| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.3 LAccepted-Finance 685 SONARPUR STATION ROAD GREEN PARK KOLKATA 700103 | KOLKATA | 24 PARAGANAS SOUTH | WEST BENGAL | 700103 | ₹7.3 L | L1 | Accepted-Finance Quoted rate found Lowest (L1). |
| 2 | L2₹7.8 LRejected-Finance VILL DAKSHIN SHIBGANJ P O AND P S PATHARPRATIMA DIST SOUTH 24 PARGANAS | SOUTH 24 PARGANAS | WEST BENGAL | ₹7.8 L | L2 | Rejected-Finance Quoted rate found 2nd Lowest (L2). |
| 3 | L3₹7.9 LRejected-Finance 119 MONOHAR PUKUR ROAD KOLKATA 700 026 | KOLKATA | KOLKATA | WEST BENGAL | 700026 | ₹7.9 L | L3 | Rejected-Finance Quoted rate found 3rd Lowest (L3). |
| Sl No | Description | Qty | Unit | WISE CHOICE L1 | B. ENGINEERING CO. L2 | UNITED CONSTRUCTION SERVICE L3 |
|---|---|---|---|---|---|---|
| 1.00SITC of BASED online UPS (KVA/KW): 30KVA /27 KW with 30 min battery back up (Make Numeric / APC / Vertiv / Switching AVO) of following specifications: Input voltage: 310… 400…415 VAC 180-264 Volt / Phase (selectable) Input frequency: 40 to 70Hz, PF: 0.99with IGBT Rectifier, isolation transformer: Delta to star inbuilt Isolation Transformer with 1:1 ratio at UPS input to be provided, Back feed Protection: UPS should have back feed protection, DC Ripple: Residual ripple voltage should be < 1% Charging: Autometic float cum boots charging capability with setteble flote & boost charging voltages & current levels & boots charger timer, output voltage: 380....400...415V (Selectable) output voltage regulation: Static Variation +/-1% & Dynamic variation +/-3% Output frequency: 50Hz +/-0.1% output Power factor: 0.9 waveform: Pure sine wave, Overload: 110% for 60minutes, 125% for 10 minutes, 150% for 1 minutes. Static by pass: 100% rated static switches with fuseprotection overload on bypass: 100% for 10 ms, Battery : | ||||||
| 1.0112V Mono Block batteries the UPS battery shall be of advanced Glass Mat valve regulated sealed lead Acid battery make Exide/AmaronConstruction type (AGM or VRSLAB) in ABS flame retardant (UL94V-O) grade (UL 2436) spill containment casing to meet UL 62368-1/IEC 62133 or equivalent standards type to obtain a full rated load battery backup battery cabinet: with power coated MS angle withMS sheet suitable dimension, well air ventilation to ensure the battery optimum life cycle. Proper rating cables for interlink cables & battery input & necessary acessiress. Protections: input & Output over/ Under voltage single phasing, DC - High / under voltage, Battery charging over current, output overload / Short Circuit/ Over temp. UPS auto ON on mains recovery protections. {Battery capacity (VAH) minimum 24960 VAH} | ||||||
| 1.02 | Input & Output over / under voltage, single phasing, DC - High/ under voltage, battery charging over current output overload/ short circuit/ over temp. UPS auto ON mainsrecovery switchgear: MCB/MCCB for input battery, output & manual bypass switch operating temp. 0 to 40Deg C, IP 20enclosure, RH max 95% forced air cooling, max sound less then 60db, communication: Rs232, Rs. 485, dual input Kit, monitoring software: UPS monitoring software on windows XP platform, Certification:ISO 9001:2015 ISO 14001: 2015, ISO 18001 RoHS & OHSAS 18001, CE Certification: IEC/EN 62040-1-1, IEC/EN50091-1, IEC/EN 60950 (safety) IEC/ EN 50091-2, IEC/EN 62040-2 (EMC Emmission), IEC/EN 62040-3 (performance & Design) IEC/EN 61000-4 (EMC Emmunity) & IEC/EN 60146.
(Three years spare & maintenance warranty after commissioning of the UPS to be provided; security deposit will be released after three years of commissioning date). | 1 | Item | 7,33,390 ₹7.3 L | 7,80,000 ₹7.8 L | 7,88,500 ₹7.9 L |
| 2.00TERMS & CONDITIONS | ||||||
| 3.00(i) Rate should be quoted inclusive of all applicable taxes and Duties etc including GST. (ii) The Agency must procure the materials for the Manufacturer / OEM or from their authorized sales channel, so that the standard warranty / support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them. iii) Documents that authenticate such procurement from the manufacturer /OEM or from their authorized sales channel and standard warranty / support should be sent from the e-mail of the Manufacturer / OEM / authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution of work / submission of bill. iv) If any refurbished material is supplied and installed, penal action will be taken as per existing rules. | ||||||
Tender Value
Refer Docs
EMD Value
₹15,800
Closing Date
16 Jan 2026, 2:00 pmClosed
EXECUTIVE ENGINEER PWD MALDA ELECTRICAL DIVISION
O/O THE EXECUTIVE ENGINEER PWD MALDA ELECTRICAL DIVISION Singatala Malda PIN 732101
Upgradation of Gazol Rural Hospital to State General Hospital or District Hospital, Gazole RH, Malda - SITC of Online UPS
2025_WBPWD_962910_1
WBPWD/EE/MED/e-NIQ-44/2025-26
Open Tender
Electrical Work/ Equipment
20 days
Gazole
Please refer Tender documents.
6 documents required · 6 mandatory
₹15,800
26 Feb 2026
28 Nov 2025
19 Jan 2026
28 Nov 2025
16 Jan 2026