| Sl No | Description | Qty | Unit | Unicare Technologies Pvt Ltd L1 | M/s R. K. Bhambri L2 |
|---|---|---|---|---|---|
| 1.00 | Designing, (Hydraulically, structurally and aesthetically), providing, constructing, hydraulic testing , commissioning and giving satisfactory trails of STP 50 KLD (Package Type) type any technology meeting out-put criteria as per specified below or as per recommended by OEM Technology, foundation of all E/M equipment ,associated piping work with required valve ,electrical control panel with interconnecting cable etc complete as turnkey Job with all involve electrical ,digital and mechanical works as per detail specification for civil electrical and mechanical component with all duties and taxes complete all as specified and directed (a) Inlet Parameter (i) BOD - 250-300 mg/ltr (ii) COD - 400-500 mg/ltr (iii) TSS - 250-300 mg/ltr (iv) Oil & Grease - 20-30 mg/ltr (v) pH - 6 to 9 (vi) Coliform - 1 x 10 6 MPN/100ML (vii) Peak Factor - 3.0 (b) outlet parameter of sewage treated water are as follows : (i) BOD < 10 mg/ltr (ii) COD < 30 mg/ltr (iii) TSS < 10 mg/ltr (iv) Oil & Grease < 10 mg/ltr (v) pH - 6.5 to 8.5 (vi) Coliform - 1000 MPN/100ML (vii) Residual Chlorine - > 0.5 mg/ltr (viii). Nitrogen < 10 mg/Ltrs (ix). Phosphours < 1 mg/Ltrs | 1 | Each Job | 32,40,067 ₹32,40,067 Lowest | 42,00,000 ₹42,00,000 |
| 1.01Note: 1. The complete set up should be fully factory fabricated (MOC - MSFRP).The MS sheet thickness to be not less than 6mm and inside tank FRP coating 3mm. 2. The entire electrical equipments and pumps to be enclosed in attached transparent weather proof single enclosure/ attached pump room with proper lighting and exhaust system. All inspection ramp and stairs to be fitted from factory. 3. The entire plant should be on common skid (Plug and play type) to be rested on RCC platform above ground. No fabrication will be allowed at site. 4. The entire process design and drawings to be vetted by NIT/IIT. all as specified and directed by Engr-in-charge. | |||||
| 2.00 | Excavation in trenches not exc. 1.5m wide and not exc 1.5m deep in hard/dense soil and getting out complete all as specified and directed. | 108 | Cum | 659 ₹71,172 | 200 ₹21,600 Lowest |
| 3.00 | Returning filling in trenches including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in any type of soil complete all as specified and directed. | 34.4 | Cum | 314 ₹10,801.6 | 100 ₹3,440 Lowest |
| 4.00 | Removing surplus excavated material to a distance not exc 50m and depositing where directed at a level not exc 1.50m above the starting point complete all as specified and directed. | 76.2 | Cum | 298 ₹22,707.6 | 100 ₹7,620 Lowest |
| 5.00 | M&L for filling approved fine river sand in trenches as cable cushion to the full width of excavated trench, under and over cable complete all as specified and as directed.
(Note : Punned thickness of sand shall be measured) | 14 | Cum | 3,295 ₹46,130 | 600 ₹8,400 Lowest |
| 6.00 | M&L for bricks slightly over burnt (kiln burnt), modular bricks, best quality, locally available, laid flat, dry, laid in trenches along the length of cable transvarsally with width equal to length of brick for cable protection complete all as specified and directed. | 1.2 | Per 1000 | 12,552 ₹15,062.4 | 10,000 ₹12,000 Lowest |
| 7.00 | Supply ,laying ,testing cable xlpe insulate of size 50 sqmm 3.5 core, complete all as specified and directed. | 173 | RM | 769 ₹1,33,037 | 500 ₹86,500 Lowest |
| 8.00 | M &L for concrete bed PCC 1:3:6 type C-2 using 40mm graded stone aggregate to drain pipe 200/225 mm bore including packing under and haunching against the sides of pipes after they are laid and tested including removal of debris outside MD land complete all as specified and directed. Note : Thickness of bed below the barrel of pipe 10cm for pipe 100 mm and 150mm dia, 15cm for 200mm dia & over | 85 | RM | 800 ₹68,000 | 600 ₹51,000 Lowest |
| 9.00 | M&L for 200 ID/220 OD MM dia DWCPE SN-8 pipes premium quality single soceted in length with joints laid in trenches or in floors including all necessary fitting , joints etc,all as specified and directed complete all as specified and directed. Make-ISI marked approved. | 85 | RM | 235 ₹19,975 Lowest | 700 ₹59,500 |
Tender Value
₹41.8 L
EMD Value
₹84,000
Closing Date
7 Jul 2026, 6:00 pmClosed
CWE MHOW
HQ CWE MHOW, MHOW CANTT, MHOW-453441
PROVN OF STP FOR AIRFIELD SINGLE OFFRS ACCN COMPLEX AT MCTE UNDER GE MCTE MHOW
2026_MES_762207_2
CWE/MHOW/72(T) OF 2025-26
Open Tender
Civil Works
Item Rate
180 days
HQ CWE MHOW
PLEASE REFER TENDER DOCUS.
8 documents required · 8 mandatory
₹500
GE (MCTE) MHOW
₹84,000
7 Sept 2026
8 Jun 2026
9 Jul 2026
8 Jun 2026
7 Jul 2026
23 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Designing, (Hydraulically, structurally and aesthetically), providing, constructing, hydraulic testing , commissioning and giving satisfactory trails of STP 50 KLD (Package Type) type any technology meeting out-put criteria as per specified below or as per recommended by OEM Technology, foundation of all E/M equipment ,associated piping work with required valve ,electrical control panel with interconnecting cable etc complete as turnkey Job with all involve electrical ,digital and mechanical works as per detail specification for civil electrical and mechanical component with all duties and taxes complete all as specified and directed (a) Inlet Parameter (i) BOD - 250-300 mg/ltr (ii) COD - 400-500 mg/ltr (iii) TSS - 250-300 mg/ltr (iv) Oil & Grease - 20-30 mg/ltr (v) pH - 6 to 9 (vi) Coliform - 1 x 10 6 MPN/100ML (vii) Peak Factor - 3.0 (b) outlet parameter of sewage treated water are as follows : (i) BOD < 10 mg/ltr (ii) COD < 30 mg/ltr (iii) TSS < 10 mg/ltr (iv) Oil & Grease < 10 mg/ltr (v) pH - 6.5 to 8.5 (vi) Coliform - 1000 MPN/100ML (vii) Residual Chlorine - > 0.5 mg/ltr (viii). Nitrogen < 10 mg/Ltrs (ix). Phosphours < 1 mg/Ltrs | 1 | Each Job | - | - |
| 2 | Excavation in trenches not exc. 1.5m wide and not exc 1.5m deep in hard/dense soil and getting out complete all as specified and directed. | 108 | Cum | - | - |
| 3 | Returning filling in trenches including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in any type of soil complete all as specified and directed. | 34.4 | Cum | - | - |
| 4 | Removing surplus excavated material to a distance not exc 50m and depositing where directed at a level not exc 1.50m above the starting point complete all as specified and directed. | 76.2 | Cum | - | - |
| 5 | M&L for filling approved fine river sand in trenches as cable cushion to the full width of excavated trench, under and over cable complete all as specified and as directed.
(Note : Punned thickness of sand shall be measured) | 14 | Cum | - | - |
| 6 | M&L for bricks slightly over burnt (kiln burnt), modular bricks, best quality, locally available, laid flat, dry, laid in trenches along the length of cable transvarsally with width equal to length of brick for cable protection complete all as specified and directed. | 1.2 | Per 1000 | - | - |
| 7 | Supply ,laying ,testing cable xlpe insulate of size 50 sqmm 3.5 core, complete all as specified and directed. | 173 | RM | - | - |
| 8 | M &L for concrete bed PCC 1:3:6 type C-2 using 40mm graded stone aggregate to drain pipe 200/225 mm bore including packing under and haunching against the sides of pipes after they are laid and tested including removal of debris outside MD land complete all as specified and directed. Note : Thickness of bed below the barrel of pipe 10cm for pipe 100 mm and 150mm dia, 15cm for 200mm dia & over | 85 | RM | - | - |
| 9 | M&L for 200 ID/220 OD MM dia DWCPE SN-8 pipes premium quality single soceted in length with joints laid in trenches or in floors including all necessary fitting , joints etc,all as specified and directed complete all as specified and directed. Make-ISI marked approved. | 85 | RM | - | - |
| 10 | Cutting into existing manhole for connecting new drain pipe of 200/225 mm bore and making good to pipe and rendering disturbed surface where drain pipe have been insereted cutting out existing benching for forming branch channel (1/2 round or 3/4 section as required) in cement concrete 1:2:4 type B1 and finished the surface even and smooth and reforming benching complete all as specified and directed. | 8 | Each | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.24 MB
GenralPagesAndConditions72T.pdf
Tender Documents • 0.63 MB
BOQ_862897.xls
BOQ • 0.39 MB
PS72T.pdf
Tender Documents • 0.53 MB
SpecialCondition72T.pdf
Tender Documents • 0.23 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .