| 1 | L1₹4.8 CrAccepted-AOC | ₹4.8 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹5.5 Cr+₹72.7 L (15.2%)Rejected-AOC | ₹5.5 Cr+₹72.7 L (15.2%) | L2 | Rejected-AOC L2 |
| 3 | L3₹5.7 Cr+₹90.4 L (18.9%)Rejected-AOC | ₹5.7 Cr+₹90.4 L (18.9%) | L3 | Rejected-AOC L3 |
Tender Value
Refer Docs
EMD Value
₹4.6 L
Closing Date
29 Apr 2021, 6:00 pmClosed
GE (I) CAMPBELL BAY
GE (I) CAMPBELL BAY, ARMY LAND,GREAT NICOBAR, PIN-744302
COMPLETION OF INCOMPLETE WORK FOR PROVISION OF KLP ROAD, SECURITY WALL, TECHNICAL / ALLIED SERVICE FOR PROJECT SAMUDRA AT CAMPBELLBAY
2021_MES_431833_3
8412/E8
Open Tender
Civil Works
Lump-sum
610 days
CAMPBELL BAY
Please refer Tender documents.
8 documents required · 8 mandatory
₹2,000
Yes
GE (I) CAMPBELL BAY
₹4.6 L
Yes
18 May 2021
10 Apr 2021
1 May 2021
11 Apr 2021
29 Apr 2021
12 Apr 2021
Amount
GENERAL SUMMARY NOTE: Schedule ‘A’ Part I to XVI are prepriced by MES based on SSR 2004 under Ser No. 2.00 to 17.00. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only.
Lumpsum price worked out by the contractor for "BUILDING/STRUCTURES” as listed in Schedule ‘A’ Part - I, inserted by MES
Lumpsum price worked out by the tenderer for "INTERNAL WATER SUPPLY" as listed in Schedule 'A' Part-II
Lumpsum price worked out by the tenderer for "INTERNAL ELECTRIFICATION" as listed in Schedule ‘A’ Part-III
Lumpsum price worked out by the tenderer for "SITE CLEARANCE, EARTH WORK, EXCAVATION AND LAND DEVELOPMENT" as listed in Schedule ‘A’ Part-IV
Lumpsum price worked out by the tenderer for "SEWAGE DISPOSAL" as listed in Schedule ‘A’ Part-V
Lumpsum price worked out by the tenderer for "PCC RETAINING WALL" as listed in Schedule ‘A’ Part-VI
Lumpsum price worked out by the tenderer for "RCC RETAINING WALL" as listed in Schedule ‘A’ Part-VII
Lumpsum price worked out by the tenderer for "ROAD" as listed in Schedule ‘A’ Part-VIII
Lumpsum price worked out by the tenderer for "PCC FOOT PATH " as listed in Schedule ‘A’ Part-IX
Lumpsum price worked out by the tenderer for "HARD STANDING" as listed in Schedule ‘A’ Part-X
Lumpsum price worked out by the tenderer for "RCC CULVERT" as listed in Schedule ‘A’ Part-XI
Lumpsum price worked out by the tenderer for "AREA DRAINAGE" as listed in Schedule ‘A’ Part-XII
Lumpsum price worked out by the tenderer for "SECURITY WALL" as listed in Schedule ‘A’ Part-XIII
Lumpsum price worked out by the tenderer for "EXTERNAL WATER SUPPLY" as listed in Schedule ‘A’ Part-XIV
Lumpsum price worked out by the tenderer for "EXTERNAL ELECTRIFICATION" as listed in Schedule ‘A’ Part-XV
Lumpsum price worked out by the tenderer for "LIGHTING PROTECTION " as listed in Schedule ‘A’ Part-XVI
Subtotal
NOTE: Schedule ‘A’ Part - XVII is not prepriced by MES and prepriced rate indicated as 0.00 under Col.5 signifies this fact only. Bidder shall insert their rates in Green colour filled under Col-6.
A. INTERNAL ELECTRIFICATION S & F fan regulator electronic flush type suitable for ceiling fan complete all as directed and as specified of make Anchor/Leader
S & F energy Efficient tube light fitting T5 battern PCR type including lamp 1x28 Watts complete including plastic body luminaire housing all prewired with high efficiency electronic ballast complete fixed to wall/ceiling with screws or suspended by conduit dia 19mm including connection by three core flexible PVC cable with stranded copper conductor 0.75Sqmm fron ceiling rose to the connector of fitting and all as specified and directed of Make Havells cat Part No. PCR HITO2128-H or equivalent of Phillips, Bajaj & Crompton Greeves.
S & F exhaust fan 300/380mm sweep 1400 RPM suitable for working on 230 Volts, 50 Hz, AC SPN with louvers, fixing with suitable size of GI bolts duly grouted with nuts and bolts and washers and connecting up with 3 core PVC flexible stranded copper conductor cable of size 0.75sqmm from ceiling rose to the exhaust fan all as directed Make: Almonord/Crompton Greeves/Usha/Bajaj
S & F energy Efficient tube light: fitting T5 battern PCR type including lamp 2x28 Watts complete including plastic body luminaire housing all prewired with high efficiency electronic ballast complete fixed to wall/ceiling with screws or suspended by conduit dia 19mm including connection by three core flexible PVC cable with stranded copper conductor 0.75Sqmm fron ceiling rose to the connector of fitting and all as specified and directed of Make Havells cat Part No. PCR LHIT01228033 or equivalent of Phillips/Bajaj & Crompton Greeves.
S & F Flame proof and increased safety luminary bulk head type with lamp and all accessories including fixing arrangements, connecting with and including 3 core flexible cable copper bunched conductor of size 0.75 Sqmm from termination point to light fitting all as specified. MAKE: Crompton Greaves Cat No. IBF 100 (AL) lamp type 100 W GLS or equivalent in Bajaj.
S & F Integral post top lantern for famp MH DE 70W light fitting luminaire type BJODCI 1170 MH DE of Bajaj makecomplete or equivalent in Phillips/Havells
S & F modular telephone socket / jack with concealed metal box all as directed
Supply and Installing split type Air conditioner, 2 TR capacity electric driven, single phase, AC, 230 V with and including all fixing arrangements and connecting up, testing and commissioning all as directed by Engineer-in-Charge. NOTE: AC shall be of make Bluestar / Usha / Voltas / Carrier / LG.
FIRE FIGHTING M & L Fire point/stand complete all as specified and directed with and including following accessories: - (a) Fire hook - 01 No. (b) Fire beater - 01 No. (c) GI fire buckets - 04 Nos. (d) Fire stand made of 25 mm x 25 mm x 5 mm angle iron -01 No. (e) Fire extinguisher CO2 type 5 Kg capacity -01 No. (f) Fire extinguisher dry chemical powder type 5 Kg capacity - 01 No.
M&L for 3 Core 10 Sqmm LT under ground cable heavy duty 1100 Volts grade XLPE insulated armoured and PVC sheathed with aluminium conductor multistranded including cable lugs, jointing material etc., laid in trenches/ducts or fixed on wall/pole or drawn through pipes complete all as specified and directed.
M&L for 3 Core 4 Sqmm LT under ground cable heavy duty 1100 Volts grade XLPE insulated armoured and PVC sheathed with aluminium conductor multistranded including cable lugs, jointing material etc., laid in trenches/ducts or fixed on wall/pole or drawn through pipes complete all as specified and directed.
M&L for low density polyethylene pipes (LDPE) of size 50mm dia for cable protection.
S & F 1000 litres capacity corrosion resistant stainless steel water storage tank (cylindrical vertical with closed top) made out of 2mm thick stainless steel sheet hoisted and fixed in position on PCC platform including float valve, inlet/outtlet over flow connection complete all as specified and as directed.
M&L Valve chamber built in PCC 1:3:6 Type C1 solid block masonry in cement mortar (1:4) including base concrete PCC 1:4:8 mix, Type D2 100 mm thick, 200 mm thick solid block masonry wallis with solid blocks exceeding 10 Cm width, plastering with cement mortar (1:4) 15mm thick internally & externally including provision of 3.15 mm thick MS sheet cover fixed with 50 x 50 x 6 mm angle iron embedded in PCC 1:2:4 mix, type B1 coping 100 mm thick including painting to steel & iron work with two coats of synthetic enamel paint over one coat of red oxide primer and necessary earth work & excavation in any type of soil complete with locking arrangement lifting handles all as specified with following internal dimensions:- (a) 1200 mm x 1200 mm x 1200 mm
S & F 80 mm dia bore Cast iron foot valve ISI marked including flanged joint with 3 mm thick rubber gasket with necessary bolts & nut complete all as specified and as directed. Note: The unit rate quoted shall include the cost of rubber gasket, nut and bolts
EXTERNAL ELECTRICICATION S & F Air break switch, triple pole, current rating 200 amps 11000 Volts grade, vertical/horizontal type, mechanically operated mounted on and including insulators and steel frame with operating mechanism operated from ground with and including jumper connection with ACSR conductor along with PVC pipe covering with colour code between main supply and AB switch complete all as specified and directed.
S & F dropout fuse set assembly of current rating 100 amps 11000 Volts grade, complete all as specified and directed.
S & F cable route indicator, made out of 150 mm dia and 6 mm thick MS plate, duly embossed with description as "MES HT 11 KV UG CABLE", fitted to 0.50 m long angle iron of size 25 mm x 25 mm x 3 mm with bolts and nuts and painting all over with two coats of aluminium paint over one coat of red oxide primer and embedded in PCC 1:3:6 Type C1 block of size 200 mm x 200 mm x 200 mm and planted in cable trench all as specified and directed.
S & F cable route indicator, made out of 150 mm dia and 6 mm thick MS plate, duly embossed with description as "MES LT UG CABLE", fitted to 0.50 m long angle iron of size 25 mm x 25 mm x 3 mm with bolts and nuts and painting all over with two coats of aluminium paint over one coat of red oxide primer and embedded in PCC 1:3:6 Type C1 block of size 200 mm x 200 mm x 200 mm and planted in cable trench all as specified and directed.
M&L Outdoor type cable end termination (heat/cold shrinkable) suitable for 11000 Volts HT XLPE under ground cable (earthed) of size 3 core 95 Samm.
M&L Indoor type cable end termination joint (heat/cold shrinkable) suitable for 11000 Volts HT XLPE under ground cable (earthed) of size 3 core 95 Sqmm.
S&F Kiosk box of size 250mm x 150mm x 100mm made out of 3mm thick CRCA sheet with weather proof hinged doors, locking arrangement, aluminium bus bar of size 25 x 3mm fixed on insulators and 1 No, MCB 240 Volts, SP, 2.5 Amps, fixe on poles/walls with and including 25mm x 3mm MS flat iron clamps and painting with two coats of synthetic enamel paint over one coat of red oxide primer all over internally and externally complete all as specified and directed.
S&F gate light fittings HPSV 125 W complete with lamp and connecting with PVC insulated multistranded copper cables 2.5 Sqmm 2 runs from lamp fitting to junction box all as specified and as directed. Make : Havells/Philips/Bajaj/Crompton Greaves/Wipro
DEFECTIVE PORTION OF WORKS SCHEDULE 'A' PART - I for Rectification. Schedule 'A' Part I Ser Item No.1 Admin Block (D / S ) Preparing old plastered surfaces of walls and applying three coats of white washing including complete removal of existing treatment all as specified and directed
M & L Two coats of exterior acrylic emulsion paint on external surfaces of walls including complete removal of existing treatment all as specified and directed
Preparing old plastered surfaces of ceilings and applying three coats of white washing including complete removal of existing treatment all as specified and directed
Schedule 'A' Part I Ser Item No.2 MI Room (S / S ) Preparing old plastered surfaces of walls and applying three coats of white washing including complete removal of existing treatment all as specified and directed
M& L Two coats of exterior acrylic emulsion paint on external surfaces of walls including complete removal of existing treatment all as specified and directed
Preparing old plastered surfaces of ceilings and applying three coats of white washing including complete removal of existing treatment all as specified and directed
Schedule 'A' Part I Ser Item No.4 Scooter shed (S / S ) Preparing old plastered surfaces of walls and applying three coats of white washing including complete removal of existing treatment all as specified and directed
M & L Two coats of exterior acrylic emulsion paint on external surfaces of walls including complete removal of existing treatment all as specified and directed
Preparing old plastered surfaces of ceilings and applying three coats of white washing including complete removal of existing treatment all as specified and directed
Schedule 'A' Part I Ser Item No 16 Repair Bay & Garrage(S/S ) Preparing old plastered surfaces of walls and applying three coats of white washing including complete removal of existing treatment all as specified and directed
M & L Two coats of exterior acrylic emulsion paint on external surfaces of walls including complete removal of existing treatment all as specified and directed
Preparing old plastered surfaces of ceilings and applying three coats of white washing including complete removal of existing treatment all as specified and directed
Schedule 'A' Part I Ser Item No 18 Pump House No. 1 (S/S ) Preparing old plastered surfaces of walls and applying three coats of white washing including complete removal of existing treatment all as specified and directed
M & LTwo coats of exterior acrylic emulsion paint on external surfaces of walls including complete removal of existing treatment all as pecified and directed
Preparing old plastered surfaces of ceilings and applying three coats of white washing including complete removal of existing treatment all as specified and directed
Schedule 'A' Part I Ser Item No 18 Pump House No. 2 (S/S ) Preparing old plastered surfaces of walls and applying three coats of white washing including complete removal of existing treatment all as specified and directed
M & L Two coats of exterior acrylic emulsion paint on external surfaces of walls including complete removal of existing treatment all as pecified and directed
Preparing old plastered surfaces of ceilings and applying three coats of white washing including complete removal of existing treatment all as specified and directed
Schedule 'A' Part I Ser Item No 19 Generator Room & Sub Stn Preparing old plastered surfaces of walls and applying three coats of white washing including complete removal of existing treatment all as specified and directed
M & L Two coats of exterior acrylic emulsion paint on external surfaces of walls including complete removal of existing treatment all as specified and directed
Preparing old plastered surfaces of ceilings and applying three coats of white washing including complete removal of existing treatment all as specified and directed
M&L Cement concrete type C-2, 1:3:6 (40mm graded aggregate)75mm thick as in plinth protection,finished even and smooth w/o using extra cement all as specified and directed
Schedule 'A' Part I Ser Item No 24 Garrage for LMV (S/S ) Preparing old plastered surfaces of walls and applying three coats of white washing including complete removal of existing treatment all as specified and directed
M & LTwo coats of exterior acrylic emulsion paint on external surfaces of walls including complete removal of existing treatment all as specified and directed
Preparing old plastered surfaces of ceilings and applying three coats of white washing including complete removal of existing treatment all as specified and directed
SCHEDULE OF DEFECTIVE PORTION OF WORKS : Sch "A" Part- VIII (ROAD) Repair to pot holes any depth, not exc 1 sqm each including sweeping free from dust and mud or water, scoring sunken surfaces in roads, paths etc. cutting around edges to at least 25mm in depth making good by filling in screened and graded road metal, watering and well ramming ( including supply of road metal ) but making good by applying tack coat at 5 kg per 10 sq m, putting in premixed bituminous macadam, well rammed and sealed with binder 9.8 kg per 10sq m, blinded with 0.09 cu m of stone chippings, 6.3 mm size and again well rammed (including supply of premixed macadam, binder and chippings), depth of potholes exc 30 mm complete all as specified and directed by Engineer-in-charge.
Scarifying or picking gravelled, from bituminous macadam surfaces in area exc 400 sqm not exceeding 50mm deep
Rolling and consolidating formation of surfaces in cutting including watering as necessary filling in the depressions with approved earth which occurs during the process with 8 to 10 tonne power roller, consolidating to required gradient and camber all as specified.
M&L for 150mm thick (compacted thick ness) WBM, in two layers of 75mm thickness each, with granite, trap or basalt course aggregate of grading 2 (63 to 40mm size) spread rolled and consolidated with 8 to 12 tonne power roller to required gradient and camber all as specified.
M&L for preparing surfaces of water bound macadam by brushing with wire brushes for removing caked mud etc, sweeping with brooms and finally fanning the cleaned surface with gunny bags to remove all loose dirt etc and applying evenly a tack coat with and including paving bitumen at the rate of 10kg per 10 sqm complete all as specified.
M&L for premix bituminous macadom, (consolidated thickness 50mm) with binder (paving bitumen) contents at 4% by weight of total mix, laid/rolled and compacted with 8 to 12 tonne power roller to required gradient and camber complete all as specified.
M&L for preparing the black top bituminous macadam surface by brushing with wire brushes for removing caked mud etc, sweeping with brooms and finally fanning the cleaned surface with gunny bags to remove all loose dirt etc and applying evenly a tack coat with and including paving bitumen at the rate of 5kg per 10 sqm complete all as specified.
M&L for bituminous premixed carpet 2.5cm consolidated thickness with 0.34Cum of stone chipping mixed with 18.25kgs of binder (paving bitumen) per 10 sqm of surface area rolled and compacted with 8 to 12 tonne power roller to required camber and gradient complete all as specified and as directed.
M&L for laying liquid seal coat, applying evenly binder (paving bitumen) at 9.80kg per 10sqm blinding with 6.3mm size stone chipping at the rate of 0.09 cum/10sqm and rolled with 8 to 10 tonne power roller rolled to a uniform smooth surface all as specified and as directed.
M&L for formation of road side berms 75mm thick (spread thickness) on either sides of road using approved earth obtained from excavation spreading, levelling, watering and well ramming with hand roller 0.5 tonne capa city, finishing to required size and shape, gradient and camber all as specified and as directed.
SCHEDULE OF DEFECTIVE PORTION OF WORKS : SCHEDULE 'A' PART XI ( RCC CULVERT) M&L for PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete.
SCHEDULE OF DEFECTIVE PORTION OF WORKS :SCHEDULE 'A' PART -XII (AREA DRAINAGE) M&L for PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete all as specified.
SCHEDULE OF DEFECTIVE PORTION OF WORKS : SCHEDULE 'A' PART XIII (SECURITY WALL) M&L for preparing old plastered surfaces of walls and applying two coats of cement based paint over and including one coat of alkali resistant primer including complete removal of existing treatment all as pecified and directed all as specified and directed.
DEFECTIVE PORTION OF WORKS : SCHEDULE ‘A’ PART XV (EXTERNAL ELECTRIFICATION) M&L for painting of LT/HT steel tubular poles including scraping rusts, cleaning of duct, old paint applying of two coat of synthetic enamel paint over the surface complete all as specified and directed
Supply & Erecting steel tubular swaged pole type 410-SP-55 (11.0 Metre long) including cast iron base plate, finial taper plug, cap, mild steel bolts, nuts, screws including applying two coats of black bituminous paint internally and externally from bottom end of pole upto PCC coping and applying with two coats of Aluminium painting over a coat of Aluminium primer (Externally from Top of coping) including writing MES pole No with synthetic enamel paint (First Grade/quality), complete all as specified and as directed.
M & L for Cross-Arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washer, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated/directed and inclusive of one coat of Aluminium primer one under coat and one finishing coat of Aluminium paint, complete all as specified and as directed.
S&F insulator pin type porcelain, vitreous, white, brown or green including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut, 150mm height, 150mm dia for 11 KV grade, complete all as specified and as directed.
S&F lightening arrestor non linear resistor type conforming to IS-3070 (Part-3) 1993 complete, line discharge class-3, nominal discharge current 10KA (peak), 12KV rated system, voltage peak value high current implus of 4/10 micro sec, wave shape 100 KA (peak) assembly suitable for 11 KV, long duration discharge class-II with insulation level 28/75 KV and mounted on hot dip galvanized steel structure including all clamps, nuts, bolts and washers and connecting to earth with 4mm dia GI wire including removal of extg unsv one complete all as specified and directed.
SCHEDULE OF DEFECTIVE PORTION OF WORKS : SCHEDULE ‘A’ PART XVII (SPECIAL ITEM S INTERNAL ELECTRIFICATION) M&L for earthing complete including removal of old unserviceable one with galvanized steel earth plate electrode of size 60cm x 60cm x 6mm buried directly in ground (earth pit not less than 2.25 meters deep below the normal ground level) with top edge of the plate not less than 1.5 m below normal GL connected to GI earth lead wire 4mm dia by means of GI bolts, nuts, check nuts and washers and earth lead protected by 15mm dia GI pipe medium grade and connected to main distribution board/earthing test points all as shown on electrical plate No 3 of SSR Part I and all as specified including testing on completion. Note : The unit rate shall also include for excavation, earthwork in hard/dense soil, plain cement concrete 1:3:6 mix type C1 pit, 40mm thick RCC 1:2:4 mix type B1 cover reinforced with 8mm dia TMT bars @ 150 C/C both ways GI funnel with watering pipe wire mesh protection pipe for earth lead upto 7.50 m long complete in addition to item No 1 (a) to € of preamble (Notes) under sub heading earthing, specified in SSR Part II. Earth lead and protection pipe beyond 7.5m shall be measured and paid separately.
Rectification of defects, Servicing/over hauling of electric driven centrifugal pump set with 2 stage impeller (Bronze) having discharge capacity of 20 cum per hour at a head of 20 meters installed at Pump house coupled with upto 20 HP motor along with following others repairs. a) Taking out pump from its position by decoupling from motor and disconnecting all suction / delivery water connections, setting aside pump from base plate. b) Dismantling of pump complete part by part carefully, degreasing bearing and display all the parts without damaging any portion for inspection of Engineer in charge to ascertain the serviceability of existing parts c) Replacement of Gasket set and gland packing rope. d) Re assembling the pump complete with all existing serviceable partse) Re install the pump at its existing position complete etc
Dehydration and filtration of existing transformer oil of transformers capacity of ranging 320 KVA (11 KV system step down to 11/0.433 KV) on site without disturbing the power supply system with filtration machine and heating system in order to achieve di-electric strength of oil 40 KV minimum at 2.5 mm gap complete all as specified and as directed.
Supply & filling up of transformer oil conforming to IS-335 of 1993 as in topping up/replacement upto desired level of transformer oil capacity complete all as specified and as directed. Note : Dielectric strength of oil should not be less than 42 KV/cm complete all as specified and directed.(Make : GULF/POWER OIL or equivalent as approved by GE)
Overhauling of the existing step down transformer indoor type suitable for plinth mounting complete with standard accessories/fittings suitable for HT 11 KV 3 Phase and LT 433 volts 3 Phase 4 wire, copper wound with off load taping switch and variation of secondary voltage +7.5% in steps of 2.5% continuous rating of capacity 315 KVA with temp rise of 45 deg cel over and ambient of 50 deg cell max conforming to IS-2026 and equipped with and including following items :- (a) Lifting lugs/hooks for transformer and tanks. (b) Earthing terminal, rating diagram plate and conservator tank. (c) Air release device. (d) Oil filling inlet pipe with plug. (e) Drain outlet pipe with brass gate valve with dummy plug. (f) Conservator with level gauge. (g) Silica gel breather. (h) First oil fill upto appropriate level as recommended by manufacturer with fresh new oil conforming to IS-335. (j) Type of connection : delts/star. (k) Cooling : ONAN (l) Vector group : DYN 11 (m) Thermometer with pocket. (n) Type of connecting arrangement: Cable termination boxes on both HT and LT sides. (o) Buchloz relay (p) Control cable, copper, armoured from transformer to VCB for bucholz alarm & trip. (q) Explosion vent with double diaphram. (r) One extra neutral bushing on top.
S & F Kiosk of size 250 mm x 150 mm x 100mm made out of 3mm thick CRCA sheet with weather proof hinged doors, locking arrangement, aluminium bus bar of size 25 x 3mm fixed on insulators and 1 No MCB 240 volts, SP 2.5 Amps, fixed on poles/walls with and including 25mm x 3mm MS flat iron clamps and painting with two coats of synthetic enamel paint over one coat of red oxide primer all over internally and externally complete all as specified and directed.
M&L for Earthing complete with galvanised steel earth plate electrode of size 60cm X 60cm X 6mm buried directly in ground (earth pit not less that 2.25metres deep below the normal ground level) withtop edge of the plate not less than 1.5m below normal GL connected to Gl earth steep 32mmx6mm by meain job bolts, nuts,chek nuts and wahser and earthe streep protected by 40 mm dia GI pipe medium grade and connected to main distribution board/earthing test point all as show on electrical plate No 3 of SSR Part I and all as specified including testing on complition. Notes: The unit rate shall also include for excavation, earth work in hard/dense soil, plain cement concrete 1:3:6 mix, Type C1 pit,40mm thick RCC 1:2:4 mix, type B1 cover reinforced with 8mm dia TMT bars @ 150mm C/C both ways, Gl funnel with watering pipe, wire mesh, protection pipe for earth lead upto 7.50m long complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub heading earthing, specified in SSR Part ll. Earth steep and protection pipe beyond 7.5m shall be measured and paid separately.
HT 11 KV VCB suitable for 3 phase 50 Hz 11 KV supply system with short circut fault level of 250 MVA with current rating 400 Amps factory made suitable for indoor floor mounting type with copper bus bar total enclosed free standing cubical pattern painted with 2 coats of synthetic enamal paint over a coat of red oxide primer including internal wiring with suitable copper conductor cables and comprising of following:- (a) The panel shall be made out CRCA sheet of thickness not less than 2 mmthick weather and vermain proof hinged doors with locking arrangement vertical / horizontal with draw out type VCB and cable connecting / in boxes of suitable sizes for incoming and out going. (b) The panel shall trip automatically on over load, earth fault short circuit and shunt trip with necessary relays and following:- (i) Resin cast 3 wound type / epoxy resin capsulted CT of ratio 30/5+5 C-10.5 for metering 5 P 10 for protection 15 VA burden - 01 set (ii) Resin epoxy coat PT 11 KV / 110 V with 100 VA Class - I with necessay HT / LT fuses - 01 set (iii) Digital over current and earth fault relay Modal No MC - 61A of L&T or Eason Reyroll or Schneider. (iv) Auxillary relay for buck holtz relay for alarm & trip. (v) DC power pack unit for relays.
Supply, install ,test and commitioning step down transformer indoor type suitable for plint mounting complete with standard accessories / fittings suitiable for HT 11 KV 3 Phase and LT 433 volts 3 phase 4 wire, copper wound with off load taping switch and variation of secondary vltage + 7.5 % in steps of 2.5 % continous rating of capacity 315 KVA with temp rise of 45 deg Cel over an ambbient of 50 deg cel max conforming to IS-2026 and equipped with and including following items:- (a) Lifting Lugs / hooks fortransformer and tanks. (b) Earthing terminal, rating diagram plate and conservator tank. (c) Air release device. (d) Oil filling inlet pipe with plug. (e) Drain outlet pipe with brass gate valve with dummy plug. (f) Conservator with level guage (g) Silica jel breather. (h) First oil fill upto appropriate level as recommended by manufacturer with fresh new oil conforming to IS - 335. (j) Type of connection : delts / star. (k) Cooling: ONAN (l) Vector group : DYN 11 (m) termometer with pocket. (n) Type of connecting arrangement : Cable Termination boxes on bothe HT and LT sides (o) Bucholz relay. (p) Control cable, copper, armoured from transformer to VCB for bucholz alarm & trip. (q) Explosion vent with double diaphram. (r) One extra neutral bushing on top.
M & L for rectification of defects ,painting of feeder pillar / out door LT panels at various places including scraping rusts, cleaning of surfaces, old paint applying two coats of synthetic enamel paint over the surfaces of panel board with spray painting complete all as directed.by Note Parts needed like hinges, door knobs,Ammeter, voltmeter,control wiring, testing etc, to be replaced shall be deemed to be included
M & L for rectification of defect dismantling Air Break Gang Operated Switches HT 11 KV 3 phase,any capacity (200/400) Amps vertical/ horizontal mounted including Insulators and Operating Mechanism for repair/ replacement of broken/ worn out components and insulators etc, with or without taking down from pole all as specified and directed
M & L for rectification of defect dismantling dropout fuse set assembly of current ratting 100 amps 11000 volts grade, complete all as specified and directed
M&L for Earthing complete with galvanised steel earth plate electrode of size 60cm X 60cm X 6mm buried directly in ground (earth pit not less that 2.25metres deep below the normal ground level) withtop edge of the plate not less than 1.5m below normal GL connected to Gl earth steep 32mmx6mm by meain job bolts, nuts,chek nuts and wahser and earthe streep protected by 40 mm dia GI pipe medium grade and connected to main distribution board/earthing test point all as show on electrical plate No 3 of SSR Part I and all as specified including testing on complition. Notes: The unit rate shall also include for excavation, earth work in hard/dense soil, plain cement concrete 1:3:6 mix, Type C1 pit,40mm thick RCC 1:2:4 mix, type B1 cover reinforced with 8mm dia TMT bars @ 150mm C/C both ways, Gl funnel with watering pipe, wire mesh, protection pipe for earth lead upto 7.50m long complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub heading earthing, specified in SSR Part ll. Earth steep and protection pipe beyond 7.5m shall be measured and paid separately.
Subtotal
KCM BUILDERS & CONSTRUCTIONS INDIA PVT LTD
M/S G S GREWAL
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .