| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.8 LAccepted-AOC 10 RAJAN KUNJ ROORKEE ROAD MEERUT 250001 | MEERUT | UTTAR PRADESH | 250001 | L1 | Accepted-AOC Found lowest bidder | |
| 2 | L2₹26.7 L+₹3.9 L (16.9%)Rejected-Finance | L2 | Rejected-Finance 2nd lowest | |
| 3 | L3₹29.5 L+₹6.7 L (29.2%)Rejected-Finance | L3 | Rejected-Finance 3rd lowest | |
| 4 | L4₹29.6 L+₹6.7 L (29.3%)Rejected-Finance NOT SPECIFIED | L4 | Rejected-Finance 4th lowest | |
| 5 | L5₹31.5 L+₹8.6 L (37.8%)Rejected-Finance 159 SHIV NAGAR MODIPURAM MEERUT 250 110 UP | MEERUT | MEERUT | UTTAR PRADESH | 250110 | L5 | Rejected-Finance 5th lowest |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
18 Nov 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (North) Meerut Cantt
GE (North) Meerut Cantt
PERIODICAL SERVICES IN ZONE-II AND III AREA UNDER AGE B/R-I OF GE (NORTH) MEERUT CANTT
2023_MES_624197_1
8453/E8
Open Tender
Civil Works
Item Rate
180 days
Meerut
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (North) Meerut Cantt
₹90,000
Yes
8 Jan 2024
19 Oct 2023
20 Nov 2023
19 Oct 2023
18 Nov 2023
4 Nov 2023
Amount
Taking down cement plaster from brick or stone walls incl racking out joints hacking for key, scrubbing down with water etc complete all as specified and directed
M&L for rendering 5mm thick cement plaster with cement mortar(1:4)on concrete surface as in ceiling finished even and smooth without using extra cement complete all as specified and directed
M & L for rendering 15 mm thick using ready mix plaster bags in CM 1:4 on brick / concrete surfaces of external walls finished even and fiar, using water proofing compound @ 3% by weight of cement or as per manufacturer instructions, complete all as specified and directed . Note:- Water proofing compound shall be measured and paid sepratly Note :- Contractor is required to deposit ready mix bags for 100% CA quantity to the Engr-in-Charge within 15 days of acceptance of contract.
M&L for rendering 15mm thick cement plaster with cement mortar(1:6)on other than fair faces of brick work or concrete surfaces and finished even and smooth without using extra cement complete all as specified and directed
Supply only Integral waterproofing compound complete all as specified and directed
M&L for preparation of new surfaces and apply two coat of Oil bound distemper to walls,with JK birla putty complete surfaces on walls complete all as specified and directed
M&L for preparing new Plastered or unplastered surfaces of ceiling and applying two coat of white wash complete all as specified and directed
M & L for preparation of new plastered surface of wall making the surface smooth finishing walls and applying Acrylic Smooth exterior paint of required shade (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)using roller for painting complete all as specified & directed.
M&L for preparation of old painted wood and wood base surfaces of any description, not otherwise described over 10 cm width or girth and painting with a coat of sythetic enamel paint complete all as specified and directed
M&L for preparation of old painted Steel and iron surfaces of any description, not otherwise described over 10 cm width or girth and painting with a coat of sythetic enamel paint complete all as specified and directed
SMART PERIODICAL:- (InternalSurface) M&L for preparation of old surface by complete removal of existing treatment mechanically complete all as specified and directed.
M&L for applying 3mm thick wall care putty making smooth surface complete all as specified and directed.
M&L for applying one coat of primer complete all as specified and directed.
M&L for applying Two coat of OBD by using roller complete all as specified and directed
M&L for applying one coat of OBD by using roller complete all as specified and directed
SMART PERIODICAL:- (External Surface) M&L for preparation of old surface of wall after complete removal of existing treatment by mechanically complete all as specified and directed.
M&L for applying 3 mm thick wall care putty making smooth surface complete all as specified and directed.
M&L for one coat of exterior primer applied @ 2.20 kg / 10 Sqm by using roller complete all as specified and directed.
M&L for two coat of acrylic smooth two or more coat applied @ 1.67 ltr/ 10 sqm using roller for painting complete all as specified and directed.
M&L for one coat of acrylic smooth coat applied @ 1.67 ltr/ 10 sqm using roller for painting complete all as specified and directed.
M&L for preparation of Old surfaces and apply one coat of cement base paint to walls complete all as specified and directed
M&L for preparation of Old surfaces and apply two coat of cement base paint to walls complete all as specified and directed
Preparing old Plastered or unplastered surfaces of walls and applying two coat of white wash complete all as specified and directed
Preparing old Plastered or unplastered surfaces of walls and applying two coat of colour wash complete all as specified and directed
Dismantling of cast iron ,PVC or reinforced concrete drain pipes, 75/110/150/200 mm dia, jointed in cement mortar and taking out of trenches, if required, Complete all as specified and directed by Engr-in-charge.
S & F 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls complete all as specified and as directed by the Engineer-in-Charge
S & F 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls complete all as specified and as directed by the Engineer-in-Charge
M & L repair to overhang portion of chajja, facia, dropwall etc. for continuous work by providing PCC(1:2:4) Type B-0 and finished with CM(1:3) after taking down of damaged portion of RCC work by maintaining same level and finished the surface to match with the existing surface by providing same finish. (Height of work to be considered above 3.5m and upto 7m from FFL of Ground Floor.) (Note : Wherever reinforcement is required to be provided will be paid separately under relevant item and contractor have to inform the department one day in advance after binding of reinforcement for measurement otherwise no payment will be considered on this account)
M & L for repairing existing RCC structure work by gunting to damaged edge bottom of beam , chajja, slab 40 to 60mm thick and part of RCC member in CM 1:3 & depositing material/ mortar with spray gun under a pressure of 20 to 30 N/CM2 including skefolding and welding wire mess 2 mm dia and size of wiremesh 50mm X 50 mm including cutting welding and placeing position as directed by Engr in-charge.
M & L for cutting of bushes small trees (Peepal small plants etc) trunks shrubs of any dia and girth from roof projection, chajjas , wall junction parapet etc at any height by necessary demoliton of brick work etc if requried and making good distrubed surfaces to match with existing finihes with and incl material and labore in CM 1:4 mixed with WPC /PCC 1:3:6 type B0 /Bk work in CM 1:4 as required at site and as directed by Engr-in-Charge
M/s D.K.Enterprises
M/S AVADH ENTERPRISES
M/S AMAR ELEKTRO CENTRE
Arun Construction Co.
VIRAT CONSTRUCTIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .