Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
Refer Docs
Closing Date
29 Aug 2022, 11:59 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Contracts & Procurement Department
Odisha
Rate contract for Supply, Installation, and Maintenance of Network Equipment’s (Router, Switches, Ba
TPWODL-RB-O-SER-082
TPWODL-RB-O-SER-082
Open Tender
installation
Tender Notice
Odisha
TP Western Odisha Distribution Limited (TPWODL)
Yes
Online / as specified in tender document
29 Aug 2022
24 Aug 2022
25 Aug 2022
Sl. No Specification Required Technical Specifications/ Make Offered/ Model Offered Remark (Amendment) Justification TPWODL's Response
1 Schedule of Items Supply & Installation of Aggregation Services routers , Industrial Router, Ethernet Switch, 42 U Rack & Ni-Cd Alkaline Battery with Battery Management System. All required Products are different OEM as compare to each other , the TENDER should be Re Published with Separate TENDER or Separate Participation for each line item 42U Rack , Ni-Cd Alkaline Battery & Router/switches This Tender is specific to particular OEM only to participate. Price Benefit/ Cartel for specific OEM with all Product Line can participate.Segegated Tender or separate participation for each Line Item (1) Switch & Router (2) 42 U Rack (3) Ni Cd Alkaline Battery. ensures Larger Participation, more transparency in Separate product line pricing , more OEM/ Vendor for (1) Switch & Router (2) Firewall (3) Ni Cd Alkaline Battery can participate with exorbitant price advantage for TPWODL. The Spec has been OEM generic as per technical reply on pre- bid. This is a SITC job and TPWODL is looking for a SI for end to end system integration.
2 Delivery The devices should be delivered within 2-3 weeks from the date of issuance of RO and installation of the should be done in 1 week from the the of Intimation. Separate Republished TENDER or separate participation for each line item (1) Router & Swtich ( 2) 42 U Rack (3) Battery with Charger . Separate Tender or separate participation for each line item. (1)Router & Switch (2) 42 U Rack (3) Battery Charger for faster delivery . Otherwise Delivery is at least 8-9 Months Lead time for specific OEM. The Spec has been OEM generic as per technical reply on pre- bid. This is a SITC job and TPWODL is looking for a SI for end to end system integration.
1.7 (B) The bidder should have average annual turnover of minimum of Rs. 20 Crores in last three financial years (FY-2019, 2020 and 2021). Copy of audited Balance Sheet and P&L Account to be submitted in this regard. The bidder should have average annual turnover of minimum of 10 cr in last three financial years (FY-2019,2020 and 2021). For Larger participation , please change this clause. Will be as per NIT
Qualification Requirement of Financial Turnover for MSME registered in the State of Odisha shall be reduced to 20% of the existing criteria The same benefit of MSME certificate should be given to PAN India Registered Vendor not only Odisha State. The MSME Certificate provided by Central Govt., as per the govt. rule MSME certificate benefit are same in PAN India. Will be as per NIT
Additional Point Qualification Requirement of Waiver for NSIC and MSME Their should be waiver of NSIC and MSME Certified Organization for EMD Amount as per Govertment of Indian Guidelines For Larger Participation and Govertment of India Guidelines Will be as per NIT
Payment Terms The bidder shall submit the invoices on completion of installation against each release Order basis and the payment shall be released within 45 days from the date of submission of certified bills/ Invoices. Being MSME we request you, the payment shall be released within 30 days against successful delivery and acceptance of Material. Will be as per NIT
Industrial Grade router
S. No. Technical Specifications Remark (Amendment) TPWODL's Response
1 Minimum packet forwarding rate of 200 Kbps for 64 byte packets The packet forwarding rate for 50Mbps router for 64 byte packet size is 74Kpps. Hence request to change this clause as "Minimum packet forwarding rate of 74 Kpps for 64 byte packets" May be considered as Minimum packet forwarding rate of 74 Kpps for 64 byte packets
2 At least 512 MB DRAM and 512 MB Flash.
3 Shall support high performance traffic forwarding at minimum 50 Mbps.
4 The router shall have enough CPU capacity and Memory so as to efficiently meet all the functionalities laid down in the specifications. The bidder should specify the offered CPU and memory model.
5 Router shall support 6/12 U rack mountings.
6 Router shall support Upgrade of Software through Flash Memory.
7 Router shall support on line software reconfiguration to implement changes without rebooting.
8 Router shall be capable of working with 10-60 volts DC
9 Router shall support a console port with RS-232 Interface for configuration and diagnostic purpose. Different OEMs have different way of providing console port, ranging from RS-232, RJ45, or USB. Request to amend the clause as "Router shall support a console port with RS-232/RJ45/USB Interface for configuration and diagnostic purpose."
10 The router must be modular. The router shall support 4 X 10/100/ switching module from Day 1 Different OEMs have different ways of making a router form-factor ranging from modular or fixed. Asking for only modular shall limit OEM participation. Hence request to amend the clause as : "The router shall support 6 X 10/100 BASE-T switching interfaces from Day 1" The router shall support 6 X 10/100 BASE-T switching interfaces from Day 1
11 2x10/100/1000 Base-T routable ports required from Day 1 A Router with forwarding capacity of 50Mbps does not justify 1000 Base-T interfaces. Asking for 1000 Base-T interfaces shall limit OEM participation. Also typically all the Base-T ports on a router should support switching (LAN) and routing (WAN) functions and not limiting some interfaces to LAN and some to WAN only. Hence request to amend the caluse as : "All the Base-T interfaces on the router should support be switching and routable ports, i.e. all the Base-T interfaces shall support LAN and WAN functionality" As per RFP
12 The router must have IPv6 feature from day 1
13 Gateway should have support for integrated fourth-generation (4G) wireless WAN capabilities from day one. It should be future 5G pluggable. Dual SIM support Should be provided from day one
14 Static routing, RIPv1/2, RIPng, OSPFv2 and v3, BGP4
15 Should be capable to work in L2 and L3 MPLS environment
16 Inter-VLAN routing
17 High availability: VRRP/HSRP
18 IGMP v1/2/3 & PIM-SM, PIM-DM, PIM SSM support Request to delete this clause The clause is optional now.
19 The router shall support following WAN protocol
20 Ethernet, 802.1q VLAN, Point-to-Point Protocol (PPP), Multilink Point-toPoint Protocol (MLPPP), Frame Relay, Multilink Frame Relay (MLFR), HighLevel Data Link Control (HDLC), Serial, Point-to-Point Protocol over Ethernet (PPPoE) and ATM (PPPoA) PPP, MLPPP, HDLC, PPPoE and PPPoA type of WAN protocols are required if the router has legacy interfaces like E1/T1, E3/T3, ch-STM-1/4. More over technologies like ATM and Frame-Relay are already discountinuted and not deployed in any networks today. Request to please modify the clause as "The equipment shall support IEEE 802.1Q (VLAN) and 802.1ad (QinQ) Layer-2 protocols" The equipment shall support IEEE 802.1Q (VLAN) and 802.1ad (QinQ) Layer-2 protocols
21 Security - The router shall support following Security features
22 PAP & CHAP as per RFC 1994. PAP and CHAP are authentication mechanism used over Serial links (Ex. E1/T1). The router asked in the tender is seeking 10/100BaseT Ethernet interfaces. PAP and CHAP are not applicable authentication protocols for Ethernet technology. Hence request to please delete this clause. The clause is optional now.
23 Data Encryption as per 3 DES and AES-256 standards. 3DES has shorter and weaker encryption keys compared to AES 3DES uses repeating encryption keys while AES does not. Hence it is recommended to use AES for data encryption. Request to change this clause to "The equipment shall support IPSec data encryption with AES-128 and AES-256 key" The equipment shall support IPSec data encryption with AES-128 and AES-256 key
24 Generic Routing Encapsulation as per RFC 2784. The ethernet wireless router should be able to support IP-MPLS based VPN (L3, L2) services for service based segregation and inherent security. IP-MPLS service over public/private wireless networks need to rely on tunneling technology namely MPLS over GRE. Generic routing encapsulation (GRE) tunnels are used to transport network layer packets over a Layer 3 network such as an LTE or WLAN interface. Hence request to change this clause with "The equipment shall support MPLS in GRE tunneling based on IETF RFC 4023" The equipment shall support MPLS in GRE tunneling based on IETF RFC 4023"
25 IP Sec based point to point secure tunnels.
26 Support for firewall features. Firewall is typically deployed in central office locations / data-center environments in order to secure internal networks from outside network. To secure data over WAN connectivity between access remote locations with central office / data-center, it is recomended to implement IPSec or equivalant technology. Asking for firewall features on remote access wireless routers shall limit OEM participation. Hence request to delete this clause. The clause is optional now.
27 Router should support Intrusion Prevention System feature. Similar to firewall, intrusion prevention system is typically deployed in central office locations / data-center environments in order to secure internal networks from outside network. This function can be clubbed with firewall and also called a next-generation firewall (NGFW). To secure data over WAN connectivity between access remote locations with central office / data-center, it is recomended to implement IPSec or equivalant technology. Asking for intrusion prevention system feature on remote access wireless routers shall limit OEM participation. Hence request to delete this clause. The clause is optional now.
28 Access lists
29 MD5 Route Authentication as per RFC 1321
30 Multiple Privilege levels to provide different levels of access
31 Router shall support following quality of Service (QoS) features
32 Weighted Fair Queuing(WFQ)
33 IP Precedence i.e. Priority based on TOS field of IP ver. 4
34 Differentiated services (Diff. serve) i.e. priority based on DS Fieldof the IP ver.4
35 Management: Telnet, SSHv2, SNMP v3, DHCP, RADIUS, TACACS+
36 Monitoring: Syslog, Statistics, RMON, Alarm Different OEMs have different way of monitoring the router health and statistics. Request to amend the clause as "Monitoring: Syslog/ Statistics/RMON/Alarm" Monitoring: Syslog/ Statistics/RMON/Alarm
37 Configuration rollback and pre-planned scheduled reboot facility
38 USB / RJ-45 based console port and auxiliary port for management Different OEMs have different way of monitoring the router through local access. Request to amend the clause as "USB / RJ-45 based console-port/auxiliary-port for management" USB / RJ-45 based console-port/auxiliary-port for management. Bidder has to provide at least 10 percent Console cables of the routers delivered.
39 Safety, EMI/EMC, FCC and NDPP certification compliance Different OEMs follow different certification/compliance tracks based on industry standards and standards based globally renowned compliance/certification agencies. Request to amend the clause as "Safety , EMI/EMC , FCC and NDPP/EAL3+ certification compliance" Safety, EMI/EMC, FCC and NDPP certification compliance or equivallent
40 Minimum R Humidity: 10 to 85% non-condensing
41 Mounting: Mounting DIN-Rail or Rack Mounting
42 Gateway should support DNP3 serial-to-DNP3/IP and IEC 60870 T101-to-T104 protocol translations.
43 Gateway should Comply with IEEE 1613 and IEC 61850-3 standards
44 Gateway should be ruggedized & modular in nature with minimum IP30 or above certification. Different OEMs have different ways of making a router form-factor ranging from modular or fixed. Asking for only modular shall limit OEM participation. Hence request to amend the clause as : "The router shall be designed to support minimum IP-40 and have an enclosure option to support IP-65. it shall be fanless and passively cooled" The router shall be designed to support minimum IP-40 and have an enclosure option to support IP-65. it shall be fanless and passively cooled
Sl. No Specification Required Technical Specifications/ Make Offered/ Model Offered Remark (Amendment) TPWODL's Response
1 Please mention Make, Model No. and Part Code
2 Type of Switch Managed Ethernet Switch
3 Type of Device Layer 2 Industrial Grade Switch
4 Number of Ethernet Ports (RJ45 Ports) Min of 16 Port
5 Speed of Ethernet 10/100T X RJ45 Request to change the clause to "mimimum 10 nos. of 10/100/1000 Base-T RJ45, 4 nos. of 1000 Base-X SFP, and 2 nos. of 1/10GE (dual rate) SFP ports" AS Per RFP
6 Power Supply Dual Redundant 10-60 VDC Plug- in Terminal Block
7 Mounting Mounting DIN-Rail or Rack Mounting
8 Operating Temperature -5° to +85°C. Request to change the clause of "-40°C to 70°C" -40°C to 70°C
9 Ambient Relative Humidity 5~95% (Non-condensing)
10 Communication Protocol IEC61850-3, IEEE1613 Standards
Environmental Compliance as per :
Test Description
11 IEC 60068-2-1 Cold Temperature
12 IEC 60068-2-2 Dry Heat
13 IEC 60068-2-30 Humidity (Damp Heat, Cyclic)
14 IEC 60068-21-1 Vibration Request to change the clause to "IEC 60068-21-1 / 60255-21-2, or equivalent" IEC 60068-21-1 / 60255-21-2, or equivalent"
15 IEC 60068-21-2 Shock Request to change the clause to "IEC 60068-21-2 / 60255-21-2, or equivalent" IEC 60068-21-2 / 60255-21-2, or equivalent"
• Management throughConsole, Web-based, Telnet, CLI Request to change the clause to "Management through Console, Web-based/GUI, Telnet, CLI" Management through Console, Web-based/GUI, Telnet, CLI"
• Supports SNMP Server v1.0/v2.0/v3.0
• Supports Remote Monitoring (RMON)
• Supports software upgradeby SFTP/HTTP Request to change the clause to "Supports software upgradeby SFTP/HTTP/TFTP/FTP or equivalent" Supports software upgradeby SFTP/HTTP/TFTP/FTP or equivalent
• Supports STP/RSTP/MSTP
• Supports Multicast Request to delete this clause The clause is optional now
• Supports SNTP Client Request to change the clause to "Supports SNTP / NTP Client" Supports SNTP / NTP Client"
• Diagnostics with logging and alarms
• LED indicators for link establishment and data transfer for each port
Supports Modbus/TCP Request to delete this clause The clause is optional now
17 Network Security: • Supports HTTPS/SSL Request to delete this clause The clause is optional now
• Supports TACACS+
• Supports IEEE802.1X
• Supports RADIUS
• Supports User Classification
Supports MAC address binding with switch ports
Product Conformity
18 Acc. to IEEE 802.3-10BaseT Yes
19 Acc. to IEEE 802.3u-100BaseTX Yes
20 Acc. to IEEE 802.3u-100BaseFX Yes Request to delete this clause The clause is optional now
21 Acc. to IEEE 802.3ab-1000BaseT Yes
22 Acc. to IEEE 802.3ad-Link Aggregation Yes
23 Acc. to IEEE 802.3x-Flow Control Yes Request to delete this clause The clause is optional now
24 Acc. to IEEE 802.1d-MAC Bridges Yes
25 Acc. to IEEE 802.1d-STP Yes
26 Acc. to IEEE 802.1p-Class of Service Yes
27 Acc. to IEEE 802.1Q-VLAN Tagging Yes
28 Acc. to IEEE 802.1Q-2005 (formerly IEEE 802.1s) MSTP Yes
29 Acc. to IEEE 802.1w-RRST Yes
30 Acc. to IEEE 802.1x-port based Network Access Control Yes
31 Switch Latency Period 6 ms
32 Transfer rate of the Switch 50.4 Gbit/s
33 Mode Store and Forward ok
34 Protection Class IP40
35 Conformal Coating Yes Request to delete this clause The clause is optional now
37 Warranty 5 Years
38 Authorized Repair Center of original Ethernet Switch manufacture in India Yes
S. No. Technical Specifications/Make Offered/Model Offered Remark (Amendment) TPWODL's Respnose
1 The router shall have enough CPU capacity and Memory so as to efficiently meet all the functionalities laid down in the specifications. The bidder should specify the offered CPU and memory model.
2 Router shall support 6/12/42 U rack mountings.
3 Router shall support Upgrade of Software through Flash Memory.
4 Router shall support on line software reconfiguration to implement changes without rebooting.
5 Router shall support a console port with RS-232 Interface for configuration and diagnostic purpose.
6 Router should have 1 Gbps & 10 Gbps active ports from day 1
7 The router must have IPv6 feature from day 1
8 Static routing, RIPv1/2, RIPng, OSPFv2 and v3, BGP4, RIPv1/2 and RIPng are legacy protocols based on distance vector algorithm. Distance vector alorithm based RIP protocol suffers from below drawbacks. 1. RIP has a maximum hop count of 15. Hence not scalable for big networks. 2. It is only based on hop count only. If there is a better route available with better bandwidth then it will not select that route. 3. RIP has high recovery/convergence time compared to OSPF. Based on the above mentioned drawbacks, it is highly recomened not to consider RIPv1/2 and RIPng feature. Request to change the clause as "Static routing OSPFv2 and v3, BGP4," Static routing OSPFv2 and v3, BGP4,"
9 Should be capable to work in L2 and L3 MPLS environment, Inter-VLAN routing
10 To include ‘Input Voltage requirement of 230VAC (± 5%)’.
11 High availability: VRRP/HSRP
12 IGMP v1/2/3 & PIM-SM, PIM-DM, PIM SSM support
13 The router shall support following WAN protocol
14 Ethernet, 802.1q VLAN, Point-to-Point Protocol (PPP), Multilink Point-to-Point Protocol (MLPPP), Frame Relay, Multilink Frame Relay (MLFR), High-Level Data Link Control (HDLC), Serial, Point-to-Point Protocol over Ethernet (PPPoE) and ATM (PPPoA) Technologies like ATM and Frame-Relay are already discountinuted and not deployed in any networks today. Request to please modify the clause as "Ethernet, 802.1q VLAN, Point-to-Point Protocol (PPP), Multilink Point-to-Point Protocol (MLPPP), High-Level Data Link Control (HDLC), Serial" Ethernet, 802.1q VLAN, Point-to-Point Protocol (PPP), Multilink Point-to-Point Protocol (MLPPP), High-Level Data Link Control (HDLC), Serial
Security - The router shall support following Security features
1 PAP & CHAP as per RFC 1994. PAP and CHAP are authentication mechanism used over Serial links (Ex. E1/T1). The router asked in the tender is seeking 1Gigabit Ethernet and 10Gigabit Ethernet interfaces. PAP and CHAP are not applicable authentication protocols for Ethernet technology. Hence request to please delete this clause. The clause is optional now
2 Data Encryption as per 3 DES and AES-256 standards.
3 Generic Routing Encapsulation as per RFC 2784. The ethernet wireless router should be able to support IP-MPLS based VPN (L3, L2) services for service based segregation and inherent security. IP-MPLS service over public/private wireless networks need to rely on tunneling technology namely MPLS over GRE. Generic routing encapsulation (GRE) tunnels are used to transport network layer packets over a Layer 3 network such as an LTE or WLAN interface. Hence request to change this clause with "The equipment shall support MPLS in GRE tunneling based on IETF RFC 4023" The equipment shall support MPLS in GRE tunneling based on IETF RFC 4023
4 IP Sec based point to point secure tunnels.
5 Router should support Intrusion Prevention System feature. Intrusion prevention system is typically deployed in central office locations / data-center environments in order to secure internal networks from outside network. This function can be clubbed with firewall and also called a next-generation firewall (NGFW). To secure data over WAN connectivity between access remote locations with central office / data-center, it is recomended to implement IPSec or equivalant technology. Asking for intrusion prevention system feature on remote access wireless routers shall limit OEM participation. Hence request to delete this clause. The clause is optional now
6 Access list Control
7 MD5 Route Authentication as per RFC 1321
8 Multiple Privilege levels to provide different levels of access
9 Router shall support quality of Service (QoS) features
10 Weighted Fair Queuing(WFQ)
11 IP Precedence i.e. Priority based on TOS field of IP ver. 4
12 Differentiated services (Diff. serve) i.e. priority based on DS Field of the IP ver.4
13 Management: Telnet, SSHv2, SNMP v3, DHCP, RADIUS, TACACS+
Configuration rollback and pre-planned scheduled reboot facility
1 USB / RJ-45 based console port and auxiliary port for management Different OEMs have different way of monitoring the router through local access. Request to amend the clause as "USB / RJ-45 / RS-232 based console-port/auxiliary-port for management" USB / RJ-45 / RS-232 based console-port/auxiliary-port for management
2 Safety, EMI/EMC, FCC and NDPP certification compliance Different OEMs follow different certification/compliance tracks based on industry standards and standards based globally renowned compliance/certification agencies. Request to amend the clause as "Safety , EMI/EMC , FCC and NDPP/EAL3+ certification compliance" Safety , EMI/EMC , FCC and NDPP/EAL3+ certification compliance
3 Minimum R Humidity: 10 to 85% non-condensing
4 Mounting: Mounting DIN-Rail or Rack Mounting
5 Gateway should support DNP3 serial-to-DNP3/IP and IEC 60870 T101-to- T104 protocol translations.
6 Gateway should Comply with IEEE 1613 and IEC 61850-3 standards
7 Gateway should be ruggedized & modular in nature with minimum IP30 or above certification. Request to change this clause to "Gateway should be conformal coated & modular in nature with normal operating range of -40°C to +65°C sustained." Gateway should be conformal coated & modular in nature with normal operating range of -40°C to +65°C sustained."
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
listing-row.html
html • 0.00 MB
910d67bd93a343318f9751bc1bd10557.xlsx
xlsx • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .