Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹57.8 LAccepted-Finance | 1 | Accepted-Finance Accepted | |
| 2 | 1₹57.8 LRejected-Finance KAMALPUR P O BAIHATA P S KAMALPUR DIST KAMRUP | KAMRUP | ASSAM | 781030 | 1 | Rejected-Finance Rejected |
Tender Value
₹64.2 L
EMD Value
₹1.3 L
Closing Date
23 Jun 2023, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
O EE Rangia-Kamalpur Division(I) Rangia
O/o the EE Rangia-Kamalpur Division(I) Rangia
Improvement of Borkukuria ELIS
2023_ID_31132_1
NIT NO. RKDI/TN/2021/197 DT 08/06/2023
Open Tender
Civil Works - Others
Percentage
180 days
Rangia
Please refer Tender documents.
6 documents required · 6 mandatory
₹2,000
Yes
₹1.3 L
Yes
5 Jul 2023
9 Jun 2023
23 Jun 2023
9 Jun 2023
23 Jun 2023
9 Jun 2023
Amount
Improvement of canal system
Labour charge for dismantling of old CC works of canal structures and carriage the spoils and depositing the same in a safe distance as directed. : Carriage up to lead of 30 M and lift upto 1.50 M
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 15.7.4 In cement mortar
Soling in foundation at all levels including filling intersides, ramming etc complete as directed and of specified thickness with 9 cm brick on flat including sand packing.
CC work in proportion 1:2:4 in foundation / abutment / piers / wing walls etc. with hard broken stone aggregate of size 6 mm to 20 mm including curing with necessary timber shuttering, scaffolding where necessary complete as directed. (Shuttering, scaffolding cost will be paid separately).
1st class brick work in cement mortar in abutment and wing wall, parapet wall etc, including racking out joints and curing etc, complete as directed. (i) in proportion 1:4
12 mm cement plastering including clearing surface and curing, complete as directed. (ii) In proportion 1:4
Neat cement finishing 3 mm thick with cement slurry prepared by mixing 27.50 Kg of fresh cement in appropriate quantity of clean water to cover 10 (ten) SqM of work area and to give a smooth and hard finishing including rounding corners, brooming, curing etc, complete as directed.
Construction of Brick Pillar for Supporting delivery pipe line
Labour charge for dismantling / replacing the old damaged hume pipe of 1200 mm dia of canal structure and carriage of the same upto a lead of 30 M and lift of 2.5 M and depositing the same in a safe distance as directed.
1st class brick work in cement mortar in abutment and wing wall, parapet wall etc, including racking out joints and curing etc, complete as directed. (i) in proportion 1:4
12 mm cement plastering including clearing surface and curing, complete as directed. (ii) In proportion 1:4
Construction of Sign Board
Supply of sign board made of 1.60mm thick MS iron sheet fitted with steel frame of size 1.05 m x 0.75m fixed with 2 Nos. 50mm dia GI (medium) pipes 2.10m above and 0.60m below ground fitted with C.C. work in proportion 1:3:6 and size 0.45m x 0.45m x 0.60m below ground including painting with approved paint including writing letters complete as directed.
Repairing of Transformer Sub Station with LT Line
Jungle cutting including cutting of branches of trees and reclining Bamboos along the alignment of the overhead line providing clearance 1.5M either side and above the line as directed. Clearance must be ensured at the time of charging the line. (Rates as per SOR Electrical, Irrigation Item No. 6.2)
Supplying, Laying and Erection of Conductors of following size and specification for Overhead Line, binding to Insulators and Tensioning with Uniform Standard Sag including Jumpering connection as directed (AAA Rabbit Conductor - 7/3.15 mm) (Irrg. Elect. SOR Sl No. 6.7.1.C)
Supplying and Erection of 11 kV Polymeric Pin Insulator 5 kN on T Cross Arm/ Channel along with GI Pin, GI Nuts & Bolts including Drilling of Holes as directed. (Irrg. Elect. SOR Sl No.6.6.3.B)
Supplying and Erection of 11 kV Porcelain Disc Insulator 45 kN on existing Hardware Fitting on Cross Arm as directed (Irrg. Elect. SOR Sl No.6.6.5.A)
Erection & Commissioning LT whole Current Electronic Energy Meter including making necessary payment to APDCL for Meter Cabinet, Meter Security etc as required and as directed.
Supplying and Erection of 3-φ 11 kV Gang Operated Air Break Switch of following current ratings on existing Channels complete with Operating Pipe and Handle including making of necessary Electrical Connections as directed. 400 Amps (Irrg. Elect. SOR Sl No. 7.2.B)
Supplying and Erection of 3-φ 11 kV Drop Out Fuse Unit of following current ratings on existing Channels complete with Barrel Fuse and making of necessary Electrical Connections as directed. 400 Amps (Irrg. Elect. SOR Sl No. 7.3.B)
Supply & Erection of C.I. Earth Pipe 100 mm dia x 2.5 Metre long perpendicular to the ground including digging of Earth Pit, putting Salt and Charcoal in alternate layers surrounding the pipe as directed (Irrg. Elect. SOR Sl No. 7.9.1.B)
Supply & Erection of 8 SWG G.I. Earth Wire and Earthing of different Substation Items by connecting the existing Earth Pipes with G. I. Lugs as directed (Irrg. Elect. SOR Sl No. 7.9.2.B)
Providing security fencing around the S/S with GI chain link net,woven with 10 SWG wire with mesh 7.5cmx7.5cm to be erected on GI angle 40mmx40mmx5mm,with necessary C C grouting,with a fench height of 1.8 mtr,having a hinged door,fabricated with flat GI strip boundary and cross bracing,complete including supply of all materials excavation refilling etc as required and as directed (Irrg. Elect. SOR Sl No. 7.16)
Supplying including erection of powder coated LT Feeder Panel /Metering Panel for 100 kVA DTR of size (800mm × 1200mm × 400mm) made of 16 SWG CR sheet and 40mm × 40mm × 6mm MS angle having CR sheet roofing containing Cu Busbar and 1 no 200 A 415 V FP MCCB, (50kA) making necessary connection through copper cable complete as directed. (Irrg. Elect. SOR Sl No. 7.11.C)
Repairing of Existing Transformer
Disconnecting the transformer from the 11 kV line of APDCL lifting it from the pad/pole by labourers/ crane and loading it on carriage vehicle and carrying the same to workshop upto a distance of 35 KM and unloading it by manual labour/ crane as required and as directed. (Irrg. Elect. SOR Sl No. 11.1.(B)1) i) For First 35(Thirty Five) KM f) 250 kVA Al
ii) For every Subsequent 10(Ten) KM Opening, Preliminary checking and lifting of Core Coil assembly
Opening, Preliminary checking and lifting of Core Coil assembly. (Irrg. Elect. SOR Sl No. 11.1.(B)2) f) 250 kVA Al
Supply & fitting of new HV coils conforming to original gauge, shape & size and deducting the salvage value of scraps. (Irrg. Elect. SOR Sl No. 11.1.(B)3) f) 250 kVA Al
Supply & fitting of new HV coils conforming to original gauge, shape & size and deducting the salvage value of scraps. (Irrg. Elect. SOR Sl No. 11.1.(B)4) f) 250 kVA Al
Supply & fitting of new ratio switch deducting the salvage value of scraps. (Irrg. Elect. SOR Sl No. 11.1.(B)5) f) 250 kVA Al
Making of core coil assembly, varnishing & heating of core coil assembly in vacuum heat chamber till requisite insulation level is attained. (Irrg. Elect. SOR Sl No. 11.1.(B)6) f) 250 kVA Al
Cleaning the transformer tank, removing dust, dirt, rust etc completely then painting outside & vernishing the inside of tank with approved quality & colour of paints as directed. (Irrg. Elect. SOR Sl No. 11.1.(B)7) f) 250 kVA Al
Tanking of the core coil assembly, making all necessary connections with HV/LV studs/OLTC etc as required. (Irrg. Elect. SOR Sl No. 11.1.(B)12) f) 250 kVA Al
Supply & filling fresh transformer oil conforming to ISS 353/1993 including necessary filtering. (Irrg. Elect. SOR Sl No. 11.1.(B)13) f) 250 kVA Al
Testing of the transformer at workshop after repairing under the supervision of depatmental staff. (Irrg. Elect. SOR Sl No. 11.1.(B)16) f) 250 kVA Al
Carriage of the repaired transformer from workshop to site, reinstallation on pole structure/ pad at substation and complete connection on HV and LV side by skilled labourer under supervision of Electrical Supervisor having trade licence and, testing of the whole installation, then reconnection of power as directed by the department.. (Irrg. Elect. SOR Sl No. 11.1.(B)17) A For First 35(Thirty Five) KM (f) 250 kVA Al B For Every Subsequent 10(Ten) KM
B For Every Subsequent 10(Ten) KM
Repairing of Existing Panel Board
Supplying including fitting, fixing & connection of Four Pole(FP) 415 V, AC MCCB of following current ratings as main incomer in already fabricated LT Control Panel Board Housing along with Lugs, Connecting Cable and all other necessary materials for connections as directed. 630 Amp, Breaking Capacity. 35/36 kA. Rates as per SOR Electrical, Irrigation Item No. 2.1 J
Supplying including fitting, fixing & connection of Three Pole (TP) 415 V AC 50 Hz Motor Protection Circuit Breaker (MPCB) with adjustable Thermal and Magnetic Setting with Rotary Handle of following Current/ HP ratings in already fabricated LT Control Panel Board Housing along with Lugs, Connecting Cable and all other necessary materials for connections as directed. 100 A 75 H.P. Rates as per SOR Electrical, Irrigation Item No. 2.3 G
Supplying including fitting, fixing & connection of Three Pole (TP) 415 V AC 50 Hz Miniature Circuit Breaker (MCB) C Curve with breaking capacity of 10 kA and of following current ratings in already fabricated LT Control Panel Board Housing along with Lugs, Connecting Cable and all other necessary materials for connections as directed. 100 A. Rates as per SOR Electrical, Irrigation Item No. 2.4 F
Supplying including fitting, fixing & connection of Three Pole (TP) 415 V AC 50 Hz Air Break Contactor (ABC) of following current ratings in already fabricated LT Control Panel Board Housing along with Lugs, Connecting Cable and all other necessary materials for connections as directed. 100 A. Rates as per SOR Electrical, Irrigation Item No. 2.5 E
Supplying including fitting, fixing & connection of TP (Three Pole) Main Switch (SDFU - Switch Disconnector Fuse Unit) with HRC Fuses, 415 V AC, Open Execution, Panel Mounting Type of following current ratings in already fabricated LT Control Panel Board Housing along with Lugs, Connecting Cable and all other necessary materials for connections as directed. 250 A. Rates as per SOR Electrical, Irrigation Item No. 4.1 G
Supplying including fitting, fixing & connection of TPN Main Switch Fuse Unit (SFU),415 V AC, Rewirable Type in Sheet-Steel Housing of following current ratings to be fitted in existing Angle Iron Frame/Wall with Clamps, Nuts & Bolts and all other necessary materials as directed including drilling of holes as required. 315A/320A. Rates as per SOR Electrical, Irrigation Item No. 2.3 G
Construction of Boundary Wall
Centrifugal pump set with 156 LPS minimum discharge at 13 Mtrs Head, working efficiently at head range {13 - 21) Mtrs coupled with 40 HP induction motor. Pump, Motor, Starter should be of reputed brand and as per IS Specification. MOTOR : Conforming to IS : 325 - 1978 1. M a k e : MARATHON/ LUBI/ Kirloskar/ Crompton/ Havells 2. Type/ Model : Squirrel Cage TEFC 3. H P : 40 HP 4. R P M : 1450 5. Supp ly Voltage/ P h ase/ Cycle : 415 V ± 10% 3 PH/ 50 Hz 6. Class of Motor lns.ulation : F PUMP :- Conforming to IS : 6595 Part - I 1. Make : LUBI/ Kirloskar 2. Type : Horizontal Axially Split Casing 3. M o d e l : LHC 200- 250/ UP 250/30 4. Size { Suction X Del ivery) : 250 mm x 200 mm/ 250 mm x 250 mm 5. Head Range : 13-21 M 6. Pump Input : 23.30 KW 7. Efficiency at duty P o i n t: 82.7% STARTER: SUITABLE TO RUN ABOVE PUMP SETS: 1. Make : BCH/ Havells/ Equivalent 2. Model : NASACT ILEM 3. T ype: FASO 4. Relay Range : 24 - 39 A
Installation of Centrifugal Pump set (Horizontal Split casing type, size: 150 mm(suction) x 125 mm dia. (delivery) of 60 LPS minimum discharge at 18.00 Mt head coupled with 3 ph, 415 V, 50 Hz, 1450 RPM squirrel cage induction motor of 40 HP complete set. The job includes necessary transportation of pump set to the site and installation of C.C. block foundation in proper position with accurate alignment by means of foundation nuts and bolts complete with all works.
Pump Shaft Nut (MS) for the Pump of capacity 40 HP
Gun Metal bushing for the Pump of capacity 40 HP.
MS Sleeve for the Pump of capacity 40 HP.
Bearing cover D.E. for the Pump of capacity 40 HP.
Bearing cover N.D.E. for the Pump of capacity 40 HP.
Pump Bearing cover D.E. for the Pump of capacity 40 HP.
Pump Bearing cover N. D.E. for the Pump of capacity 40 HP.
MS coupling complete with Nuts & Bolts & washer for the Pump set of capacity 40 HP. (Mecha SOR of Additional CE. Item No- F.14. b)
Starter for Induction Motor, 40 HP with relay range 28-42 Amp. (Mecha SOR DPC. Item No-8. ii)
CI Foot Valve: Heavy Duty CI Foot Valve, Flange type, the holes of the flange should be drilled as per BSS No. 10, Part-1, Table-D. The materials of construction and all components of the Foot Valve should strictly conform to IS : 10805 - 1986 and having marked with manufacturer’s name and trade mark. (Size: 300mm dia) (Mecha SOR NIQ No.2. Item No-5. V)
CIDF Sluice Valve of mm dia, Make : Kirloskar/ Upadyaya/Zolato/Venus & Eqv. (Mecha SOR NIQ No.2. Item No-6. V)
CI Bend: CIDF Bend. As per specification having holes of flanges as per BSS NO 10, Part-I, Table-D. Size 300mm dia x 90º (Mecha SOR NIQ No.2. Item No-2. VII)
High Density Polyethylene (HDPE) water delivery pipes with pressure nominal 6 to 10 bar(PN 6 to PN10) & manufactured with materials grade confiring to PE80 or PE100 as per IS:4984 of 1995 with MS flange at both end having drilled as per BSS No. 10 Part-1, Table-D. (x)315mm OD x 6.00 mtrs Long. (Mecha SOR NIQ No.2. Item No-15. X)
Installation, fitting, fixing of 1.0 HP mono block pump set (excluding cost of pump set), pipes and accessories for priming system at each point of a ELIS. The job consists of supply and fitting of items like Flexible PVC pipe, GI pipe, GI Tee, GI Elbow, GI Nipple, GI Socket Bronze valve, Foot valve, PVC insulated copper conductor etc and labour charges. Rate as per CE SoR (Mech) 2019-20 (LIS part) Sl No. 2.7
Deraj Saikia
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .