Loading…
Loading…
Tender Value
₹16.2 Cr
EMD Value
₹32.3 L
Closing Date
18 Aug 2026, 3:00 pm
Yes (up to 3 members)
No
Two Packet System
Normal Tender
Yes
27/07/2026 11:00
Lowest to Highest
90 days
Expenditure
Capital (Works)
HQ TENDER
16 conditions · 5 needing a document upload
Financial Eligibility criteria as per para 2.5.3 of Tender Document.
Bid Capacity: Refer para 2.5.4 of Tender Document
Similar Nature of work as per para 2.5.1 of Tender Document.
Technical Eligibility as per para 2.5.2 of Tender Document.
Documents to be submitted along with tender as per para 14 of GCC.
3 conditions · 2 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Format for self certification Regarding local content for Telecom products, services or works certificate (Form-1) as per DoT Notification No.18-10/2017-IP dated 29th August 2018 must be submitted by the tenderer and the concerned OEM for all Telecom products and for overall tender as Annexure-4
Tender specific authorization certificate (MAF) from the OEM (IPMPLS routers) is required for the bidder to participate in the bid. Note: Bidder should submit this authorization certificate issued by the OEM (IP-MPLS) with the bid otherwise the offer/bid will be summarily rejected.
Provision of Telecom assets with IP-MPLS based technology at Balance stations of Southern Railway
HQ_MAS_IPMPLSBalstns_02
HQ_MAS_IPMPLSBalstns_02
Open
Works - General
9 Months
Chennai, Tamil Nadu
₹0
₹32.3 L
15 Jul 2026
15 Jul 2026
4 Aug 2026
27 Jul 2026
37 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 16,16,12,594.64 | ||
| — | — | — | Above/ 118896036.00 Below/P | ||
| Design, Fabricate, Supply, installation, configuration, testing and commissioning of Label Edge Router (LER) as per RDSO Technical Advisory Note (TAN) No. STT/TAN/IP-MPLS/2020 Ver 3.0, Amd-1 or latest with non-blocking throughput of 160 Gbps full duplex or higher. The router should have console and SNMP interface, FAN Modules, Dust Filters, Dual main control card modules in redundant design supporting 1:1 hot stand by mode. Redundant 48V DC power supply modules etc., including connecting cables and fixing accessories from day one. The IP-MPLS router should support minimum 8x10G, 32x1G, 2xSTM1 and 2x16E1 CES interface (G.703) modules.The Router should be equipped with following interface cards and modules. (i) 4 x 10G (Optical) interface equally distributed in two cards, each minimum 2X10G SFP+ interface card, along with 4 no.of 10 G (40KM) SFP+ modules fully loaded suitable for single fiber as per site requirement. (ii) 8 x 1GbE optical interface equally distributed in two cards, each minimum 4X1GbE interface card, along with 8 no.of 1 GbE (10KM) SFP modules fully loaded. (iii) 4 X 1GbE copper interface card to connect various networks of station (iv) 16 x E1(G.703) interface equally distributed in two cards each minimum 8x E1(G.703) interface card. (Inspection by RDSO). This also include "Installation of switches, with power distribution panel and all accessories in the Rack (19") , DDF, Aluminum runway ladder, necessary ofc patch cord etc and their testing and commissioning. This also includes termination of all E1's on DDF, connection of pigtails, optical patch cords, CAT6 Cable and 48 V bus to the IPMPLS equipment including supply of wires and connectors. It also includes proper mounting of rack, provision of Aluminum runway ladder, casing and capping and conduit pipe as per requirement at each station and other necessary materials supplied by Railways from Stores for installation. (Conduit pipe/casing and capping with ISI standards, aluminum runway ladder, Optical patch cords and UTP patch cords and all other miscellaneous materials should be supplied by the contractor). | — | 140.00 | — | — | |
| — | — | — | Above/ 389600.00 Below/P | ||
| "Supply of 4 port x 10G SFP+ interface module card suitable for the IP MPLS router (The card should be compatible and suitable with existing system available in section) ( Inspection by RDSO )" | — | 20.00 | — | — | |
| — | — | — | Above/ 467520.00 Below/P | ||
| "Supply of 8 port x 1GbE (4 nos of optical ports and 4 nos of electrical ports) interface module card suitable for the IP-MPLS router (The card should be compatible and suitable with existing system available in section)( Inspection by RDSO )" | — | 20.00 | — | — | |
| — | — | — | Above/ 989584.00 Below/P | ||
| "Supply of 16 port channelized E1 interface card suitable for the IP-MPLS router (The card should be compatible and suitable with existing system available in section) ( Inspection by RDSO )" | — | 20.00 | — | — | |
| — | — | — | Above/ 432199.44 Below/P | ||
| Supply of SFPs for 1Gbe (optical)/RJ 45 ports as per the site requirement (Inspection by RITES) | — | 72.00 | — | — | |
| — | — | — | Above/ 859068.00 Below/P | ||
| Supply of SFP + 10G (40 km) SMF, 1550 nm for 40 km transmission working on single fibre (Inspection by RITES) | — | 36.00 | — | — | |
| — | — | — | Above/ 364700.00 Below/P | ||
| Supply of DDF (120 Ohms) for terminating 16 E1s of wrapping type and mountable on 19"" rack, similar to puncom or reputed make. (Maximum width 2U size) (Inspection by Consignee) | — | 140.00 | — | — | |
| — | — | — | Above/ 3605600.00 Below/P | ||
| Supply and installation of fully covered 19'' Racks of size 2200 mm X 600 mm 600mm complete with all fittings including DC Fans (48 V) -2Nos, with air filters at the sides. Separate or sheet/plate to keep testing equipment's - 1 No and AC Power distribution panel(horizontal fitting) with power sockets and fuse/MCB protection (minimum 6 Nos of 230V- 15A/5A. combined) and Earth Strip and other accessories. Rack should have compatibility with all equipment conforming to DIN41494 or equivalent EIA/ISO/EN standard, Manufacture must certify that products are complied with DIN41494 or equivalent EIA/ISO/EN/CEA/UL standards(Inspection by RITES) | — | 100.00 | — | — | |
| — | — | — | Above/ 12970900.00 Below/P | ||
| Supply of VRLA fully charged battery 48 V DC /300 AH (stackable) as per IRS:S- 93/96(A)(amd-1) or latest.(Inspection by RDSO) | — | 100.00 | — | — | |
| — | — | — | Above/ 11478700.00 Below/P | ||
| Supply of 25A, 48 V (2+1) FR/FC module RDSO /SPN/TC/23/1999 or latest with AC input range 90-300 Volts, (Inspection by RDSO) | — | 100.00 | — | — | |
| — | — | — | Above/ 325500.00 Below/P | ||
| Supply and installation of DC Power distribution panel to cater DC power requirements of IPMPLS/STM Multiplexers /PD Muxes / EOW /FANS to be fixed in 19"" rack with inbuilt line filter & Surge protection on 48V DC to be catered the demand of the load. The materials should be ISI certified or reputed make. (Minimum 8 Nos of DC distribution arrangement with MCB's of suitable rating for -ve. Connecting copper strip for +ve) (Inspection by Consignee) | — | 100.00 | — | — | |
| — | — | — | Above/ 1561700.00 Below/P | ||
| Installation, wiring and testing of battery sets and battery chargers for optic fibre circuits. This includes installation of AC and DC power supply distribution board with MCB's of suitable rating, wiring of external alarm contacts, Fixing arrangements for battery and charger in the equipment room with 25 sq.mm Multistrand single core Copper cable PVC insulated from Battery charger to Battery with suitable copper lugs crimped/soldered to it, 16 sq.mm Multistrand single core Copper cable PVC insulated from battery charger to power distribution panel in the rack with suitable copper lugs crimped/soldered to it. Connection from Battery charger body and battery +ve terminal to Earth terminal by 16 Sq.mm Multistrand single core Copper cable PVC insulated separately with suitable copper lugs crimped/soldered to it and Extension of AC 230V power supply wiring through PVC pipe with 6 sqmm cu. wire for phase & neutral and 1 sqmm cu .wire for earth to the 19" rack (Copper cables , 20A metal clad with MCB for AC supply to fix in the wall, conduits and other miscellaneous materials required for the work should be supplied by the contractor).(Inspection by Consignee). All materials should be ISI certified or reputed make. This work also includes transportation of materials from stores/ supplied by Railways for installation. | — | 100.00 | — | — | |
| — | — | — | Above/ 332802.00 Below/P | ||
| Supply of Tool Kit consisting of Optical power meter, Digital Multimeter, Ethernet Crimping Tool, LAN tester, Krone tool, Rapping Tool, Universal Spanner Set, Screw Driver Set (7 Pieces set), Cutting plier, Wire Stripper. as per Spec in the Tender document with OEM test report and warranty certificate (inspection by CONSIGNEE ) All the materials should be ISI certified or reputed make | — | 18.00 | — | — | |
| — | — | — | Above/ 3552000.00 Below/P | ||
| Supply of optical time Domain Reflectometer with VFI (OTDR) as per Spec in the Tender document with OEM test report and warranty certificate of reputed make like EXFO 735D or latest of better make (inspection by RITES ) | — | 12.00 | — | — | |
| — | — | — | Above/ 64268.80 Below/P | ||
| Supply of optical patch cords with FCPC/SCPC to SCPC/LCPC connecters (10 mtrs long), so as to suit OFC terminations and the IPMPLS equipment supplied. (Inspection by CONSIGNEE). All materails should be ISI certified or reputed make | — | 640.00 | — | — | |
| — | — | — | Above/ 4567354.40 Below/P | ||
| Supply of 10G SFP+ Module with 80 Km range for above Routers as per technical specification (Inspection by RITES) | — | 140.00 | — | — | |
| — | — | — | Above/ 496465.00 Below/P | ||
| Transportation of light materials/men with tools, documents from central location to the work spot and back. | — | 250.00 | — | — | |
| — | — | — | Above/ 258597.00 Below/P | ||
| Training of Railway staff at the factory premises of manufacturer of IP-MPLS equipment (or) at a reputed training institution as approved by railway executive InCharge. This includes boarding and lodging charges. (Travel expenses will be borne by the railways). | — | 15.00 | Man-Week | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
SignedPOCguidelines.pdf
ATTACHMENT
TANVersion3.0.pdf
ATTACHMENT
GCCwithACSupto11_compressed.pdf GCC with ACS
ATTACHMENT
Listofbalancestations.pdf
ATTACHMENT
LocalContentgazatte.pdf
ATTACHMENT
NetworkmapIPMPLS.pdf
ATTACHMENT
POCformat.pdf
ATTACHMENT
TrustedTelecomportal_1.pdf
ATTACHMENT
SimilarnatureofworkforIP-MPLS.pdf
ATTACHMENT
IPMPLS TENDER DOCUMENT
ATTACHMENT
GCCwithACSupto11_compressed.pdf
ATTACHMENT
IP-MPLSTenderDocument15072026.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].