Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹89.3 LAccepted-AOC BLOCK NO 403 BENGALI COLONY RANJHI JABALPUR | JABALPUR | JABALPUR | MADHYA PRADESH | 482005 | L1 | Accepted-AOC BEING LOWEST REASONABLE BIDDER | |
| 2 | L2₹97.7 L+₹5.4 L (5.90%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹99.9 L+₹7.7 L (8.29%)Rejected-Finance DIWANBADA MANEGAON POST OFFICE KHAMARIA JABALPUR 482005 M P | JABALPUR | MADHYA PRADESH | 482005 | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹1.0 Cr
EMD Value
₹1.8 L
Closing Date
20 Feb 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE JABALPUR
HQ CWE JABALPUR OPPOSITE SUPPLY DEPOT SADAR 482001
CERTAIN SANCTIONED WORK UNDER GE EAST JABALPUR
2025_MES_693853_1
82695/E8
Open Tender
Civil Works
Item Rate
270 days
JABALPUR
AS PER NIT
7 documents required · 7 mandatory
₹1,000
Yes
GE (EAST) JABALPUR
₹1.8 L
Yes
23 May 2025
18 Jan 2025
22 Feb 2025
18 Jan 2025
20 Feb 2025
8 Feb 2025
18 Jan 2025 - 7 Feb 2025
Amount
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick(AZ-150) of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick(AZ-150) of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed
S&F roof trusses (framed), trussed, purlins, crane gantries, rails and fastening and heavy bracket framing (beam, tee, angle channel or flat sections) including distance pieces, cleats etc conforming to Fe-410W(Gde E-250) Quality 'A' complete all as specified and directed.
S&F mild steel flat iron conforming to Fe-410W(Gde E-250) Quality 'A' as in wind tie for roof sheet including securing bolts complete all as specified and directed.
M&L framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe-290.Gde-E-165 complete all as specified and directed.
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L Non - skid Ceramic white tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including provision of 15 mm thick screed bed in CM 1:6 complete all as specified and directed.
M&L Glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick, set and jointed in neat cement slurry and pointed in white or colour cement to match with the shade of tiles including provision of 10 mm thick rendering in CM(1:4) complete all as specified and directed.
M&L for 18-20mm thick Granite (of any type) work (table rubbed and polished) in cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including moulding and rounding complete all as specified and directed.
Dismantling of brick work or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar ficings, dressed stone work and pre-cast concrete articles complete all as specified and directed.
Taking down cement plaster etc on brick walls/ concrete (ceiling) surfaces of any descriptions including racking out joints, hacking for keys, scrubbing down with water and disposal of unserviceable materials to out side of MD land complete all as specified & directed.
M&L for brick work with fly ash bricks, straight or curved on plan exc. 6m mean radius and setting in cement mortar 1:6 etc. complete all as specified as directed.
M&L Brickwork with sub- class ‘B’ fly ash bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortar 1:6 etc. complete all as specified as directed.
M&L 15mm thick rendering on fair faces of brick surfaces in CM (1:4), first coat 10 mm thick plaster in CM 1:4 and second coat 5 mm thick in CM 1:4 with using water proofing liquid finished surfaces even and smooth without using extra cement complete all as specified and directed. (Note : Liquid water proofing compound shall be measured and paid for separately as "Supply only")
Supply only liquid water proofing compound ISI Marked, of make as approved by GE complete all as specified & directed.
Taking up or down 15mm bore steel water tubing & connections, including cleaning for refixing or removal from site complete all as specified and directed.
Taking up or down 20 mm bore steel water tubing & connections, including cleaning for refixing or removal from site complete all as specified and directed.
S&F 15mm bore tube, medium grade, galvanised, with all fitting & fixed complete to walls or ceiling & laid in floors complete all as specified and directed.
S&F 20 mm bore tube, medium grade, galvanised, with all fitting & fixed complete to walls or ceiling & laid in floors complete all as specified and directed.
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing etc., and making good, cutting not exc 10 cm in girth in brick wall complete all as specified and directed.
Dismantling water tanks of 1000 ltrs capacity and removing from site and S&F 2000 ltrs capacity rotational moulded polyethylene water storage tanks, double layered, ISI marked, (Cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I (2009)complete all as specified and directed.
S&F 20mm bore ball brass valve, high pressure with polyethylene float & fly nut complete, screwed for iron pipe or brass ferrule complete all as specified and directed.
S&F, in repair, 20mm bore Gun metal gate valve with iron wheel head screwed both end for iron pipe complete all as specified and directed.
S&F PVC floor trap 75 mm dia with CP gratings complete all as specified and directed.
S&F PVC nahani trap 110 mm dia with CP gratings complete all as specified and directed.
S&F, in repair, vitreous china, white, counter oval shape wash hand basin of size 630x450mm including brackets complete all as specified and directed.
S&F waste coupling brass CP for glazed ware sink, WHB etc with long screwed shanks and fly nuts complete suitable for 32mm dia.etc. complete all as specified and directed.
S&F, in repair, 15mm bore fancy type chromium plated bib taps with crutch or butterfly handle screwed down for iron pipes complete all as specified and directed.
S&F, in repair, angle stop valves 15mm bore, fancy type chromium plated cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified
S&F, in repair, 15mm bore PVC connection with PTMT nuts of length 450mm complete all as specified and directed.
Supply and fix 15 mm bore CP pillar taps, fancy type, cast copper alloy with capstan heads screwed down high pressure with or without lettered `Hot' or `Cold' with long screwed shanks and fly-nuts, screwed for iron pipe complete all as specified and as directed.
S&F, in repair, brass chromium plated shower rose 125mm size complete all as specified and directed.
M&L preparing new steel surfaces and applying two coat of syntheitc enameled paint over a red oxide primer exc 10 cm in width or girth complete all as specified and directed.
M&L for prepraring newly plastered surfaces of wall and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. complete all as specified and as directed.
S & F, in repair, PVC waste pipe 32 /40 mm dia x 600 mm long complete all as specified and as directed
M&L for 15 mm thick rendering in cement mortar (1:6) on brick work or concrete surfaces finished even and smooth without using extra cement complete all specified and directed.
M&L rendering on concrete/brick surfaces 15mm thick in CM (1:4), surface finished even and smooth without using extra cement complete all as specified and as directed
M&L 5mm thick rendering in Cement Mortar( 1:3) on Concrete Surfaces, ceiling etc finished surface Even and Smooth, without using extra cement
M&L for preparation of newly plastered surfacces and applying three coat of white wash as in ceilling complete all as specified and as directed.
M&L for Preparing Newly Plastered Surfaces of internal wall and applying two Coats of oil emulsion distemper over a coat of alkali resistant primer complete all as specified and as directed.
M&L for Preparing Newly Plastered Surfaces of external Walls and applying Two Coats of Cement Base Paint over a coat of appropriate primer complete all as as specified and as directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets including E- Grid frame work complete all as specified and directed.
S&F suspended false ceiling system using Chicago metallic (E-grid) exposed suspended system, grid size 600x600mm comprising of GI powder coated main runner of dimension 39mmx24mm x 0.8mm thick (Thickness comprising of GI/0.5mm+PPPCGS/0.3mm & weight of runner 1.35 Kg for 3600mm length), cross Tee of dimension 29mm x 24mm x 0.7mm thick (Thickness comprising of GI/0.5mm+PPPCGS/0.3mm & weight of Tee 0.195Kg for 600mm length) and wall angle of dimension 22.2mm x 22.2mm x 0.65mm thick (Thickness comprising of GI/0.35mm + PPPCGS/0.30mm & weight of angle 0.700 Kg for 3050mm length) with and including 6mm thick HSPC (High Pressure Steam Cured) pre-primed, self embossed, textured designer board, water, termite & fire resistant for insulation and acoustic purpose to be placed in the grid system duly suspended with 4mm dia GI bar hangers fixed with steel dash through fasteners from purlins with butterfly clips (wt 0.007 Kg/clip), hold down clips (wt - 0.0035 Kg/clip), with provn of light fixture complete all as per Manufacturer's instructions and as directed.
Fixing only 6mm thick in ceiling flat or sloping Non asbestos cement building boards fixed or laid/inserted to timber/GI/Aluminium frame work fixed with screw as per manufacturer's instructions complete all as specified and directed. (Note : Old serviceable material retrieved against Srl item No. 45 of this BOQ shall be re-used.)
Dismantling asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed.
Dismantling timber fillets,posts rafter purlin under 40 sqcm in sectional area, framed work, complete all as specified and as directed.
Dismantling timber in scantling, 40Sqcm and over in sectional area, framed work, in any position complete all as specified and directed.
S&F hand rails, half rounded or other stock section or core for wooden hand rail straight portion, drilled and counter sunk for balusters, nosing to steps including embeding in concrete and screwing etc wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc; flat iron fillets (for securing wire mesh etc,) including all necessary drilling bolting or riveting, etc and similar work conforming to Fe-290 (Gde E-165) complete all as specified and directed.
Fixing only wind ties complete all as specified and as directed. (Note : Old serviceable material retrieved against dismantling shall be re-used.)
S&F mild steel screw bolt (machine made) with square or hexagonal head at one end, screwed other, fitted with washer and one hexagonal or square n exc 5cm, long and 5 to 10mm dia complete all as specified and directed.
S&F rolled sections conforming to Fe-410W(Gde E-250) Quality 'A', as in main and cross beams, hip and jack rafters; purlins where connected to a common rafters, fixed with angle cleats or other connecting plates, complete all as specified and as directed.
M&L for PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) in lintels upto 1.5 clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers ,apex stones, bed plates, water troughs and the like including use of formwork (straight or curved) ,including weathering, slightly rounded or chamfered angles and throating, complete all as specified and as directed (Note :-reinforcement where provided shall be measured and paid for separately)
M&L for Non Skid ceramic tiles 7 to 8 mm thick ( square / rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles ( in patches to match the existing colour /shed) over and including screed bed 15mm thick rendering in CM (1:6) complete all as specified and as directed
M&L vitrified ceramic tiles 10 mm thick, in LIGHT/DARK SHADE, (Square/rectangular) polished, area of Each tile not exceeding 0.36 Sqm, in floors etc. set & jointed in neat cement slurry and pointed in coloured cement to match with the shade of coloured tiles, laid over and including 15 mm thick screed bed or bedding layer in CM (1:6) complete all as specfied and directed.
M&L for vitrified ceramic tiles 10mm thick LIGHT/DARK SHADE(square/rectangular) polished area of Each tiles not exceeding 0.36 Sqm as in vertical surfaces such as dados/skirting etc, set and jointed in neat cement slury and in coloured cement to match with the shade of coloured tile laid over and including 10mm thick backing coat in CM(1:4) complete all as specfied and directed.
Demolition of cement concrete of any description (unreinforced) in ground floors and paving not exceeding 15 cm in thickness (below or above ground level) including removal of debris to out side MD land complete all as specified & directed.
M&L for 25MM thick cement concrete(1:2:4),Type B-1 (using 20mm graded stone aggregate ) as in base complete all as specified and directed
M&L 75mm thick PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in sub base complete all as specified and directed
Material and labour 20-25 mm thick machine cut kota stone flooring laid over cement screed base and jointed with neat cement slurry mixed with pigment to match with the shade of the slab laid over and including 20 mm thick bedding layer in cement mortar (1:6) including rubbing and polishing complete all as specified and directed.
M&L 18 to 20 mm thick machine cut kota stone as in vertical surfaces risers of steps , skirting, dado and pillars etc, set and jointed in neat cement slurry and pointed with grey cement mixed with pigment to match with the colour of stone slab, laid over and including 10 mm thick rendering in cement mortar(1:4) including rubbing and mirror polishing complete all as specified and directed.
M&L 75 mm thick PCC (1:3:6) type C-2 (using 40mm graded crushed stone aggregate) as in plinth protection finished even & fair without using extra cement, laid in bays with construction joint, 6mm thick joints should be filled with bitumen mastic filling comprising of one part of heated bitumen 80/100 gde and three part of sand ( all by weight) complete all as specified and directed.
Taking down Chowkhats or frame with shutter (without taking off shutter from the frame) area n.exc 1.50 sqm each and removal complete all as specified & directed.
Taking down Chowkhats or frame with shutter (without taking off shutter from the frame) area exc 1.50 sqm but n.exc 4 sqm each and removal complete all as specified & directed.
Taking down Shutters of any description n.exc 1 Sqm each and removal complete all as specified & directed.
Taking down Shutters of any description exc 1 Sqm but n exc 2.0 Sqm each and removal complete all as specified & directed.
supplied and fixed Pressed steel frames , size 125x 60 mm, for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as specified & directed.
M&L for IInd class (Indian Sal, Bijasal, Hollock or Benteak) hardwood plain, solid, straight chowkhats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue, pinned at joints complete all as specified & directed.
S&F, Powder coated(Minimum thickness of powder coating 50 micron) Aluminium anodised sections for doors/windows/ventilators with one or more rebates including joining cleat for fixing etc complete with frames, shutters and grills of size as directed by Engineer-in-charge including handles, tower bolts, grills, etc complete all as specified and directed. Note:- Floor door spring, sheet glass, wire cloth, lock, etc shall be measured and paid for separately.
M&L PCC 1:3:6 type C1 using 20mm graded stone aggregate as in filling of pressed steel door frame complete all as specified and directed.
M&L for factory made 35mm thick second class (Indian Sal, Bijasal, Hollock or Benteak) hardwood plain, framed, panelled shutter (two or three panels) with lock rail and panel of 9mm thick B.W.P commercial ply or 12mm thick veneered particle board with commercial veneering on both faces; size of rail and stiles as per IS: 1003 (Part-I), kiln seasoned complete all as specified & directed.
M&L for factory made second class (Indian Sal, Bijasal, Hollock or Benteak) hardwood glazed and skeleton shutters 35mm thick, open rebated and prepared to receive glass, gauze, etc divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc sizes of members of shutters as specified in SSR Part-I, Section 8, clause 8.24 (a) and fitted to chowkats complete all as specified & directed. Notes:- (i) glazing will be measured and paid for separately. (ii) Butt hinge will be measured and paid for separately .
S&F steel windows with side hung shutter including projecting type hinges with steel handle and steel peg stay, complete with glazing bars, dovetailed or welded, complete all as specified and directed.
S&F steel windows with side hung shutter including projecting type hinges with steel handle and steel peg stay, complete without glazing bars, dovetailed or welded, complete all as specified and directed.
S&F steel windows or ventilators, fixed type, with glazing bars, complete all as specified and directed.
S&F solid PVC door frame of size 50mm x 47 mm made out of 5 mm plain colour PVC sheet, reinforced with MS square tube, complete as all as specified and directed.
S&F factory made solid panel PVC door shutter 30mm thick (Style) consisting of frame made out of MS tubes for top, bottom and side rails, MS frame shall be covered with heat molded plain colour PVC “C” channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail lock rail & bottom rail on either side and as gap insert for top rail and bottom rail paneling of plain colour PVC sheet to be fixed in the MS frame welded /sealed to the stiles and rails with suitable PVC sheet beading and jointed together with solvent cement and fixing in the frame at site complete all as specified and directed.
S&F, aluminium anodised, barrel tower bolts of extruded section with length of bolt 150 mm and fixed complete all as specified and directed
S&F, aluminium alloy, anodised, sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy with length of bolt 300 mm and fixed complete all as specified and directed.
S&F, 100mm butt hinges extruded aluminium alloy with galvanised mild steel hinge pin,Type-B-21 complete all as specified and directed.
S&F continuous (piano) hinges,mild steel bright finish or electrogalvanised,width of flaps 30 mm complete all as specified and directed.
S&F extruded aluminium alloy handles, fabricated type, anodised, of size 150 mm complete all as specified and directed.
S&F extruded aluminium alloy handles, fabricated type, anodised of size 125 mm complete all as specified and directed.
S&F 150mm long floor door stopper of aluminium alloy body and tongue with hard drawn steel spring complete all as specified and directed.
S&F 300mm long mild steel ordinary rat tail rod pattern springs,including roller and roller plate complete all as specified and directed.
S&F 125mm hasp and staples,aluminium anodized including bolt to hinges plate and fixed with screws complete all as specified and directed
S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staple/ wooden beads complete all as specified and directed.
M&L for 9 mm thick prelaminated particle board, interior grade,prelaminated both sides with decorative choice laminations fixed with screw to timber/steel frame work as in repair complete all as specified and directed
M&L for 19 mm thick prelaminated particle board, interior grade,prelaminated both sides with decorative choice laminations fixed with screw to timber/steel frame work as in repair complete all as specified and directed
S&F 3mm thick Sheet glass,ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and directed
S&F 4mm thick figured glass, pin headed type and glazing with oil putty in square n. exc 0.5 Sqm each pane complete all as specified and directed
Hacking out old broken glass (any thickness, size, quality or description) from metal frames including punching or drilling out old glazing pins/spring clips and providing and fixing new one complete all as specified and directed
S&F 5.5mm thick Sheet glass,ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and directed
S&F 5.5mm thick Sheet glass,ordinary quality and glazing with oil putty in square exc 0.5 sq. m in each pane complete all as specified
S&F framed work conforming to Fe-290 ( Gde E-165), as in doors or gates of angle or other section with gusset plates ,rails,braces etc complete drilled for fixing of steel gate sheeting or other covering,doors ,etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering ,runing rails and guides ) and hanging also fastning and fixing complete all as specified and directed.
M&L for Cutting holes in brick walls exc half brick but n exc one brick in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar (1:3) or cement concrete (1:2:4) Type B-1 using 20mm graded crushed stone aggregate, complete all as specified and directed. (Note : This item will be considered for fixing the holdfast in the new location.)
S&F Tubes medium grade, 25mm bore galvanised with all fittings and fixed complete to wall and ceiling or laid in floors Complete all as specified and directed.
Re-fixing Tubes medium grade, 15mm bore galvanised with all fittings and fixed complete to wall (Conceiled)and ceiling or laid in floors Complete all as specified and directed.
Re-fixing Tubes medium grade, 20mm bore galvanised with all fittings and fixed complete to wall and ceiling or laid in floors complete all as specified and directed. (Note : Old serviceable GI tube retrieved against dismantling shall be re-used.)
Re-fixing Tubes medium grade, 25mm bore galvanised with all fittings and fixed complete to wall and ceiling or laid in floors complete all as specified and directed. (Note : Old serviceable GI tube retrieved against dismantling shall be re-used.)
Cutting chases in brick walls, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing etc., and making good, cutting not exc 10 cm girth complete all as specified and directed.
S& F, in repair, Stop valve / Angle valve, concealed type, cast copper alloy chromium plated screwed down high pressure with capstan heads screwed both ends for iron pipe or for union and fixed 15mm bore complete all as specified and directed.
S& F, in repair, 15 mm bore bib tap cast copper alloy, chromium plated, long body fancy type with capstan headed, screwed down, screwed for iron pipe complete all as specified and directed.
S&F, in repair, 15mm chromium plated brass WHB mixer fancy type swan neck long nose- screwed down high pressure with or without lettered hot and cold and flynuts 15 mm dia complete all as specified and directed.
S&F, in repair, 15mm dia pillar tap cast copper alloy chromium plated capstan head screwed down high pressure with or without lettered hot or cold with long screw shank and fly nutt screw for iron pipe, complete all as specified and directed.
S&F,in repair,Stainless steel sink with draining board, made out of 1.00mm thick sheet for kitchen or laboratory with plug, washers waste pipe, cast iron cantilever brackets, connecting union overall Size 915mmx460mm with bowl size 410mm x330mm x 160mm complete all as specified and directed.
Soap dish, stainless steel approx size 160mm x 160mm x 90mm complete all as specified and directed.
M&L for 32 mm bore Low Density Polyethylene pipes (LDPE) with fittings of pressure rating 6 Kgsf / Sqcm fixed to walls or in floors etc complete all as specified and directed.
S&F in repair PVC connection 600 mm long, 15mm size with PTMT nuts complete all as specified
S&F in repairs 10 ltr PVC valve less symphonic action type flushing cistern, low level white with inlet ball valve float and handle with flush pipe complete all as spfd
S&F in repairs grating doom 125mm dia PTMT with waste hole (Min weight 40 grms)
S & F in repairs Towel rail 600 mm long and 20 mm dia brass chromium plated D type fixed with screws and wooden or plastic cleats complete all as specified and directed.
M&L for 100mm dia cast iron floor trap plain with grating including jointing and fixed with cement concrete(1:2:4) type B-1 using 20mm graded crushed stone aggregate complete all as specified and directed.
M&L for 75mm dia PTMT multi floor trap plain with grating including jointing with solvent cement complete all as specified and directed.
Taking down eaves gutters and rainwater pipes (any size or pattern ),including all fittings,heads,shoes,bends,swan necks etc.including cleaning or refixing or removal from site complete all as specified and directed.
S&F in repair vitreous China squatting pan of pattern Orissa Pan , size 580 x440 mm white with integral foot rests any pattern (excluding flushing cistern and flush pipe) complete including provn of Plain Cement Concrete(PCC) bedding connection to flush pipe , trap etc & making good complete all as specified and directed.
S&F, in repair, PTMT bottle trap ( with internal partition) 32mm bore having minimum water seal of 25mm complete all as specified and directed. (Minimum weight 32mm-260 gm)
S& F, in repair, Vitreous China wash hand basin, white, flat back, size 550mm x 400mm including brass coupling, mild steel brackets fixed to wall, with pedestal complete all as specified and directed.
S& F, in repair, Vitreous China wash hand basin, white, flat back, size 550mm x 400mm including brass coupling, mild steel brackets fixed to wall, complete all as specified and directed.
S&F, in repair, vitreous China bowl urinal flat back of size 465x355x265mm white (minimum) with grating and union for discharge pipe (excluding flushing cistern flush pipe and waste pipe) including connections to flushing pipe and out going pipes etc complete all as specified and directed
S & F, in repair, Vitreous china urinal half stall type ,white including connection to flushing pipe and outgoing pipe complete all as specified and directed.
S&F CP waste fittings brass chromium plated for WHB/sink 32mm dia with long screws sinks and fly nuts , flanged end, bedded in red lead cement and other fixed complete all as specified and directed.
S&F CP waste fittings brass chromium plated for sink 40mm dia with long screws sinks and fly nuts , flanged end bedded in red lead cement and other fixed complete all as specified and directed.
M&L for Preparation of newly wooden surface of any description over 10 cm width or grith and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M&L 2mm thick wall care putty on wall complete all as specified and directed.
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces & also providing and applying plaster of paris putty of 1 mm thickness over plastered surface to prepare the surface even and smooth complete all as specified and directed.
Stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed.
S & F in repair Gun-metal, globe or gate valves 25mm, with iron wheel head, screwed both ends for iron pipe and fixed,complete all as specified and directed.
Dismantling water tank of any description, of capacity exc. 1000 litres but not exc. 2000 litres, removing from the site complete all as specified and as directed.
S&F 1000 ltr capacity Rotational moulded polyethylene water storage tank, double layered, ISI Marked, (cylindrical vertical closed top) hoisted and fixed in positions all as specified in SSR Part-I(2009),including 25 mm dia ball valves high pressure of PTMT with epoxy coated aluminium rod &high density plastic ball screwed for iron pipe and fixed complete all as specified and directed.
M&L factory made 80 mm thick rubber moulded glossy finish machine pressed precast concrete interlocking paver block with grey cement and pigment any shape and size conforming to IS 15658-2006 of M-40 grade, laid over and including 50mm thick sand cushioning/M-sand complete all as specified and directed.
M&L kerb stone of machine pressed coloured precast cement concrete (1:2:4) type B1 using 20mm graded stone aggregate, block of size 30cmX30cmX15cm finished at top bullnosed shape and finished surface even and smooth using coloured pigment and jointed in CM(1:6) struck finished, including applying two coats of paints in zebra pattern complete all as specified and directed.
Roughening surfaces of old concrete floor/terrace by picking including taking down existing deteriorated / decayed tarfelt, PCC tiles or any type of treatment including loose surface, scrapping with scrapper, chiseling, scraping of surface with wire brush or any other method, sweeping clean & washing down with water to remove dust etc. and removing the scrapped materials/ debris to a distance not exc. 50 m, complete all as specified and directed.
M&L for wire brushing and cleaning top surface of tiles,lime terracing or cement concrete,including flashing and junction of parapet,etc,and surface painting with a layer of blown bitumen of any penetration applied hot @1.70 kg per sqm.blinded with grit or pea size gravel @ 0.006 cu.m per sqm and lightly tampered (area of flashing etc.shall be added to the roof area, complete all as specified and directed.
M&L for 10 mm thick screed bed or bedding layer in CM 1:3 mixed with water proofing compound @ 3 % by weight of cement on concrete roof surface finished fair and even to maintain the proper slope of roof surface etc complete all as specified and directed.
Cleaning of plastered roof surfaces and applying a coat of bitumen primer @ 0.30 kg/Sqm on top of dry surface of finished cement mortar plaster complete all as specified and directed.
One coat of hot blown bitumen of grade 85/25 @ 1.2kg /sqm shall be applied over primed surfaces complete all as specified and directed.
One layer of APP based polymeric water proofing membrane of weight not less than 3 kg/Sqm consisting of 3mm thick reinforced with polyster non woven fabric shall be unrolled, surfaces with end lap of 100 mm and the side lap of 150mm, the over lap shall be sealed by flame,complete all as specified and directed.
Applying two coats of aluminum paint on top of membrane @ 0.10Kg/Sqm in each coat complete all as specified and directed.
M & L Bitumastic gola, with 80/25 bitumen and coarse sand mixture, 1:3 by weight, 8cmx8cm at the junction of roofing to vertical surfaces complete all as specified and directed.
Supply installation testing and commissioning CPRI approved factory fabricated, out door type,LT feeder pillar box of size not less then 2m width x1 m height x 0.5m depth,made out of 3.15 mm thick CRCA sheet with projected globe roof for rain water protection dust and vermin proof,double door with both side opening including Neoprene rubber gasket,suitable for 440 volt 3 phase 4 wire system ,including danger plate,earthing strip point and ventilation Louvers at rear side,bottom detachable gland plate complete with suitable size Zinc, chromium plated nuts,bolts and washers,etc. and embedded with 50x50x6mm Mild steel angle Iron frame and 750 mm above the normal ground level complete with internal connection with suitable size of cable lugs and cable glands, PCC foundation in cement concrete (1:3:6), Type C-1 (using 20mm graded crushed stone aggregate) and testing after installation complete all as specified and comprising of the followings:- (a) Aluminium bus bar 650 Amps- 01 set (b) MCCB 400 Amps, 4 pole 36 KA, adjustable thermal & fixed magnetic setting (incoming) - 01 No (c) MCCB 250 Amps, 4 pole 16 KA, adjustable thermal & fixed magnetic setting (incoming) - 01 No
(d) MCCB 160 Amps, 4 pole 16 KA, adjustable thermal & fixed magnetic setting (incoming) - 01 No (e) 3 Phase LED digital ammeter class 1.0 (f) 3 phase LED Digital voltmeter class 1.0 (g) Indicator lamp - 03 Nos
Surface excavation n exc 30 cm deep and averaging 15 cm deep and getting out soft/loose soil complete all as specified and directed
Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, for laying of pipe, cable etc or n. exc.10 Sqm on plan and n. exc. 1.5m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in any type of soil complete all as specified and directed.
Returning, filling in excavated approved soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm each complete all as specified and directed.
Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Removing excavated material exc. 250 m but n exc. 500 m and depositing where directed complete all as specified and directed.
Supply unwashed Sand cushioning to under ground cable provided with a layer of 8 cm deep before laying and 15 cm covering above the top edge of cable after laying complete all as specified and directed. Note : Measurement shall be done after punning down of sand.
Supply and laying unreinforced precast concrete cable covers, Class LV, flat, type-I, size 250 mm x 150 mm x 40 mm, complete all as specified and as directed.
Supply and laying or fixing or passing in trenches/ on pole/ through pipes, 1100 volts grade XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with stranded aluminium conductor of cross section area 120 sqmm, 3.5 core including jointing materials such as cable glands & lugs etc Complete all as directed.
Supply and laying or fixing or passing in trenches/ on pole/ through pipes, 1100 volts grade XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with stranded aluminium conductor of cross section area 95 sqmm,3.5 core including jointing materials such as cable glands & lugs etc Complete all as directed.
M&L cement concrete (1:4:8) type D-2 (using 40 mm graded stone aggregate) as mass concrete complete all as specified and directed.
M&L for cement concrete (1:3:6) type C-2 using 40 mm graded stone aggregate as in mass concrete and foundation filling complete all as specified and directed.
M&L for preparation of new or previously untreated surfaces of steel of any description, not exc 10cm in width or girth when unconnected with other painting and apply two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for broken stone or boulder hard core of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for 75 mm thcik PCC 1:4:8 type D2 using 40mm graded aggregate as in sub base complete all as specified and directed.
Supply and laying or fixing or passing in trenches/ on pole/ through pipes, 1100 volts grade XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with stranded aluminium conductor of cross section area 25 sqmm, 4 core including jointing materials such as cable glands & lugs etc complete all as specified and directed.
Supply and laying or fixing or passing in trenches/ on pole/ through pipes, 1100 volts grade XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with stranded aluminium conductor of cross section area 35 sqmm, 3.5 core including jointing materials such as cable glands & lugs etc complete all as specified and directed.
Supply and laying or fixing or passing in trenches/ on pole/ through pipes, 1100 volts grade XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with stranded aluminium conductor of cross section area 70 sqmm,3.5 core including jointing materials such as cable glands & lugs etc complete all as specified and directed.
S & F On load manual change over switch 415 Volt in sheet metal enclosure 4 pole of capacity 400 amps, complete all as specified & directed.
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6.0mm thick directly burried in the ground (earth pit not less than 2.25M deep below ground level) with top edge of earth plate not less than 1.50M deep below normal ground level, connected to galvanised iron strip 32x6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel, 40mm bore GI pipe light grade including necessary fittings for protection of earthing strip, watering pipe 20mm bore GI medium grade, concrete chamber in PCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate, coping shall be in PCC 1:2:4 type B-1using 20 mm graded crushed stone aggregate and internal surfaces of concrete chamber shall be given 12mm thick plaster in CM (1:4), funnel with wire gauge of 22 gauge 8 mesh per linear including 50mm thick cover of RCC (1:2:4) type B-1 using 20mm grade stone aggregate reinforced with 8mm MS TMT bar @ 75 mm C/C both ways, char coal dust and common salt all as shown in electrical plate No. 3 of SSR Part-I (2009) including all necessary excavation & earth work and removal of surplus soil to a distance n. exc 50M and providing connection points with MS/ GI bolts & washers as required and connection from earth test point to earth electrode with same GI earth strip alongwith protection pipe and testing on completion complete all as specified and directed. Note:- GI strip and protection pipe from earth electrode to test point, max upto 7.50M, shall be deemed to be included in the unit rate as quoted by the contractor against this item.
S & F Supply, installation commissioning and testing of silent Diesel engine driven fenerating set of 415 volts, 3 phase, 4 wire engine as per CPEB IV norms IS : 10001/10002 and Alteration 13364 with AMF panel complete with relay panel and switch gears for automatic starting on main failure, contral panel having mater and sound proof canopy as per CPCB IV norms and foundation (GI sheet shed complete etc of capacity of 125 KVA complete in all respect with and including accessories and components as specified and directed by Engg-in -Charge. (a) Engine (i) 4 cylinder, in line, 4 stroke, radiator cooled engine (ii) Robust and efficient air handling system with dry type & replaceable paper element air cleaner with restriction indicator and optimized turbo charger for increased altitude capabilities. (iii) optimized fuel consumption with common rail electronic injection (iv) Spin on single fuel filter with water separator (v) Cooling system is designed and tested for 50 degree celcius ambient conditions (vi) Full flow spin on lube oil fiter & first fill of lube oil and coolant (vii) Electrical starter motor with soft start engagement feature (viii) Battery charging alternator (ix) 2 x 12 V DC battery
(b) Alternator: (i) STAMFORD 52 L 1D and 53 L 1D alternator frames (ii) Brushesless type, screen protected, Revolving Field, Self excited alternator conforming to IS/IES 60034-1 (iii) Better motor starting capability, best in class efficiency (iv) Compact design with sealed bearings for longer life and lesser maintenance (v) Impregnation on all wound components for better mechanical strength (c) Control Panel : Control Pannel is powder coated for weather proof and long lasting finish. The Control Panel consists of the following parts :- (i) PS0602 controller (ii) Bus bars with suitable capacity with incoming /outgoing terminals (iii) Indicator lamps for load ON and 'set Running' instrument fuses duly wired and ferruled (iv) MCCB of suitable rating with short circuit protections (v) AC/DC sepration inside contral panel for safety (d) Silencer: (i) Hospital Grade silencer inside canopy with rain cap suitably optimised to meet stringent noise limit (ii) Silencer specifically tuned to EATS
(e) Mounting arrangement: (i) Engine and alternator are mounted on a common MS fabricated base frame with AVM pads (ii) Skid mounted radiator (iii) Base frame with integral fuel tank and DEF tank is provided with drain plug, air vent, inlet and connection and provision for cleaning (f) Acoustic Enclosure: (i) Specially designed to meet stringent MOEF/CPCB norms of 75 dBA @ 1 mtr at 75 % load under free field conditions (ii) The acoustic enclosure is made of CRCA sheets in Munsell green shade and a structural (sheet metal base frame painted in black (iii) 11 tank pre-treatment process and UV resistant powder coating of all parts to withstand extreme environment (iv) High quality noise absorbent and fire retardant grade acoustic insulation material (Rockwool) conforming to IS 8183 (v) Top lifting for easy handling at customer site (vi) External fuel & DEF filling provision (g) Remote monitoring system (i) Compact & robust device (ii) Real time DG status & monitoring (iii) 4 G compatible
(iv) Compatible for 12/24 V DC (v) Reports and Notification- Alert & warning (vi) ISolated RS 485 interface (vii) Device location using triangulation (h) Optional (i) Engine: Heated Architecture & HD air cleaner (ii) Alternator : PMG and Space heater (iii) EATS : Heated Architecture (iv) Controller : PCC3.3
Supply, installation commissioning and testing of silent Diesel engine driven generating set of 415 volts, 3 phase, 4 wire engine as per CPCB IV norms IS : 10001/10002 and Alternator as per IS: 13364 with AMF panel complete with relay panel and switch gears for automatic starting on main failure, contral panel having meter and sound proof canopy as per CPCB IV norms and foundation,GI sheet shed complete etc of capacity of 58.5 KVA complete in all respect with and including accessories and components as specified and directed by Engg-in -Charge. (a) Engine (i) 4 cylinder, in line 4 stroke, radiotor cooled engine (ii) Robust and efficient air handling system with dry type & replaceable paper element air cleaner with restriction indicator and optimized turbo charger for increased altitude capabilities. (iii) optimized fuel consumption with common rail electronic injection (iv) Spin on single fuel filter with water separator (v) Cooling system is designed and tested for 50 degree celcius ambient conditions (vi) Full flow spin on lube oil filter & first fill of lube oil and coolant (vii) Electrical starter motor with soft start engagement feature (viii) Battery charging alternator (ix) 2 x 12 V DC battery
(b) Alternator (i) STAMFORD 52 L 1D and 53 L 1D alternator frames (ii) Brushless type, screen protected, Revolving Field, Self excited alternator conforming to IS/IES 60034-1 (iii) Better motor starting capacity best in class effeciency (iv) Compact design with sealed bearings for longer life and lesser maintenance (v) Impregnation on all wound components for better mechanical strength (c) Control Panel : Control Pannel is powder coated for weather proof and long lasting finish. The Control Panel consists of the following parts :- (i) PS0602 controller (ii) Bus bars with suitable capacity with incoming /outgoing terminals (iii) Indicator lamps for load ON and 'set Running' instrument fuses duly wired and ferruled (iv) MCCB of suitable rating with short circuit protections (v) AC/DC separation inside control panel for safety (d) Silencer (i) Hospital Grade silencer inside canopy with rain cap suitably optimised to meet stringent noise limit (ii) Silencer specifically tuned to EATS (e) Mounting arrangement (i) Engine and alternator are mounted on a common MS fabricatged bace frame with AVM pads (ii) Skid mounted radiator (iii) Base frame with integral fuel tank and DEF tank is provided with drain plug, air vent, inlet and connection and provision for cleaning
(f) Acoustic Enclosure (i) Specially designed to meet stringent MOEF/CPCB norms of 75 dBA @ 1 mtr at 75 % load under free field conditions (ii) The acoustic enclosure is made of CRCA sheets in Munsell green shade and a structural sheet metal base frame painted in black (iii) 11 tank pre-treatment process and UV resistant powder coating of all parts to withstand extreme environment (iv) High quality noise absorbent and fire retardant grade acoustic insulation material (Rockwool) conforming to IS 8183 (v) Top lifting for easy handling at customer site (vi) External fuel & DEF filling provision (g) Remote monitoring system (i) Compact & robust device (ii) Real time DG status & monitoring (iii) 4 G compatible (iv) Compatible for 12/24 V DC (v) Reports and Notification- Alert & warning (vi) Isolated RC 485 interface (vii) Device location using triangulation (h) Optional (i) Engine :Heated Architecture & HD air cleaner (ii) Alternator: PMG and Space heater (iii) EATS: Heated Architecture (iv) Controller : PCC3.3
Taking down copper/aluminium point wiring (light,fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendents, regulators, sockets, light fittings etc. removing materials from site complete all as specified and as directed.
Taking down old sub main wiring of any size complete all as specified and directed.
Taking down old unserviceable MCB DBs,complete all as specified and directed.
Material and labour point wiring with 1.5 Sqmm single core PVC insulated FRLS unsheathed multi stranded copper conductor drawn into including PVC casing & caping/fixed on wall/roof/ceiling etc of size not less than 20 mm dia including provision of 1.5 Sqmm single core PVC insulated FRLS unsheathed multi stranded copper conductor as earth wire and cast iron / pressed steel treminal boxes for mounting switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet cover and making good the disturbed surface to match with existing specification complete for the following
One light point controlled by one switch 5/6 Amp.
One 3 pin socket outlet 5 Amps, independent board with cables 1.5 Sqmm size.
One fan point controlled by one switch 5/6 Amp.
One Exhaust fan point controlled by one switch 5/6 Amp.
One 3 pin socket outlet 5 Amps, same board with cables 1.5 Sqmm size.
All as per item ser item no- 167 here in before but one 3 pin socket outlet 5/15 Amps, independent board with cables 4.0 Sqmm size.
S&F in repair for switch piano, flush type single pole, one way 5 amp complete all as specified and as directed.
S&F, in replacement, for switch socket combination 2 in 1, 3 pin, 5 Amp flush type complete all as specified and as directed.
S&F in replacement for switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type universal complete all as specified and as directed.
S&F,in replacement, for ceiling rose three terminals/ PVC/ polycarbonate, isolated body complete all as specified and as directed.
S & F,in replacement, stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc complete all as specified and as directed.
Sub main wiring with Two single core PVC insulated FRLS cable with copper conductor multi-stranded 1100 volts grade 4.00 sqmm in and including non-metallic rigid PVC casing and capping and accessories and fixing arrangements fixed to surface on wall, floor or ceiling etc including 4.00 sqmm PVC insulated FRLS multistranded copper earth continuity conductor and connecting to main earth dolly complete all as specified and directed. Note : One run of earth continuity conductor,one run of PVC casing capping and two run of copper conductor together taken as one length for measuring unit length.
S&F MCB,DB SPN 16 way double door DB with 200 amps rated copper bus bar in SS enclosure double door type complete all as specified and directed. Note : MCB SPN/SP shall be measured and paid under the respective item of this BOQ.
S&F MCB,DB SPN 04 way double door DB with 200 amps rated copper bus bar in SS enclosure double door type. Note : MCB SPN/SP shall be measured and paid under the respective item of this BOQ.
Supply and fix for MCB SPN 230 V, 40-63 Amps with breaking capacity 10KA C curve complete all as specified and as directed by Engr-in-charge.
Supply and fix ,in replacement, for MCB SP 230 V, 6-32 Amps with breaking capacity 10KA C curve complete all as specified and as directed.
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers complete all as specified and as directed.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep, Min air delivery 210 CFM with service value 6.00 BEE, Five star rated with brushless direct current motor (BLDC) complete all as specified and as directed.
Supply and fixing LED lights fitting 4 feet, 1 x 20 W, 220V, AC decorative box type with driver, holder including LED tube light, connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
Supply and fixing ,in replacement, LED bldg street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp, bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection including GI pipe, 25 mm bore, light grade, 0.45 metre long, bent to shape required, as in building security light brackets, fixed on walls with suitable size MS clamps, nuts & bolts complete all as specified and as directed.
Supply & fix Wall mounting fan of size 400mm sweep, 100 W power, Air delivary 100 Cubic Metre per Minute(CMM) complete all as specified and as directed.
M/L for earthing for pole complete with galvanized steel earth plate electrode 600 X 600 X 6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5M below normal ground level connected to GI earth lead wire 4 mm dia as earth lead by means of nuts, bolts, check nuts and washer of GI steel and connecting to testing point including provision of test point and all as shown in electrical plate No. 3 of SSR Pt I (2009). The quoted rate is inclusive of necessary earth work and PCC(1:2:4) chamber in type CI with 8 mm CTD bar reinforcement both ways at 140 mm centre to centre complete all as directed by Engr-in-Charge.
Taking up existing old/unserviceable/ burnt under ground cable from the existing positions/ trenches etc., including testing with the help of megger, disconnecting and removing unserviceable portion of cable complete all as specified and as directed. (Note : Excavation/ Earth work shall be measured and paid for separately under relevent items of this BOQ.)
Supply,laying XLPE insulated, screen, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor of size 6 sqmm 2 core, connecting with proper size Aluminium lugs, glands whereever necessary near LT Panels / Bus bar chamber panel / Street light boxes all as per site requirement , testing complete all as specified and directed.
Supply and fix GI pipe light grade 40mm dia for cable protection complete all as specified and as directed.
Supply & lay XLPE insulated armored and PVC sheathed heavy duty electric cable with aluminum conductor 1100 Volt grade laid in trenches/ passing through pipes /ducts including testing complete of following cross sectional area and size including cable lugs & cable gland.
3.5 Core, 50 Sq. mm cross sectional area
4 Core, 35 Sq. mm cross sectional area
4 Core, 16 Sq. mm cross sectional area
4 Core, 10 Sq. mm cross sectional area
Boring of holes under road, pavement, hard standing manually including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure and filling by PCC (1:2:4) Type B-1 using 20mm graded crushed stone aggregate complete all as specified and as directed.
M&L Plain Cement concrete 1:2:4 type B-2 using 40mm Graded Stone Aggregate as in foundations, filling and mass concrete complete all as specified and as directed.
Supply and fix time switches astro type (Having longitude and latitude of Indian cities in memory) 250 V single phase of 20 Amp rating with contactor fitted inside steel enclosure complete all as specified and as directed.
Supply, Installation, test and Commissioning CPRI APPROVED factory fabricated, out door type, LT FEEDER PILLAR BOX of size not less then 1.5m width X 1.2 m height X 0.6 m depth,made out of 3.15 mm thick CRCA Sheet with projected Globe roof for rain water protection Dust and Vermin Proof , Double door with both side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System, including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embedded with 50X50X6mm Mild Steel Angle Iron Frame and 750 mm above the Normal Ground Level complete with internal connection with suitable size of cable, cable lugs and cable glands PCC Foundation in Cement Concrete (1:3:6) Type C-1 (using 20 mm Graded Stone Aggregate) and Testing after Installation including complete all as specified and comprising of the following :–
(a) Aluminum bus bar 600 Amps - 01 Set
Incomer- MCCB 400A 36 KA, 4 POLE ,adjustable type, Ics=100% Icu - 1 No
Outgoing- MCCB 250 A 36 KA, 3 POLE ,thermal magnetic release, Ics=100% Icu - 2 Nos
MCCB 200 A 36 KA, 3 POLE ,thermal magnetic release, Ics=100% Icu - 2 Nos (01 No Standby)
MCCB 63 A 16 KA,3 POLE ,thermal magnetic release, Ics=100% Icu - 2 Nos
LED TYPE indicator lamp 1 set (set of three for R,Y,B)
Supply, Installation, test and Commissioning CPRI APPROVED factory fabricated, out door type, LT FEEDER PILLAR BOX of size not less then 1.5m width X 1.2 m height X 0.6 m depth,made out of 3.15 mm thick CRCA Sheet with projected Globe roof for rain water protection Dust and Vermin Proof , Double door with both side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System, including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embedded with 50X50X6mm Mild Steel Angle Iron Frame and 750 mm above the Normal Ground Level complete with internal connection with suitable size of cable, cable lugs and cable glands PCC Foundation in Cement Concrete (1:3:6) Type C-1 (using 20 mm Graded Stone Aggregate) and Testing after Installation including complete all as specified and comprising of the following :–
(a) Aluminum bus bar 300 Amps - 01 Set
Incomer-
MCCB 250A 36 KA, 4 POLE ,adjustable type, Ics=100% Icu - 1 No
Outgoing-
MCCB 160 A 36 KA, 4 POLE ,thermal magnetic release, Ics=100% Icu - 2 Nos
MCCB 63 A 16 KA,4 POLE ,thermal magnetic release, Ics=100% Icu - 2 Nos
LED TYPE indicator lamp 1 set (set of three for R,Y,B)
Dismantling carefully the existing unserviceable LT Overhead line ACSR conductor of any size from its position by necessary disconnecting of conductor and removing complete all as directed by Engr-in-Charge.
Dismantling unserviceable insulator of any size and type complete from its position and removing all as directed by Engr-in-Charge.
Dismantling unserviceable stay assembly carefully including stay wire necessary excavation and earth work in any type of soil, demolition of PCC of any type and removing from site all as directed.
Dismantling unserviceable existing cross arms by means made from channels, angles, unserviceable FI clamps, nuts, bolts etc. from OH line and removing complete all as specified and directed
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed
Fabrication and installation of GI pipe bracket made of medium Grade tubing of size 32 mm dia, duly bended by hot forgoing after filling of sand, length 1.20 mtr including pair of MS flat strip clamps 30 mm x 5 mm with GI bolts nuts and washer complete all as specified and directed
Dismantling unserviceable main switch/ kitkat DBs/ MCB including wooden board from existing position and making good disturbed surfaces of wall to match with existing surfaces
S&F Sheet Metal Enclosure for DBs made of sheet steel , powder painted with NEUTRAL 200 Amp, neutral link, IP-43-IK09 protection grade , 415Volts TPN with 4 way Double door complete all as specified and directed
M&L MCCB 125 Amps , 415 Volts, 16 KA ,4 POLE complete all as specified and directed
M&L MCCB 100 Amps , 415 Volts, 16KA ,4 POLE, adjustable type complete all as specified and directed
M&L MCCB TPN 63 Amps , 415 Volts, 16KA ,4 POLE complete all as specified and directed
Steel tubing GI light grade for cable protection passing under road /floor/ Pole or for fixing to poles all as specified and as directed of size 50 mm dia complete all as specified and directed
Schedule of credit amount of Rs 1,93,946.50 to be deducted during AOC
M/s Ram Associates (BID ID -3244598)
C L BHATIA (BID ID -3243795)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .