes with stumps is not covered in the item. Existing Track relays, Track Feed Resistance, Track feed battery chargers, B type Chokes and Charged secondary Cells shall use for this work). [Wire PVC 3/0.75mm, PVC/ Nylon bushes for TLJB boxes, PVC sleeves, all types of bolts and nuts with spring and flat washers, teakwood stand for fixing track feed resistance, GI bond wire 8 SWG, Channel bond pins, bond wire clips, paints and all other miscellaneous materials shall be supplied by the Contractor]. | — | 1.00 | — | — | |
| — | — | — | Above/ 4341.00 Below/P | ||
| Chapter-4: Alteration to existing track circuits at Relay end to suit RE/Non-RE standard as per approved signalling plan. This work includes provision of double bonding and parallel jumpers, provision of bond wire clips, wherever required, shifting of relay end and feed end equipments and re-wiring them, provision of track lead connections wherever necessary using 2c x 2.5 sqmm cable, provision of TLJB boxes and termination of jumpers and tail cables in track lead junction boxes, shifting of Track feed/Track relay set wherever required and wiring with PVC 3/0.75mm copper wire. (Supply of TLJB boxes, 2c x 2.5 sq.mm cable and TLJB boxes with stumps is not covered in the item. Existing Track relays, Track Feed Resistance, Track feed battery chargers, B type Chokes and Charged secondary Cells shall use for this work). [Wire PVC 3/0.75mm, PVC/ Nylon bushes for TLJB boxes, PVC sleeves, all types of bolts and nuts with spring and flat washers, teakwood stand for fixing track feed resistance, GI bond wire 8 SWG, Channel bond pins, bond wire clips, paints and all other miscellaneous materials shall be supplied by the Contractor]. | — | 1.00 | — | — | |
| — | — | — | Above/ 314.00 Below/P | ||
| Chapter-4: Releasing of existing TLJB boxes with stumps and terminals after releasing all the bond wires. The released materials shall be accounted and stacked neatly at a place as instructed by Railway representative at site. | — | 2.00 | — | — | |
| — | — | — | Above/ 152000.00 Below/P | ||
| Chapter-6: Excavation of cable trench in all kinds of soil except hard rocky areas including clearing of roots of trees, rocks, bushes etc. to a depth of 1.0 Mtrs and to a width of 0.3 Mtrs. (Laying of cables is not included in this item). | — | 2000.00 | — | — | |
| — | — | — | Above/ 45908.00 Below/P | ||
| Chapter-6: Supply and Laying of PVC Warning Tape colour Orange, width of 250mm (10") by printing with black letters 'Indian Railway Signal/Telecom/OF Cable' on both sides | — | 1.00 | — | — | |
| — | — | — | Above/ 36000.00 Below/P | ||
| Chapter-6: Refilling of cable trench 1m depth by 0.3m width throughout, with earth after laying of cables, and consolidating the trench by ramming and levelling. | — | 2000.00 | — | — | |
| — | — | — | Above/ 228900.00 Below/P | ||
| Chapter-6: Supply of High-Density Polyethylene Pipes (HDPE) of 110 mm Outer Dia, 10 mm Wall Thickness, along with one coupler for every 6 Meters as per latest specification No. IS 4984: 2016 with latest amendments and Material Grade: PE 80. | — | 300.00 | — | — | |
| — | — | — | Above/ 20700.00 Below/P | ||
| Chapter-6: Laying of HDPE Pipe 110 mm outer Dia, 10mm thickness along with collars in trenches at places of platform cutting etc and wherever required as per the instruction of site engineer. | — | 300.00 | — | — | |
| — | — | — | Above/ 124800.00 Below/P | ||
| Chapter-6: Concreting of cable laid in the trench or GI pipe/DWC/HDPE pipe in which cable is already laid to a size of 300x300mm with 1:3:6 mortar. (All the materials required for the work should be supplied by the contractor). | — | 200.00 | — | — | |
| — | — | — | Above/ 168000.00 Below/P | ||
| Chapter-6: Laying of Signaling/Power/Telecommunication cables as per cable plan in cable trenches, masonry ducts, RCC Pipes, DWC pipes, GI Pipes etc. (Supply of cables is not included in this item). | — | 8000.00 | — | — | |
| — | — | — | Above/ 20790.00 Below/P | ||
| Chapter-6: Supply of GI pipes - 50mm dia -3.65mm thick as per latest specification. | — | 30.00 | — | — | |
| — | — | — | Above/ 99120.00 Below/P | ||
| Chapter-6: Supply of GI pipes - 100mm dia-4.5mm thick as per latest specification. | — | 60.00 | — | — | |
| — | — | — | Above/ 336510.00 Below/P | ||
| Chapter-6: Supply of DWC pipe of 180 mm outer dia/ 153 mm inner dia in lengths of 6 Mtr with coupler. to IS specification No.14930 Part- II or latest. The IS spec shall be marked on the pipe. | — | 90.00 | — | — | |
| — | — | — | Above/ 207600.00 Below/P | ||
| Chapter-6: Supply and laying of Split DWC pipe of 120/103 mm dia, 2 meter long in already dug cable trenches. The unit of RMT means two split pipes of 1 Mtr each Material shall be supplied as per latest specification RDSO/SPN/204/2011 Ver.1.1 or latest. | — | 600.00 | — | — | |
| — | — | — | Above/ 11520.00 Below/P | ||
| Chapter-6: Provision of GI pipes (50/100/150mm dia) for cable laying with offset at both ends and with couplings over RCC Bridges/ Drainage/ Culverts with concrete masonry supports of size 300mm x 300 mm x 300 mm at an interval of 2m. The ends of the pipes shall be closed with brick masonry abutments work so that no cable is exposed, the work shall be carried out as per the instructions of Railway representative at site. (Supply of GI pipes with couplings and laying of cables is not included in this item). [Stone jelly of size 20/25mm, bricks, sand, cement and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | — | 30.00 | — | — | |
| — | — | — | Above/ 30150.00 Below/P | ||
| Chapter-6: Provision of GI pipes (50/100/150mm dia) for cable laying in Hard rocky area with off sets at both ends duly supported by concrete blocks of size 300mm x 300 mm x 300 mm at an interval of 2m. The ends of the pipes shall be closed with brick masonry abutments work so that no cable is exposed, The work shall be carried out as per the instructions of Railway representative at site. (Supply of GI pipes with couplings and laying of cables is not included in this item). [Stone jelly of size 20/25mm, bricks, sand, cement and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | — | 90.00 | — | — | |
| — | — | — | Above/ 153100.00 Below/P | ||
| Chapter-6: Horizontal direction drilling/boring without damage of surface road/track using Auger Machine (HDD machine). The bore shall be upto 200 mm dia& shall be done at the depth of minimum 1200 mm from the ground level. The ground level shall be considered ignoring the bank height of the bank of the road. The length of the bore shall be minimum 4 Mtrs long. This includes insertion of different dia DWC-HDPE pipe/GI pipes coupling etc. as per direction of Engineer Incharge. Note:- Pipe Supply is not covered under this item. Contactor shall provide all material required for boring and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable. | — | 100.00 | — | — | |
| — | — | — | Above/ 45900.00 Below/P | ||
| Chapter-6: Excavation of trench to a depth of 1 Mtr. for track crossing of cables, laying of DWC/HDPE/RCC pipes with collar/coupling, refilling of trench by ramming and consolidating it as per the instructions of Railway representative at site. During excavation of trench, it has to be ensured that the excavated soil does not mix with the ballast available. The depth of 1m trench shall be from the bottom of sleepers for track crossings. Laying of cables is not included in this item. (Supply of DWC/HDPE/RCC pipes with couplers/ collars is not included in this item). | — | 100.00 | — | — | |
| — | — | — | Above/ 59700.00 Below/P | ||
| Chapter-6: Excavation of trench to a depth of 1 Mtr. for road crossing of cables, laying of DWC/HDPE/RCC pipes with collar/ coupling, refilling of trench by ramming and consolidating it and resurfacing it to the original position. Laying of cables is not included in this item. (Supply of DWC/HDPE/RCC pipes with couplers/ collars is not included in this item). | — | 100.00 | — | — | |
| — | — | — | Above/ 42450.00 Below/P | ||
| Chapter-6: Provision of 2 Machine cut grooves in parallel at a separation of 8 cms each to a depth of 150 mm and width will be as per site requirement in the platform surfaced/tiled floor for laying cable | — | 50.00 | — | — | |
| — | — | — | Above/ 36600.00 Below/P | ||
| Chapter-6: Supply of RCC Cable Markers as per DRG.No.SG/SWR/067 or latest guidelines. The lettering on the Cable marker shall be "SIG" / "TELE" / "OFC" as per the instructions of Railway representative at site. | — | 100.00 | — | — | |
| — | — | — | Above/ 26700.00 Below/P | ||
| Chapter-6: Digging of pit to a depth of 800mm of size 300mmX300mm, casting of Concrete foundation of size 300mmX300mmX300mm and Placing of RCC cable markers on top of the foundation and refilling the pit and consolidating it by ramming. The cable markers shall be provided at an interval of 20 Mtrs. within station limits and 50 Mtrs. outside station limits throughout the cable route, diversions and also at every track/road crossing. | — | 100.00 | — | — | |
| — | — | — | Above/ 11310.00 Below/P | ||
| Chapter-6: Excavation of cable coil pit to a size of 1.5mx1.5m and depth as instructed by Railway representative at site, for coiling the cables in rear of relay rooms/ AFTC huts, apparatus cases etc. The work includes coiling the underground cables, and placing closely one layer of country bricks of size approx. 220mm x 100mm x 60mm breadth wise above the cables to cover all the cables in the cable pit, closing and consolidating the pit by ramming and levelling. [Country bricks of size 220mmx100mmx60mm (approximately) shall be supplied by the Contractor]. | — | 10.00 | — | — | |
| — | — | — | Above/ 6968.00 Below/P | ||
| Chapter-6: Video recording of cable trench using minimum 720P and above HD camera and submit one copy in New removable hard disks (With capacity as per requirement); Two copies in DVD-R. | — | 2.00 | — | — | |
| — | — | — | Above/ 1020.00 Below/P | ||
| Chapter-6: Cable armours soldering and earthing as instructed by incharge SSE/JE at site. [Per Unit = Per Cable] | — | 30.00 | — | — | |
| — | — | — | Above/ 13142.00 Below/P | ||
| Chapter-6: Excavation of pit, erection of cable termination boxes on rails and concreting as per Drg. No.SG/CN/02/8, drilling of suitable holes in the box, fixing of 2 Nos. of GI pipes 32mm dia and 300mm long at the bottom with clamp nuts - 12 mm thick, one at the inner side and another at the outer side for each pipe for cable entry and one GI pipe 150mm long 32mm dia for drawal of jumper wires for Point machines etc., fixing of hardwood plank 37mm thick on the bottom, provision of one EWS lock, and painting the boxes inside and outside with one coat of red-oxide and two coats of aluminium paints. (Supply of CT boxes is not covered in this item. Rails of different length shall be supplied by Railways. The contractor shall cut lengthy rails wherever required.) [Cement, sand, stone jelly of size 20/25mm, paint, varnish, GI Pipes 32mm dia - 300mm long - 2 No's and 150mm long - 1 No., clamp nuts - 12mm thick - 2 Nos. for each pipe, fixing bolts and nuts with washers, EWS locks, paints and all other miscellaneous materials shall be supplied by the Contractor]. | — | 2.00 | — | — | |
| — | — | — | Above/ 20200.00 Below/P | ||
| Chapter-8: Termination of Main, Tail, Signalling and power cables and internal wiring on terminal/ fuse blocks in cable termination Rack at relay room. The work includes fixing of all new cables by teakwood clamp on teakwood base plank, fixing of Hylam sheet 10 mm thick for terminal board, varnishing all teakwood items, fixing of terminals/ fuse blocks on the terminal board, drilling of necessary holes, termination of cables, wiring, identification of cables using aluminium tags with letters punched neatly, as per approved circuit diagram and cable plan, painting of particulars on sleeves. After terminations are over, cable entry at the bottom shall be closed with, cement plastered, the inter-space filled with sand up to base level and the bottom surface shall be sealed with sealing compound. Cable armour to be soldered to earth. (Supply of cable termination racks is not included in this item). [All bolts and nuts with washers, Hylam Sheet 10 mm Thick, cement, sand, stone jelly, Teak wood base, paints and all other miscellaneous materials required for the work shall be supplied by Contractor | — | 100.00 | — | — | |
| — | — | — | Above/ 33780.00 Below/P | ||
| Chapter-8: Fixing of Plug boards, 50-way terminal blocks with 2BA terminals, and wiring of relays as per the approved circuit diagram using wire PVC 16/0.2mm copper. Suitable wire supporting tray with cover made of PVC shall be provided horizontally and vertically in the relay racks. While running the wires on the aluminium ladder proper care shall be taken to provide smooth materials like rubber beading in the openings on phenolic sheets, to avoid damage to wires. The work also includes wiring of contacts for data logger and terminating them in tag blocks, provision of relay index board. (Supply of relays, plug boards, connectors and retaining clips is not covered in this item).[Wire PVC 16/0.2mm copper, tag blocks, 2BA terminals, hard wood plank of size 600mmx 900mmx25mm with decolam finish, MS angles of size 25mmX25mmX6mm, relay fixing bolts and nuts, teakwood plank 25mm thick for fixing resistors and condensers, phenolic sheet 6mm thick of size 1200mmX1800mm with aluminium grooved channel frame for relay index board, paints, soldering materials, bunching thread, wire wound resistance, condenser, wire supporting tray with cover of suitable size made of PVC, paint, varnish and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | — | 30.00 | — | — | |
| — | — | — | Above/ 510.00 Below/P | ||
| Chapter-8: Carefully opening the bunching inside the relay room as instructed, removing the relay pin along with the wire, neatly and carefully removing the wire duly testing with buzzer, re-bunching & placing with standard-grade nylon lacing twine and PVC dotted with buttons where required. | — | 30.00 | — | — | |
| — | — | — | Above/ 42002.00 Below/P | ||
| Chapter-8: Testing and commissioning of stations (up to 5 roads) the entire signalling installations jointly with the Railway representative at site at the stations covered under various schedules of the Contract, and ensuring that all the signalling gears are installed and adjusted as per the existing rules. The work also involves supply of required number of bound registers with good quality papers with all updated details of cable meggering, relays, batteries, block joints, route cancellation, relay room key entries, block instrument key, earth resistance etc., and handing over to Railways. (Supply of 'As mades' is not covered in this item). | — | 1.00 | — | — | |
| — | — | — | Above/ 5530.00 Below/P | ||
| Chapter-8: Arranging of sufficient staff by contractor and giving test to the railway in charge in testing of wires drawn point to point using buzzer. (Before and after soldering)[Sheet = Per Sheet] | — | 10.00 | — | — | |
| — | — | — | Above/ 100200.00 Below/P | ||
| Chapter-8: Supply and fixing of Flex printed Sun boards of various sizes of various drawings of Power diagram, Relay index chart, Station Rule Diagram, FTOT Particulars, yard layout diagram board etc, with different colours as per instructions of Site In-Charge/Railway Representative. | — | 200.00 | — | — | |
| — | — | — | Above/ 40476.00 Below/P | ||
| Chapter-8: Supply and Installation of Pre-wired Crank Handle Cum Key Lock Relay Box (of MS Sheet) along with LEDs, with approved type push buttons, Wago or similar Disconnecting type Terminal Blocks including DIN rail etc., as per approved drawing. Installation, fixing and wiring of boxes for Key Lock Relays to be carried by Contractor's wiring and fixing material. The work shall be carried as per the instructions of site engineer. | — | 1.00 | — | — | |
| — | — | — | Above/ 42500.00 Below/P | ||
| Chapter-8: Supply of Wago terminal of 2 conductor disconnecting terminal block for 2.5 sqmm wire termination make: wago/elmex or similar with accessories & taxes. | — | 500.00 | — | — | |
| — | — | — | Above/ 114540.00 Below/P | ||
| Chapter-10: Supply of NON-AC Immunized Relays, Plug-In-Type, style QN1, 8F/8B Contacts, DC Neutral line Relay, working voltage 24V DC, metal to carbon, with plug board, retaining clip and connectors as per RDSO Specification No BRS:930, IRS: S: 34 & IRS: S: 23, STR: SIQ 0420 Ver.1 or latest. The Interlocking code for this relay shall be ABCDF. | — | 30.00 | — | — | |
| — | — | — | Above/ 156270.00 Below/P | ||
| Chapter-10: Supply of AC Immunized Relays, Plug-In-Type style QNA1, 8F/8B Contact, DC Neutral line Relay, working voltage 24V DC, metal to carbon with plug board, retaining clip and connectors as per RDSO Specification No BRS:931A, IRS: S@58<44@ IRS:S:34 & IRS:S:23, STR: SIQ 0420 Ver.1 or latest. The Interlocking code for this relay shall be ABDGH | — | 30.00 | — | — | |
| — | — | — | Above/ 107200.00 Below/P | ||
| Chapter-10: Supply of Track Relays, Plug-in type, Style QTA2 - 9 Ohm, 2F-1B Contacts, metal to carbon with plug boards, connectors and retaining clips as per RDSO specification No. BRS:939A & 966(Appx F2) & IRS:S 23-88 Amdt.1, S34 & 60, STR: SIQ 0420 Ver.1 or latest. The interlocking code for this relay shall be FGHKX. | — | 20.00 | — | — | |
| — | — | — | Above/ 152760.00 Below/P | ||
| Chapter-10: Supply of AC Immunized Relays, Plug in type style "QSPA1" 8F/4B contacts, DC Neutral line Relay, slow to pick up, working voltage 24V DC, metal to carbon, complete with plug board, retaining clip and connectors as per RDSO Specification No. BRS:933A, IRS:S@58"44@ IRS:S:23; IRS S 60-78, STR: SIQ 0420 Ver.1 or latest. The interlocking code for this relay shall be ABDEJ. | — | 20.00 | — | — | |
| — | — | — | Above/ 93470.00 Below/P | ||
| Chapter-10: Supply of AC immunized Relays plug in type style QBCA-1, 2HF/4B contacts, DC Biased contractor Relay, Tractive armature, working voltage 24V DC with Heavy duty front contact, Metal to carbon complete with plug board, retaining clips and connectors as per RDSO specification No. BRS 943, IRS. S@46"44@ IRS.S.23 | — | 10.00 | — | — | |
| — | — | — | Above/ 240630.00 Below/P | ||
| Chapter-10: Supply of AC Lamp Proving Relays, plug in type, Style QECX, 4F-4B Contacts, working voltage 110 V AC, metal to carbon for LED aspects with plug boards, connectors and retaining clips as per RDSO specification No: BRS:941A, STS/E/RELAYS/AC LIT LED SIGNAL/09- 2002 Amdt1, IRS S-23 & 34, STR: SIQ 0420 Ver.1 or latest. The interlocking code for this relay shall be ABDHK. | — | 30.00 | — | — | |
| — | — | — | Above/ 50772.00 Below/P | ||
| Chapter-10: Supply of Key Lock Checking Relay (KLCR) working on24V DC, AC Immunized with different ward combinations and contact configuration 4F/4Bwith 2 extra ward plates and with case, RDSO spec no. RDSO/SPN/219/2016 ver 1.0 with amendment or latest, confirming to IRS S-23, S-34 & S@ 45<44@ IRS S:46. | — | 4.00 | — | — | |
| — | — | — | Above/ 26450.00 Below/P | ||
| Chapter-11: Data Validation and Software modification at site (Station) including additional relay/ bit wiring | — | 1.00 | — | — | |
| — | — | — | Above/ 22260.00 Below/P | ||
| Chapter-12: Supply of Low maintenance stationary secondary cells 2V-80AH capacity as per IRS: S 88/2004 Version 1.0 or latest. | — | 6.00 | — | — | |
| — | — | — | Above/ 3090.00 Below/P | ||
| Chapter-12: Supply of Hydro meter | — | 10.00 | — | — | |
| — | — | — | Above/ 2346.00 Below/P | ||
| Chapter-12: Charging of secondary cells 2V-80AH capacity. | — | 6.00 | — | — | |
| — | — | — | Above/ 1000.00 Below/P | ||
| Chapter-12: Supply of Non-deteriorating type Fuse links 20 Amps for Railway signalling, voltage 240 AC/DC to Specn. No. IRS S.78/2006. | — | 20.00 | — | — | |
| — | — | — | Above/ 1000.00 Below/P | ||
| Chapter-12: Supply of Non-deteriorating type Fuse links 16 Amps for Railway signalling, voltage 240 AC/DC to Specn. No. IRS S.78/2006. | — | 20.00 | — | — | |
| — | — | — | Above/ 490.00 Below/P | ||
| Chapter-12: Supply of Non-deteriorating type Fuse links 10 Amps for Railway signalling, voltage 240 AC/DC to Specn. No. IRS S.78/2006. | — | 10.00 | — | — | |
| — | — | — | Above/ 920.00 Below/P | ||
| Chapter-12: Supply of Non-deteriorating type Fuse links 6 Amps for Railway signalling, voltage 240 AC/DC to Specn. No. IRS S.78/2006. | — | 20.00 | — | — | |
| — | — | — | Above/ 1800.00 Below/P | ||
| Chapter-12: Supply of Non-deteriorating type fuse links 2 Amps for Railway signalling, voltage 240 AC/DC to Specn. No. IRS S.78/2006. | — | 50.00 | — | — | |
| — | — | — | Above/ 23802.00 Below/P | ||
| Chapter-15: Provision of Earth Electrodes as per RDSO Drawing No.SG/SWR/057 and Earthing of metallic sheath and armour of all cables in all apparatus cases, relay room, equipment room, ASM room for block and control, and earthing of all equipment's in apparatus cases, power room, relay rack, cable termination rack, control panel, signals, lever frames with MS of flat 35mm X 6mm or 19c cable (MS flat for closer by areas and MS flat/19c cable combination for farther areas) as per the instructions of Railway representative at site. The work includes painting of earth resistance value on the earth pit. (Supply of 19C cable is not covered in the scope of this schedule). [MS flat for earthing 35mm X 6mm, cement, GI earth electrodes, common salt, charcoal, country bricks, river sand, soldering materials and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | — | 6.00 | — | — | |
| — | — | — | Above/ 56684.00 Below/P | ||
| Chapter-15: Supply of Basic material to construct Unit maintenance free earth as per RDSO spec. No. RDSO/SPN/197 Ver.1.0 or latest. consisting of a) copper bonded steel electrode of 3.0m long, 17.0 mm dia with copper bonding thickness mini 250 micron and UL listed and marked--1 no. b) Earth enhancement compound of RDSO approved brand supplied in sealed bags of min 10 Kgs-03 No. c) Copper strip of 150X25x6mm to terminate earth rod-1 No. d) Copper strip of 300X25x6mm (MEEB)-1 No. e) Copper strip of 150X25x6mm (SEEB)-1 nos | — | 2.00 | — | — | |
| — | — | — | Above/ 30906.00 Below/P | ||
| Chapter-15: Installation of Unit Maintenance Free Earth Pit as per RDSO specification No.RDSO/SPN/197 Ver.1.0 or latest and as per Technical Specification | — | 2.00 | — | — | |
| — | — | — | Above/ 10040.00 Below/P | ||
| Chapter-18: Preparation of Table of Control based on SIP issued in Auto Cad in A3 size. Initially, contractor shall submit 2 sets of documents for approval of Railways. One set will be returned duly approved for making a fair copy or for re-submission for approval after incorporating the changes as required by Railways. After carrying out changes, two sets of Hard copies to be submitted for Railway Approval. After approval, Auto Cad copies to be submitted in USB pen drive along with approved copy in Tracing film and two sets of final approved drawing in properly bound booklet along its scanned copy. | — | 10.00 | — | — | |
| — | — | — | Above/ 11104.00 Below/P | ||
| Chapter-18: Preparation of Table of Control based on the approved Signalling Plan as per RDSO Sig DATE Format. AutoCAD in A3 size. Initially, Contractor shall submit 2 set of documents complete for approval of Railways. One set is returned either duly approved for making a fair copy or for re-submission for approval after incorporating the changes as required by railways. The TOC & Preliminary Check and Certification to be done by the IRSE or IRSTE (license holder). After carrying out necessary changes, two set of 'Hardcopies' are submitted for administrative approval. The final corrected drawings shall be supplied to Railways on 80/90 GSM Tracing film and 2 copies of blue print properly bonded booklets and the soft copy in USB Pen drive. | — | 8.00 | — | — | |
| — | — | — | Above/ 20450.00 Below/P | ||
| Chapter-18: Submission of all relevant final 'Asmades' of circuit diagrams, contact analysis charts, termination particulars of apparatus cases and cable termination rack, power supply arrangements, relay index board, cable plans, cable route plans, red boundary plans and all other particulars covered under various schedules. All 'As mades' shall be prepared by the Contractor in AUTOCAD 2000 or latest and submitted in CDs. One copy of the 'As mades' check print shall be submitted before Testing the circuits. The final negatives shall be made in tracing sheet (80 to 90 gsm). All 'As mades' except cable plan, cable route plan, bonding diagram & power supply diagram shall be prepared in A3 size. On approval the contractor shall submit along with the negatives, 8 copies in each, duly making booklet neatly bound. Out of 8 sets, 2 sets of drawings and other plans shall be kept in transparent plastic cover (2 sheets back-to-back in one plastic cover) and handed over to Railways. Also, the contractor has to supply one set of As made in 'Reproduction Film'. The approved circuit diagram will be issued by Railways in soft copy as well as two sets of hard copies. Wherever alterations to existing circuits are involved, the existing as-made circuit diagrams will be supplied by Railways either in CDs or RP film. The Contractor shall incorporate the details of all the new wirings and alterations in the CD/ RP film and submit them to Railways. On approval 8 copies shall be made for As- made circuit diagrams also as mentioned above. [Sheet = Per Sheet] | — | 50.00 | — | — | |
| — | — | — | Above/ 2730.00 Below/P | ||
| Chapter-18: Printing, Binding & supply of the following Registers with latest proforma given by in-charge officer each register of 100 pages. Station Asset Register/Deficiencies Book/Officer Inspection book/ Work site orientation classes note book /Station Message book/Infringement measure book fog signal gears/Route cancellation register/Relay room Key register/Cable testing summary/Signal maintenance record register/Power Systems Battery maintenance Register/Mechanical Signalling Register/Axle Counter Maintenance Register/Block instrument Maintenance Register/Track circuit maintenance Register/Lifting barriers maintenance Register/Electrically operated point maintenance Register/Electronic interlocking Maintenance Register/Location box maintenance Register/Earth Testing record Register/Relay room register/Joint Inspection of Points and Crossings register/Block Proving Axle Counter Register/Diesel generator /SoIar panel Register. [Per Unit = Per Register] | — | 10.00 | — | — | |
| — | — | — | Above/ 45632.00 Below/P | ||
| Chapter-19: Digital Multimeter 100 KHz (Hand Held) Brand: RISHABH 18S or similar. | — | 2.00 | — | — | |
| — | — | — | Above/ 19248.00 Below/P | ||
| Chapter-19: Supply of Digital Megger with range selection of 500V, 100V. Make RISHABH or similar. | — | 2.00 | — | — | |
| — | — | — | Above/ 16918.00 Below/P | ||
| Chapter-19: Supply of Digtal Earth Tester Det-1 with metal carrying box and auxiliary earthing net Make Wago or better. | — | 2.00 | — | — | |
| — | — | — | Above/ 37854.00 Below/P | ||
| Chapter-19: Supply of Optical power meter wave length 800 - 1600nm, range 45 to + 10 dBm as per technical specification. Make EXFO or better. | — | 2.00 | — | — | |
| — | — | — | Above/ 4218.00 Below/P | ||
| Chapter-19: Supply of Rodometer (Distance Recorder) as per latest specification. Make Bosch Model No: 1011662 or better. | — | 1.00 | — | — | |
| — | — | — | Above/ 38802.00 Below/P | ||
| Chapter-19: Supply of electric track drilling machine with suitable horizontal stand with attachments to drill holes of various sizes up to 7mm to 13mm Make Ralliwolf Model WD 34 C or similar. | — | 2.00 | — | — | |
| — | — | — | Above/ 14545.00 Below/P | ||
| Chapter-19: Supply of Crimping Tool for RJ 45. | — | 5.00 | — | — | |
| — | — | — | Above/ 24668.00 Below/P | ||
| Chapter-19: "Wet and Dry heavy Industrial Vacuum Cleaner 240 millibar Make: Philips ,Bosch or similar." | — | 1.00 | — | — | |
| — | — | — | Above/ 9299.00 Below/P | ||
| Chapter-19: Welding Machine Portable Inverter type | — | 1.00 | — | — | |
| — | — | — | Above/ 286500.00 Below/P | ||
| Chapter-20: Providing the services of Computer oriented Technical manpower to carryout works like drawing, computation, write up etc., using computer, using software like AUTOCAD, MS Office etc., between 08.00 Hrs and 20.00 Hrs of the day with all expenses of transportation, accommodation, food, consumables etc., with all ascents, descents, taxes, octroi, cess, fees, duties with contractors cost etc., as per special conditional/specifications/ regulations and as directed by Engineer-in-charge. Note: The person engaged for providing the services shall be convergent with computer working knowledge in above software's." [Man-Days = Per Man-Days] | — | 300.00 | Man-Days | — | |
| — | — | — | Above/ 5681.00 Below/P | ||
| Chapter-21: Fixing of 'Telecom Termination Panel' and termination of cables on Wago/krone connectors as per the instructions of the site Engineer. | — | 1.00 | — | — | |
| — | — | — | Above/ 8688.00 Below/P | ||
| Chapter-21: Supply of Wago/Pheonix/Elmex make or similar. | — | 2.00 | — | — | |
| — | — | — | terminals | ||
| — | — | — | Above/ 6878.00 Below/P | ||
| Chapter-21: Fixing of Wago/Phoenix//Elmex make or similar | — | 2.00 | — | — | |
| — | — | — | terminals | ||
| — | — | — | Above/ 5862.00 Below/P | ||
| Chapter-21: Supply Wago/Pheonix/Elmex make or similar | — | 2.00 | — | — | |
| — | — | — | terminals | ||
| — | — | — | Above/ 5310.00 Below/P | ||
| Chapter-21: Fixing of 10 pair CT box with disconnecting terminals of wago/phonix/elmex make or similar and termination of cable at the station/LC gates etc. This includes fixing of Quad/PIJF cables and CT box on the wall. | — | 2.00 | — | — | |
| — | — | — | Above/ 3972.00 Below/P | ||
| Chapter-22: Provision of PA system and Magneto telephone communication at stations/ tents as per the instructions of Railway representative at site. The PA system and magneto telephones will be returned to the contractor after the completion of NI working. Signalling cables available may be used for the communication. (Hiring of PA system equipments and magneto telephones shall be done by the Contractor) [All other miscellaneous materials required for the work shall be supplied by the Contractor].[Day= Per Day] | — | 2.00 | — | — | |
| — | — | — | Above/ 2774.00 Below/P | ||
| Chapter-22: Hiring of tarpaulin tents and providing the same at places as instructed by Railway representative at site. The spacing inside the tent shall be app 8ft x 8 ft. Each tent shall be provided with a table, chair, tube lights and pedestal fan. Drinking water in cans. The tents shall be fixed firmly to withstand rain, strong wind etc. {Unit: per Tent per Day} | — | 2.00 | — | — | |
| — | — | — | Above/ 16381.00 Below/P | ||
| Chapter-22: Supply of Office table with plywood plank with thickness of 18mm, teakwood beading with three draws of size 4' X 2' with heavy duty 'S' type chair with hand rest. The above is of Godrej or similar make | — | 1.00 | — | — | |
| — | — | — | Above/ 3786.00 Below/P | ||
| Chapter-22: Navtal locks or godrej make 75mm or better with 2 keys. | — | 6.00 | — | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCC_April-2022.pdf
ATTACHMENT
ACS1to10_compressed.pdf
ATTACHMENT
ConservancyChargesdt07092021.pdf
ATTACHMENT
Chapter_4B_TechnicalGuidelines1.pdf
ATTACHMENT
Safety Critical Items
ATTACHMENT
JRU_RRB_Tech_Specification_F.pdf
ATTACHMENT
AllSimilarNatureWorksGuidelines-260925.pdf
ATTACHMENT
Smilarnaturedt030424F.pdf
ATTACHMENT
Annexure-VAformat.pdf
ATTACHMENT
JPO_Digging.pdf
ATTACHMENT
Localcontents_lessthan10crores1.pdf
ATTACHMENT
ProformDetails.pdf
ATTACHMENT
Tenderform-1.pdf
ATTACHMENT
VettedGDForm_JRUShunting_Tripshed_ShuntingRRB.pdf
ATTACHMENT
LettertoZonesclarificationNDKR1_RDKR1CKTdt15.07.2025.pdf NDKRI RDKRI
ATTACHMENT
TBook_JRUShuntingNeck_TripShed_ShuntingNeckRRB.pdf
ATTACHMENT
GCC_ACS11.pdf
ATTACHMENT
InspectionofSafety-CriticalSignallingItemsbyRDSOdt260925.pdf
ATTACHMENT
LettertoZonesclarificationNDKR1_RDKR1CKTdt15.07.2025.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .