Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | Qualified Make: Bharat Surgical Impex
Model: BSI 9009 00 JAGRANI DEVI MATADEEN KA PURA SHANTIPURM SHANTIPURAM ALLAHABAD UTTAR PRADESH 211013 UDYAM UP 03 0123603 | PRAYAGRAJ | UTTAR PRADESH | 211013 | Make: Bharat Surgical Impex
Model: BSI 9009 | - | - | Qualified |
| 2 | L1₹1.4 LDisqualified Make: NA
Model: Khera pcb 00 JAGRANI DEVI MATADEEN KA PURA SHANTIPURM SHANTIPURAM ALLAHABAD UTTAR PRADESH 211013 UDYAM UP 03 0123603 | PRAYAGRAJ | UTTAR PRADESH | 211013 | Make: NA
Model: Khera pcb | ₹1.4 L | L1 | Disqualified |
| 3 | Disqualified Make: NA
Model: 1114 ASE 27 NIRBHAY ASHWIN NAGAR MUMBAI AGRA ROAD CIDCO NASHIK MAHARASHTRA 422009 | NASHIK | MAHARASHTRA | 422009 | Make: NA
Model: 1114 | - | - | Disqualified |
| 4 | Disqualified Make: NA
Model: Dalmia 1900-900 21 C INDUSTRIAL ESTATE OPP POLICE LINE GANGA NAGAR | Make: NA
Model: Dalmia 1900-900 | - | - | Disqualified |
| 5 | Disqualified Make: UNITED
Model: UNITED PATIENT CARE BED 15 DONGRO DODA MOHELEA DODA JAMMU KASHMIR 182201 UDYAM JK 05 0012809 01BOSPA9209Q1ZJ R S | DODA | JAMMU AND KASHMIR | 182201 | Make: UNITED
Model: UNITED PATIENT CARE BED | - | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
31 May 2018, 11:00 amClosed
patient care beds for general use Experience with Gov. Required 5 Year (s) Patient Care Beds For General Use ( 10 ) Technical Specifications Specification Specification Name Values Allowed Values DIMENSIONS OF MATTRESS PLATFORM & FRAME Length of mattress platform & Overall length of bed >=2000 mm & <=2100 mm >= 1900 mm & <=2000 mm
>=1950 mm & <= 2050 mm
>=2000 mm & <=2100 mm
>= 2050 mm & <=2100 mm
>=2100 mm & <=2150 mm
>= 2150 mm & <= 2200 mm
>= 2200 mm & <= 2250 mm Width of mattress platform 900 mm to 920 mm 900 mm to 920 mm
>920 mm to 950 mm
>950 mm to 1000 mm
>1000 mm to 1050 mm Material of mattress platform surface CRCA Sheet CRCA Sheet
SS Height of mattress platform 617.5 - Mattress platform surface thickness 1.2 mm and above - Type of mattress platform With Holes Perforated
With Holes 1/3 BED Overall length of Bed(in mm): 2060 - FRAME section
dimensions
thickness and material MS ERW rectangular tube with 50 mmx30 mm or more
gauge 1.2 mm or more. - Frame width (in mm) 910 - Leg Shoe material NA - HEAD AND LEG BOARD Height of Head board measured from mattress platform 350 - Material of Leg board and head board MS tubular SS laminated
MS tubular
Plastic Height of Leg board 350 - Pipe diameter of Head and Leg Boards 30 mm or more - Thickness of pipe of Head and Leg board 1.2 mm or more - MISC Maximum Load Capacity must be >= 150 Kg Yes - Painting Powder coated Powder coated Colour of Bed white - Provision of I.V. poles Holder Yes - Provision of Mosquito net pole Holder Yes - Other details Drawing available on Web. false - If Yes
Drawing No. NA - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Alka Gupta 226023
ESIC hospital
Sarojini nagar
Kanpur Road
Near Literacy house
Lucknow
uttar pradesh-226023 10 15 EMD Required No ePBG 2/3 Required No
67404
GEM/2018/B/9613
patient care beds for general use
15 days
Uttar Pradesh; Lucknow
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| patient care beds for general use Experience with Gov. Required 5 Year (s) Patient Care Beds For General Use ( 10 ) Technical Specifications Specification Specification Name Values Allowed Values DIMENSIONS OF MATTRESS PLATFORM & FRAME Length of mattress platform & Overall length of bed >=2000 mm & <=2100 mm >= 1900 mm & <=2000 mm | - | - | - |
| >=1950 mm & <= 2050 mm | - | - | - |
| >=2000 mm & <=2100 mm | - | - | - |
| >= 2050 mm & <=2100 mm | - | - | - |
| >=2100 mm & <=2150 mm | - | - | - |
| >= 2150 mm & <= 2200 mm | - | - | - |
| >= 2200 mm & <= 2250 mm Width of mattress platform 900 mm to 920 mm 900 mm to 920 mm | - | - | - |
| >920 mm to 950 mm | - | - | - |
| >950 mm to 1000 mm | - | - | - |
| >1000 mm to 1050 mm Material of mattress platform surface CRCA Sheet CRCA Sheet | - | - | - |
| SS Height of mattress platform 617.5 - Mattress platform surface thickness 1.2 mm and above - Type of mattress platform With Holes Perforated | - | - | - |
| With Holes 1/3 BED Overall length of Bed(in mm): 2060 - FRAME section | - | - | - |
| dimensions | - | - | - |
| thickness and material MS ERW rectangular tube with 50 mmx30 mm or more | - | - | - |
| gauge 1.2 mm or more. - Frame width (in mm) 910 - Leg Shoe material NA - HEAD AND LEG BOARD Height of Head board measured from mattress platform 350 - Material of Leg board and head board MS tubular SS laminated | - | - | - |
| MS tubular | - | - | - |
| Plastic Height of Leg board 350 - Pipe diameter of Head and Leg Boards 30 mm or more - Thickness of pipe of Head and Leg board 1.2 mm or more - MISC Maximum Load Capacity must be >= 150 Kg Yes - Painting Powder coated Powder coated Colour of Bed white - Provision of I.V. poles Holder Yes - Provision of Mosquito net pole Holder Yes - Other details Drawing available on Web. false - If Yes | - | - | - |
| Drawing No. NA - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Alka Gupta 226023 | - | - | - |
| ESIC hospital | - | - | - |
| Sarojini nagar | - | - | - |
| Kanpur Road | - | - | - |
| Near Literacy house | - | - | - |
| Lucknow | - | - | - |
| uttar pradesh-226023 10 15 EMD Required No ePBG 2/3 Required No | - | - | - |
Exempted
31 May 2018
8 May 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_67404.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .