Fire fighting, Pumps, electrical and waterproofing works etc
NBCC/ED/IOC/NIT/2026/917
NBCC/ED/IOC/NIT/2026/917
Open Tender-Domestic
Miscellaneous
New Delhi, Delhi
₹11,800
₹1.6 L
3 Jul 2026
3 Jul 2026
13 Jul 2026
13 Jul 2026
Providing and laying integral cement based treatment for water proofing on horizontal
surface at all depth below ground level for under ground structures as directed by
Engineer-in-Charge and consisting of : (i) Ist layer of 22 mm to 25 mm thick approved
and specified rough stone slab over a 25 mm thick base of cement mortar 1:3 (1
cement : 3 coarse sand) including applying of twice ( at base and top of mortar )
cement slurry @ 2.2kg/m2 (each time) mixed with water proofing compound
conforming to IS:2645 in the recommended proportion over the leveling course
(leveling course to be paid separately). Joints sealed and grouted with cement slurry
mixed with water proofing compound. (ii) 2nd layer of 25 mm thick cement mortar 1:3
(1 cement: 3 coarse sand) mixed with water proofing compound in recommended
proportions. (iii) Finishing top with stone aggregate of 10 mm to 12 mm nominal size
spreading @ 8 cudm/ sqm thoroughly embedded in the 2nd layer.
22.1.1 Using rough kota stone. sqm 150 1515.6 227340
Water proofing roof of Pump room
Providing and laying water proofing treatment on roofs of slabs by applying cement
slurry mixed with water proofing cement compound consisting of applying: (a) after
surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water
proofing cement compound @ 0.253 kg/sqm.
(b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps
of joints of fibre cloth should not be less than 10 cm.
22.6 (c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm sqm 490 688.92 337570.8
mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @
1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for
48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked
into groove in parapet all around.
(d) fourth and final layer of brick tiling with cement mortar (which will be paid for
separately. For the purpose of measurement the entire treated surface will be
Providing and laying integral cement based water proofing treatment including
preparation of surface as required for treatment of roofs, balconies, terraces etc
consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75
kg/sqm of cement admixed with water proofing compound conforming to IS. 2645
and approved by Engineer-in-charge over the RCC slab including adjoining walls upto
300 mm height including cleaning the surface before treatment. (b) Laying brick bats
with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement
mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound
conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of
cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing
compound conforming to IS : 2645 and approved by Engineer-in-charge to required
slope and treating similarly the adjoining walls upto 300 mm height including rounding
of junctions of walls and slabs. (c) After two days of proper curing applying a second
coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing
compound conforming to IS : 2645 and approved by Engineer-in-charge. (d) Finishing
the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse
sand) admixed with water proofing compound conforming to IS : 2645 and approved
by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer
of plaster and finally finishing the surface with trowel
Plaster of Paris
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface
prepare the surface even and smooth complete.
Painting with synthetic enamel paint of approved brand and manufacture of required
to give an even shade
Wiring for group controlled (looped) light point/fan
point/exhaust fan point/ call bell point (without
independent switch etc.) with 1.5 sq. mm FRLS/HFFR
1.54 PVC insulated copper conductor single core cable in
surface/ recessed steel conduit, and earthing the
point with 1.5 sq. mm FRLS/HFFR PVC insulated
copper conductor single core cable etc. as required.
1.54.3 Group A Point 5 914 4570
Digitally signed by AMIT
LED Batten light (System lumen efficacy ≥105 <120
lm/Watt). Supplying, Installation, Testing & Commissioning of LED surface mounted
Batten light of following body material and construction as per IS : 10322 with driver
(Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage
AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal
surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P.
F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver
& electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen
maintained till life
8.9 ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard
Deviation Colour Matching) <3, Maximum power consumption should not more than
the specified rating and Fixture shall be of relevant BIS standard.
Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing.
complete in all respect i/c external connections with 1.5 sq
mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as
required with Minimum 5 year OEM warranty. System lumen
efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required
for LED fixtures as per BIS shall be submitted. Shape size
and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal
Supplying and fixing suitable size GI box with modular
plate and cover in front on surface or in recess,
including providing and fixing 2 nos. 3 pin 5/6 A
modular socket outlet and 2 nos. 5/6 A modular
switch, connections etc. as required. (For light plugs
to be used in non residential buildings).
Supplying & fixing suitable size GI box with modular
plate and cover in front on surface or in recess
1.57 including providing and fixing 25 A modular socket Each 1 807 807
outlet and 25 A modular SP MCB, "C" curve including
connections, painting etc. as required.
MR L.T. Cable Supply
Supply of following sizes of 1.1kV grade multicore aluminium conductor XLPE
armoured power cable as per IS: 7098 ammended upto date as per the following
MR LT Cable laying
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV
grade of following size direct in ground including excavation and refilling the trench
etc as required, but excluding sand cushioning and protective covering.
10.3.2 Above 35 sq. mm and upto 95 sq. mm Mtr. 120 276 33120
10.3.3 Above 95 sq. mm and upto 185 sq. mm Mtr. 50 298 14900
10.3.3 Above 185 sq. mm and upto 400 sq. mm Mtr. 192.8705 364 70204.862
Supplying and making end termination with brass compression gland and aluminium
11.1 lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor
cable of 1.1 KV grade as required.
MR Domestic Water Meter
Supply, Installation, Testing and Commissioning (SITC) of Water Meter, conforming
to ISO 4064 Class-B, with flanged end connections, dry dial magnetic drive register,
suitable for measurement of water, complete with gaskets, nuts, bolts, jointing
materials and all accessories required for proper installation. The meter shall have a
nominal flow rate (Qn) of 60 m³/hr, maximum flow rate (Qmax) of 120 m³/hr,
transitional flow rate (Qt) of 12 m³/hr, and minimum flow rate (Qmin) of 1.8 m³/hr.
The work shall include testing, calibration (if required), commissioning, and handing
over complete in all respects as per the manufacturer's recommendations and the
approval of the Engineer-in-Charge.
MR Chequred Plate
Digitally signed by AMIT
Providing, fabricating, supplying, and fixing M.S. chequered plate covers over
trenches, pits, tanks, channels, etc., of required sizes and shapes, comprising M.S.
chequered plates of approved thickness fixed to M.S. angle/channel/frame sections,
including cutting, straightening, bending, welding, grinding, drilling, making lifting
handles, surface preparation, one coat of red oxide zinc chromate primer and two
coats of synthetic enamel paint of approved shade, complete in all respects as per
directions of the Engineer-in-Charge. The item includes all materials, labour, tools &
plants, consumables, loading, unloading, transportation, erection, and all incidental
works required for completion.
5 mm thick Sqm 10 5100 51000
MR Water Level Indicator
Providing, supplying, installing, testing and commissioning of water level indication
and alarm system for 5 Nos. (04 Nos. Over head & 01 Nos. Under Ground) water
storage tanks, comprising low, medium and high level sensing arrangement in each
tank, electronic water level controller/indicator panel, audio alarm (buzzer) for full Set 1 110000 110000
tank indication, sensors/electrodes, control wiring, power supply, interconnections,
mounting accessories, conduits, junction boxes, termination, testing, calibration and
commissioning, complete in all respects as required and as directed by the Engineer-in-
Charge. The item shall include all materials, labour, tools, tackles, transportation and
accessories necessary for satisfactory operation of the system.
MR Exhaust Fan
Providing, supplying, installing, testing and commissioning (SITC) of Axial Flow Fan
suitable for ventilation/exhaust application having minimum air delivery capacity of
3500 CFM (approximately 5950 CMH) at 15–25 mm WG static pressure, complete
with dynamically balanced cast aluminium/FRP aerofoil impeller, heavy-duty powder-
coated steel casing, TEFC squirrel cage induction motor of suitable rating (1.0 HP to
1.5 HP), IP55 protection, Class-F insulation, operating on 220V/415V, 50 Hz AC supply,
complete with suction and discharge side safety guards, mounting frame/brackets,
anti-vibration pads, foundation bolts, control switch, interconnecting wiring from
nearest power source, earthing, alignment, testing and commissioning. The item shall
include all materials, accessories, labour, tools and tackles, transportation, installation
and all incidental works required for satisfactory operation, complete in all respects as
per manufacturer's specifications and directions of the Engineer-in-Charge.
Total (DSR+NDSR) 16697890.00
Buyback (Fire Fighting Pumps, Old pipe & Panel) 210000.0
G-total 16487890.0
Digitally signed by AMIT
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
NIT IOC JMC.pdf
Tender Document
BOQ IOC JMC.pdf
Tender Document
SCC IOC JMC.pdf
Tender Document
GCC 2026.pdf
Tender Document
Instruction to Bidder for online Bid Submission.pdf
Tender Document
FORMS.pdf
Tender Document
Standard List of make.pdf
Tender Document
Download all tender documents and submit your bid