Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹180Accepted-AOC | L1 | Accepted-AOC Lowest and reasonable | |
| 2 | L2₹29.7 L+₹1.5 L (5.25%)Rejected-Finance 93 61 AGARWAL FARM MANSAROVER JAIPUR 302020 | JAIPUR | JAIPUR | RAJASTHAN | 302020 | L2 | Rejected-Finance Not Lowest |
Tender Value
₹24 L
EMD Value
₹48,000
Closing Date
20 Jun 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Jaipur
HQ CWE Jaipur, Kalyan Marg, Jaipur
PROVN OF EXTERNAL ELECTRIC SERVICES FOR TRAINING AND OTHER AMENITIES UNDER AGE (I) NIWARU MIL STN
2022_MES_524040_1
CWE/JPR(N)/82151/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE (I) Niwaru Jaipur
enlisted with MES in Class E and above and category b (ii)
7 documents required · 7 mandatory
₹500
Yes
AGE (I) Niwaru Jaipur
₹48,000
Yes
29 Jul 2022
13 May 2022
22 Jun 2022
13 May 2022
20 Jun 2022
26 May 2022
Amount
Supply, installation & testing of HT 11 KV, 3 phase, 50 Cycles, 21KA for 3sec, 3 way, Motor Operated, One Side Extensible, Outdoor type SF6 Insulated RMU made out of 3.15 mm CRCA steel sheet with powder coated with 2 Nos. Vacuum circuit breaker (CB) feeder as Incomer + 1No. Vacuum circuit breaker (CB) feeder as Outgoing with Air Insulated Bus Connected Metering unit (M) along with common item & accessories for totally enclosed metal clad SF6 Ring main unit outdoor type, SF6 filled having rupturing capacity 350 MVA , over load & earth fault protection of rating 630 Amps alongwith fault passage indicator(FPI), integral cable earthing switch(ICES), voltage present indicating system (VPIS), earth fault indicator (EFI) and short circuit indicator (SCI) on each circuit breaker etc. complete all as specified and directed with comprising following :-
Each Vacuum Circuit Breaker (CB) Feeder Comprise of following as Incoming (02 Nos) :- (a) 11KV, 630A, 21KA VCB with Motor Sp charging mechanism, trip & closing coil for remote operation :- 01 No (b) Manually Operated 630A disconnector with built-in earth switch :- 01 No (c) Mechanical position Indicator (ON/EARTHED) :- 1 No
(d) CT with ratio 200-100/1-1A, 2.5VA, CL-10P10 for Protection & 2.5VA, Cl-0.5 for Metering :- 1 Set (e) Multifunction meter with Maximum Demand (Secure make – Elite-445 or equivalent.) :- 01 No (f) Self-Powered 3O/C+1E/F Relay (C&S / Ashida Make – CSPR-V5) :-01 No (g) Live Cable Indication :- 01 No (h) Cable termination bushing suitable for 1 run size upto 3Cx300Sq mm XLPE cable :- 01 Set (j) Cable termination cover boots (Push on type) :- 01 set Each Vacuum Circuit Breaker (CB) Feeder Comprise of following as Outgoing (01 No) :- (a) 11kV, 630A, 21kA VCB with Motor Sp charging mechanism, trip & closing coil for remote operation:-01 No. (b) Manually Operated 630A disconnector with built-in earth switch :- 01 No (c) Mechanical position Indicator (ON/EARTHED) :- 01 No (d) CT with ratio 200-100/1-1A, 2.5VA, CL-10P10 for Protection & 2.5VA, Cl-0.5 for Metering :-01 Set (e) Multifunction meter with Maximum Demand (Secure make – Elite-445 or eq.) :- 01 No (f) Self-Powered 3O/C+1E/F Relay (C&S / Ashida Make – CSPR-V5) :-01 Nos (g) Live Cable Indication :- 01 No
(h) Cable termination bushing suitable for 1 run size upto 3Cx300Sq mm XLPE cable :01 Set (j) Cable termination cover boots (Push on type) :- 01 Set Air Insulated Metering Unit (M) Connected to Bus :- (a) Air Insulated enclosure with necessary Bus connection: 01 Set (b) PT 11kV/√3 / 110V/√3, 25VA, Cl-0.5 :- 01 Set Common Items & Accessories for RMU :- (a) Manometer with Green & Red zone for indicating pressure of gas inside the tank fitted on RMU:- 1 No (b) Battery Charger, I/P-230V AC/110V AC, O/P-24V DC, 7AH:- 01 No (c) Operating Handle (Supplied Loose with RMU):- 1 Set Note : The quoted rates include PCC footings with brick masonry 1.2 M wide on all four sides including making arrangements for cable entry on rear side of RMU duly plastered including approach steps. RMU shall be installed at a height of 75 cm above ground level.
Supply, installing, testing and commissioning of Air break, gang operated, triple pole switch 200 Amp rating complete with fuse carriers and HT fuse elements., outdoor, horizontal / vertical mounting type (ISI marked), mechanically operated, mounted on insulators and frame work with operating mechanism worked from ground level with locking arrangements including Godrej pattern 65mm pad locks with two keys, complete suitable for HT 11 KV, 50 Hz AC supply including necessary electric connections complete including taking down old U/S all as specified and directed.
Supply and erect two pole structure comprises of 02 Nos of 11 meter Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-55 with and including anti-climbing device, HT Danger notice plate 02 Nos lightening arrestor set of three, stay assembly 4 Nos & cross arms as required, GI pipe of 100mm dia light grade for protection of cable and connecting to earthing with 4mm dia GI wire etc. complete all as specified and directed. Note:- Necessary excavation, returning, filling, removal and PCC for foundation of pole & stays shall be deemed to be included in rate quoted and no misunderstanding shall be entertained.
Supply, installing, testing and commissioning of transformer, step down,11/0.433 KV (at no load), outdoor type, copper wounded, with first filling of transformer oil, outdoor type, 3 Phase 4 wire with off load tapings on HT side to vary secondary voltage within limit of capacity 100 KVA (01 No), 3 phase,4 wire,50 C/S, oil immersed naturally cooled with external cooling tubes/fin, delta connection on HT side and star connection on LT side with tapping of HT side to vary secondary voltage at (+/-) 2.5% to (+/-) 7.5% in step including first filling of transformer oil, all fittings and accessories etc. complete all as specified and directed.
Material and labour for construction of Substation (9Mtr x 9 Mtr) , outdoor type including necessary excavation, levelling, spreading of gravels etc. complete with comprising the followings :- (a) Platform for Transformer :- M & L for Size 2500X2500X1500 mm (500 mm below GL & 1000 mm above GL) for installation of transformer with 100mm thick PCC 1:4:8 type D2 as in foundation, brick wall of 230 mm including rendering with cement Mortar 1:4 and filling under floors watering and well ramming with soil and also provide100 mm thick PCC 1:2:4 coping on the top of platform and two coats of Cement based paint over a coat of Primer including preparation of newly plastered surfaces. 1.5 metre wide ramp on one side of platform to Path with slope of 60 degree. (b) S & F PVC coated chain link fencing of size 100 x 100 x 4mm dia, 2.1 metre high with swan neck, angle Iron post of 50x50x5mm with 40x4mm flat Iron fixed with nut & bolts with spacing not more than 2.5 mtr, 10 mm dia rounded bars as in spacers and two coats of synthetic enamel paint over a coat of zinc oxide along with GI 2 strand barbed wire on swan neck, PCC 1:3:6 Type C2 as in foundation including necessary excavation and earth work. (c) M&L for 100 mm thick PCC 1:4:8 Type D2 (Using 40 mm graded stone agg) as in Sub base, 50 mm thick PCC 1:2:4 Type B1 (Using 20 mm graded stone agg) with necessary excavation and earth work. 1 metre wide along both side of fencing all around the substation.
(d) M&L for 4 metre wide Steel gate with RCC Pillars, two coats of Synthetic enamel paint on steel surfaces over a coat of Zinc oxide primer with preparation of surface including necessary excavation and earth work, returning filling and removal for column of steel gate with two coats of Cement based paint over a coat of Primer including preparation of newly plastered surfaces as per TD No. TD/2008/101 sheet No 1/3, 2/3 & 3/3. (e) M&L for PCC path 4 metre wide and 10 metre long using 100 mm thick PCC 1:4:8 Type D2 (Using 40 mm graded stone agg) as in sub base, 100 mm thick PCC 1:2:4 Type B1 (Using 20 mm graded stone agg) as in paths including construction and expansion joints and necessary excavation and earth work. (f) Gravels of 40 mm size upto 100 mm height all around the Platform, path and inside the fencing of Sub Station. (g) Danger notice plate 02 Nos on the gate & fencing of Sub Station.
M&L for cable end termination, jointing kit, HT 11 KV grade size 120 to 240 Sqmm x 3 core, heat shrinkable, indoor type complete with jointing material suitable for HT XLPE cable 3 core 11 KV grade complete all as specified and directed.
M&L for cable end termination, jointing kit, HT 11 KV grade, size 95 Sqmm x 3 core, heat shrinkable, indoor type complete with jointing material suitable for HT XLPE cable 3 core 11 KV grade complete all as specified and directed.
M&L for cable end termination, jointing kit, HT 11 KV grade, size 95 Sqmm x 3 core, heat shrinkable, outdoor type complete with jointing material suitable for HT XLPE cable 3 core 11 KV grade complete all as specified and directed.
M&L for cable, jointing kit, HT 11 KV grade size 95 Sqmm x 3 core, heat shrinkable, straight through type complete with jointing material suitable for HT XLPE cable 3 core 11 KV grade complete all as specified and directed.
Supply & Fix Automatic Power Factor Correction (APFC) Panel with MD—XL Double metalized paper (Extra Low Loss) Capacitor for 3 phase, 440 V, 50 Hz system for permissible non- leaner load 20% of capacity 60 KVAR with 4 steps (Capacitor size 20x2, 10x1, 05x1, 02x2, 01x1) alongwith MD-XL capacitor of given size and suitable MCCBs as Incomer complete all as specified and directed.
M&L earthing complete as per electrical plate No 3 of MES SSR Part-I with galvanised steel earth plate electrode 600 mmx600mmx6mm, buried directly vertically in ground in a pit depth not less than 2.25 metres below ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level connected to and including galvanised iron or steel earth strip 32mm x 6mm by means of bolts, nuts check nuts and washers of galvanised iron or steel. Earthing strip shall be protected by galvanised iron or steel pipe 32mm bore light grade and connected to continuous earth wire on pole / test point. Watering pipe shall be 20 mm bore GI medium grade. The earthing shall be of inclusive of excavation & earth work in any type of soil, charcoal, salt, funnel PCC pit and RCC cover complete all as specified & tested complete. NOTE:- (i) The concrete pit shall be made in PCC 1:2:4 type B-O, using 12.00 mm graded crushed stone aggregate 40mm thick precast cover slab of RCC (1:2:4), type B-1, using 20mm graded crushed stone aggregate with suitable MS handle in lieu of CI cover. Reinforcement in cover shall be of 8mm dia TMT bars laid @150mm c/c both ways. (ii) Quoted shall include the cost of 7.5 metre GI pipe for protection of earth wire/strip. (iii) Quoted shall include cost of 7.5 metre earth lead wire/strip. (iv) Earth electrode shall be surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides
Incoming :- (i) MCCB 415 Volts of capacity 250 Amps 35 KA, 4 pole - 01 No ( 01 No- Incoming from transformer ) Bus Bar :- (i) 01 set of 400 Amps, TPN, Aluminium Bus bars Outgoing :- (i) MCCB 415 volts of capacity 100 Amps 16 KA, 4 pole - 02 No (Outgoing to OAT & 01 Spare) (ii) MCCB 415 volts of capacity 63 Amps 16 KA, 4 pole - 03 Nos (Outgoing Shopping Complex, Gym & 01 spare) (iii) On load Change over, 4 pole,415 Volts, 250 Amps:- 01 No (iii) MCB, four pole, 230 volts of capacity 10 Amps , -02 Nos (Outgoing to fountain pump & 01 spare) (iv) MCB, SPN, 415 volts of capacity 20 Amps -03 Nos (street/Gate light & 01 spare) (v) 3 ph LED multifunction meter CI 0.5 :-01 No (vi) LED indicator lamp –01 No (set of three) :-01 Set (vii) Cable Gland of size 185/150 Sqmm 3.5 Core:-02 Nos (viii) Cable Gland of size 50 Sqmm 3.5 Core:-01 Nos (ix) Cable Gland of size 10 Sqmm 4 Core :- 04 Nos (x) Cable Gland of size 6 to 16 Sqmm 2 Core:- 02 Nos (xi) Din type Astronomical Digital Time switch for street light:-01 Nos (xii) power contactor with control relay of capacity 9 Amps for street light:- 01 Nos
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing as required 32x6mm galvanised iron strip etc.
Supply, laying, connecting & testing of XLPE Insulated screened PVC bedded galvanized steel strip or wire armoured electric power, cable (heavy duty) with aluminium conductor, 11 KV grade cross sectional area 240 sqmm 3 core laying in trenches or passing through pipe etc. complete all as specified and directed.
Supply, laying, connecting & testing of XLPE Insulated screened PVC bedded galvanized steel strip or wire armoured electric power, cable (heavy duty) with aluminium conductor, 11 KV grade cross sectional area 95 sqmm 3 core laying in trenches or passing through pipe etc. complete all as specified and directed.
Supply, laying, connecting & testing of XLPE Insulated screened PVC bedded galvanized steel strip or wire armoured electric power, cable (heavy duty) with aluminium conductor, 1100 Volts grade cross sectional area 185 sqmm 3.5 core laying in trenches or passing through pipe etc. complete all as specified and directed.
Supply, laying, connecting & testing of XLPE Insulated screened PVC bedded galvanized steel strip or wire armoured electric power, cable (heavy duty) with aluminum conductor, 1100 Volts grade cross sectional area 150 sqmm 3.5 core laying in trenches or passing through pipe etc. complete all as specified and directed.
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation etc or for shafts, wells, cess pits, manholes, pier holes, laying cables erection of poles / struts/stays etc not exceeding 10 Sqm on plan, not exceeding 1.5 metre in depth and getting out in any type of soil complete all as specified and directed.
Removing of excavated material (soil) to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.50metre above the starting point complete all as specified and directed
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm in any type of soil complete all as specified and directed.
M&L for sand cushioning to PVC underground cable with crush stone sand and punning down to provide a required cusion to complete all as specified and directed. Note:- Punned thickness shall be considered for payment purpose
Supplying and laying factory made un-reinforced PCC precast cable covers class HV, type I, peak, size 300mm x 180mm x 40mm complete all as specified and directed.
Supplying and laying factory made un-reinforced PCC precast cable covers class LV, type I, peak, size 300mm x 180mm x 40mm complete all as specified and directed.
Supply & fixing or laying in repair galvanised steel tubing light grade (ISI marked) 80mm bore for protection of underground cable on poles / walls under road crossing etc complete all as specified & directed.
M/S Anil Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .