Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.1 LAccepted-AOC | L1 | Accepted-AOC ACCEPTED BEING LOWEST BIDDER | |
| 2 | L2₹31.0 L+₹20,174 (0.66%)Rejected-Finance | L2 | Rejected-Finance REJECTED BEING NOT LOWEST BIDDER | |
| 3 | L3₹35.9 L+₹5.1 L (16.6%)Rejected-Finance AT POST SONAJ TAL MALEGAON DIST NASHIK | MALEGAON | NASHIK | MAHARASHTRA | L3 | Rejected-Finance REJECTED BEING NOT LOWEST BIDDER | |
| 4 | L4₹36.4 L+₹5.7 L (18.4%)Rejected-Finance | L4 | Rejected-Finance REJECTED BEING NOT LOWEST BIDDER | |
| 5 | L5₹37.1 L+₹6.4 L (20.7%)Rejected-Finance | L5 | Rejected-Finance REJECTED BEING NOT LOWEST BIDDER |
Tender Value
₹49.9 L
EMD Value
₹99,820
Closing Date
23 Mar 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE KIRKEE
Headquarters CWE Kirkee, Military Engineer Services, Range Hills Road, Kirkee, Pune-411003
REPAIR TO STONE MASONRY BUILDING, LEAKAGE PRONE BLDGS AT DEPOT BN, HRDC BEG AND CENTRE UNDER AGE B/R-II OF GE (CENTRAL) KIRKEE
2023_MES_582490_1
CWE/KKE/TOKEN-76 OF 2022-23
Open Tender
Civil Works
Item Rate
180 days
KIRKEE
AS PER TENDER
6 documents required · 6 mandatory
₹500
Yes
GE CENTRAL KIRKEE
₹99,820
Yes
20 Apr 2023
23 Feb 2023
27 Mar 2023
23 Feb 2023
23 Mar 2023
10 Mar 2023
24 Feb 2023 - 2 Mar 2023
Amount
Dismantling of Asbestos cement (corrugated,semi corrugated,etc) sheets in roof covering including ridge ,wind tie etc, complete all as specified and directed by Engr-in-charge.
M&L for 6mm thick asbestos cement,corrugated or semi corrugated sheets in roof coverings with L-type or J-type cranked hook bolts complete all as specified and directed by Engr-in-charge.
As per item no. 2 above but except AC sheet.
M&L for Asbestos cement two-piece adjustable plain wing ridge 6mm thick complete all as specified and directed by Engr-in-charge.
Dismantling of plain or corrugated/galvalume steel sheeting any gauge,thickness,including Nanital or similar pattern roof coverings complete all as specified and directed by Engr-in-charge.
Dismantling of single layer Manglore pattern or similar tiles as in roofing complete all as specified and directed by Engr-in-charge.
S&F only Mangalore pattern roofing tiles interlocking at sides joints laid dry complete all as specified and directed by Engr-in-charge.
Fixing only Mangalore pattern roofing tiles,interlocking at side joints laid dry complete all as specified and directed by Engr-in-charge.
S&F ridge or hip tiles to suit Manglore pattern of roofing tiles bedded and jointed in CM 1:6 complete all as specified and as directed by Engr-in-charge.
Dismantiling battens for tiles single etc of any size including tilting fillets spaced exc 15cm complete all as specified and as directed by Engr-in-charge.
S&F second class hard wood clean sawn battens at 30 cm centre to centre and section area exceeding 15 and not exceeding 25 sqm complete all as specified and as directed by Engr-in-charge.
As per item No 11 but except battens complete all as specified and as directed by Engr-in-charge.
Dismantling timber scantlings 40 sq cm and over in section, in any position in unframed work complete all as specified and as directed by Engr-in-charge.
All as per sl item no. 13 above but in fillets,rails, posts, rafter,purlins etc under 40Sqm in section complete all as specified and as directed by Engr-in-charge.
S&F for second class hardwood as in scantlings,clean sawn complete all as specified and as directed by Engr-in-charge.
S&F for Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall all,fixed with self tapping screws as specified,including providing end crimp at required location as directed by Engineer-in-Charge,at eaves level shape of crimp match to sheet profile complete all as specified and as directed by Engr-in-charge. Note:The quoted rate shall include provision of end flashing/crimp and no extra payment with regard to this provision will be made to the contractor.
S& F for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridge, roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed by Engr-in-charge.
S&F rolled section as in main and cross beams,hip and jack rafters purlins where connected to common rafters and running rails and guides for sliding doors fixed with cleats or other connecting plates conforming to Fe-410W(Gde E-250)quality Bcomplete all as specified and as directed by Engr-in-charge.
S & F rolled steel work in tubular trusses,purlins etc including special shaped washer etc complete using ERW or induction butt weld tubes confirming to IS 1161-1979 grade st.240 etc and painted with one shop coat of zinc chromate primer including preparation of surfaces at contractor's workshop before fabrication complete all as specified and as directed by Engr-in-charge.
Removing of old water proofing treatment and cleaning the surface of slab and cleaning with wire brushes,removing dust,foreign material,rubbish off the site to a distance n.exc.100m complete all as specified and as directed by Engr-in-charge.
M&L for 10 mm thick rendering in cement mortar 1:3 on RCC roof slabs mixed with water proofing compound @ 3% mixed with by weight of cement finishes even and smooth to receive water proofing treatment complete without using extra cement all as specified and directed by Engineer-in-Charge.
M&L for water proofing treatment over RCC slab by applying oil based bituminous primer surface @0.25 Kg/sqm and laying 3mm thik APP modified water proofing polymeric membrane with 100 mm side and end lap having weight not less than 3.50 kg/ sqm , reinforced with with non-woven polyster reinforced matt weighing not less than 160 gms/sqm polyster core having soften point not less than 1500C, longitudinal tensile strength not less than 650 N/5cm, by torching method and applying a coat of solar reflective aluminium paint @ 0.15 Kg/Sqm on membrance surface including 24 hrs ponding test complete all as specified and as directed by the Engr-in Charge.complete all as specified and as directed by the Engr-in Charge.
Dismantling of wall and ceiling boards or insulation boards/slabs/blanket any thickness including cover fillets complete all as specified and as directed by Engr-in-charge.
S&F interlocking aluminium alloy anodised snap grid consists of main Tee runners of size 38mm x25mm x1.5mm spaced 1200mm centre to centre and cross Tee of size 25mmx25mmx 1.5mm, 1200mm long spaced between the main Tee at 600mm centre to centre to form a grid of 1200mmx600mm and provide a secondary cross tee 25mm x1.4mm ( of length 600mm) to be interlocked of the centre of 1200mmx600mm panel to form a grid of 605mmx605mm and wall angle 25mmx25mmx 2mm. Aluminium alloy extruded section shall be aluminium anodised (minimum 15 micron ) and shall conform to IS 733, IS 1285 and IS 737. including Hangers of GI wire 6mm dia to be fixed by approved rawl plug, level and justers and screws etc.
M&L for 8-9 mm thick Gypsum board/tiles for insulation and accoustic purposes, 60cmx60cm in size fixed on snap grid in ceiling complete all as specified and as directed by Engr-in-charge.
water proofing treatment to Sunken floor are as under:- (a) Cleaning the surface of any description with wire brush,detecting sources of leakages/seepages and removing/taking down unsound treatment surface (b)M&L for making holes with drill machine of dia 18mm for carrying out non destructive waterproofing treatment to floors,sunken portion of toilet/Bathroom and junctions of floor and walls of bath/WC and floor traps (combined unit)by using consrtuction chemical method as hydrophobic PU grouting with first course of injection MDI based PU foam and second course of injection with PU plain all as per manufacturers instruction etc and M&L for fixing the metallic packer for hydrofobic PU foam sealer as per manfacturer specification. NOTE:- (a)The PU foam and PU plain shall have 100% solid sand solvent free and shall expand 30-40times its volume at liquid stage in presence of water,the PU plain injection shall have minimum 100 CPS viscosity and shore hardness minimum 50D. (b)Shall have minimum 100CPS viscosity and shore hardness minimum 50D.
Dismantling of precast interlocking Chequered tiles laid dry of any description thickness & size complete all as specified and as directed by Engr-in-charge.
M & L for 75 mm thick, PCC (1:4:8) type B-2 using 40 mm graded stone aggregates as in sub base as Plinth protection complete all as specified and as directed by Engr-in-charge.
M & L for coloured glossy finish chequered cement concrete tiles of size 30 cm x 30 cm x25 mm thick with grey cement and pigments , set jointed and pointed in neat cement slurry in floors incl screed bed or bedding layer of mortar 15mm thick average thickness for laying floor finishes in cement mortar 1:6 complete all as specified and as directed by Engr-in-charge.
M&L for external stone walls/steps of any height are as follows:- (a)Cleaning of external stone surface of walls/steps at any height with pressure pump with clean water (a) Applying one coat of cleaning solution of Dr Fixit/pidilite or other reputed brand and throughly cleaning the surface, (b)The loose masonary joints to be properly pointed with (1:3) cement sand mortar mixed with WPC complete all as specified and directed. (c)Necessary scafolding shall deemed to be included in the quoted rate.scafolding shall be having ease of access for inspection purpose (d)Second washing of the surface of wall/steps any height (whereever required at site as directed by Engineer-in-charge) with super heated steam to remove grease,moss algaee & bird dropping etc with heavy jet pressure pumps (Torik stone cleaning similiar pumps,Tensid UK LTD or Doff superheated steam cleaning or similiar pumps as approved) complete all as specified and directed. (d) The filling of joints between stones with cement-Asian equivalent paint grout and application of two coats of hydrophobic stone sealer as per manufacturers instructions complete all as specified and as directed by Engr-in-charge.
NOTE:- 1-Quoated rate includes providing necessary scafolding of G+2 stories bldg with safety measure of labour at any height as per site requirement. upto 9 Mtr height. 2-Before quoting the tender contractor should visit the site. 3-Treatment should be carried out with skilled labour and by authorized applicators.
S&F Rotational moulded polyethylene water storage tank three layer white cylindrical vertical with top closed hoisted and fixed in position all as specified and directed capacity 500 ltr including dismantling existing tanks exc 250ltr and n exc 500 ltr removing to store.
S&F rotational moulded polyethylene water storage tank three layer white cylindrical vertical with top closed hoisted and fixed in position all as specified and directed capacity 1000 ltr including dismantling existing tanks exc 500ltr and n exc 1000 ltr removing to store.
Demolition of precast concrete block /brick work walling built in cement mortar
Taking down cement plaster on wall /concrete surface etc including racking out joints hacking for key scrubing down with water etc all complete all as specified and as directed by Engr-in-charge.
M&L for Precast cement concrete block masonry using type C1 1:3:6 (20 mm graded aggregate) with solid blocks, exc. 10 cm in width and setting in mortar1:6 complete all as specified and as directed by Engr-in-charge.
M&L for rendering 15 mm thick on faces of brick/ PCC block masonry wall using cement plaster 1:4 and rendering is to be finished even and smooth (without using extra cement) complete all as specified and as directed by Engr-in-charge.
M & L preparation of newly plastered surface and applying two coat of cement base paint over a coat of primer on wall etc complete all as specified and as directed by Engr-in-charge.
M & L for rendering 15mm thick on fair faces brick work /PCC block masonary or concrete surface of wall using cement plaster 1:6 and finished even and smooth (without using extra cement) complete all as specified and as directed by Engr-in-charge.
M & L preparation of newly plastered surface and applying two coat of oil bound Distember over a coat of primer on wall etc complete all as specified and as directed by Engr-in-charge.
Clearing away all grass vegetation, saplings,shrubs, brushwood, undergrowth, roots, and trees not exceeding 30 cm girth (measured one metre above ground level) on chajjah,slab,stone masonary/block masonary wall and removing rubbish upto a distance of 50 metres outside the periphery of the area under clearance except inthe case of surface dressing complete all as specified and as directed by Engr-in-charge.
Supply only integral water proofing compound.
M/S K.D.MATE
MAHESH DADAJI BACHHAV
SAMBHAJI D JARANDE
MANIYA CONSTRUCTION CO
greenstone construction
M/S JAYCONSTRUCTION CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .