Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.4 LAccepted-AOC H NO 400 STREET NO 1 SAIN GHAR PATHANKOT GURDASPUR PUNJAB 145001 | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC being lowest L1 | |
| 2 | L2₹7.3 L+₹45,418.60 (6.61%)Rejected-Finance HOUSE NO 66 GALI NO 3 ARJUN NAGAR PATHANKOT 145001 PB | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-Finance OTHER THAN LOWEST L1 | |
| 3 | L3₹7.6 L+₹73,898.60 (10.8%)Rejected-Finance 225 NAROT COLONY MODEL TOWN PATHANKOT PB 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L3 | Rejected-Finance OTHER THAN LOWEST L1 | |
| 4 | L4₹7.8 L+₹96,033.60 (14.0%)Rejected-Finance B XXIII 56 A PREM NAGAR SAINGARGH PATHANKOT 145001 PUNJAB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L4 | Rejected-Finance OTHER THAN LOWEST L1 | |
| 5 | L5₹8.9 L+₹2.0 L (29.3%)Rejected-Finance 1ST FLOOR GURJEET MARKET DHANGU ROAD | L5 | Rejected-Finance OTHER THAN LOWEST L1 |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
3 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) PATHANKOT
GE (AF) PATHANKOT-145001
REPAIR TO MAINT OF FANS, METER AND MISC ITEMS AT AIR FORCE STATION PATHANKOT.
2021_MES_419135_1
GE/PAF-60/2020-21
Open Tender
Support/Maintenance Service
Item Rate
180 days
GE (AF) PATHANKOT
As per NIT
8 documents required · 8 mandatory
₹500
GE (AF) PATHANKOT
₹20,000
Yes
21 May 2021
4 Feb 2021
5 Mar 2021
4 Feb 2021
3 Mar 2021
17 Feb 2021
60 days
Amount
Taking down carefully aluminum/copper point wiring (light fan socket or power) complete with fitting such as switches, sockets, bell, lights fittings, ceiling rose, holder, regulators, MCB DB, MCB'S, electric meter,meter box & main switch from control board and making good disturbed surfaces of walls, floor to match with existing specification complete all as specified & directed by Engineer-in-Charge.
Point wiring for one light point/fan point controlled by one switch with 1.5 sqmm Unilay- FRLS insulated unsheathed copper conductor single core multi strand flexible cable and 1.5 sqmm Unilay - FRLS nsulated unsheathed copper conductor single core cable (green color) as earth lead in and including concealed non metalic rigid PVC conduit 2mm thickness with all fittings (ISI Marked) controlled by one switch including CI/MS sunk box of required size, & as directed by Engr in Charge & 3mm thick plastic laminated sheet, including cutting chases to wall making good the disturbed surfaces to match with the existing specification complete all as specified & directed by Engineer-in-Charge.
Switch piano flush button single pole one way 5 amps 240 volts complete all as specified & directed by Engineer-in-Charge.
Ceiling rose surface bakelite 2 to 3 terminals complete all as specified & directed by Engineer-in-Charge.
Energy saving new generation 10 W LED bulk head luminaire with opal diffuser watt suitable for 10 W LED complete with LED lamp including connecting electricaly to ceiling rose using cord flexible 3 core PVC insulated over all sheathed with flexible copper conductor of size 0.75 sqmm complete all as specified & directed by Engineer-in-Charge.
Fan regulator electronic, step type hum free suitable to control speed of fan from 0 to 100% and connecting electrically complete all as specified & directed by Engineer-in-Charge.
Sheet metal enclosure MCB distribution board. Single pole & neutral 240 volts 8 way with IP-43 IK-09 protection double door complete with appropriate size bus bar and insulated neutral bar , earth bar ,top & botttom removable gland plate with knockouts fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified & directed by Engineer-in-Charge.
MCB single pole 240 volts 5 to 30 amps as per site requirment , with rupturing capacity 10 KA as per IS-8828-1996 (IEC-60898), biconnect upper and lower terminals , integrated label holder to ensure circuit identification, complete all as specified & directed by Engineer-in-Charge.
MCB single pole and neutral 240 volts up to 40 Amps as per site requirment , with rupturing capacity 10 KA biconnect upper and lower terminals , integrated label holder to ensure circuit identification, complete all as specified & directed by Engineer-in-Charge.
Bus bar chambers factory febricated 300 mm long iron clad with 2 Nos 100 amp rated Aluminium strips complete fixed flush wall and making good the disturbed wall surfaces complete all as specified & directed by Engineer-in-Charge.
Concealed rigid non metallic PVC conduit of size 25 mm dia exclusive of boxes (Junction/terminal) but inclusive of all tees ,bends , elbow , reducers , bell mouth tube ends and fixing accessories such as couplers, lock nuts , saddles , pipe hook etc for telephone wire complete all as specified & directed by Engineer-in-Charge.
Sheet metal enclosures with socket plug Top and MCB single pole and neutral enclosure with a two pin and earth plug and socket complete 20 Amp capacity complete all as specified & directed by Engineer-in-Charge.
Supply and laying or fixing or passing through pipe, 1100 V grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape in service connection of size 16 Sqmm 2 core multi stranded conductor complete all as specified & directed by Engineer-in-Charge.
Dismantling the old U/S ceiling and taking out old burnt out winding including Re-Winding of AC ceiling fan motor 1200mm sweep any make/size with super enamelled copper winding wire any gauge from 0.315 mm to 0.193mm including cutting of old burnt winding. Sleeve work varnishing with `B' class insulation varnish, connection with flexible wire of appropriate size two core copper wire upto connector block qty of copper winding wire not less than 350 grms and not more than 500 grms per fan motor complete all as specified & directed by Engineer-in-Charge. Note:- (a) Motor shall be wound with machine and inside the MES complex of GE (AF) Pathankot. (b) T & P required for rewinding the ceiling fan shuold be provided by contractror in the quoted rate.
All as per item No 14 above, but 1200mm to 1400mm sweep of any make Qty of copper winding in each motor wire not less than 400 gms and not more than 650 gms complete all as specified and directed.
Capacitor AC 240 volts 4 mfd 50HZ complete all as specified & directed by Engineer-in-Charge.
Capacitor AC 240 volts 3.15 mfd 50 Hz complete all as specified & directed by Engineer-in-Charge.
Capacitor AC 240 volts 2.5 mfd 50 Hz complete all as specified & directed by Engineer-in-Charge.
Repairs to ceiling fan complete including alignment grinding to shaft, remetalling & finishing all as required and reassembling after repairs and replacement of un serviceable items under respective items all as required at site complete all as specified & directed by Engineer-in-Charge.
Ceiling fan shaft of standard size including taking out old shaft,complete all as specified & directed by Engineer-in-Charge.
Supply & fix Wall mounted Air Circulator fans 230 volts single phase oscillating 380 mm sweep suitable for wall mounting complete all as specified & directed by Engineer-in-Charge.
Supply & fix exhaust fans AC single phase plastic body 230/ 240 V of size 250 mm sweep with louver including cutting of existing wall/ surface and making good surface complete all as specified & directed by Engineer-in-Charge.
Dismantling the old U/S Ex fan and taking out old burnt out winding including Rewinding of exhaust fan/ air circulator fan/ table fan/pedestal fan motor any size, from 225 to 300 mm sweep with supper enamelled copper wire of any size ranging from 0.500mm to 0.285 mm including necessary cutting of old burnt winding wire, cleaning of slots and provision of necessary threading/sleeve work and taking out connection in lead with PVC copper wire of appropriate size upto connector block complete all as specified & directed by Engineer-in-Charge. Note:- (a) Motor shall be wound with machine and inside the MES complex of GE (AF) Pathankot. (b) T & P required for rewinding the ceiling fan shuold be provided by contractror in the quoted rate.
All as per item No 23 above, but 450mm sweep complete all as specified and directed.
Supply and fix metal louver for exhaust fan of size from 225 mm to 450mm sweep or as per sample complete all as specified & directed by Engineer-in-Charge.
Replacement of ball bearing any No suitable for ceiling fan upto 1400mm sweep complete all as specified & directed by Engineer-in-Charge.
Replacement of ball bearing for exhaust fan/pedestal fan/air circulator/table fan upto 450mm sweep complete all as specified & directed by Engineer-in-Charge.
Cleaning thoroughly Pedestal, Wall Fan, Exhaust Fan, ceiling fans 48"/56" (1200mm / 1400mm) sweep with Kerosene Oil and painting with one coat of synthetic enamelled paint including preparation of surfaces, and writing MES No after painting complete all as specified & directed by Engineer-in-Charge
Replacement of wire guard/grill suitable for pedestal/Air circulator fan upto 500mm sweep (as per sample) complete all as specified & directed by Engineer-in-Charge.
Replacement of fan blade set heavy duty suitable for pedestal/air circulator fan 400/500 mm sweep, (as per sample) complete all as specified & directed by Engineer-in-Charge.
All as per item No 30 above, but made of plastic suitable for fans upto 300mm sweep complete al as specified and directed by Engineer-in-charge.
Supply and fixing fan blade set 1200/1400mm sweep (as per sample) complete all as specified & directed by Engineer-in-Charge.
Taking down ceiling fan any size upto 1400 mm for servicing, strip opening of fan including servicing and greasing complete. Re-assembling and refixing to the same location after replacing rubber reel, fixing bolts and nuts with lock pins for complete fan including writing MES No all as required and directed by Engineer-in Charge. Testing complete after servicing and fixing for smooth and noise free operation.
Replacement of PVC insulated flexible copper conductor cable 3 core of size 0.75 sqmm cut to length as required for connection from connector block of ceiling fan to ceiling rose/connector block of wiring complete all as specified & directed by Engineer-in-Charge.
Supply and fixing for PVC sheathed copper wire single core multi strnderd FRLS of size 1.5 sq mm complete all as specified and directed by Engineer-in-Charge.
Suply and fixing lower and upper canopy of fans of ceiling fans of suitable size required at site complete all as specified and directed by Engineer-in-Charge.
Replacement of gun metal bush with suitable size, gun metal bush for ceiling fan any make, any size and sweep complete all as specified and directed by Engineer-in-Charge.
Replacement of rubber reel with nut bolts of ceiling fan with rubber reel heavy duty for hanging fan complete all as specified and directed by Engineer-in-Charge.
Replacement of connector block of ceiling fan of suitable size of approved quality complete all as specified and directed by Engineer-in-Charge.
Replacement of down rod 90 cm long for ceiling fan 1200/1400mm sweep including clamps, reel, lock nuts, split pin etc complete all as specified and directed by Engineer-in-Charge.
Replacement of down rod 60 cm long for ceiling fan 1200/1400mm sweep including clamps, reel, lock nuts, split pin etc complete all as specified and directed by Engineer-in-Charge.
Taking down existing unserviceable ceiling Fan/ exhaust fan any type and capacity with due care and setting aside for deposit to MES store and fixing new ceiling fan /exhaust fan any Cap single phase AC 230 volts 50 Hz supply including any other work if required at site and making good disturbed surfaces as it, connecting electrically to ceiling rose or connector block using PVC insulated and overall sheathed 3 core cable of size 0.75 Sqmm with flexible copper conductor complete all as specified and directed by Engineer-in-Charge. ( Ceiling fan/ exhaust fan are issued under Sch 'B' for free for fixing).
Disconnecting electrically dismantling and taking out electric energy meter any type and capacity and depositing to MES Store Yard complete including Supply and fix single phase temper proof Electric Energy meter with LCD display 240 volts 2 wire system, 10-60 amps, 50 HZ having accuracy class 1.00 as per IS-13779 complete with all standard anti temper features including logging & display of tamper data complete including sealing properly using lead seals and wires as required complete all as specified and directed by Engineer-in-Charge.
All as per item No.43 above but three phase temper proof Electric Energy meter with LCD display 415 volts 4 wire system, 80-100 amps, complete all as specified and directed by Engineer-in-Charge
Cheching of electronic energy meter single phase/three phase up to 60 Amps after disconeeting proper electric coneection from main board and refixing in same or other location incl sealing proper lead seals and wires as required complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement Meter box suitable for fixing of two meters with locking arrengement of suitable size including fixing old meter in new box complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement Meter box suitable for fixing of one meters with locking arrengement of suitable size including fixing old meter in new box complete all as specified and directed by Engineer-in-Charge.
ADVAIT CONSTRUCTION CO
M/S SHRI RAM BUILDERS
SATISH AND CO
Vijay Kumar Contractor and Engineers
M/S V K TRADERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .