Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.2 LAccepted-AOC 255 VILLAGE UGRA POST OFFICE BARA AMBALA HARAYANA PIN 134003 | AMBALA | AMBALA | HARYANA | 134003 | ₹23.2 L Quoted ₹23.9 L | L1 | Accepted-AOC AOC |
| 2 | L2₹24.8 LRejected-Finance H NO 597 SEONA ROAD RANJIT NAGAR PATIALA PB 147001 | PATIALA | PATIALA | PUNJAB | 147001 | ₹24.8 L | L2 | Rejected-Finance NOT BEING LOWEST |
| 3 | L3₹27.6 LRejected-Finance 300 STREET NO 10 PREM BASTI SANGRUR PB PUNJAB 148001 | SANGRUR | SANGRUR | PUNJAB | 148001 | ₹27.6 L | L3 | Rejected-Finance NOT BEING LOWEST |
| 4 | L4₹28.9 LRejected-Finance 44 NEAR DURGA MANDIR TRIPURI TOABA TRIPURI TOWN PATIALA 147004 PB | PATIALA | PUNJAB | 147004 | ₹28.9 L | L4 | Rejected-Finance NOT BEING LOWEST |
| Sl No | Description | Qty | Unit | u and v engineers and consultants L1 | Jawandha Enterprises L2 | Mohinder Pal and Sons L4 | krishna engineers L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling and lowering to ground for repair, inspecting defective of Window/Split type AC of capacity 1.5 and 2 Ton and re-installing the same after repair complete, testing and shifting to new locations if required as specified by Engr-in-Charge. Note: 1. Day to day complaints of different items should be attended within 12 hours and the equipment should be operational within 24 hours in case of Minor Complaints and within 72 hours for Major complaints. 2. Failure to attend the complaint within the prescribed time shall attract a penalty of Rs 100 per day per complaint. and Rs. 50 for subsequent days. 3. Decision of Accepting Officer will be final in case of fine payment | 60 | Each Job | 400 ₹24,000 | 1,000 ₹60,000 | 680 ₹40,800 | 400 ₹24,000 |
| 2.00 | Supply and replacement of compressor sealed unit suitable for Window Type ACs 1.5 Ton Capacity , reciprocating type flushing , vacuumising and hydration the system, leakage testing , welding/soldering as required and charging refrigerant gas, reinstalling in position and testing for the desired condition including replacement of strainer complete all as directed Make- Kirloskar/ Godrej/Tecumseh/LG | 3 | Each | 6,200 ₹18,600 | 8,000 ₹24,000 | 7,250 ₹21,750 | 7,500 ₹22,500 |
| 3.00 | Supply and replacement of compressor sealed unit suitable for Window Type ACs 1.5 Ton Capacity , Rotary type flushing , vacuumising and hydration the system, leakage testing , welding/soldering as required and charging refrigerant gas, reinstalling in position and testing for the desired condition including replacement of strainer complete all as directed Make- Kirloskar/ Godrej/Tecumseh | 8 | Each | 5,000 ₹40,000 | 7,000 ₹56,000 | 6,800 ₹54,400 | 8,000 ₹64,000 |
| 4.00 | Supply and replacement of compressor sealed unit suitable for Split Type ACs 1.5 Ton Capacity reciprocating type flushing , vacuumising and hydration the system, leakage testing , welding/soldering as required and charging refrigerant gas, reinstalling in position and testing for the desired condition including replacement of strainer complete all as directed Make- Kirloskar/ Godrej/Tecumseh | 1 | Each | 6,000 ₹6,000 | 9,000 ₹9,000 | 7,500 ₹7,500 | 8,000 ₹8,000 |
| 5.00 | Supply and replacement of compressor sealed unit suitable for Split Type ACs 1.5 Ton Capacity, rotary type flushing , vacuumising and hydration the system, leakage testing , welding/soldering as required and charging refrigerant gas, reinstalling in position and testing for the desired condition including replacement of strainer complete all as directed Make- Kirloskar/ Godrej/Tecumseh | 12 | Each | 5,200 ₹62,400 | 7,000 ₹84,000 | 6,900 ₹82,800 | 8,000 ₹96,000 |
| 6.00 | Supply and replacement of compressor sealed unit suitable for Split ACs 2 Ton Capacity ,reciprocating type flushing , vacuumising and hydration the system, leakage testing , welding/soldering as required and charging refrigerant gas, reinstalling in position and testing for the desired condition including replacement of strainer complete all as directed Make- Kirloskar/ Godrej/Tecumseh | 2 | Each | 6,500 ₹13,000 | 12,500 ₹25,000 | 9,550 ₹19,100 | 8,000 ₹16,000 |
| 7.00 | Supply and replacement of compressor sealed unit suitable for Split ACs 2 Ton Capacity ,rotary type flushing , vacuumising and hydration the system, leakage testing , welding/soldering as required and charging refrigerant gas, reinstalling in position and testing for the desired condition including replacement of strainer complete all as directed Make- Kirloskar/ Godrej/Tecumseh | 6 | Each | 5,500 ₹33,000 | 11,000 ₹66,000 | 8,950 ₹53,700 | 9,000 ₹54,000 |
| 8.00 | Material and labour for charging of gas in window type AC 1.5/2 Ton ( R-22/ R410A/R32) after flushing, vaccumising and dehydration as per laid down standard practice and existing model including replacement of strainer complete as directed. | 60 | Each Job | 1,400 ₹84,000 | 700 ₹42,000 | 805 ₹48,300 | 2,200 ₹1.3 L |
| 9.00 | Material and labour for charging of gas in split type AC 1.5/2 Ton ( R-22/ R410A/R32) after flushing, vaccumising and dehydration as per laid down standard practice and existing model including replacement of strainer complete as directed. | 80 | Each Job | 1,400 ₹1.1 L | 700 ₹56,000 | 890 ₹71,200 | 2,200 ₹1.8 L |
| 10.00 | Servicing of Air conditioners of window/ split type of any capacity 1.5/ 2 Ton by removing dirt and debries on all parts of air conditioner, washing and lubricating all moving parts complete by the manufacturer technician as directed by the Engr-In-Charge as per standard norms of the Manufacturer. Note :1. Lowering, dismantling, re-installing of air conditioners after reassembling the equipment in same/different position shall be included in the unit quoted rate.
2. Day to day complaints of different items should be attended within 12 hours and the equipment should be operational within 24 hours in case of Minor Complaints and within 72 hours for Major complaints. 3. Failure to attend the complaint within the prescribed time shall attract a penalty of Rs 100 per day per complaint. and Rs. 50 for subsequent days. 4. Decision of Accepting Officer will be final in case of fine payment | 200 | Each Job | 300 ₹60,000 | 200 ₹40,000 | 400 ₹80,000 | 300 ₹60,000 |
Updated dates
Tender Value
Refer Docs
EMD Value
₹77,440
Closing Date
8 Apr 2026, 6:00 pmClosed
MAJ MOHAMMED AQIL AZEEM
GE NORTH PATIALA MILITARY ENGINEER SERVICES SANGRUR ROAD PATIALA CANTT
REPAIR TO SUMMER APPLIANCES UNDER GE(NORTH) PATIALA
2026_MES_755876_1
GE (N)/TOKEN-106/2025-2026
Open Tender
Civil Works
210 days
PATIALA
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE N PATIALA
₹77,440
Yes
25 May 2026
11 Mar 2026
11 Apr 2026
11 Mar 2026
8 Apr 2026
25 Mar 2026
Dismantling and lowering to ground for repair, inspecting defective of Window/Split type AC of capacity 1.5 and 2 Ton and re-installing the same after repair complete, testing and shifting to new locations if required as specified by Engr-in-Charge. Note: 1. Day to day complaints of different items should be attended within 12 hours and the equipment should be operational within 24 hours in case of Minor Complaints and within 72 hours for Major complaints. 2. Failure to attend the complaint within the prescribed time shall attract a penalty of Rs 100 per day per complaint. and Rs. 50 for subsequent days. 3. Decision of Accepting Officer will be final in case of fine payment
Supply and replacement of compressor sealed unit suitable for Window Type ACs 1.5 Ton Capacity , reciprocating type flushing , vacuumising and hydration the system, leakage testing , welding/soldering as required and charging refrigerant gas, reinstalling in position and testing for the desired condition including replacement of strainer complete all as directed Make- Kirloskar/ Godrej/Tecumseh/LG
Supply and replacement of compressor sealed unit suitable for Window Type ACs 1.5 Ton Capacity , Rotary type flushing , vacuumising and hydration the system, leakage testing , welding/soldering as required and charging refrigerant gas, reinstalling in position and testing for the desired condition including replacement of strainer complete all as directed Make- Kirloskar/ Godrej/Tecumseh
Supply and replacement of compressor sealed unit suitable for Split Type ACs 1.5 Ton Capacity reciprocating type flushing , vacuumising and hydration the system, leakage testing , welding/soldering as required and charging refrigerant gas, reinstalling in position and testing for the desired condition including replacement of strainer complete all as directed Make- Kirloskar/ Godrej/Tecumseh
Supply and replacement of compressor sealed unit suitable for Split Type ACs 1.5 Ton Capacity, rotary type flushing , vacuumising and hydration the system, leakage testing , welding/soldering as required and charging refrigerant gas, reinstalling in position and testing for the desired condition including replacement of strainer complete all as directed Make- Kirloskar/ Godrej/Tecumseh
Supply and replacement of compressor sealed unit suitable for Split ACs 2 Ton Capacity ,reciprocating type flushing , vacuumising and hydration the system, leakage testing , welding/soldering as required and charging refrigerant gas, reinstalling in position and testing for the desired condition including replacement of strainer complete all as directed Make- Kirloskar/ Godrej/Tecumseh
Supply and replacement of compressor sealed unit suitable for Split ACs 2 Ton Capacity ,rotary type flushing , vacuumising and hydration the system, leakage testing , welding/soldering as required and charging refrigerant gas, reinstalling in position and testing for the desired condition including replacement of strainer complete all as directed Make- Kirloskar/ Godrej/Tecumseh
Material and labour for charging of gas in window type AC 1.5/2 Ton ( R-22/ R410A/R32) after flushing, vaccumising and dehydration as per laid down standard practice and existing model including replacement of strainer complete as directed.
Material and labour for charging of gas in split type AC 1.5/2 Ton ( R-22/ R410A/R32) after flushing, vaccumising and dehydration as per laid down standard practice and existing model including replacement of strainer complete as directed.
Supply only Front grill of window type AC with shutters as per existing model complete all specified and directed by EIC
Supply only 1/2'' and 1/4'' reverse valve for split AC valve as per existing model complete all as specified and directed by EIC . Make: Carrier Voltas LG ( Set of 2 )
Supply only suction valve size 3/8'' for 1.5/2 TR split AC complete all as specified and directed by EIC. Make: BAP/ TAK Cassel
Supply only delivery valve size 1/2'' for 1.5/2 TR split AC complete all as specified and directed by EIC. Make: BAP/ TAK Cassel
Supply only swing motor for 1.5/2 TR split AC indoor unit for any existing make complete all as specified and directed by EIC. Make: Carrier/LG/samsung/daikin
Supply and replacement of double shaft blower motor of size 1/10 HP for window Air Conditioner of capacity 1.5 Ton single phase 230 V, 1500 rpm complete all specified and directed by Engr-in-charge. Make- Crompton/Kirlosker suitable for AC of make fedder Lloyd/ Blue Star/ LG/ Carrier/Samsung
Supply and replacement of indoor/blower motor of size 1/10 HP for split Air Conditioner of capacity 1.5 Ton as per existing model of approved make.
Supply and replacement of Fan motor for split type Air Conditioner of capacity 1.5/2.0 Ton as per existing model of approved Make Voltas/LG/Samsung.
M&L for rewinding of blower motor double speed (high & low) with supper enamelled copper wire of proper gauge with and including rubber bush of capacity 1/10 HP motor for Window AC/ Split AC 1.5/2 Ton complete as directed.
Supply and fix Rolling type PVC Blower for indoor unit of split AC 1.5 / 2.0 Ton Capacity Make as per existing make as directed by EIC
Supply and fix Fan Blade for out door unit of split AC 1.5 /2.0 Ton Capacity make as per Existing
Supply and fix as in replacement flexible copper conductor cable 3 core, PVC insulated of size 70/.0076 and connected electrically to any electric devices/of any capacity size type & make etc complete all as specified and directed.Make:KEI,Plaza,Kalinga,Havells
Supply and Replacement of capacitor 6 mfd 230volts (+) 5% dry type complete suitable for window /split Ac motors as specified and directed. Make Tibcon/Elcap/
Supply and replacement of running capacitor 36 mfd complete as directed Make-TIBCON/SIEMENS or equivalent.
Supply and replacement of running capacitor 45/50 mfd complete as directed Make-TIBCON/SIEMENS or equivalent.
Supply and replacement of starting capacitor of size 100-120 MFD for Air Conditioner 1.5 to 2 Ton Capacity complete as directed Make-TIBCON/SIEMENS or equivalent.
Supply and replacement of box type relay type Model Sr-1622 forWindow/ Split Air Conditioner 1.5 Ton/2 Ton capacity as per sample approved by department complete all as directed. Make- MICROTECH/ HITECH .
Supply and replacement of PCB assembly of existing make for window type ACs 1.5 to 2.0 ton
Supply and replacement of PCB assembly of existing make for split type ACs 1.5 to 2.0 ton
Repair of PCB assembly of existing make for window type ACs 1.5 to 2.0 ton with remote control.
Repair of PCB assembly of existing make for split type ACs 1.5 to 2.0 ton with remote control.
Supply and fix PCB assembly of existing make for invertor Split AC as specified and directed by Engr-in-charge.
Repair of PCB assembly of existing make for invertor Split AC as specified and directed by Engr-in-charge.
Supply and fix PCB assembly of existing make for invertor Window AC as specified and directed by Engr-in-charge.
Repair of PCB assembly of existing make for invertor Window AC as specified and directed by Engr-in-charge.
Supply and fix indoor motor of Invertor AC window/ Split of existing make as specified and directed by Engr-in-charge
Supply and replacement of fan blade of window ACs of cap 1.5 to 2.0 ton complete as directed.
Supply and fix in replacement new fan motor in Window AC 1.5/2 Ton as specified and directed by EIC
Dismantling and lowering to ground for descaling of condenser with appropiate chemical to window/split type ACs of capacity 1.5 and 2 Ton and re-installing the same it original position testing complete all as directed.
Dismantling and lowering to ground for Repair of condenser with appropiate welding/ brazing, installing new condenser fins copper type for Window ACs of capacity 1.5/2 Ton and re-installing the same it original position testing complete all as directed.
Dismantling and lowering to ground for repair of condenser with appropiate welding/ brazing, installing new condenser fins copper type for Split ACs of capacity 1.5/2 Ton and re-installing the same it in original position testing complete all as directed.
Supply and fix PVC enclosures, single pole and neutral with a two pin and earth plug and socketed complete with one single pole MCB,s capacity 32 Amp /40 Amp 240Volts.
Supply only Thermostat switch 2059/2064/2054 for Window / Split type AC unit of cap 1.5 ton/ 2 ton. Make: Indfos
Supply only Copper filter double capillary pencil type for window/split type AC of cap 1.5 ton/ 2 ton complete all specified and directed.
Supply only wiring kit for AC window type 1.5/2 Ton
Supply only wiring kit for AC Split type 1.5/2 Ton
Supply only remote control hand set for existing Window type/ split type air conditioner ( Invertor or Non Invertor) of make LG/Samsung/Voltas/Bluestar and of cap 1.5/2 ton with pencil cells as per sample complete all as specified and directed.
Supply only air filter made of Ric/ Nylon suitable for window type AC 1.5/2 TR cap complete all as specified and as directed . Make: Samsung/LG/Voltas/carrier.
Supply only air filter made of Ric/ Nylon suitable for split type AC 1.5/2 TR cap complete all as specified and as directed . Make: Samsung/LG/Voltas/carrier.
Supply and replacement PVC pipe flexible type 20mm dia (including flexible clamps) for drain out waste water from Window/ split ACs.
Carrying out pressure leak test for 1.5/2 ton capacity window/split type AC by Nitrogen gas pressure for detecting the leakage in indoor cooling unit, referigerant pipe and repairing the leakage by welding or brazing, checking the leakage after repairing, flushing out nitrogen gas, vaccumisation complete all as specified and directed.
Supply and fix in renewal outdoor condensing unit of spilt type AC of capacity 1.5 TR capacity complete with condensing coil, coil frame, wiring kit, starting and running capacitors, relay condensing/ outdoor motor with blade complete all as specified and as directed. Make :- Opel/ Accent/ Skoda/ LG/ Carrier
Supply and fix in renewal of indoor unit of 1.5 TR capacity split type AC (Make: Omega/ ITC/ Totaline) with blower motor, front grill and connecting the copper tubing by brazing, detecting leakage, rectifying the same complete all as specified and as directed. Note : Supply and charging of refrigerant gas as required shall be measured and paid for separately.
Supply and fix in renewal outdoor condensing unit of spilt type AC of capacity 2 TR capacity complete with condensing coil, coil frame, wiring kit, starting and running capacitor, relay condensing/ outdoor motor with blade complete all as specified and as directed. Make :- Opel/ Accent/ Skoda/ LG/ Carrier
Supply and fix in renewal defective indoor unit of 2 TR capacity split type AC (Make: Omega/ ITC/ Totaline) with blower motor, front grill and connecting the copper tubing by brazing, detecting leakage, rectifying the same complete all as specified and as directed. Make :- Opel/ Accent/ Skoda/ LG/ Carrier Note : Supply and charging of refrigerant gas as required shall be measured and paid for separately.
Supply and fix in renewal for window AC comprising cooling, condensing unit, fan motor, Compressor 1.5 TR and electrical accessories, testing complete all in working condition as specified and as directed. Make: Opel/LG/Voltas/Viva. Note : Supply and charging of refrigerant gas as required shall be measured and paid for separately.
Dismantling and lowering to ground for repairs inspecting defects of water coolers of capacity 40/120/150 litres with cleaning, oiling greasing of all required parts etc and re-installing the same after repair and testing to the complete satisfaction of Engineer -in - Charge. Note: 1. Day to day complaints of different items should be attended within 12 hours and the equipment should be operational within 24 hours in case of Minor Complaints and within 72 hours for Major complaints. 2. Failure to attend the complaint within the prescribed time shall attract a penalty of Rs 100 per day per complaint. and Rs. 50 for subsequent days. 3. Decision of the Accepting Officer will be final in case of fine payment
Supply and replacement of compressor sealed unit for water cooler of size 40/80 litre including refixing the unit , supplying and charging gas after satisfactory leak testing including welding/soldering as required and commissioning complete all as directed. Make - Kirloskar/ Godrej/ Blue Star/Tecumseh
Supply and replacement of compressor sealed unit for water cooler of size 120 and 150 litre including refixing the unit , supplying and charging gas after satisfactory leak testing including welding/soldering as required and commissioning complete all as directed Make - Kirloskar/ Godrej/ Blue Star/Tecumseh
Material and labour for gas charging ( Freon-22/R134-a) to the water coolers of capacity 40/80 litres after satisfactory vacuum and pressure including replacement of strainer & testing all as directed.
Material and labour for gas charging ( Freon-22/R134-a) to the water coolers of capacity 120/150 litres after satisfactory vacuum and pressure including replacement of strainer & testing all as directed.
Supply and fixing of push cock 15 mm CP size for water coolers as per existing shape and size as directed. Make-KK/EKTA.
Supply and replacement of fan motor of condenser size 1/35 HP single phase 50 HZ 230 Volts for water cooler of capacity 40/80 Litre complete with blade as per existing model and connecting items complete all as specified my EIC (Make:FRAC MASTER/AIR MASTER
Supply and replacement of fan motor of condenser size 1/10HP single phase 50 HZ 230 Volts for water cooler of capacity 120/150 Litre complete with blade as per existing model and connecting items complete all as specified by EIC(Make:FRAC MASTER/AIR MASTER
Supply and replacement of fan blade for water cooler of capacity 40/80 Litre complete with blade as per existing model and connecting items complete all as specified my EIC
Supply and replacement of fan blade for water cooler of capacity 120/150 Litre complete with blade as per existing model and connecting items complete all as specified by EIC
Supply and replacement of relay for water cooler with OLP (Make MICROTECH/HITECH
Supply and replacement of Box type relay with OLP as per existing make
Supply and replacement of running capacitor 10 mfd/ 15 mfd (Make-TIBCON/SIEMENS)
Supply and replacement of running capacitor 25/36 mfd (Make-TIBCON/SIEMENS)
Supply and replacement of starting capacitor 40/60 mfd 230 volts complete as directed (Make- TIBCON /SIEMENS)
Supply and replacement of PVC float Valve suitable for 15 mm bore pipe (ISI marked) complete suitable for water coolers/desert coolers as per existing at site complete all as directed.
Supply and replacement of thermostat switch of water cooler complete as directed (Make- DASSPASS/ INDFOSS)
Cutting the rusted unserviceable base of 120/80/40 litre capacity, water cooler body, material and labour for fabrication of new base made of MS sheet and angle iron as per existing size and thickness incl welding of small patches as directed by engr in charge
Supply and fix in renewal, condensing coil for water cooler capacity 40/80 Litres of existing make of 22 Gauge MS sheet duly painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by EIC.
Supply and fix in renewal, condensing coil for water cooler capacity 60/120 Litres of existing make of 22 Gauge MS sheet duly painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by EIC.
Supply and fixing in replacement of complete top door made out of stainless steel 20 gauge sheet with handle and locking arrangement with double keys including door gasket, insulating material, PVC inner sheet of suitable thickness for 150/120/40 ltrs capacity water cooler as per existing size and shape, welding work, nuts, bolts and washers all as directed and specified by engr-in-charge.
Material and Labour for detecting any leakage from cooling and condensing coil fin of water cooler capacity 40/80 L of any make with the help of high pressure nitrogen gas and repairing the leakage by welding/brazing of cooling and condensing coils by disconnecting inclusing renewal of new filter, new capillary tube and testing the unit complete all as specified and directed by EIC
Material and Labour for detecting any leakage from cooling and condensing coil fin of water cooler capacity 120/150 L of any make with the help of high pressure nitrogen gas and repairing the leakage by welding/brazing of cooling and condensing coils by disconnecting inclusing renewal of new filter, new capillary tube and testing the unit complete all as specified and directed by EIC
Material and Labour for fixing of new water tank of 40/80 L cooling capacity including all outer side puffing for insulation complete all as specified and directed by EIC
Material and Labour for fixing of new water tank of 60/120 L cooling capacity including all outer side puffing for insulation complete all as specified and directed by EIC
Supply only rubber waste pipe/ drain pipe with clamps suitable for water cooler of any capacity complete all as specified and directed by EIC
Disconnecting and complete opening of voltage stabilizer of capacity up to 5KVA and removing the burnt out unserviceable parts and cleaning, material and labour for new parts, Rewinding with copper enamelled wire as per existing gauge complete all as specified and directed by EIC.
Rewinding with copper enamelled wire as per existing gauge complete all as directed of transformer assy of voltage stabilizer s of capacity up to 2 KVA.
Rewinding with copper enamelled wire as per existing gauge complete all as directed of transformer assy of voltage stabilizer s of capacity of 3 to 5 KVA.
Supply and replacement of boost/buck relay of voltage stabilizer of capacity up to 2 KVA.
Supply and replacement of boost/buck relay of voltage stabilizer of capacity up to 3 to 5 KVA.
Supply and replacement of cut out relay of suitable for up to 2 KVA
Supply and replacement of cut out relay of suitable for 3 to 5 KVA
Supply and replacement of Volt meter for voltage stabilizer suitable for 3 to 5 KVA
Supply and replacement of copper pipe heavy duty of size 5/8" all as specified and directed .
Supply and replacement of copper pipe heavy duty of size 3/8" all as specified and directed
Supply and fixing pipe insulation for copper pipe of size 5/8" and 3/8" all as specified and directed.
S&F Top Plug 3 Pin 5 Amps 230 Volts Make: Anchor/Plaza.
S&F Top Plug 3 Pin 15 Amps 230 Volts Make: Anchor/Plaza.
Supply and replacement of compressor sealed unit for refrigerator of size 165 to 220 Ltr cap with and including supplying and charging of gas and including welding/soldering for leak proof as required and commissioning complete all as specified and directed Make Kirloskar/Tecumseh/LG/Godrej/Whirlpool.
Supply and replacement of compressor sealed unit for refrigerator of size 270 to 310 Ltr cap with and including supplying and charging of gas and including brazing for leak proof as required and commissioning complete all as specified and directed Make Kirloskar/Tecumseh.
Supply and replacement of starting box type relay PVC 1/8 HP suitable for any make Refrigerator of size 165 to 310 Lts (Make TIBCON/SIEMENS)
Supply and replacement of starting box type relay PVC 1/6 HP for Refrigerator of size 310 Lts (Make TIBCON/SIEMENS/HITECH)
Supply and replacement of over load protector 1/6 HP for Refrigerator of size 165 to 310 Lts (Make TIBCON/SIEMENS/HITECH)
Supply and replacement of PCB assembly of existing make for referigerator of capacity 165 to 220 Ltr as per existing make.
Supply and replacement of PCB assembly of existing make for referigerator of capacity 260 to 310 Ltr as per existing make.
Supply and replacement of PTC relay of Refrigerator of 286/ 310 Lts (Make Godrej /Whirlpool)
Supply and replacement of refrigerant gas in the refrigerator & Deep Freezer including satisfactory leak proof and vacuum test of capacity 260 to 310 ltr including replacement of strainer as per existing model and direction of EIC.
Supply and replacement of refrigerant gas in the refrigerator & Deep Freezer including satisfactory leak proof and vacuum test of capacity 165 to 220 ltr including replacement of strainer as per existing model and direction of EIC.
Supply and fix for replacement of Freezer with door frame of refrigerator capacity 165 to 220 ltrs as directed by EIC
Supply and replacement of Freezer with door frame of refrigerator capacity 260 to 310 ltrs as directed by EIC
Supply and replacement of complete condenser assembly of refrigerator suitable for 286 to 310 ltrs of existing make.
Supply and replacement of complete condenser assembly of refrigerator suitable for 165 to 220 ltrs of existing make.
Supply and fix in renewal of copper capillary for referigerator of any capacity as per existing make as specified by EIC.
Supply and fix in renewal of dryer filter for referigerator of any capacity as per existing make as specified by EIC.
Supply and fix in renewal of drain water collector in referigerator of capacity 165 to 310 ltr as per existing model as directed and specified by EIC
Supply and replacement of door gaskets of refrigerator capacity 165 to 310 ltrs of existing make as directed and specified by EIC.
Supply and fixing Timer for Refrigerator of Cap 286 to 310 Lts.
Supply and replacement of fan motor of freezer of refrigerator 165ltr to 310 ltr.
Supply and replacement of axial fan motor of deep freezer 220 & 320 lts and ( 50/60 Hz) Size 120x120x38
Supply and fix door gasket suitable for 220/320 ltr deep freezer doors complete all as specified and directed
Supply and replacement of roll bond evaporator for for deep freezer of cap 220/320 Ltr
Supply and fix starting relay ISI marked for Deep freezer of capacity 220/320 ltr complete all as specified and directed
Supply and fix OLP ISI marked for Deep freezer of capacity 220/320 ltr complete all as specified and directed
Supply and fix thermostat ISI marked for deep freezer of capacity 220/320 ltr complete all as specified and as directed
Supply only starting capacitor 50 mfd ISI marked for deep freezer of capacity 220/320 Ltr complete all as specified and directed.Make: Asian/Sharda/unistar/tesla/epcos.
Supply and replacement of fan blade of referigerator of capacity 165 ltr to 310 ltr complete as specified and directed by EIC.
Supply and replacement of fan blade of Deep freezer of capacity 220 ltr complete as specified and directed by EIC.
Supply and replacement of compressor sealed unit for Deep Freezer of 220/320 Ltr cap with and including supplying and charging of gas and including brazing for leak proof as required and commissioning complete all as specified and directed by EIC. Make Kirloskar/Tecumseh.
Servicing of Water purifier of any description complete by the manufacturer technician as directed by the Engr-In-Charge as per standard norms of the Manufacturer. (Unserviceable spares shall be measured and paid separately) :- Note: 1. Day to day complaints of different items should be attended within 12 hours and the equipment should be operational within 24 hours in case of Minor Complaints and within 72 hours for Major complaints. 2. Failure to attend the complaint within the prescribed time shall attract a penalty of Rs 100 per day per complaint. and Rs. 50 for subsequent days. 3. Decision of Accepting Officer will be final in case of fine payment
Supply and Replacement of Candle/spun filter of RO water purifier
Supply and Replacement of inline Carbon filter for RO water purifier
Supply and Replacement sediment pre filter for RO water purifier
Supply only PVC pipe 1/4" dia for inlet / outlet water connection for RO water purifier
Supply and fix Suction/delivery RO motor
Supply and fix RO booster pump as per existing sample as specified and directed by EIC
Supply and fix RO membrane as per existing sample as specified and directed by EIC
Supply and fix SMPS adaptor for RO purifier as per existing make
Supply and fix RO Flow restrictor RO valve as per existing sample as specified and directed by EIC
Supply and fix solenoid valve for RO purifier as per existing make
Supply and fix RO filter tap as per existing make
Supply and fix RO Pre filter bowl as per existing make and model
Inspection visit of technical team for AC system comprises of Air cooled condensing unit of cap 11 TR qty 04 Nos. & Air handling units of Cap. 3000 CFM qty 02 Nos Following is included in the visit: 1. Servicing of the complete AC system including cleaning of Pre filters, fine filters and Hepa filters 2. The compressor and AHU will be checked for its proper functioning with electrical connections and if any defect is found, the same is to be informed. 3. Safety controls such as pressure cut outs will be tested with necessary tools and equipments for proper functioning and in case of any mal- functioning same need to be rectified after consultation with EIC. 5. Inspection of Electrical cabling, Electrical switch boards and electrical accessories connected with main incomer to the system and minor repairs in electrical panels to be done as directed and specified by EIC.
AHU components Air handling units of Cap. 3000 CFM qty 02 Nos exhaustive servicing including refrigerant coil/cooling coil cleaning, AHU coil cleaning, checking for any loose electrical connections, changing of thimbles etc if required separating the components and cleaning with vacuum cleaner and by using antibacterial/ antimicrobial solution. Lubricate and grease motor and blower bearing and Reassemble the components thereafter as per the direction of EIC. Each job includes cleaning of 2 AHU units.
Air Cooled 11 TR Condensing units ( 4 units) exhaustive servicing including coil cleaning with vacuum cleaner and by using antimicrobial solution , electrical connection inspection and cleaning of fan blades and repair and maintenance of fan motor etc. ( Note : 1 job includes cleaning of all four condenser units of 11 TR)
Replacement of coarse air Prefilters of size 600 x 600 x 50 mm . Coarse filter will be G4 washable filter ( 50mm deep) class having average arrestance of 85-98% for 10 microns size as per EN779 2002, after damper at mouth of supply.
Replacement of fine filters bag type fine filters of size 600 x 600 x 300mm. Fine filters will be F-7 filters (300 mm deep) Average effieciency 85-95% for 1 micron size as per EN 779 2002 standards.
M & L for removing of damaged portion of duct insulation and fixing new nitrile thermal insulation of thickness 15 mm for duct with aluminium laminated closed cell elastomeric insulation of thickness 9 mm for supply duct at AHU and exhaust duct at discharge, thereby making the duct surface free from dust etc using a thin film of insulation material all as per manufacturer's recommended adhesive. Both duct and insulation, keeping the insulation material under compression( without any stretching), seal all joints air tight etc complete all as specified and as directed by EIC.
Supply and replacement of line operated 3 phase AC motor IE2 of capacity 3.7 KW/ 5HP feq = 50+-5% Hz, IP 55 suitable for AHU operation at central AC Plant complete including necessary fitting & connection. CAT ref : MHCITGS+E154X7. Note: Contractor is advised to visit site to ascertain the specifications of AC motor as specified by EIC. Make: Havells ( existing make)
Rewinding of existing line operated 3 phase AC motor of capacity 3.7 KW/ 5 HP feq 50+-5%, IP 55 and removing the burnt out unserviceable parts and cleaning, material and labour for new parts, Rewinding with copper enamelled wire as per existing gauge complete all as specified and directed by EIC. (Make:Havells ( existing make)
Supply & installation of Calcium dryer as per existing make as directed by Engr-in-charge
Supply & installation of HEPA filters of size 880 x 610 x 150 mm as per existing
Supply & installation of V Belts for AHU blower as per existing make
Supply and fix AC Contactor of 32 Amp three phase as per existing make CAT No. MNX-A2.
Supply and fix MCB 3 pole 25 Amp as per existing make.
S & F MCCB, 4 Pole, 200 A, 25 KA for fixing in DB including proper thimble connection, thermal and magnetic release protection complete all as specified and directed by Engineer-in-charge.
Supply & charging of refrigerant R407c along with pressure testing with nitrogen & vaccum complete with all respect including rectification of leakage by welding as directed by Engr-in-charge
Supply and replacement of compressor sealed unit suitable for Split Type ACs 11 TR Capacity scroll type flushing , vacuumising and hydration the system, leakage testing , welding/soldering as required and charging refrigerant gas R407C, reinstalling in position and testing for the desired condition including replacement of strainer complete all as directed Make- Copeland. SNo: ZR144KF-TFD522
Rewinding of existing blower motor at exhaust at MH ICU of capacity 1 HP and removing the burnt out unserviceable parts and cleaning, material and labour for new parts, Rewinding with copper enamelled wire as per existing gauge complete all as specified and directed by EIC. (Make:( existing make)Note for Item No. 140 to 156 herein above:Above tems pertains to AC system installed at ICU in MH Patiala; The Bidder is advised to visit the plant prior quotation for checking of specification of existing AC Plant components incl AHU, Condensing Units, filters, electrical panels etc.
Material and Labour for servicing and Repair of commercial air curtain unit for prevention of Dust and conditioned air losses, single phase, 220 Volt, 50 HZ made out of MS/CRCA sheet of minimum thickness 18 Gauge finished with two coats of red oxide primer and final cost of synthetic enamel paint (over Baked) with MS CRC 18 Gauge square perforated suction grills, Aluminium alloy fans and single phase electric motor, nozzles etc complete with fittings and accessories so as to produce 1-1.5 m/sec air velocity at floor level for door opening as per existing model at the site as directed by EIC.Note: Note: Instrument to measure air velocity to be brought by the Contractor as per the approval of EIC.
Supply and fix 2800 RPM Motor fan assembly for air curtain as per existing make and model as per approval of EIC
Supply and fix 6x6 Blower wheel for air curtain as per existing make and model as per approval of EIC
Supply and fix Housing for air Curtains as per existing make and model as per approval of EIC
Supply and fix Magnetic proximity switch as per existing make and model as per approval of EIC
Supply and fix air curtain air filters as per existing make and model as pe approval of EIC
Replacement of Capacitor 4 mfd 230 Volts (+) 5 % dry type complete suitable for desert cooler all as specified and directed. Make- TIBCON/ELCAP/'AD/TORCON)
Painting of one coat of primer red oxide and two coat of super enamelled paint for Desert cooler and matching the same on the exterior colour by metal paste/puty and of any size/ make complete all as specified and directed.
Dismantling of desert cooler motor,(any make and type,taking out rotor removing all coils(burnt and alive)rewinding all the coils with suitable size super enamled copper wire(ISI marked) including all packing materials,insulating materials,varnishing greesing oils,reassembling,split pins, body blade screw and testing on full speed as per the direction of EIC complete all as specified and directed . Note: Cost of Replacement of UNSV gun metal bush and shaft for desert cooler shall be included under this item
Supply and fixing in replacement submersible PVC body Tulu pump suitable for desert cooler of any size complete all as specified and directed. Make- KHAITAN/COOL HOME/CG
Supply and fixing in replacement wood wool padding for desert coolers on all three sides ( for any size and type of cooler) complete all as specified and directed.Each set consists of 3 Pads
Supply and fixing flexible PVC transparent 15mm bore pipe set comprising one pipe from pump to PVC junction and 3 Nos short pieces of pipe from junction to shutter.
Supply and replacement of fan motor 1/10HP capacity suitable for desert cooler complete including necessary fitting & connection. Make:Khaitan/Cool home/Crompton Greaves
Supply and replacement of Desert Cooler body duly spray painted made out of 22 gauge MS sheet complete with front grill side shutters, control switch piano type 5 Amp speed regulator including lamp, wiring with suitable copper cable complete all connection
Supply and fixing in replacement of PVC front grill (Jali) suitable to existing size.
Supply and fix as in replacement flexible copper conductor cable 3 core, PVC insulated of size 70/.0076 with plug top and connected electrically to any electric devices/of any capacity size type & make etc complete all as specified and directed.
Supply & replacement of regulator knob type switch, 3 step control of speed of Desert cooler motor 230 volts, 50 Hz all as specified and directed.
S & F fan blade of existing size and make for desert cooler complete all as specified and directed by EIC
S & F Top Plug 3 Pin 5 Amps 230 Volts complete all as specified and directed.
S & F metallic frame with set of 4 legs as per model suitable for fixing/mounting fan motor of desert cooler with nuts, bolts, rubber etc., complete all as specified and directed.
S&F in replacement of PVC water distributer and elbow for desert cooler ( for any type and size of desert cooler) complete all as specified and directed.
Supply and replacement of PTMT Ball Valve suitable for 15 mm bore pipe complete suitable for desert cooler complete all as specified and directed.
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.70 MB
BOQ_846655.xls
BOQ • 0.46 MB
TENDERDOCUMENTS.pdf
Tender Documents • 2.12 MB
Download all tender documents and submit your bid