Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.5 LAccepted-AOC | ₹8.5 L Quoted ₹9.5 L | L1 | Accepted-AOC Being lowest |
| 2 | L2₹9.9 L+₹36,863 (3.87%)Rejected-Finance | ₹9.9 L+₹36,863 (3.87%) | L2 | Rejected-Finance Other than lowest |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
5 Dec 2023, 6:00 pmClosed
GE (AF) E/M CHAKERI KANPUR
GE(AF)EM Chakeri
REPAIR/ MAINTENANCE AND OVERHAULING OF CEILING FAN/EXHAUST FAN AND ASSOCIATED E/M WORK AT DOMESTIC AREA AT AF STATION KANPUR
2023_MES_626566_1
8676/E8
Open Tender
Civil Works
Item Rate
180 days
Area under GE(AF) EM Chakeri
As per tender document
9 documents required · 9 mandatory
₹500
GE (AF) E/M CHAKERI
₹20,000
Yes
6 Feb 2024
3 Nov 2023
11 Dec 2023
4 Nov 2023
5 Dec 2023
17 Nov 2023
Amount
Taking down carefully Ceiling fan 1200/1400 mm sweep any size any capacity any sweep including dismentling of blade down ,rod fan for recognised defects at site or deposit to store complete all as sepcified and directed. Note : (i) refixing and reconnection etc of ceiling fan due for painting /over hauling etc. shall be measured and paid separately (ii) Any damage or loss of fan during taing down shall be made good by the contractor at the own cost.
M&L for Opening up of ceiling fan for each fan assessing listing nature and details for repair /overhauling /providing new lubricating, grease in bearing/bushes, re-assembling, commissioning and testing complete providing nuts, bolts, locking bolts, blades screws, split pin, PVC connector, washers whereas Upto 4 Meters height. required and refixing in position complete all as sepcified and directed. Note:- All major rerpair such as replacement of Bush, bearing , condensor, shaft, connection wire , winding & painting will be measured & paid separately under .
All as per item no. 2 above but for above 4 Meters height.
S&F in repair of ball bearing (No 6201, 6202 & 6203) suitable for Ceiling fan 1200mm /1400mm suitable as per site requirements complete all as sepcified and directed.
M&L for removing of burnt winding from ceiling fan stator of size 1200mm/1400mm sweep and rewinding the same with equal gauge of super enameled copper winding wire, insulating paper, varnishing, connection wire of copper condutor of suitable size and testing complete incl transportation to contractor's work shop and bringing back to store complete all as specified and directed. Note : (i) M&L required for opening of ceiling fan in MES store yard and taking out the unserviceable parts i.e bush, bearing, shaft, winding if any. (ii) Old winding of the fans will be destroyed/damaged by the of contracactor in presence of MES rep before taking out the same for rewinding and only rotor is handed over for rewinding. (b) After rewinding the same complete fan to be fix in the MES Store yard by a skilled electrication and will be tested for 24 hours continious running. In case of any fault by means of any items i.e bearing , shaft or any other item the same will be repaired by the contractor without any extra cost.
M&L for scraping all foreign materials with emery paper, cleaning the body, blades, legs, frame and down rod (preparatory work) for painting ceiling fan and painting with one coat of supper enameled white paint (spray paint)/grey paint and writing of MES No. with synthetic enameled black paint for Ceiling fan 1200mm/1400mm sweep all as directed. Note: Measuremnt of fans shall be recorded duly mentioning MES/SM Number in MB.
Hanging clamp suitable for ceiling fan of size 1200/1400mm of any make complete with nuts, bolts, rubber reel and locking pin complete all as directed by Engr-in-Charge.
S&F in Replacement of gun metal bush suitable for ceiling fan as per site requirements complete
Supply & Fixing capacitor 2.5 mfd + 5%, 220/230/415 volts AC, 50 c/s .Make EPCOS/TIBCON or any other equivalent
Supply & Fixing capacitor 3.15 mfd + 5%, 220/230/415 volts AC, 50 c/s . Make EPCOS/TIBCON or any other equivalent
Supply & Fixing capacitor 4 mfd + 5%, 220/230/415 volts AC, 50 c/s .Make EPCOS / TIBCON or any other equivalent Note for ser No 09 to 11. Manufacturing date of capacitor should be current FY only.
Supply & fix PVC canopy of 1200/1400 mm sweep ceiling fan of approved make, ISI marked.
S&F down rods for ceiling fan 1200/1400mm sweep of size '750mm ' long duly painted with white synthetic enamel paint complete all as directed by Engr-in-charge
S&F down rods for ceiling fan 1200/1400mm sweep of size '900mm' long duly painted with white synthetic enamel paint complete all as directed by Engr-in-charge
S&F down rods for ceiling fan 1200/1400mm sweep of size '1200mm' long duly painted with white synthetic enamel paint complete all as directed by Engr-in-charge Note for item ser No 13 to 15 : Rate of taking down and rehaging the fan are deemed to be included in the quoted rate
S& F GI tubing 40 mm bore medium grade ISI marked for fixing on walls including PCC 1:3:6 type C-1 block 230x230x150 mm for grouting ends of pipe & all fittings for hanging of Ceiling fans complete all as directed.
M&L for fan hook made out of MS flat 50x6 mm suitably shaped to mount on 40 mm dia GI pipe including welded MS bar 10 mm dia half round shaped & necessary nuts & bolts complete all as directed.
M&L for Remetaling to worn out shaft of fan motor turning complete to obtain the standard dia of shaft for fixing standard size bearing/bushes to ceiling fan of 1200/1400mm sweep of any make complete all as specified and directed.
S&F, in replacement, electronic socket size, rotary, 5 speed step type regulator, 120-230 V white finish complete all as specified. Make : Cona/Havells/Anchor
S&F fan blade set (set of three) made out of aluminium sutaible for 1200 mm sweep ceiling fan, as per exisitng size and guage all directed by Engr-in-Charge Make : As per sample
All as per srl item No 20 here-in-before but 1400 mm sweep
Taing down carefully exhaust fan /wall fan /pedestal fan /air circulators any size any capacity any sweep for recognised defects at site or deposit to store complete all as directed by Engi-in-Charge Note : (i) refixing and reconnection etc of ceiling fan due painting /over hauling etc shall be measured and paid separately (ii) Any damage or loss of fan during taing down shall be made good by the contractor at the own cost
Opening of Exhaust fan/wall fan/Pedestal fan/ air circulator any make any size from any position at site transporating to MES store Yard & dismantling blades opening the stator and rotor of fan and providing new lubricating, grease in bearing/bushes, reassembling incl providing nuts, bolts, locking bolts, blades screws, split pin, rubber reel, PVC connector, rubber pad, washers whereas required all as directed by Engineer-in-charge. Note:- All major rerpair such as replacement of Bush, bearing , condensor, shaft, connection wire, winding & painting will be measured & paid separately under supply only items here-in-after
Refixing, connecting and testing Exhaust fan/wall fan/Pedestal fan/ air circulator any make any size from any position at site in position complete all as specified and directed.
S&F in replacement PVC insulated three core wire copper conductor 1100 Volt grade of size 0.5 Sqmm complete all as directed. Make : Plaza/Polycab/SKF
S&F in Replacement of ball bearing suitable for Exhaust fan/wall fan/pedestal fan upto 400mm sweep complete all as specified and directed. Make : Plaza/Polycab/SKF
S&F in Replacement of ball bearing suitable for Exhaust fan / pedestal fan / Air circulator 450mm to 600mm sweep of approved make.
Supply and fix in replacement of BLDC ceiling fan 1200 mm sweep, complete with down rod canopy and blades of size 1200 mm sweep, Energy efficient and with and including writing MES/SM number with black Paint in appropriate size of font letter all as specified & directed by Engineer in Charge. Make Havells. / crompton / Bajaj/ Usha/ Orient as approved by GE (Note:- Old fans will be deposited to MES)
Material and Labour for removing of burnt winding from exhaust fan/ Air Circulators/ Wall mounted fans/ pedestal fans rewinding the same with equal gauge of super enameled copper winding wire, insulating paper, varnishing and testing complete incl transportation to work shop and bringing back to store and testing for following fans :- Exhaust Fan 9” sweep.
All as per item No 29 above but Exhaust Fan 12” sweep.
All as per item No 29 above but Exhaust Fan 18” sweep
All as per item No 29 above but Wall Mounted Fan 16” sweep.
Supply and fixing the revolving mechanism of wall mounted fan suitable for 400 mm sweep or as per existing type all as per specified and directed by Eng-in-Charge
S&F in Replacement of gun metal bush suitable for pedestal fan/ exhaust fan all as per site requirements.
M&L for scraping all foreign materials with emery paper, cleaning the body, blades, legs, frame and down rod (preparatory work) for painting of exhaust fan/air circulator fan/pedestal fan and painting with one coat of supper enameled white paint (spray paint)/grey paint and writing of MES No. with capital letter of size 20 mm height and 03 mm width with synthetic enameled black paint all as directed FOR Exhaust Fan 9”/12" sweep.
All as per item No 35 above But 18 " exhaust Fan -do-
Material and Labour for making circular holes suitable for fixing of 18” sweep Exhaust fans by cutting the wall any thickness/ required circumstances for exhaust of air and including grouting of rag bolts and nuts complete including finishing of disturbed surfaces by using cement mortar 1:3 complete all as required at site and directed by the Engineer-in-Charge.
All as per item No 37 above but suitable for 12” sweep exhaust fan.
Supply and fixing in replacement of wall mounted fan blade suitable for 400 mm sweep fan as per existing complete all as directed by Engr-in-Charge.
S&F exhaust fan MS blade 12” to 15” as per existing complete all as directed by Engr-in-Charge.
S&F exhaust fan MS blade 18” to 24” as per existing complete all as directed by Engr-in-Charge.
M&L for MS front frame suitable for mounting of stays of 9" exhaust fan made out of MS Sheet not less than 1.6mm thick painted with two coat of synthetic enamelled over a coat of red oxide primer complete with neccesarry fixing accessories such as nut, bolts washers etc & fixing to wall all as per existing & site requirement as directed by Engr-in-charge incl taking down old unsv .
-do- but suitable for 12" exhaust fan -do-
-do- but suitable for 18" exhaust fan -do-
M&L for MS stay work (set of 4) suitable for 9" exhaust fan made out of not less than 20 x 3mm MS strip bent to shape complete painted with two coat of synthetic enamelled over a coat of red oxide primer complete with neccesarry fixing accessories such as nut, bolts washers etc & fixing to wall all as per existing & site requirement as directed by Engr-in-charge incl taking down old unsv .
-do- but suitable for 12" exhaust fan made out of not less than 25 x 4mm MS strip -do-
-do- but suitable for 18" exhaust fan made out of not less than 25 x 4mm MS strip -do-
M&L for circular / rectangular framed shutters suitable for 9" exhaust fan made out of MS sheet not less than 1 mm thick for frame & not less than than 0.6mm thick for shutter painted with two coat of synthetic enamelled over a coat of red oxide primer complete with neccesarry fixing accessories all as per existing & as per site requirement & directed by Engr-in-charge.
-do- but suitable for 12" exhaust fan -do-
-do- but suitable for 18" exhaust fan -do-
M&L for Remetaling to worn out shaft of fan motor turning complete to obtain the standard dia of shaft for fixing standard size bearing/bushes of exhaust fan 9/12 " size & quality as per existing all as directed by Engr-in-charge.
M&L for Remetaling to worn out shaft of fan motor turning complete to obtain the standard dia of shaft for fixing standard size bearing/bushes of exhaust fan 18 " size & quality as per existing all as directed by Engr-in-charge.
S B ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .