Loading…
Loading…
| # | Company | Amount | Status |
|---|---|---|---|
| 1 | ₹36.7 LAdmitted-Finance | Admitted-Finance | |
| 2 | ₹36.8 LAdmitted-Finance | Admitted-Finance |
| Sl No | Description | Qty | Unit | Trade Linkers Associates | M/S JCM CONSTRUCTIONS |
|---|---|---|---|---|---|
| 1.00Design, Engineering. Manufacture,workshop testing, supply including packing and forwarding, transportation, delivery at site storage charges of;- | |||||
| 1.10MAIN EQUIPMENTS | |||||
| 1.20ISOLATORS | |||||
| 1.30 | 145KV,50C/S,2500A,SCADA compatible ,40 KA for one sec,AC motor operated horizontal double break, outdoor type 3 pole isolators with one earthing switch.COPPER FIXED AND MOVING CONTACTS CU CURRENT CARRYING PARTS,GALVANISED IRON MECHANISM BOX as per specific technical requirement. | 2 | Sets | 8,50,000 ₹8,50,000 | 6,72,000 ₹6,72,000 Lowest |
| 1.40 | 145KV,50C/S,2500A,SCADA compatible ,40 KA for one sec,AC motor operated horizontal double break, outdoor type 3 pole isolators without earthing switch.COPPER FIXED AND MOVING CONTACTS CU CURRENT CARRYING PARTS,GALVANISED IRON MECHANISM BOX as per specific technical requirement. | 1 | Set | 4,05,000 ₹4,05,000 | 2,86,087 ₹2,86,087 Lowest |
| 1.50Current Transformer | |||||
| 1.60 | Supply of Single phase, 50 c/s 145KV Current Transformers (1200-600-300/1-1-1-1-1-1 A or as per specific technical requirement), 31.5KA for one second, rated dynamic current 100KA(peak), Class A insulation, Burden 20 VA. | 6 | Nos | 12,12,000 ₹12,12,000 Lowest | 13,73,946 ₹13,73,946 |
| 1.70Potential Transformer | |||||
| 1.80 | Supply Single phase, 50 c/s 132KV Voltage Transformers (132/√3) KV/(110/√3)V, One min power freq withstand 275KVrms GALVANISED TANK Acc Class 0.2 as per specific technical requirement | 6 | Nos | 11,40,000 ₹11,40,000 Lowest | 12,83,946 ₹12,83,946 |
| 2.00Handling, transportation, delivery at site, erection work, testing and commisssioning including cable wiring to the equipments and connections with the C&R Pannels;- | |||||
Tender Value
₹46.5 L
EMD Value
₹92,960
Closing Date
18 Aug 2025, 2:00 pmClosed
Executive Engineer, TLMD-IV, Jammu
Office of Executive Engineer, TLMD-IV, Jammu
Replacement Of 3 Sets of 132KV Isolators, 6No. 132KV CTs And 6No. 132KV PTs At 50MVA, 132/33KV Grid Substation Katra
2025_PDD_280791_1
TLMD-IV/J/07 Dated 26-06-2025 of 2025-26
Open Tender
Electrical Works
Turn-key
120 days
Gss Katra
As per SBD and NIT
3 documents required · 3 mandatory
₹2,000
Executive Engineer,TLMD-IV,Jammu
₹92,960
Yes
Office of Executive Engineer, TLMD-IV, Jammu
19 Sept 2025
8 Jul 2025
20 Aug 2025
8 Jul 2025
18 Aug 2025
18 Jul 2025
9 Jul 2025 - 15 Jul 2025
12 Jul 2025
Design, Engineering. Manufacture,workshop testing, supply including packing and forwarding, transportation, delivery at site storage charges of;-
MAIN EQUIPMENTS
ISOLATORS
145KV,50C/S,2500A,SCADA compatible ,40 KA for one sec,AC motor operated horizontal double break, outdoor type 3 pole isolators with one earthing switch.COPPER FIXED AND MOVING CONTACTS CU CURRENT CARRYING PARTS,GALVANISED IRON MECHANISM BOX as per specific technical requirement.
145KV,50C/S,2500A,SCADA compatible ,40 KA for one sec,AC motor operated horizontal double break, outdoor type 3 pole isolators without earthing switch.COPPER FIXED AND MOVING CONTACTS CU CURRENT CARRYING PARTS,GALVANISED IRON MECHANISM BOX as per specific technical requirement.
Current Transformer
Supply of Single phase, 50 c/s 145KV Current Transformers (1200-600-300/1-1-1-1-1-1 A or as per specific technical requirement), 31.5KA for one second, rated dynamic current 100KA(peak), Class A insulation, Burden 20 VA.
Potential Transformer
Supply Single phase, 50 c/s 132KV Voltage Transformers (132/√3) KV/(110/√3)V, One min power freq withstand 275KVrms GALVANISED TANK Acc Class 0.2 as per specific technical requirement
Handling, transportation, delivery at site, erection work, testing and commisssioning including cable wiring to the equipments and connections with the C&R Pannels;-
MAIN EQUIPMENTS
ISOLATORS
145KV,50C/S,2500A,SCADA compatible ,40 KA for one sec, AC motor operated horizontal double break, outdoor type 3 pole isolators with one earthing switch.COPPER FIXED AND MOVING CONTACTS CU CURRENT CARRYING PARTS,GALVANISED IRON MECHANISM BOX as per specific technical requirement.
145KV,50C/S,2500A,SCADA compatible ,40 KA for one sec, AC motor operated horizontal double break, outdoor type 3 pole isolators without earthing switch.COPPER FIXED AND MOVING CONTACTS CU CURRENT CARRYING PARTS,GALVANISED IRON MECHANISM BOX as per specific technical requirement.
Current Transformer
Supply of Single phase, 50 c/s 145KV Current Transformers (1200-600-300/1-1-1-1-1-1 A or as per specific technical requirement), 31.5KA for one second, rated dynamic current 100KA(peak), Class A insulation, Burden 20 VA.
Potential Transformer
Supply Single phase, 50 c/s 132KV Voltage Transformers (132/√3) KV/(110/√3)V, One min power freq withstand 275KVrms GALVANISED TANK Acc Class 0.2 as per specific technical requirement
Dismantling and shifting of old equipment along with allied material to divisional stores.
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .