GE UTILITY PLANT AND MACHINERY DELHI CANTT-10
GE UTILITY PLANT AND MACHINERY KIRBY PLACE DELHI CANTT-10
REPAIR/REPLACEMENT OF AUTOMATIC FIRE ALARM CUM DETECTION SYSTEM IN DIPAC, HQ TG EME, CICP, CVD, PMEG, CAMS, DGIS, CIDSS, MANEKSHAW CENTER AND SIGNAL ENCLAVE UNDER GE UTILITY PLANT AND MACHINERY DELHI CANTT-10
2021_MES_492036_1
GE(U)/PM/D-52/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
334 days
DELHI CANTT
MES contractor enlisted under class D category c(vi) having deposited standing security of Rs 100000 with department. Contractor not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category.
6 documents required · 6 mandatory
₹500
GE UTILITY PLANT AND MACHINERY DELHI CANTT-10
₹60,180
Yes
15 Jan 2022
2 Dec 2021
3 Jan 2022
2 Dec 2021
1 Jan 2022
18 Dec 2021
Amount
Section-I
Disconnecting and taking down carefully old unserviceable main control panel with all accessories, wiring etc, and supply, fixing, testing and commissioning of 6 Zone Fire Alarm Panel with Advanced Micro controller based 16X2 Character LCD display. Zone wise fire,open,short LED indicators, testing facility. Trickle & fast charging facility. reset, alarm cancel, lamp test and control etc. compatible with any make smoke and heat detectors. RS-485 Communication for Repeater & Mimic Panels. Power supply 230 V AC , 50 Hz / 24 V DC, operating voltage 24 V DC, normal loop voltage 23.20 V DC, E.O.L. 4K7 all other connected accessories complete all as specified and directed by Engr-in- Charge. (Make: EDWARD/ GST/ APPOLO/HONEYWELL/SYSTEM SENSOR/AGNI.)
-ditto- all as per srl item No 1.01 here-in-before but for 08 Zone complete all as specified and directed by Engr-in- Charge. (Make: EDWARD/ GST/ APPOLO/HONEYWELL/SYSTEM SENSOR/AGNI.)
-ditto- all as per srl item No 1.01 here-in-before but for 10 Zone complete all as specified and directed by Engr-in- Charge. (Make: EDWARD/ GST/ APPOLO/HONEYWELL/SYSTEM SENSOR/AGNI.)
-ditto- all as per srl item No 1.01 here-in-before but for 12 Zone complete all as specified and directed by Engr-in- Charge. (Make: EDWARD/ GST/ APPOLO/HONEYWELL/SYSTEM SENSOR/AGNI.)
-ditto- all as per srl item No 1.01 here-in-before but for 20 Zone complete all as specified and directed by Engr-in- Charge. (Make: EDWARD/ GST/ APPOLO/HONEYWELL/SYSTEM SENSOR/AGNI.) Notes for item No. 1.01 to 1.05:- (i) Material for repair/ replacement shall be supplied by the contractor and rates quoted shall deemed to be included with these items . (ii) Cost for minor materials such as nuts, bolts, screws inluding ICs/rectifiers/ LED, etc and internal wiring of control panel are deemed to be included in the quoted rates.
Taking down carefully of old unserviceable fire alarm control panel and repair the defective parts of the panel as per existing size with transporting the panel to the contractors workshop and return back after necessary repair including testing complete and refixing the same in existing position complete all specified and as directed by Engineer-in-Charge. Note :- (i) Spares parts if any required shall be included with the quoted rate. (ii) The rates quoted by the contractor shall deemed to be included transportation cost from site to contractor's repair workshop and back.
Section-II
Inspection, checking, cleaning, testing and commissioning of fire alarm cum fire detection system complete including fire detectors, smoke detectors, heat detectors, response indicators, wiring etc. through trained/experianced technician of OEM, the system and carry out planned maintenance in systematic and controlled manner at DIPAC area complete except new server room all as specified and directed by Engineer-in-charge.
-ditto- all as per Sr item No 2.01 above but for DGIS.
-ditto- all as per Sr item No 2.01 above but for CIDSS.
-ditto- all as per Sr item No 2.01 above but for CICP & COD.
-ditto- all as per Sr item No 2.01 above but for CAM.
-ditto- all as per Sr item No 2.01 above but for Signal Enclave.
-ditto- all as per srl item No 2.01 above but for Manekshaw Center.
Notes for Section- II (Serial item No. 2.01 to 2.07) :- (a) Fire Alarm control panel:- These shall be kept clean by checking for its controls, indicating equipment’s system and all operations/fault indicators including checking of panel circuits for its healthiness and including of healthy battery/UPS/battery charger system. (b) Smoke Detectors & Fire Detectors: - All smoke/fire detectors shall be removing dust/dirt accumulated on them due to local ambient conditions. These shall be tested & cleaned once in a quarterly and report shall be maintained as directed by Engineer-in-Charge duly signed by user and concerned JE/Engineer-in-charge. (c) Response Indicators, Manual Call Point and Hooter: All items which are installed inside a cabin, room or above ceiling shall be tested by actuating the particular detectors every quarterly so as to ensure proper functioning of indicator. (d) Wiring and cables:Complete wiring shall be inspected jointly by contractor, MES rep and users so that structure or occupancy changes doesn't damage the cable/wiring/trigger device (Manual call points smoke heat ionization detector etc) (e) During attending complaint and quarterly maintenance check any spares/items required for replacemnet will done by the technician of OEM (i.e detectors, panels, response indicators, hooters wiring, battery) (f) Quarterly maintenance schedule submit by the contracor to the Engineer-in-Charge for his approval before going to the quarterly check.
(g) Deployed Technician/mechanic fully equiped with necessary tools and plants are deemed to be included in the quoted rate. (h) Arrangement of testing equipment provided by the contractor deemed to be included in quoted rates. (i) The mechanic should also be in possesion of mobile and two wheeler for communication and mobility. (j) The contractor deemed to have visited the site and seen the scope of work before quoting the rates. (l) Quarterly inspection test report will be submitted to deptt duly signed by user/ Engr-in-Charge. (m) Mock drill will be conducted once in quarterly in presence of user after completion of cleaning and testing. (n) Adequate manpower shall be deployed at site to carried out for quarterly maintenance check as per CA provision. (o) All the work mentioned in notes above are deemed to be included in the quoted rates. (p) The rates for making necessary arrangement of scaffaolding/ ladders is deemed to be included in the quoted rates. (q) Any damage to smoke and fire detection system during maintenance shall be repaired by the contractor at his own cost.
Section-III
Checking and attending day to day complaints by means of finding the faults only related to fire alarm, detectors, hooters, response indicators, wiring and all other accessories and fixtures maintained by the department complete all as specified and directed. NOTE :- (i) The rate of this item are included for attending of complaints only. (ii) Taking down of unserviceable materials and fixing of new materials will be measured and paid seperately under relevent items as mentioned in Section-IV here-in-after. (iii) Complaints shall be attend any time from user/MES rep without fail, failing which recovery of rate Rs 1000/- per complaint shall be effected from the RARs/FB. (iv) Minor materials such as PVC wire of any size as per requirement upto 1.0 mtr length, thimble, electric tape, fixing accessories, etc shall be deemed to be included in the quoted rate of this itmes. (v) The complaints shall be attend and defects shall be rectified within 08 Hrs commencing from date and time of notifing the complaint, failing which a penauly Rs 1000/ per complaint shall be leived/imposed on the contractor and recovery shall be made from his dues. (vi) Contractor shall be arrange suitable T&P incl necessary ladder and scaffolding for approach and safety measures to make it functional complete all as specified and directed. The rates for which are deemed to be included in the quoted rate.
(vii) Contractor or his rep will report daily at 0900 Hrs at complaint cell/MES Office for collection of complaint from the concerned JE E/M / Engr-in -Charge, in case after checking, attending and find the defects, if it is not possible to be rectify the defects within 08 Hrs, the fact shall be brought to the notice of Engr-In-Charge by the contractor/his rep immediately. If Engr-In-Charge satisfied with contractors view, no recovery will made on this account, descretion of Engr-In-Charge shall be final and binding. (ix) The electrician/ mechanic should be in possession of mobile and two wheeler for ease of communication and mobility. (x) The contractor will maintain complaint docket/complaint slip for each complaint. After rectification of fault/complaint on complaint slip duly signed by JE/MES rep and the same will be enclosed with RAR/ Final Bills. (xi) The rates to be inclusive of note no. (i) to (x) in the quoted rate.
Section-IV
Supply and fixinig of smoke detector, optical type low current draw, wide operating voltage 8 to 30 VDC, Bi-colour LED detector status indicator, Automatic drift compensation, tested and approved to EN54 - 7:2000 (Amendment 1) including taking down old unserviceable one complete all as specified and directed by Engineer-in-charge. (Make: APPOLO / EDWARD / SEIMENS/HONEYWELL/SYSTEM SENSOR).
Supply and fixing of heat detector, optical type low current draw, wide operating voltage 8 to 30 VDC, Bi-colour LED detector status indicator, Automatic drift compensation, tested and approved to EN54 - 7:2000 (Amendment 1) including taking down old unserviceable one complete all as specified and directed by Engineer-in-charge. (Make: APPOLO / EDWARD / SEIMENS/HONEYWELL/SYSTEM SENSOR).
Supply and fixing of Multi Detector, optical type low current draw, wide operating voltage 8 to 30 VDC, Bi-colour LED detector status indicator, Automatic drift compensation, tested and approved to EN54 - 7:2000 (Amendment 1) including taking down old unserviceable one complete all as specified and directed by Engineer-in-charge. (Make: APPOLO / EDWARD / SEIMENS/HONEYWELL).
Supply and fixing of response indicators with MS Box 16 SWG and plastic cover including taking down old unserviceable one complete all as specified and directed by Engineer-in-charge. (Make: APPOLO / EDWARD / SEIMENS/AGNI).
Supply and fixing of Manual Call Point with hammer and chain, as per IS:2189. SS chain , hammer & blinking, power I/P 24 V DC, MS Sheet, 750 gm., dimesions (mm) 120 X 90 X 55. Colour - Red including taking down old unserviceable one complete all as specified and directed by Engineer-in-charge. (Make: APPOLO / EDWARD / SEIMENS/HONEYWELL/AGNI)
Supply and fixing of Electronic Hooter, Hi-Intensive sound (80 to 100 db), tested by ERTL as per IS:2189, Power I/P 100 V AC or 24 V DC, Sound O/P 100dB, MS sheet. weight 1.2 Kg, dimensions (mm) 130 X 180 X 80, Colour Red, Speaker 4 watt including taking down old unserviceable one complete all as specified and directed by Engineer-in-charge. (Make:- ASES/Philips/Bajaj)
Supply and fixing of maintanance free battery 7 AH, 12 Volts with 8 Hours backup and 12 months warranty including taking down old unserviceable one complete all as specified and directed by Engineer-in-charge. (Make:- EXIDE/ AMARON/ STANDARD FURKKAVA)
Supply and fixing of PVC conduit pipe medium grade size of 25mm including taking down old unserviceable one complete all as specified and directed by Engineer-in-charge. (Make- Kalinga/ Polycab/Finolex/ Havells/ Anchor).
Supply and fixing of multi-stranded copper conductor cable 1.5 Sq. mm nominal cross-sectional area, two core, PVC insulated and unsheathed FRLSH cable 1100 volts grade for sub main wiring including taking down old unserviceable one complete all as specified and directed by Engineer-in-charge. (Make- Havells/Polycab/Finolex/ RR Kabel)
Supply, fixing, commissioning and testing of Microprocessor based 6 loop capacity , Networkable analogue addressable type fire alarm control panel with 640 character LCD display. The panel should be equipped with sufficient numbers of loop with 20% spare capacity with each loop shall have a capacity of minimum 159 detectors and 159 analog addressable devices in one loop. Four access levels, capable of taking Flash Scan devices, flash EPROM sufficient numbers of programmable relay controls for controlling AHUs, pressurization fans, ventilation fans at fire pump room, monitoring of fire sprinkler and fire hydrant pump, 240 volts AC power supply, automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and then be capable of operating the system for 2 hours during an emergency conditions as required including taking down old unserviceable one complete all as specified and directed by Engineer-in-charge. (UL 9th Edition Approved) (Make - NOTIFIER/CPU2-3030D/WITH 6 LOOP/WITH NCM-W)
Material and labour for rectification, maintenance of addressable zones, searching the faults, up/down loading software of main control panel at Manekshaw center and reprogramming entire system and testing by authorized Technical Engineer of OEM complete all as directed by Engr-in-charge. and including Inspection, testing and commissioning of complete fire alarm system installed done by authrized OEM of Honywell manufacturer only all as required complete all as specified and directed by Engineer-in-charge.
Supply, fixing, commissioning and testing of automatic Floating Sensitivity type Analog addressable Acclimate Photo thermal smoke detector with mounting based LED, Address Switch from 01-159 , to programme the detectors, complete as required. (In Changing Environment Area) ul- 7th edition including taking down old unserviceable one complete all as specified and directed by Engineer-in-charge. (Make: - NOTIFIER/ GST/APPOLO/ EDWARD/HONYWELL).
Supply, fixing, commissioning and testing of analog addressable Rate of Rise Cum Fixed temperature detector with mounting based LED, Address Switch from 01-159 , to programme the detectors complete as required. Ul- 7th edition including taking down old unserviceable one complete all as specified and directed by Engineer-in-charge. (Make: - NOTIFIER/ GST/APPOLO/ EDWARD/HONYWELL).
Supply,fixing,testing and commissioning of addressable type fault for isolating module shorted, dewired and loose circuits between two successive fault isolators with automatic resetting arrangement (base Model) including taking down old unserviceable one complete all as specified and directed by Engineer-in-charge. (Make: - NOTIFIER GST/APPOLO/ EDWARD/HONYWELL).
Supply and fixing of addressable control modules for Hooters / Sounders / Strobes etc. including taking down old unserviceable one complete all as specified and directed by Engineer-in-charge. (Make : - NOTIFIER/ GST/APPOLO/ EDWARD/HONYWELL).
Supply and fixing of Strobe Lights Cum Hooter with 110 cd. The strobes shall be synchronized for better evacuation including taking down old unserviceable one complete all as specified and directed by Engineer-in-charge. (Make:- NOTIFIER/ GST/APPOLO/ EDWARD/HONYWELL).
Supply and fixing of manual call point including taking down old unserviceable one complete all as specified and directed by Engineer-in-charge. (Make: - NOTIFIER/ GST/APPOLO/ EDWARD/HONYWELL).
SANWARIYA ENTERPRISES
Continental Engineers and contractors
Rajindera Enterprises
FIRE PROTECTION SYSTEM
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .