| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.3 LAccepted-AOC 685 SONARPUR STATION ROAD GREEN PARK KOLKATA 700103 | KOLKATA | 24 PARAGANAS SOUTH | WEST BENGAL | 700103 | L1 | Accepted-AOC Quoted rate found Lowest (L1). | |
| 2 | L2₹7.8 L+₹46,610 (6.36%)Rejected-Finance VILL DAKSHIN SHIBGANJ P O AND P S PATHARPRATIMA DIST SOUTH 24 PARGANAS | SOUTH 24 PARGANAS | WEST BENGAL | L2 | Rejected-Finance Quoted rate found 2nd Lowest (L2). | |
| 3 | L3₹7.9 L+₹55,110 (7.51%)Rejected-Finance 119 MONOHAR PUKUR ROAD KOLKATA 700 026 | KOLKATA | KOLKATA | WEST BENGAL | 700026 | L3 | Rejected-Finance Quoted rate found 3rd Lowest (L3). |
| Sl No | Description | Qty | Unit | WISE CHOICE L1 | B. ENGINEERING CO. L2 | UNITED CONSTRUCTION SERVICE L3 |
|---|---|---|---|---|---|---|
| 1.00SITC of BASED online UPS (KVA/KW): 30KVA /27 KW with 30 min battery back up (Make Numeric / APC / Vertiv / Switching AVO) of following specifications: Input voltage: 310… 400…415 VAC 180-264 Volt / Phase (selectable) Input frequency: 40 to 70Hz, PF: 0.99with IGBT Rectifier, isolation transformer: Delta to star inbuilt Isolation Transformer with 1:1 ratio at UPS input to be provided, Back feed Protection: UPS should have back feed protection, DC Ripple: Residual ripple voltage should be < 1% Charging: Autometic float cum boots charging capability with setteble flote & boost charging voltages & current levels & boots charger timer, output voltage: 380....400...415V (Selectable) output voltage regulation: Static Variation +/-1% & Dynamic variation +/-3% Output frequency: 50Hz +/-0.1% output Power factor: 0.9 waveform: Pure sine wave, Overload: 110% for 60minutes, 125% for 10 minutes, 150% for 1 minutes. Static by pass: 100% rated static switches with fuseprotection overload on bypass: 100% for 10 ms, Battery : | ||||||
| 1.0112V Mono Block batteries the UPS battery shall be of advanced Glass Mat valve regulated sealed lead Acid battery make Exide/AmaronConstruction type (AGM or VRSLAB) in ABS flame retardant (UL94V-O) grade (UL 2436) spill containment casing to meet UL 62368-1/IEC 62133 or equivalent standards type to obtain a full rated load battery backup battery cabinet: with power coated MS angle withMS sheet suitable dimension, well air ventilation to ensure the battery optimum life cycle. Proper rating cables for interlink cables & battery input & necessary acessiress. Protections: input & Output over/ Under voltage single phasing, DC - High / under voltage, Battery charging over current, output overload / Short Circuit/ Over temp. UPS auto ON on mains recovery protections. {Battery capacity (VAH) minimum 24960 VAH} | ||||||
| 1.02 | Input & Output over / under voltage, single phasing, DC - High/ under voltage, battery charging over current output overload/ short circuit/ over temp. UPS auto ON mainsrecovery switchgear: MCB/MCCB for input battery, output & manual bypass switch operating temp. 0 to 40Deg C, IP 20enclosure, RH max 95% forced air cooling, max sound less then 60db, communication: Rs232, Rs. 485, dual input Kit, monitoring software: UPS monitoring software on windows XP platform, Certification:ISO 9001:2015 ISO 14001: 2015, ISO 18001 RoHS & OHSAS 18001, CE Certification: IEC/EN 62040-1-1, IEC/EN50091-1, IEC/EN 60950 (safety) IEC/ EN 50091-2, IEC/EN 62040-2 (EMC Emmission), IEC/EN 62040-3 (performance & Design) IEC/EN 61000-4 (EMC Emmunity) & IEC/EN 60146.
(Three years spare & maintenance warranty after commissioning of the UPS to be provided; security deposit will be released after three years of commissioning date). | 1 | Item | 7,33,390 ₹7,33,390 Lowest | 7,80,000 ₹7,80,000 | 7,88,500 ₹7,88,500 |
| 2.00TERMS & CONDITIONS | ||||||
| 3.00(i) Rate should be quoted inclusive of all applicable taxes and Duties etc including GST. (ii) The Agency must procure the materials for the Manufacturer / OEM or from their authorized sales channel, so that the standard warranty / support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them. iii) Documents that authenticate such procurement from the manufacturer /OEM or from their authorized sales channel and standard warranty / support should be sent from the e-mail of the Manufacturer / OEM / authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution of work / submission of bill. iv) If any refurbished material is supplied and installed, penal action will be taken as per existing rules. | ||||||
Tender Value
Refer Docs
EMD Value
₹15,800
Closing Date
16 Jan 2026, 2:00 pmClosed
EXECUTIVE ENGINEER PWD MALDA ELECTRICAL DIVISION
O/O THE EXECUTIVE ENGINEER PWD MALDA ELECTRICAL DIVISION Singatala Malda PIN 732101
Upgradation of Gazol Rural Hospital to State General Hospital or District Hospital, Gazole RH, Malda - SITC of Online UPS
2025_WBPWD_962910_1
WBPWD/EE/MED/e-NIQ-44/2025-26
Open Tender
Electrical Work/ Equipment
Item Rate
20 days
Gazole
Please refer Tender documents.
6 documents required · 6 mandatory
₹15,800
24 Aug 2026
28 Nov 2025
19 Jan 2026
28 Nov 2025
16 Jan 2026
5 Dec 2025
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .