Tender Value
₹19.6 L
EMD Value
₹39,260
Closing Date
13 Jul 2022, 3:00 pmClosed
DIRECTOR IICT
IICT HYDERABAD
Renovation of Oxygen Gas Plant at Pilot plant complex Moulali at IICT Hyderabad.
2022_CSIR_121440_1
ESD/L-254/22
Open Tender
Civil Works
Item Rate
60 days
IICT HYDERABAD
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
DIRECTOR
₹39,260
24 Aug 2022
6 Jul 2022
15 Jul 2022
6 Jul 2022
13 Jul 2022
6 Jul 2022
Amount
Dismantling roofing including ridges, hips, valleys and gutters etc.,and stacking the material within 50 metres lead of : Asbestos sheet
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved
Dismantling existing rolling shutter with necessary battens and beading including stacking the serviceable material within 50 metres lead.
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. With cement mortar 1:4 (1 cement : 4 fine sand)
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 gradedstone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin-charge. The sheet shall be fixed using self drilling / self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Ridges plain (500 - 600mm)
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete Flashings/ Aprons.( Upto 600 mm)
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.Purlins 50*50 ( 5 mm thick)
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designedpipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement primer
Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade : Two or more coats on new work
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work Rolling Shutter
Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 25 mm nominal outer dia Pipes
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm nominal bore
Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 100 mm diameter
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern.
Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge 15 mm to 40 mm nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings External work 50 mm dia nominal bore including uplings,unions,elbows etc complete as directed by engineer-in-charge
Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge. In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) Acid and alkali resistant tile
Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge. In dado/skirting on 12 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) Acid and alkali resistant tile
Providing fixing thermal insulation of ceiling (under deck insulation) with Resin Bonded Fibre glass wool onforming to IS : 8183, density 24kg / m3, 50mm thick, wrapped in 200 G Virgin Polythene bags, fixed to ceiling with metallic cleats (50x50x3 mm) @ 60 cm and wire mesh of 12.5 mm x 24 gauge wire mesh, for top most ceiling of building.
Supplying and stacking at site including filling and levelling moorum
Providing and fixing Industrial exhaust fans as directed by engineer-in-charge
Exposing the corroded steel around its full circumference and cleaning the same to remove all loose scales and corrosion deposits by hard brush with emery paper or, by any suitable mechanical means as directed by Engineer-in-Charge, so as to get bright conditions and removing the corrosion deposits from pits and imperfections within its surface by compressed air and water at a high pressure. Providing and applying one full coat of anti corrosive treatment of epoxy 'A' (Nitozinc primer of FOSROC Product ) or any other approved compound over the cleaned and prepared surface as per manufacturers specifications including, providing, sprinkling silica sand on freshly coated reinforcement to have a proper bond. Nitozinc Primer Std 8.0 m2 / litre/coat
Dismantling of Existing DB's, Switch Boards and removing of Old wiring in the Shed : Dismantling of DB's of TPN -FU/ MCB DB's switchgears as out goings and disconnection of existing connected cables,earth wires from switchgears, Metal Conduits in the walls. The work includes all related chipping /civil works removing of old wiring to FTL's ,Ceiling fans,Power sockets, 'sand other electrical accessories and transporting the dismantled material over lead distance of about 1000Mtrs from the site as per the Departmental stores conditions and directed by as the engineer incharge
Point wiring in PVC conduit with modular type switch: Wiring for light point/fan point/exhaust fan point/call bell pont with 1.5sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed PVC conduit with modular switch, modular plate, ceiling rose suitable GI box and earthing the point with 1.5sq.mm FR PVC insulated copper conductor single core cable etc., as required. Group C
Wiring in existing conduit: Supplying and drawing following sizes of FRLSPVC insulated copper conductor single core cable in the existing surface/recessed steel/PVC condit as required. (i)3 x 1.5 sq. Mm
Wiring in existing conduit: Supplying and drawing following sizes of FRLSPVC insulated copper conductor single core cable in the existing surface/recessed steel/PVC condit as required. (ii)3 x 2.5 sq.mm
Wiring in existing conduit: Supplying and drawing following sizes of FRLSPVC insulated copper conductor single core cable in the existing surface/recessed steel/PVC condit as required. (iii)5 x 4 sq. Mm
Telephone Wiring in existing Conduit :Supplying and drawing following pair 0.5 sq mm FR PVCinsulated annealed copper conductor, unarmored telephonecable in the existing surface/ recessed steel/ PVC conduit asrequired. 1 Pair
S/F PVC Conduit: Supplying and fixing of following sizes of PVC conduit along with accessories in surface/recess cutting the wall and making good the same in case of recessed conduit and this work includes cleat welding and fixing with suitable size as required. 25mm
S/F Modular type switch / socket / fan regulator / call bell: Supplying and fixing of following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc., as required (i)5/6A One way Switch
S/F Modular type switch / socket / fan regulator / call bell: Supplying and fixing of following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc., as required (ii)15/16A One way Switch
S/F Modular type switch / socket / fan regulator / call bell: Supplying and fixing of following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc., as required (iii)3pin 5/6A socket outlet
S/F Modular type switch / socket / fan regulator / call bell: Supplying and fixing of following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc., as required (iv)6pin 16A/6A power socket outlet
S/F Modular type switch / socket / fan regulator / call bell: Supplying and fixing of following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc., as required (v)Telephone socket outlet
S/F Modular boxes, base & cover plate: Supplying and fixing of following size/modules, GI box along with modular base & cover plate for modular switches in recess etc., as required (i)8 Module
S/F Modular boxes, base & cover plate: Supplying and fixing of following size/modules, GI box along with modular base & cover plate for modular switches in recess etc., as required (ii)12 Module
S/F 'C' series MCB: Supplying and fixing 5 amps to 32 amps rating, 240/415 volts,"C" curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (i)Single pole
S/F 'C' series MCB: Supplying and fixing 5 amps to 32 amps rating, 240/415 volts,"C" curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (ii)Triple pole
Supplying and fixing of following ways surface/ recess mounting,vertical type, 415 volts, TPN MCB distribution board of sheet steel,dust protected, duly powder painted, inclusive of 200 amps tinnedcopper bus bar, common neutral link, earth bar, din bar formounting MCB's (but without MCB's and incomer ) as required. 8 way (4 + 24), Double door
Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holesin cubicle panel, making connections, etc. as required. 100Amp,30KA,FPMCCB
Supply of 1 x 22watts LED Tube fittings fixture with tube and complete set consisting all accessories etc., as required Type: TMC501PXT-LED22WP3241. Make:Philips
Installation, testing and commissioning of pre-wired, fluorescentfitting / LED Fittings compact fluorescent fitting/LED Fittings of all types, complete withall accessories and tube etc. directly on ceiling/ wall,including connection with 1.5 sq. mm FRLS PVC insulated, copperconductor, single core cable and earthing etc. as required.
Supply Installation, testing and commissioning of 36 Watt LED High Bay with injection molded high performance poly cobonate refractor suitable for use with LED lamp with all required accessories and wiring in recess /surface as required complete and as directed by the engineer incharge.Type: LWV11-36-CDL/RFRMake: Crompton
Supply Installation, testing and commissioning of Heavy - Duty Wall Mounting Air Circulators750mm (30'') sweep,1- Phase ,230Volts,50Hz, single speed ,3 Blades,1440 RPM with air delivery 400m3/minMake: Almonard
Supply of 3.5Cx240 Sq.mm aluminium armoured XLPE insulated under ground cable as per IS standards etc., as required and as directed by the engineer in charge. Make: - Havells / Finolex
Supplying and fixing TP sheet steel enclosure on surface/ recessalong with 16/25/32 A 415 V "C" curve TP MCB complete withconnections, testing and commissioning etc. as required.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3.5C X240 sq. mm (62mm)
Laying of one number PVC insulated and PVC sheathed / XLPEpower cable of 1.1 kV grade of following size in the existing masonry open duct as required. Upto 35 sq. Mm
Laying of one number PVC insulated and PVC sheathed / XLPEpower cable of 1.1 kV grade of following size in the existing masonry open duct as required. Above 185 sq. mm and upto 400 sq. mm
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thickincluding accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metrelong etc. with charcoal/ coke and salt as required.
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection / termination with GI thimble etc. as required.
Supplying and fixing 3 pin, 5 A ceiling rose on the existingjunction box/ wooden block including connections etc. As Required
Providing and fixing following rating and breaking capacity and pole MCCB in cubicle panel board including drilling holesin cubicle panel, making connections, etc. as required. 400 Amp,50KA,FPMCCB
Supply of following aluminium armoured XLPE insulated under ground cable as per IS standards etc., as required and as directed by the engineer in charge. Make: - Havells / Finolex (i)4CX6sq.mm
Supply of following aluminium armoured XLPE insulated under ground cable as per IS standards etc., as required and as directed by the engineer in charge. Make: - Havells / Finolex (ii)4CX16 Sq.mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. (i) 4 CX6 Sq.mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. (ii) 4C X 16 sq. mm (28mm)
Supply Installation, testing and commissioning of Flame proof 90 Watt LED High Bay suitable for use with LED lamp with all required accessories and wiring in recess /surface as required complete and as directed by the engineer incharge.Type:LLF61Make: FCG
FLP 4 way junction box with cable entry of ¾ inch ET provided with 4 dummies, suitable to IIA & IIB group, IP65, earthing for lighting
FLP Plug and socket combined unit with 32A three pole 5Pin suitable for three phase supply of FCG make WTH on/off switches & reset button suitable to IIA & IIB group
FLP Plug and socket combined unit with 16A single pole 3Pin suitable for single phase supply of FCG make WTH on/off switches & reset button suitable to IIA & IIB group
FLP Push button station 16A single pole 3Pin suitable for single phase supply of FCG make n suitable to IIA & IIB group
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Upto 35 sq. mm
RAMI REDDY KAKU
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .