Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹14.5 L
EMD Value
₹14,500
Closing Date
6 Jan 2025, 2:00 pmClosed
SUPERINTENDING ENGINEER EDC LONI
33/11 KV SUBSTAION KOYAL ENCLAVE GDA BHOPURA GZB
WORK OF CONSTRUCION OF 11KV LINE AND RENOVATION WORK OF 33 KV LINES
2024_PVVNL_985575_1
T-32/W/EDC/LONI/2024-25
Open Tender
Electrical Works
Item Wise
365 days
EDD-1, II, III LONI
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,540
SUPERINTENDING ENGINEER EDC LONI
₹14,500
Yes
27 Mar 2025
21 Dec 2024
6 Jan 2025
21 Dec 2024
6 Jan 2025
21 Dec 2024
Amount
Cartage of PCC Pole & ST Pole 8.5/9/11/13 Mtr. Long From Central store GZB/Shahibabad JE Store (Dist.) to site of work including loading unloading of both ends. ( Distance up to 0-60 km.)
cartage of Other Line Material (Other then Pole) ACSR Dog Conductor, 11 KV XLPE Cable Size 3x185 mm2, 33 KV XLPE CABLE 3X300 SQMM, 33 KV XLPE CABLE 3X300 SQMM JOINTING KIT (OUTDOOR), 33 KV Cross Arm, Top Channel 100x50x2240 mm2, Dropper Channel 100x50x2240 mm2, T-Off Channel, M S Angle 75x75x6x2028 mm2 for T/F Base, F-Bracket for 33 KV, 33 KV Pin Insulator with Pin & Nut, 33 KV Polymeric Disc Insulator with Fitting, 11 KV Pin Insulator with Pin & Nut, Polymeric Disc Insulator, Disc Fitting,, Stay Set Complete, 33 KV stay set 20x1800, Barbed Wire, Stay wire 7/8 SWG, Earthing Complete By Earthing Rod 2540x18000, GI Wire 6/8 SWG, 33 KV Post Insulator, MS Channwl for Bracket, MS Angle for Bracket, MS Angle for Guarding 65x65x6 SQMM, 11 KV Cable Jointing Kit Outdoor Type Size 3x185 mm2, 11 KV Cable Jointing Kit Indoor Type Size 3x185 mm2, 11 KV Cable ST J/Kit Indoor Type Size 3x185 mm2 (straight Through) from Central Store Gzb./Shahibabad JE Store (Dist.) to site of work including loading unloading of both sides(. ( Distance up to 0-60 km.)
Excavation of Foundation pit in Normal Soil/Soft and Hardsoil Rock and its back filing and leveling Erection of Single pole with PCC Pole/ ST Pole encluding Fixing of all accessories like all types of MS Angel/MS Channel and brackets, cross arm, All types Disc. and Pin Insulator & LT Insulator etc. (fully dressed) including MS galvanised fabricated items, after digging of a suitable size pit for each pole. Work shall be done as per RESPO specification. Single PCC Pole 8.5 Mtr. Long/ST Pole /9/11/13 Mtr. Long.
Concreting /Grouting of PCC Pole /ST Pole 8.5/9/11/13 Mtr. Long Including back filling and ramming work & muffing(on STP Poles) etc. shall be done as per RESPO specification.
Erection, Fixing of stay rod 16x1800 mm after digging of a suitable size pit shall be done as per RESPO specification including fixing of stay wire clamp and nuzzling etc with all accessories related to concern work.
Fixing & Grouting of stay set with GI wire including execavation of stay pit, concreating, installation of all accessories including stay clamp, stay insulator, anchor plate, nut & bolts complete as per technical specification and RESPO drawing.
Earthing of supports with M.S. Earth Rod 2540x40 mm long including driving of M.S. Rod 1 Mtr. Apart from support 0.5 Mtr. Below ground level and connecting with support with the help G.I wire No. 6 SWG.
Binding, Sagging and jumpring etc. Of ACSR Weasel/ Rabit/Dog Conductor on the pole as per RESPO specification and as per direction of engineer in charge it includes cost of labor, T&P Carrier etc. Prepared for proper completion of work.
Laying of ACSR DOG Conductor in Proper mannar
Carriage of 11 KV VCB O/G CTR 200/100/5A. 350 MVA(1250 Amp) from Central store GZB / Shahibabad /JE Store (Dist.) to site of work including loading unloading of both ends. (Distance up to 0-60 Km.)
Mounting, Fixing & commisioning of 11 KV VCB O/G CTR 200/100/5A. 350 MVA(1250 Amp) with all accessories.
Carrige of Pole Scrape, Damage Conductor, Old VCB, from site of work to JE store/Store Centre (Dist.) including loading unloading of both ends with the help of Crane if required. (Distance up to 0-60 Km.)
Laying of overhead 11KV XLPE Cable 3x185sqmm including Laying charges of ACSR Dog Conductor & G.I. Wire for support of hanging purpose of XLPE Cable as per related Estimate & direction of Engineer incharge.
Laying of Underground (HDD Method) 11 KV XLPE Cable 3x185sqmm with laying of HDPE pipe including cost of HDPE Pipe as per related Estimate & direction of Engineer incharge.
Laying of Underground (HDD Method) 33 KV XLPE Cable 3x300sqmm with laying of HDPE pipe including cost of HDPE Pipe as per related Estimate & direction of Engineer incharge.
Fixing, Mounting & commisioning of 11 KV Jointing Kit 3x185 XLPE SQMM (I/D) & (O/D) Properly as per RESPO Norms
Fixing & commisioning of 11 KV 3x185 XLPE SQMM Straight Through Properly as per RESPO Norms
Fixing of G.I. Pipe 6" Dia including of nut bolt & clamps etc.
Fixing of 33 KV CABLE BOX Jointing Kit (O/D) 3X300 SQMM Properly.
Providing & Fixing MS holding Clamps for ST Pole/Pcc Pole made from 50x6 mm MS Flat with nut and bolts
Providing & Fixing of Guarding with G.I. Wire 6/8 SWG (Each Span 40Mtr)
Providing & Fixing Aluminium Lug 8MM with nut and bolt for earthing.
Providing & Fixing Stone Pad 300x300x75 mm2.
Providing & Fixing aluminium Binding wire.
Providing & Fixing Danger Board with Clamp for 11 KV
Providing & Fixing of Different sizes of nuts and bolts for different type of clamps with washers of best quality as per requirement
Powertech Engineers (BID ID -4835266)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .