| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹12.9 LAccepted-AOC 1 OPP NAGAR NIGAM KATNI MAIN ROAD KATNI MADHYA PRADESH 483501 | KATNI | MADHYA PRADESH | 483501 | 1 | Accepted-AOC Lowest bidder | |
| 2 | 2₹16.7 L+₹3.1 L (22.6%)Rejected-AOC | 2 | Rejected-AOC L2 | |
| 3 | 3₹17.4 L+₹3.8 L (28.2%)Rejected-AOC | 3 | Rejected-AOC L3 | |
| 4 | 4₹23.5 L+₹9.9 L (73.0%)Rejected-AOC | 4 | Rejected-AOC L4 |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
20 Jun 2022, 6:00 pmClosed
GE AF TUGHLAKABAD
GE AF TUGHLAKABAD SANGAM VIHAR PO NEW DELHI 110080
REPAIR/REPLACEMENT OF SWITCHGEAR, LOOPING BOX, CHANGEOVER SWITCH AND ALL OTHER CONNECTED MISC ACCESSORIES AT TECH AREA UNDER GE (AF) TUGHLAKABAD
2022_MES_524556_2
GE/TKD-12/2022-23
Open Tender
Civil Works - Others
Item Rate
180 days
GE AF TUGHLAKABAD
MES contractor enlisted having deposited Standing Security with dept. Contractors not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category
8 documents required · 8 mandatory
₹500
GE AF TUGHLAKABAD
₹50,000
Yes
4 Aug 2022
6 Jun 2022
22 Jun 2022
6 Jun 2022
20 Jun 2022
6 Jun 2022
Amount
S&F in replacement MCCB 250 Amps 3 Pole breaking capacity 50 KA, 415 V, ICS=75% of ICU Adjustable thermal and adjustable magnetic setting type with fastening elements including taking down old unserviceable MCCB complete all as specified and directed by Engr-in-charge. Make: Havells/Legrand/Standard
S&F in replacement MCCB 250 Amps 4 Pole breaking capacity 50 KA, 415 V, ICS=75% of ICU Adjustable thermal and adjustable magnetic setting type with fastening elements including taking down old unserviceable MCCB complete all as specified and directed by Engr-in-charge. Make: Havells/Legrand/Standard
S&F in replacement MCCB 200 Amps 3 Pole breaking capacity 50 KA, 415 V, ICS=75% of ICU Adjustable thermal and adjustable magnetic setting type with fastening elements including taking down old unserviceable MCCB complete all as specified and directed by Engr-in-charge. Make: Havells/Legrand/Standard
S&F in replacement MCCB 200 Amps 4 Pole breaking capacity 50 KA, 415 V, ICS=75% of ICU Adjustable thermal and adjustable magnetic setting type with fastening elements including taking down old unserviceable MCCB complete all as specified and directed by Engr-in-charge. Make: Havells/Legrand/Standard
S&F in replacement MCCB 400 Amp 3 Pole breaking capacity 36 KA, 415 V, ICS=100 % of ICU Adjustable thermal and adjustable magnetic setting type with fastening elements including taking down old unserviceable MCCB complete all as specified and directed by Engr-in-charge. Make: Havells/Legrand/Standard
S&F in replacement MCCB 400 Amps 4 Pole breaking capacity 36 KA, 415 V, ICS=100 % of ICU Adjustable thermal and adjustable magnetic setting type with fastening elements including taking down old unserviceable MCCB complete all as specified and directed by Engr-in-charge. Make: Havells/Legrand/Standard
S&F in replacement MCCB 250 Amps 3 Pole breaking capacity 36 KA, 415 V, ICS=100 % of ICU Adjustable thermal and fixed magnetic setting type with fastening elements including taking down old unserviceable MCCB complete all as specified and directed by Engr-in-charge. Make: Havells/Legrand/Standard
S&F in replacement MCCB 250 Amps 4 Pole breaking capacity 50 KA, 415 V, ICS=100 % of ICU Adjustable thermal and fixed magnetic setting type with fastening elements including taking down old unserviceable MCCB complete all as specified and directed by Engr-in-charge. Make: Havells/Legrand/Standard
S&F in replacement MCCB 200 Amps 3 Pole breaking capacity 36 KA, 415 V, ICS=100% of ICU Adjustable thermal and fixed magnetic setting type with fastening elements including taking down old unserviceable MCCB complete all as specified and directed by Engr-in-charge. Make: Havells/Legrand/Standard
S&F in replacement MCCB 200 Amps 4 Pole breaking capacity 36 KA, 415 V, ICS=100% of ICU Adjustable thermal and fixed magnetic setting type with fastening elements including taking down old unserviceable MCCB complete all as specified and directed by Engr-in-charge. Make: Havells/Legrand/Standard
S&F in replacement MCCB 250 Amps 3 Pole breaking capacity 25 KA, 415 V, ICS=75 % of ICU Adjustable thermal and adjustable magnetic setting type with fastening elements including taking down old unserviceable MCCB complete all as specified and directed by Engr-in-charge. Make: Havells/Legrand/Standard
S&F in replacement MCCB 250 Amps 4 Pole breaking capacity 25 KA, 415 V, ICS=75 % of ICU Adjustable thermal and adjustable magnetic setting type with fastening elements including taking down old unserviceable MCCB complete all as specified and directed by Engr-in-charge. Make: Havells/Legrand/Standard
S&F in replacement MCCB 200 Amps 3 Pole breaking capacity 25 KA, 415 V, ICS=75 % of ICU Adjustable thermal and adjustable magnetic setting type with fastening elements including taking down old unserviceable MCCB complete all as specified and directed by Engr-in-charge. Make: Havells/Legrand/Standard
S&F in replacement MCCB 200 Amps 4 Pole breaking capacity 25 KA, 415 V, ICS=75 % of ICU Adjustable thermal and adjustable magnetic setting type with fastening elements including taking down old unserviceable MCCB complete all as specified and directed by Engr-in-charge. Make: Havells/Legrand/Standard
S&F in replacement MCCB 125 Amps 3 Pole breaking capacity 25 KA, 415 V, ICS=75 % of ICU Adjustable thermal and fixed magnetic setting type with fastening elements including taking down old unserviceable MCCB complete all as specified and directed by Engr-in-charge. Make: Havells/Legrand/Standard
S&F in replacement MCCB 125 Amps 4 Pole breaking capacity 25 KA, 415 V, ICS=75 % of ICU Adjustable thermal and fixed magnetic setting type with fastening elements including taking down old unserviceable MCCB complete all as specified and directed by Engr-in-charge. Make: Havells/Legrand/Standard
S&F in replacement MCCB 100 Amps 3 Pole breaking capacity 25 KA, 415 V, ICS=75 % of ICU Adjustable thermal and fixed magnetic setting type with fastening elements including taking down old unserviceable MCCB complete all as specified and directed by Engr-in-charge. Make: Havells/Legrand/Standard
S&F in replacement MCCB 100 Amps 4 Pole breaking capacity 25 KA, 415 V, ICS=75 % of ICU Adjustable thermal and fixed magnetic setting type with fastening elements including taking down old unserviceable MCCB complete all as specified and directed by Engr-in-charge. Make: Havells/Legrand/Standard
S&F in replacement MCCB 63 Amps 3 Pole breaking capacity 25 KA, 415 V, ICS=75 % of ICU Adjustable thermal and fixed magnetic setting type with fastening elements including taking down old unserviceable MCCB complete all as specified and directed by Engr-in-charge. Make: Havells/Legrand/Standard
S&F in replacement MCCB 63 Amps 4 Pole breaking capacity 25 KA, 415 V, ICS=75 % of ICU Adjustable thermal and fixed magnetic setting type with fastening elements including taking down old unserviceable MCCB complete all as specified and directed by Engr-in-charge. Make: Havells/Legrand/Standard
S&F in replacement MCCB 630 Amps 3 Pole breaking capacity 50 KA, 415 V, ICS=75 % of ICU Adjustable thermal and adjustable magnetic setting type with fastening elements including taking down old unserviceable MCCB complete all as specified and directed by Engr-in-charge. Make: Havells/Legrand/Standard
S&F in replacement MCCB 630 Amps 4 Pole breaking capacity 50 KA, 415 V, ICS=75 % of ICU Adjustable thermal and adjustable magnetic setting type with fastening elements including taking down old unserviceable MCCB complete all as specified and directed by Engr-in-charge. Make: Havells/Legrand/Standard
S&F in replacement MCCB 400 Amps 3 Pole breaking capacity 50 KA, 415 V, ICS=75% of ICU Adjustable thermal and adjustable magnetic setting type with fastening elements including taking down old unserviceable MCCB complete all as specified and directed by Engr-in-charge. Make: Havells/Legrand/Standard
S&F in replacement MCCB 400 Amps 4 Pole breaking capacity 50 KA, 415 V, ICS=75 % of ICU Adjustable thermal and adjustable magnetic setting type with fastening elements including taking down old unserviceable MCCB complete all as specified and directed by Engr-in-charge. Make: Havells/Legrand/Standard
Dismantling/taking down existing burnt unserviceable on-load changeover switch from voltage stabliser and S&F on-load changeover switch 320 A, 415 Volts, 4 Pole with fastening elements complete all as specified and directed by Engr-in-charge. Make: Havells/Standard/L&T
Dismantling/taking down existing burnt unserviceable on-load changeover switch from voltage stabliser and S&F on-load changeover switch 200 A, 415 Volts, 4 Pole metal enclosure with fastening elements complete all as specified and directed by Engr-in-charge. Note for Sl item No 1 to 26:- Spreader Terminal kit to be installed in all items. The cost of spreader kit is deemed to be included in the rates quoted by contractor. Make: Havells/Standard/L&T
M/S S.K.Electricals
Surjit and Sons
LAIQ RAM VERMA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .