Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.7 CrAccepted-AOC | ₹13.7 Cr Quoted ₹15.0 Cr | L1 | Accepted-AOC Being Lowest Tenderer |
| 2 | L2₹15.1 CrRejected-Finance | ₹15.1 Cr | L2 | Rejected-Finance Being Not Lowest Tenderer |
| 3 | L3₹15.7 CrRejected-Finance | ₹15.7 Cr | L3 | Rejected-Finance Being Not Lowest Tenderer |
| 4 | L4₹16.4 CrRejected-Finance K 99 LGF KALKAJI NEW DELHI 110 019 | NEW DELHI | SOUTH EAST DELHI | DELHI | 110019 | ₹16.4 Cr | L4 | Rejected-Finance Being Not Lowest Tenderer |
| 5 | L5₹16.4 CrRejected-Finance | ₹16.4 Cr | L5 | Rejected-Finance Being Not Lowest Tenderer |
Tender Value
₹15.2 Cr
EMD Value
₹10.8 L
Closing Date
16 Mar 2023, 6:00 pmClosed
CE (AF) GANDHINAGAR
LEKAWADA PATIA CHILODA GANDHINAGAR 382042
DEMOLITION AND RECONSTRUCTION OF SMQs AT AF STN MUMBAI (PHASE-I)
2023_MES_578437_1
84196
Open Tender
Civil Works
720 days
GE (AF) THANE
AS PER NIT AND TENDER DOCUMENTS
9 documents required · 9 mandatory
₹3,000
GE (AF) THANE
₹10.8 L
Yes
3 Apr 2023
1 Feb 2023
18 Mar 2023
1 Feb 2023
16 Mar 2023
2 Mar 2023
5 Feb 2023 - 12 Feb 2023
Amount
NOTE: Schedule ‘A’ Part I to XIII under Ser No. 1.00 to 13.00 are prepriced by MES. Bidders shall insert their lumpsum amount in the green coloured field under Col-6 only.
Lump sum price worked out for BUILDINGS/ STRUCTURES as listed in Sch 'A' Part I.
Lump sum price worked out for DEMOLITION as listed in Sch 'A' Part II
Lump sum price worked out for EXCAVATION, EARTH WORK AND SITE CLEARANCE as listed in Sch 'A' Part III
Lump sum price worked out for INTERNAL ELECTRIFICATION as listed in Sch 'A' Part IV
Lump sum price worked out for INTERNAL WATER SUPPLY as listed in Sch 'A' Part V
Lump sum price worked out for SEWAGE DISPOSAL as listed in Sch 'A' Part VI
Lump sum price worked out for AREA DRAINAGE as listed in Sch 'A' Part VII
Lump sum price worked out for ROAD/ PATH/ HARDSTANDING as listed in Sch 'A' Part VIII
Lump sum price worked out for EXTERNAL ELECTRIFICATION as listed in Sch 'A' Part IX
Lump sum price worked out for EXTERNAL WATER SUPPLY as listed in Sch 'A' Part X
Lump sum price worked out for DG SET AND LIFT as listed in Sch 'A' Part XI
Lump sum price worked out for FIRE FIGHTING SYSTEM as listed in Sch 'A' Part XII
Lump sum price worked out for LIGHTENING PROTECTION as listed in Sch 'A' Part XIII
SCHEDULE 'A' PART - XIV MISCELLANEOUS ITEMS is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signifies this fact only. Bidder shall insert their rates in Green filed under Col-6.
EXCAVATION, EARTH WORK AND SITE CLEARANCE
Removing excavated soil and depositing outside MD land complete all as specified and as directed.
DEMOLITION
Taking up or down GI tubing and connections of bore 25 mm to 50 mm complete all as specified and as directed.
Removing building materials outside MD land etc. including loading and unloading of materials complete all as specified and as directed.
Taking down submain wiring any type and any size complete all as specified and directed.
Taking down carefully ceiling fan, geyser, exhaust fan, wall mounted fans, electric meter etc. of any make and type from ceiling/ wall and depositing it to MES yard complete all as specified and as directed.
Taking down DB/ TPN (including MCCB/ MCB), main switch of any capacity complete all as specified and directed.
Taking down old unservicable LT XLPE cable any size complete all as specified and directed.
Taking down old unservicable RCC LT pole including light fittings, GI clamps and looping box any size complete all as specified and directed.
Taking down old LT feeder box from foundation complete all as specified and directed.
Taking up or down GI pipe of any size including light fittings and fixtures complete all as specified and directed.
Disconnection and dismantling of CI pipeline 150mm with control valves including fittings and fixtures complete all as specified and directed.
Dismantling of valve pit chamber of any size complete all as specified and directed.
Disconnection and dismantling of MS/GI pipeline 100mm with control valves including fittings and fixtures complete all as specified and directed.
Disconnection and dismantling of MS/GI pipeline 80mm with control valves including fittings and fixtures complete all as specified and directed.
Disconnecting electric connections and dismantling of pumping set with motor of any capacity ( fresh water supply pump 20 HP- 2 Nos, fresh water to SMC pump 3 HP- 2 Nos, fire fighting (Main Pump, 50 HP)- 1 No, Jockey pump, 15 HP- 1 No, Trace pump 2Hp- 2 Nos with control panel and connected accessories, cables and deposited to AGE E/M store yard all as specified and as directed.
INTERNAL ELECTRIFICATION
Supply and fix RCCB, 2 pole SPN, as per IS 12640-1, IEC 61008-1 with rated sensitivity of 32A, 30mA for protection against earth leakage current for domestic use to fix in MCB DB complete along with connection and testing complete all as specified and directed.
Supply and fix energy efficient 10 Watts B-22 bore LED lamp working at 230 Volts 50 Hz complete all as specified and directed.
Supply, install, testing and commissioning of factory made and tested (CPRI approved maufacturer) LT feeder pillar box (KIOSK) indoor type, platform mounted, including suitable angle iron (4 Nos leg) for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, all as specified and directed, having bus bar chamber with insulated copper bus bars 300 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof, made of 2.00 mm CRCA sheet 75mm x 30 mm thick MS channel frame, duly powder coated finish, thimbling and cable entry boxes with cable gland including painting with two coat of synthetic enamel paint over a coat of red oxide primer, front and back side opening type with aprons for cable entry with double door shutter and locking arrangement, danger plate and earthing terminal and suitable PCC work complete all as specified and directed. The scope of work includes provision of the following:- Incoming:- (a) MCCB 4 pole 100 Amps, 36 KA, 415V - 01 No (b) Bus bar (copper strip) 200 Amp - 4 Nos (c) Digital panel meter (Amp Voltage meter) including CTs - 01 No (d) Digital indication lamp set - 01 Set (e) Slot for electronic energy meter - 17 Nos Outgoing:- (i) MCB SPN 40 Amp 415 V 50 Hz-17 Nos Note:- Contractor shall submit LT panel drawing for approval of GE before procurement.
Supply and fix LED light fitting with high output diffuser 2 feet, 10 Watt, 220 V AC decorative type with driver and LED lamp 5700K Rated CCT energy efficient with lumen efficiency corresponding to five star BEE rating published for year of installation, pf 0.8, colour rendering index not less than 70%, IP20 complete with all accessories internally pre-wired including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed.
Supply and fix cable tray perforated aluminium pre-galvanised fixing, passing through vertical wall, chiseling, cutting on vertical/ horizontal wall including making good of disturbed surface complete all as specified and dircected.
INTERNAL WATER SUPPLY
Supply and fix concealed type/ fancy type brass CP mixer for mixing hot and cold water with provision for overhead shower with 115mm long bend pipe for 15 mm dia iron pipe and fixed including fittings complete all as specified and directed.
Supply and fix two way bib cock, 15 mm dia (ISI marked), fancy type, chromium plated complete all as specified and directed.
Supply and fix health faucet (ABS body) mild steel chromium plated, suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed.
ROAD/ PATH/ HARDSTANDING
Material and labour for polythene film, black, 400 micron laid in floors complete all as specified and directed.
Material and labour for providing and painting 2.5 mm thick road marking strip (retro reflective) of specified shade/ colour using hot thermoplastic material by fully/ semi automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoe heater, driven by experienced operator on road surace including all cost of material, labour, T&P, cleaning of road surface of dirt, seals, ils, grease and foreign material etc. complete all as specified and directed.
Supply and fix ABS dual directional UV protection reflective panels/ road studs/ cat eyes made of plastic body of size 90x110x17mm fixed to the surface with epoxy adhesive as per manufacturer's instruction of specified make or equivalent, Amber, Red or white in colour complete all as specified and directed. Make - 3M 290 series or equivalent as approved by GE.
EXTERNAL ELECTRIFICATION
Supply and fix junction box loop out with suitable connection for three phase incoming cable 3 phase outgong cable and single phaseconnection for light fittings with controlles MCB SP-6 Amps - 01 No. enclosed in thermo pastic in closed shock proof safe all as specified and directed.
Supply and fix in GI tubing brckets made up of light grade 40 mm dia 1.5 meter length and bent to shape at factory of offset angle up to 120 degree for fixing of LED street light fittings including preparing surfaces of steel tubing and apllying two coats of alluminum paint all as specified and directed.
Suppyling, installing, testing and commissioning of factory made outdoor type LT panel board of size not less than 120cmx120cmx65cm outer shell shall be made out of 3.15 mm thick CRCA sheet duly powder coated completely weather, vermin and dust proof, CPRI approved with colour code PVC sleep for bus bar, suitable for operation on 415 volts, 3 phase, 4 wire 50Hz supply system inlcluding closed bus bar chamber, front opened, with locking arrangements etc. angle iron frame of size 50x50x6mm for skeleton and support embeded in concrete foundation duly painted with 2 coats of synthetic enamel paint over a coat of red oxide primer on exposed surfaces grouted in PCC comprising of following accesories:-
Suppyling, installing, testing and commissioning of factory made outdoor type LT panel board of size not less than 120cmx120cmx65cm outer shell shall be made out of 3.15 mm thick CRCA sheet duly powder coated completely weather, vermin and dust proof, CPRI approved with colour code PVC sleep for bus bar, suitable for operation on 415 volts, 3 phase, 4 wire 50Hz supply system inlcluding closed bus bar chamber, front opened, with locking arrangements etc. angle iron frame of size 50x50x6mm for skeleton and support embeded in concrete foundation duly painted with 2 coats of synthetic enamel paint over a coat of red oxide primer on exposed surfaces grouted in PCC comprising of following accesories:-
EXTERNAL WATER SUPPLY
Supplying, laying, jointing, commissioning and testing 100 mm (4") bore centrifugally cast (spun) ductile iron pressure pipe with spigot and socketed ends class K-9, conforming to IS: 8329/ 2000 blast furnace slag cement with portland cement properties suitable for rubber gasket jointing/ tyton joints with inside cement mortar lining and black bitumen external coating, duly ISI marked and laid in trenches complete all as specified and directed. Note:- (i) DI fittings shall be measured and paid separately under respective items (ii) Excavation/ earthwork shall be measured and paid separately under respective item of schedule for excavation
Supply and fix gun-metal, globe or gate valves (ISI marked) conforming to IS 9338, 80 mm dia bore with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
Material and labour for construction of brick masonry valve pit of internal size 90cm x 90cm x 90cm suitable for gate valves/ sluice valve upto 150 mm including necessary excavation and earth work, brick work, plastering, white wash, PCC coping, MS frame made out of angle iron of size 50mmx50mmx6mm, MS sheet cover of 2 mm thick fixed to angle iron frame by means of hinges welded to frame and painting with 2 coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces and grouting the frame in PCC 1:2:4 type B-1 including handle and locking arrangement with one number 50 mm dia brass pad lock complete all as specified and directed. Note:- (i) Brick wall shall be 23 cm thick built in cement mortar (1:6) (ii) Internal plaster shall be 15 mm thick in cement mortar (1:4) and external plaster upto 450 mm from top shall be 20 mm thick in CM (1:6) and remaining external surface shall be flush pointing in CM (1:6) as the work proceeds (iii) PCC in foundation shall be 15 cm thick in cement concrete (1:4:8) type D2 using 40 mm graded stone aggregate extended 15 cm all around from the external face of the walls (iv) PCC coping shall be 15 cm thick in cement concrete (1:2:4) type B1 using 20 mm graded stone aggregate including grouting of angle iron frame in PCC (v) Three coats of white wash to internal surfaces of valve pit shall be provided (vi) Depth of valve pit shall be reckoned from the top of PCC in foundation
Supplying, installation, commissioning and testing of submersible pumping set, electric driven 15WHP including all necessary fittings complete all as specified and directed.
Supplying, installation, commissioning and testing of submersible pumping set, electric driven 5WHP including all necessary fittings complete all as specified and directed.
Supplying, installation, commissioning and testing of DOL starter, electric driven, 3 Phase suitable for 15WHP submersible pump including all necessary fittings complete all as specified and directed.
Supplying, installation, commissioning and testing of DOL starter, electric driven, 3 Phase suitable for 5WHP submersible pump including all necessary fittings complete all as specified and directed.
DG SET AND LIFT
Supply, installalation and testing of water cooled Diesel Engine driven Prime duty Generating Set of net capacity after all derating factors net of not less than 100 KVA/ 80 KWe, 50Hz, 415 Volt, 3 phase, 4 wire, 0.8 lagg, 126.5 HP minimum required power for rated kVA (HP) along with AMF system with Acoustic Enclosure exhaust silencer Hospital Grade in line, as per the noise emmission standards laid down by MoEF/ CPCB norms, along with Emission Control Device along with accessories, supporting brackets as per Central Pollution Control Board/ National Green Tribunal/ Min. of Environment, Forest and Climate Change complete all as specified and directed with and including following accesories:- A) Engine comprising of the following: Rugged engine natural liquid cooled (EG Compleat 50:50) with radiator as secondary media with world class OEM such as Cummins/ Perkins/ Kohler/ Greaves/ Ashok Leyland Engines for powered diesel generator set along with these specifications of Advanced in-cylinder technology turbo charged, air cooled aspriated to meet latest emission norms without any after-treatment device, class defining technology engine designed to meet stringent exhaust emission tests as per revised MoEF norms, thus offering environment friendly power, compact in size with optimum power to weight ratio, 6 cylinder, in-line 4 stroke, radiator cooled engine, well designed air handling system with dry type, heavy duty, replaceable paper element aircleaner with restriction indicator, air to air aftercooling, optimised turbocharger for increased altitude capabilities, best in class fuel economy with in-line fuel pump with A1 class mechanical governing, spin on fuel filter, standard integral set-mounted radiator system, designed and tested for 50°C ambient temperature, full flow spin on lube oil filter, first fill of lube oil and coolant, electrical starter motor with soft start engagement feature, battery charging alternator, 1 x 12 V DC battery/ alternator.
B) Alternator PMG type comprising of the following: Stamford UC/ Jyothi/ Crompton alternator frames from Technologies Brushless type, Screen protected, Revolving field, Self excited alternator conforming to IS/ IEC 60034-13, Phase reconnectable winding with 12 terminals brought out for connection, Dedicated winding specially designed for 1 phase and 3 phase operation, Better motor starting capability, Best in class efficiency, Compact design with sealed bearings for longer life and lesser maintenance, Impregnation on all wound components for better mechanical strength, Voltage regulation (Max.) ±1%, Class of Insulation H Class, Winding Pitch 2/3, Stator Winding Double layer lap, Rotor Dynamically Balanced, Waveform distortion/ Total Harmonic Distortion No load < 1.5 %, Non distorting balanced linear load < 5 %, Maximum Unbalanced Load across phases less than or equal to 25%, Telephonic Harmonic factor < 2% alternator capacity net output shall not be less than 100 KVA/ 80 KWe, 50Hz, 415 volt, 3 phase, 4 wire, 0.8 lagg, 139.1 Amp/ phase. Control Panel comprising of the following: (c) AMF/ Control panel manufactured with 14/16 gauge CRCA sheet and powder coated for weather-proof and long lasting finish.The control panel shall consist of the following parts of makes as per OEM recomendation; Microprocessor based generator set monitoring and control system, AMF Functionality shall be inbuilt and this control shall include an intuitive operator interface that allows for complete generator set control as well as system metering, fault annunciation, configuration, and diagnostics, Copper bus bars with suitable capacity with incoming/ outgoing terminals, Indicating lamps for ‘Load ON’ and ‘Set Running’,Instrument fuses/ MCBs duly wired and ferruled, Circuit breakers of suitable rating with overload and short circuit protections along with motorised change over swich for auto/ manual operations along with control contactors with copper busbars, cables and protective acessories with load/ bypass arrangements.
Hospital Grade silencer: Critical grade silencer with Rain Cap suitably optimized to meet stringent noise emission standards laid down by MoEF/ CPCB along with MS supporting structures along with thermal Insulation on horizontal pipe with Mineral Wool/ Asbestos Rope 50mm Thick wire mesh and 26 gauge aluminium cladding (12"). (d) Controller should be compatable to the following specifications: (i)AMF Functionality controllers of Makes from the OEM: Deep Sea/ Cummins/ Wood Ward/ Com Amp (ii) Intuitive operator interface which includes LED backlit 128X64 pixel graphic display with tactile feel soft-switches. Indications - Generator set, Utility Status Lamp. (iii) Remote start-stop with Engine Metering: Oil pressure, Engine temperature, Starting battery voltage, Engine running hours (iv) AC Alternator Metering: L-L Voltage and L-N Voltage, Current (phase and total), kVA (phase and total) and Frequency kwh, Total & per phase (kw & kVA), PF, Utility Voltage and Freq. (v) Engine Protection: Low lube oil pressure, High/ Low coolant temperature, Battery Over/ Under/ Weak Volts, Fail to Crank/ Start, Sensor failure, Cranking lockout, Low fuel level. (vi) AC Alternator Protection: Over/ Under Voltage, Over/ Under Frequency, Loss of AC sensing, Overspeed, Over Current. (vii) Data Logging: Engine hours, Control hours and upto 5 recent fault codes (viii) Configurable glow plug control, Cycle Cranking (ix) 12/24 Volt DC operation, Sleep mode, Modbus interface (RS485 RTU), InPower compatible (PC based service tool), Certifications- meets the requirement of relevant ISO, EN, Mil Std. and CE standards
(x) Maintenance due alarm based on Engine Run Time and due date, Exercisor scheduler (xi) Remote HMI, Digital electronic governor with temperture compensation and smooth starting, digital AVR for shunt of PMG excitor with Torque monitoring (e) All pipe line connections, valves etc.required for the lube oils, fuel and cooling system (f) Battery & Battery charger of rated capacity as per the alternator/ Engine compatability (g) Mounting Arrangement shall be of the following: (i) Engine and alternator shall be mounted on a common MS fabricated base frame with AVM pads. (ii) Base frame with integral fuel tank shall be provided with drain plug, air vent, inlet and outlet connection, level indicator and provision for cleaning. (h) Fuel Tank of capacity 12 hrs running capacity along with Fuel pipe MS C class 25mm ID with bends , flanges , valves, tees and bends. (i) Hospital grade silencer with MS pipe as designed by the OEM horizontal Exhaust pipe complete with bends and flanges of adequate length not less than 10 mtr. along with thermal insulation on horizontal pipe with Mineral Wool/ Asbestos Rope 50 mm thick wire mesh and 26 gauge aluminium cladding (12"). (j) Control/ service cables shall be of 4c x 2.5 sqmm, 24 c x 2.5 sqmm , 2 c x 2.5 sqmm, and 8c x 0.75 sqmm shielded control cables, PVC insulated copper armoured, control panel for auxillaries with starters for pumps,heaters etc
(k) RCC foundation with necessary earth work, PCC 1:4:8 type D-2 (40mm graded stone aggregate) as in foundation, filling and mass concrete and RCC M-30 (20 mm graded aggregate) as in foundations, plinth beam along with necessary form work/ TMT bars of 10mm dia and over cut to length bend to shape required including cranking, bending, spirally for hooping for columns, hooking ends and bidning with and including MS wire (annealed) not less than 0.9mm dia securing with clips and 10 mm thick plastering on fair faces of brick work or concrete surface in CM (1:6) finished even and smooth without using extra cement and sand filling in layers around the foundation including watering and consolidation as per OEM dimensions. (l) Acoustic Enclosure shall comprise of the following:- (i) Specially designed to meet stringent MoEF/ CPCB norms of 75 dBA @ 1mtr at 75% load under free field conditions (ii) The Acoustic Enclosure as per CPCB Norms shall be made of CRCA sheets in Munselgreen shade and a structural/ sheet metal base frame painted in black or any other standard colour as specified by the OEM (iii) High quality noise absorbant and fire-retardant gradeacoustic insulation material (P.U. Foam) complying to IS8183 designed to have optimum serviceability (iv) Air inlet louvers specially designed to operate at rated load, made on special purpose CNC machines for consistency inquality and workmanship (v) 11 tank pretreatment process and UV resistant powdercoating of all parts to withstand extreme environment, use of special hardware for longer life, flush styling - no projections, fluid drains for lube oil and fuel, fuel filling arrangement inside the enclosure
Note: (i) Rate quoted shall include the necessary T&P, RCC foundation, structural works required to support the acessoriess of DG set such as AMF panels, control cables, radiators/ cooling tower, exhaust mufflers and water circualtion system/ cooling system (ii) Rate quoted shall include the cost of all fuel (high speed diesel), lubes and coolant required to carry out the no load and full load test of not less than 24 hrs as directed by the Accepting Officer. (iii) Rate quoted includes the cost of B check for the DG set such as replacement of lube oil, oil/ fuel filters/ belts, O rings consumables after the test run of the DG set during the warranty period first 250 hrs/ 1 st year whichever is earlier after the date of commissioning
Suppy, installation, testing, commissioning, putting into operation and final testing of automatic lift of 8 passengers capacity (544 kg) complete in the shaft well and pit constructed including automatic rescue device (ARD), all standard equipments, accessories and control equipments as per manufacturer design, conforming to NBC/ local by laws and fulfilling the following requirements complete all as specified and directed:
(xix) Intercom system: Battery operated Intercom system in lift car,machine room and ground floor/ control room (xx) Emergency alarm: Battery operated alarm bell system in lift car and control room/ ground floor (xxi) All car panel buttons and all floor switches must be with brail language as per lift act. (xxii) Audio visual indication in the lift car showing overloading shall be provided such that doors are kept open till excess load removed. (xxiii) Spring buffer/hydraulic buffers shall be provided. (xxiv) Mechanical over speed governor, door key holes in the floor doors shall be provided. (xxv) Lift machine hoisting arrangement in the lift machine room and monkey ladder for lift pit should be provided by the lift agency, along with the other steel structure works, foundations for the machines etc. (xxvi) In the hoist way fascia plate shall be provided. (xxvii) Permanent writing in the lift machine room and lift well with proper no. of light point, with fixtures, exhaust fan, plug point and 3 phase 440V power supply shall be made available by the department in the lift shaft, machine room or at desired level (xxviii) Car top safety barricade shall be provided (xxix) ARD (Automatic Rescue Device): Solid state inbuilt automatic rescue device (ARD) for automatic rescue of passengers trapped in the lift car in between floors in the event of power failure. Automatic operation and immediate action in the event of mains failure capable to move the lift to the nearest landing, opens the automatic door of the lift car and floor. Sealed maintenance free battery backup with automatic charging unit and auto changeover device on main failure
Note for item No. 53:- Lift of 8 passenger capacity is to be used as passenger lift and as firemen lift to be effective in fire fighting operation. The firemen lift shall have the following requirements. (i) The firemen's lift may be used by the occupants in normal times. (ii) The firemen's lift shall be provided with a firemen switch. The switch shall be a two position (ON/OFF) switch fixed at the evacuation floor (Normally main entrance floor) for enabling the lift to be put into firemen's mode. The switch shall be situated in a glass fronted box with suitable level and fixed adjacent to the lift at the entrance level. When the switch is on, landing call points shall become inoperative and the lift shall be on car control only or on a priority control device. When the switch is off, the lift will return to normal working. (iii) The firemen's lift shall be provided with an audio and visual signal in car. (iv) The firemen's lift shall have a floor area of minimum 1.43 sqm. It shall have loading capacity of not less than 544kg (8 person lift). (v) The firemen's lift shall be provided with power operated (automatic) doors of minimum 0.8 mtr width. (vi) The speed of firemen's lift shall be 1 m/s or more such that it can reach the top floor from main floor/ firefighter access level within 1 minute incase of building zoned, the firemen's lift shall operate from the lowest served landing to the top most served landing in 1 min. (vii)The words "Firemen lift" shall be conspicuously displayed in fluorecent paint on the lift landing (viii) All other operation requirements of firemen's lift
All as per item No. 53 above but lift of 13 passengers capacity (884 kg)
Suppyling, installing, testing and commissioning of factory made Indoor type LT cubical panel board suitable for operation on 415 volts, 3 phase, 4 wire 50Hz supply system 65cmx65cmx40cm inlcluding bus bar chamber in centre (vertically) and cable alley either side, outer shell shall be made out of 2 mm thick CRCA sheet including painting with synthetic enemal paint duly vermin proof, CPRI approved with colour code PVC sleeves for bus bar, front opend with locking arrangement, closed bus bar chamber, angle iron 50mm x 50mm x 6mm for skeleton and support emebeded in concrete foundation comprising of following accesories:-
FIRE FIGHTING SYSTEM
Material and labour for 1100 Volts grade 3 core, 6 mm² copper conductor, XLPE armoured cable conforming to IS 7098-1: 1988, having stranded aluminium compact shaped conductors as per CI. 2 of IS 8130: 1984, PVC inner sheath, single armouring of galvanised steel strip/ wire and PVC Type ST-2 outer sheath conforming to IS 5831-1984, icluding necessary clamping/ dressing with cable ties and termination complete all as specified and directed.
Supply and fix PN 1.6 rated air vent valve having brass body, cover, adopter, disc assembly and cap, stainless steel strainer, plastic float and 25 mm screwed threaded ends suitable for maximum operating temperature 100 ˚C installed on all high points in the water piping system to automatically remove the trapped air with necessary accesories complete all as specified and directed. Make: Advance, Hindustan, L&T, Leader, Venus, Zoloto or equivalent
Supply and fix orifice plate made out of 6 mm thick SS 304 with orifice of required size to be fitted between flange and landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete all as specified and directed. Make: Newage, AAAG, Minimax, WIKA
Supply and fix CL#150 rated two-piece design 25 mm NB cast steel (CS) straight pattern ball valve, conforming to IS 9890: 1981 and tested as per BS 6755-1, having cast iron body, stainless steel AISI 304 ball, renewable PTFE seat and gland packing, CS fastners and lever having screwed/ socket weld end connection with accessories complete all as specified and directed. Make: Advance, Hindustan, L&T, Leader, Venus, Zoloto or equivalent
Material and labour for low smoke zero halogen (LS0H) flame retardant fire alarm cable 2 core, 1.5 mm², conforming to BS 7629-1, BS 6387 and BS EN 50200 and rated for 500 V, drawn through concealed PVC conduit and having plain annealed stranded copper conductor with primary insulation of glass mica fire resistant tape and secondary insulation of high performance silicone rubber, earth/ drain wire of annealed tinned copper, electrostatic screen of aluminium fire barrier and type LTS3 outer sheath conforming to BS 7655, suitable for operating temperature range -30 ˚C to +70 ˚C and minimum bending radius being 6 times the overall cable diameter, RED in colour, including laying, termination and ferruling complete all as specified and directed. Make: RR Kabel, Polycab, Havells or equivalent
All as per item No. 62 above but for cable of 2 core, 2.5 mm² for supply to hooter/ strobe complete all as specified and directed.
Supply, installation, testing and commissioning of FM approved UL listed (fire fighter's) addressable telephone jack mounted to a single-gang electrical back box with suitable interface module for two way communication with the Central Fire Fighter Telephone Console complete all as specified and directed. Make: Notifier FPJ + FCM-1 or equivalent model of JC, Esser
Supply, installation, testing and commissioning of FM approved UL listed Fire Fighter's Telephone Handset for two way communication with the Central Fire Fighter Telephone Console complete all as specified and directed. Make: Notifier FHS or equivalent model of JC, Esser
Supply and fix 4 kg capacity dry chemical powder (ABC) type fire extinguisher (1 No. at entry/ exit of each floor) conforming to IS 15683: 2006, with initial filling in brand new cylinder with powder coated finish, fitted in gunmetal union, high pressure CO2 gas cartridge, discharge hose, wall mounting bracket/ floor trolley mounting accessories along with suitable signage, etc. complete all as specified and directed. Make: Kanex, Minimax, Aim-EX, Safeguard, Coffco, Variex
Supply and fix 3 kg light-weight squeeze grip CO2 type fire extinguisher, conforming to IS 15683: 2006, with CO2 gas filled in brand new seamless cylinder with powder coated finish, made out of Manganese steel with wheel type valve, discharge nozzle, bend and horn, wall mounting bracket/ floor trolley mounting accessories along with suitable signage complete all as specified and directed with the following specifications: (2 Nos. at entry/ exit of each floor & 1 No in lift machine room) (i) Operating pressure: 10 to 15 Bars (ii) Operating temperature: -30 ˚C to 55 ˚C (iii) Performance criteria: Discharge time not less than 45 sec, throw not less than 4 metres (iv) Hydro test and burst pressure test: shall pass hydro test pressure of 35 Bars, 2.5 minutes and withstand a burst pressure of 55 Bar Make: Kanex, Minimax, Aim-EX, Safeguard, Coffco, Variex
Supply and fix 9 litre mechanical foam type fire extinguisher (in parking area), conforming to IS 15683: 2006, with initial filling in brand new cylinder with powder coated finish, fitted with gunmetal union, high pressure CO2 gas cartridge, hose and ABS type branch pipe and wall mounting bracket/ floor trolley mounting accessories along with suitable signage complete all as specified and directedwith the following specifications: (In Parking area) (i) Test pressure: 250 kgf/sqcm (ii) Operating temperature: -30 ˚C to 55 ˚C (iii) Locking pin and wire seal should be provided to indicate that the extnguisher has not been used (iv) Every extinguisher should be supplied with an operating manual Make: Kanex, Minimax, Aim-EX, Safeguard, Coffco, Variex
Supply and fix 9 kg capacity dry chemical powder (ABC) type fire extinguisher (1 No. at entry/ exit of each floor), conforming to IS 15683: 2006, with initial filling in brand new cylinder with powder coated finish, fitted in gunmetal union, high pressure CO2 gas cartridge, discharge hose, wall mounting bracket/ floor trolley mounting accessories along with suitable signage, etc. complete all as specified and directed. Make: Kanex, Minimax, Aim-EX, Safeguard, coffco, Variex
Supply and fix galvanized mild steel fire bucket (filled with dry sand) conforming to IS 2546: 1974 round bottom type enamel painted, white inside and red outside and letters "FIRE" in black outside and handle with mounting bracket complete all as specified and directed. Make: Star safety solution, Mark safety appliances
Supply and fix signage of size 300 mm X 150 mm reading "EXIT" in 12.5 mm block letters in green and white background, self illuminated, properly spaced to provide good legibility located directly in corridor near to each staircase and squarely attached to the wall or partition in a way that the top of the sign is not above 2 m from the finished floor level complete all as specified and directed. Note: The light shall emit the maximum light required even during the electricity supply or in black out period with high energy efficiency and shall be manufactured using superior quality aluminium extrusion body raw material. It shall be suface mounted or hanging type of matt black/ snow white finish after phosphochromate treatment and of wattage 5 Watt. Make: Variex, Mr safe, Matrix sign lab
Supply and fix signage of size 500 mm X 500 mm, indicating the "Floor Number" in bold type and at 75 mm high numerals in red and white background, made out of 3 mm thick opaque PVC foam board with computer cut, PVC non-reflective self adhesive vinyl painted foam board, posted and maintained within each stair enclosure on every floor, securely attached to the stair side of the door in a way that the bottom of the sign is not above 1.5 m from the finished floor level complete all as specified and directed. Make: Variex, Mr safe, Matrix sign lab
Supply and fix signage of size 450 mm X 150 mm reading "FIRE EXTINGUISHER" in 12.5 mm block letters in white and red background, made out of 3 mm thick opaque PVC foam board with computer cut, PVC non-reflective self adhesive vinyl painted foam board, properly spaced to provide good legibility located directly in corridor near to each Manual call point/ Fire Extinguisher and squarely attached to the wall or partition in a way that the top of the sign is not above 2 m from the finished floor level complete all as specified and directed. Make: Variex, Mr safe, Matrix sign lab
Supply and fix signage of size 150 mm X 600 mm, posted and maintained at each lift landing and on the side of the stairway door from which egress is to be made on every floor, indicating the "STAIRCASE" by an alphabetical letter in bold type and at 75 mm high letters in red and white background, made out of 3 mm thick opaque PVC foam board with computer cut, PVC non-reflective self adhesive vinyl painted foam board, securely attached to the side of the stairway door from which egress is to be made in a way that the bottom of the sign is not above 1.5 m from the finished floor level complete all as specified and directed. Make: Variex, Mr safe, Matrix sign lab
NOTE : Amount of credit of Rs. 1,25,08,770.00 for retrieved materials is mentioned in schedule of credit on Srl Page No. 66(R) of tender documents in pdf form which will be deducted offline while acceptance of tender.
MC Gandhi and Sons
Vraj and Vaj Construction
SOOD ASSOCIATES PVT LTD
SANKALP INFRACON
M/s Matadeen Ramchandra Agarwal
SHRIPATI INFRASTRUCTURES PVT LTD
MUKESH CONSTRUCTION CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid