| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.6 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹40.6 L+₹8.0 L (24.6%)Rejected-Finance | L2 | Rejected-Finance Being other than L1 | |
| 3 | L3₹42.8 L+₹10.2 L (31.5%)Rejected-Finance 195 MAHESH NAGAR AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | L3 | Rejected-Finance Being other than L1 | |
| 4 | Rejected-Technical | - | Rejected-Technical Adverse remarks in WLR |
Tender Value
₹44 L
EMD Value
₹88,000
Closing Date
16 Nov 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NAMS
GE NAMS AMRITSAR
REPAIR/MAINT OF LT OH LINES, UG CABLES AND ALLIED WORKS AT NAMS
2022_MES_558394_1
GE NAMS-28/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE NAMS
CLASS D CATEGORY b(i)
8 documents required · 8 mandatory
₹500
GE NAMS
₹88,000
Yes
2 Jan 2023
18 Oct 2022
18 Nov 2022
18 Oct 2022
16 Nov 2022
2 Nov 2022
Amount
Excavation in trenches in soft/ loose soil not exceeding 1.50 m wide and not exceeding 1.50 m in depth for foundation of poles, stay, cable, pipes etc and getting out complete all as specified.
Excavation in trenches n. exc 1.5 mtr wide and exc 1.5mtr but n exc. 3.0mtr in depth for foundation of pole and getting out in any type of soil complete all as specified and directed.
Returning, filling, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick each complete all as specified.
Removal of surplus soil to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified.
Boring of trench under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine for road crossing GI tubing of any size for cable protection complete all as specified and directed.
Supply laying in replacement & testing cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (Heavy duty) LT 1100 volt grade with stranded aluminium conductor of size 300 sqmm 3.5 core complete all as specified and directed.
Supply laying in replacement & testing cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (Heavy duty) LT 1100 volt grade with stranded aluminium conductor of size 185 sqmm 3.5 core complete all as specified and directed.
Description as per item ser No 7.00 here-in-before but of size 120 Sqmm 3.5 core.
Description as per item ser No 7.00 here-in-before but of size 95 Sqmm 3.5 core.
Description as per item ser No 7.00 here-in-before but of size 70 Sqmm 3.5 core.
Description as per item ser No 7.00 here-in-before but of size 50 Sqmm 3.5 core.
Description as per item ser No 7.00 here-in-before but of size 35 Sqmm 3.5 core.
Description as per item ser No 7.00 here-in-before but of size 25 Sqmm 4 core.
Description as per item ser No 7.00 here-in-before but of size 16 Sqmm 4 core.
Description as per item ser No 7.00 here-in-before but of size 16 Sqmm 2 core.
S&F in replacement 70 Sqmm single core heavy duty insulated cable suitable for 11 KV from top disc insulator to GOD and disc to disc in any lenth with complete nuts & thimbles all as required at site.
M&L for Plain cement concrete 1:2:4, nominal mix, type B-1, using 20mm graded crushed stone aggregate as in coping and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work, complete all as specified.
M&L for Plain cement concrete 1:3:6, (nominal mix), type C-2, using 40mm graded crushed stone aggregate as in foundation, filling and mass concrete, complete all as specified & directed.
Supply, laying & fixing in replacement double wall corrugated (DWC) pipes made of high density polythyline (HDPE) with all accessories i.e. all type of joints, Sockets, Elbows, bends and End caps etc all as specified and directed by Engr in Charge of size 77mm outer dia and 63mm inner dia
Description as per item ser No 19.00 above but 63 mm outer dia and 50mm inner dia
Description as per item ser No 19.00 above but 90 mm outer dia and 75mm inner dia
Supply & fixing in replacement of MCCB Capacity 36 KA, 4 pole, 400 Amps adjustable type with separator and aluminium lugs all as required at site.
Description as per item ser No 22.00 above but 350 Amp 36 KA
Description as per item ser No 22.00 above but 250 Amp 36 KA
Description as per item ser No 22.00 above but 100 Amp 16 KA , TP, fixed type
Description as per item ser No 22.00 abovebut 200 Amp 36 KA, 4P adjustable type
Description as per item ser No 22.00 above but 160 Amp 36 KA , TP with microprocessor release
Supplying, fixing and erecting truly to vertical position steel tubular swaged pole complete with base plate welded with pole, finial taper plug, bolt, nut and screws as specified type 410 SP-31 (9m long) including one coat of red-oxide zinc chrome primer and two coats of aluminium paint on surfaces exposed to view and making 30cm wide strips (total 5 Nos) with white and black paint alternately on external surface above plain cement concrete benching including numbering with black paint and painting with bituminous paint internally complete and externally for portion embedded in PCC, complete all as specified and directed (PCC, earth work shall be measured & paid separately under respective items).
M & L in replacement Structural steel work as in cross arms, bracings, supports, clamp and back plate fabricated from steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed by Engineer-in-Charge and applying two coats of aluminium paint over one coat of red oxide zinc chrome primer including preparation of surfaces, complete all as specified & directed
M&L for Pin type porcelain white, brown or green insulator in replacement including one galvanized mild steel spindle, two galvanised iron washers & one galvanised nut 50mm height, 65mm dia for working pressure 1100 volts grade.all as specified and directed by Engr-in charge
Supply & fixing in replacement of Stay Assembly using stay rod of 16mm dia complete with galvanized stay strand of size 7/4mm & accessories as shown in Electrical Plate No 1 of SSR 1991 Part-I, complete all as specified ( earth work and plain cement concrete shall be measured and paid for separately)
Material and labour in replacement for Aluminium conductor steel reinforced (ACSR) of any size for over head lines on existing poles, stretching without kinks and bends including binding wire, complete all as specified and directed by Engr-in charge.
Supply and laying or fixing in replacement 1100 Volts grade heavy duty cable with PVC insulated aluminium standard conductor served with an inner sheathing of PVC tape and over all PVC Sheathed in service connections , one twin core 10 Sqmm cable standard conductor cable flat or circular all as specified and directed by Engr- in- Charge.
Supply and laying or fixing in replacement 1100 Volts grade heavy duty cable with PVC insulated aluminium standard conductor served with an inner sheathing of PVC tape and over all PVC Sheathed in service connections , one twin core 16 Sqmm cable standard conductor cable flat or circular all as specified and directed by Engineer- in- Charge.
M & L in replacement of out door type aluminuam bus bar chamber feeder box of cap 400 Amp , 3 phase, 4 wire, 415 Volts including 300 Amp , 4 Pole MCCB Thermal magnatic release and porcelain insulator, chamber should not less than 90 x 60 x 45 cm made out of 3.15 mm CRCA Sheet duly painted with two coats of synthetic enameld paint over a red oxide primer and fixed and supported with anlge iron of size 40mm x 40mm x 6mm grouted in PCC 1:2:4 upto 0.60 mtr high from ground level all as directed by Engr-In-Charge. Note Contractor will be responsible for approval of drawing from Garrison ENginner before placing the order.
M&L in replacement of Earthing complete with galvanized steel earth plate electrode 600x600x6mm burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of earth plate not less than 1.5m below normal ground level connected with galvanized iron earth lead strip of 32x6mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel complete with 40mm dia, 7.5 mtr long GI light grade protection pipe, 40mm dia GI medium grade watering pipe with funnel including charcoal, dust, salt, plain cement concrete 1:2:4 in pit with pre- cast RCC 1:2:4 cover reinforced with XPM not less than 4 Kg per Sqm, test point etc. all as shown in electric plate No. 3 of SSR Part-I complete with necessary earth work in any type of soil, removal to a distance not exc. 50m, testing on completion complete all as specified & directed. Note :- All joints either strip to strip of strip to earth plate are fixed with welded joints.
Material and labour for repairing existing LT Panel doors complete with new locking arrangement complete all as specified and directed. Note: Any part/spare found defective such as packing, nuts bolts, hinges & welding machine works etc shall be repaired/replaced for which cost shall be deemed to be included in the unit rate quoted for this item.
Material and labour for preparing old painted surface of panel board by cleaning removing of old paint by scratching with wire brush / sand paper etc and including denting of broken / rusted surface and applied two coat of synthetic surface enamel paint by spray painting outside surface of panel as existing colour of panel all as specified and directed.
Material & labour for painting to mild steel cross arms, bracing, supports, clamps, back plate etc fixed on LT Poles any height with providing two coats of aluminium paint over a coat one coat of red oxide primer complete all as specified and directed. Note:- Steel members fixed on single LT pole shall be considered as 'One Unit'.
Material & labour for painting of steel / PCC poles with two coats of synthetic enamel paint in black and white strip 30 cm wide each up to 1.5 mtr height from coping including preparation of old painted surfaces and numbering of poles complete all as specified and directed.
Material and Labour straight through joint heat shinkable, out door type suitable for upto 95 sqmm LT 3.5 core 1100 volts XLPE cable type complete all as specified and directed.
Material and Labour straight through joint heat shinkable out door type suitable for 120 sqmm LT 3.5 core 1100 volts XLPE cable type complete all as specified and directed.
Material and Labour straight through joint heats shinkable out door type suitable for 185 sqmm to 300 sqmm LT 3.5 core 1100 volts XLPE cable type complete all as specified and directed.
M&L in replacement for danger notice plate of 1.6mm thick mild steel sheet, vitreous enameled white, with letter , figures and conventional skull and bones in signal red colour and fix with MS clamps, bolts and buts of approved size, for LT 20x15 cm complete all as specified and as directed
Material and labour in replacement as per existing for prepairing for distrubution diagram of external services / sub stn diagram including replacement of old fainted diagram and make flex board of size not less than 1500mm x 1000mm complete all as specified and as directed.
Supply and Fix in replacement high grade PVC LT overhead phase to phase line spacer suitable for 4 lines , suitable for verticale and horizontal line complete all as specified and as directed.
Supply and Fix in replacement high grade PVC LT overhead phase to phase line spacer suitable for 5 lines , suitable for verticale and horizontal line complete all as specified and as directed.
S & F in repairs/ replacement cable Straight joint kit for 1100 volt, out door type joint complete with all jointing material and accessories suitable for 3.5 / 4 Core cable of size 25 sqmm to 35 sq mm all as directed.
S & F in repairs / replacement cable Straight joint kit for 1100 volt, out door type joint complete with all jointing material and accessories suitable for 3.5 / 4 Core cable of size 50 sq mm all as directed.
S & F in repairs/ replacement cable end joint kit for 1100 volt, out door type joint complete with all jointing material and accessories suitable for 3.5 core cable of size 185 sqmm to 300 sq mm all as directed.
Supply and Install in replacement of factory made outdoor type dust and vermin proof feeder Pillar LT Panel board cubicle double door hinged type of suitable size 415V AC, 50Hz, fabricated of GP/CRCA sheet 3mm thick machine pressed and angle iron frame 50mm X 50mm X 6mm grouted in PCC 1:2:4 type BI (20mm grade stone aggregated) powder coated in seven Tank process inside and outside complete including 4 Pole aluminum Bus Bar of suitable size mounted on porcelain insulator ,concealed hinged door with 3 Positioning door locking arrangement and enclosed in chamber made out of 2mm sheet thick GP/ CRCA sheet machine pressed and connection from incoming and outgoing electric cable with suitable size thimbles/lugs cable gland with open able shutters on both side and comprising of following (i) MCCB 315 Amps 36KA 4pole as a Incomer-01 (ii) MCCB 25 KA 4P 100A -04 (iii) MCCB 25 KA 4P 120Amp -01 (iv) Aluminium Busbar of 500 Amps phase+Nutral with insulated (v) Digital Ammeter and volt meter of suitable size
M&L for spraying anti vegetation chemical liquid of 1.0 ltrs bottle mixed with water as per manufacturer's instructions in installation area / under the LT lines/ along LT Panel area/ around HT/LT Pole structure complete all as per direction of Engr in charge .
Supply and fill up transformer oil topping up having dielectric strength not less than 50 KV at 4 mm gap conforming to IS complete all as specified and directed.
Material and labour for reconditioning of battery including changing of all cells and external portion and battery with terminal for power back up system at MES Power house / DG Set Installation, 12V, 150/180Ah complete make the battery serviceable all as specified and as directed by Engr-in-Charge.
Material and labour for jointing broken/ lying on ground conductor and restrach the same with straching of upto 4 span complete with maintaing proper sag all as specified and as directed. Note :- Conductor required for jointing broken conductor shall be included in the quoted rate. No extra payment shall be made to the contractor for the same.
Excavating, taking out and relaying cables loops near the poles, LT Panels, DB's, transformers, cutting the damages/burnt parts of cable and reconnecting to its position complete with thimbles, nut bolts, sleaves all as specified and directed by Engineer-in-Charge.
S & F in replacement of ACB 800 Amps, 50KA, 4 pole with microprocessor release drawout type complete all as specified and directed by Engineer-In-charge.
Material & labour for restrainging ACSR conductor LT on existing poles, stretching without kinks and bends including binding wire, complete all as specified and directed by Engr-in charge.
Taking out carefully manually by excavation / Pulling of cable with rope of existing LT cable of size 10 Sqmm to 95 Sqmm with loops and relaying with existing DWC pipe after repair/ cutting the damages / burnt parts of cable and reconnecting into original positions complete with cable joints all as specified and directed by Engineer-in-Charge. Note:-(i) LT Cable Joint will be measured and paid sepearetly. (ii) Unit rate shall include for excavation and returning filling.
Taking out carefully manually by excavation / Pulling of cable with rope of existing LT cable of size 120 Sqmm to 240 Sqmm with loops and relaying with existing DWC pipe repair/ cutting the damages / burnt parts of cable and reconnecting into original positions complete with cable joints all as specified and directed by Engineer-in-Charge. Note:-(i) LT Cable Joint will be measured and paid sepearetly. (ii) Unit rate shall include for excavation and returning filling.
Supply and laying synthetic rubber insulation mats 2.5 mm thick for voltage upto 11KV for electrical purpose as per IS 15652-2006 suitable for electrical shock safety of sizes 2m x 1m complete all as specified and directed
Supply and fix electrical shock treatment chart on wooden framed board of size 50cm x 75 cm complate in all respect all as specified and directed
Supply and fix in replacement , equipment history sign board not less than 67.5 Cm in height and 1.2m in length printed with white stickers with complete detail of machinery ( ie name of Installstion, date of Installstion, SM No, MES No, capacity of the mechanary , date of manufacturer, initial Amount , Machinery supplied by the firm, Job No, CA No, other requirements as directed) made of aluminium composit panel not less than 3.0 mm thick duly company painted with the MES blue colour one side and grey colour other side computerised printing white strikers as on blue side for marking the name of installations, duly border with red colour tape as per site requirement and framed with aluminium binder in respect of different locations and installations under GE NAMS. Fixing the same on wall of installations with proper alignment using necessary fasterner with nuts, bolts and washers all as specified and directed by Engr-in-charge.
Material and labour for marking pole number on LT/ street light Pole by painting 120mm dia, black painted circle and 50mm in height numerics in white paint complete all as specified and as directed.
Bharat Builder
Raman Electric Trading Co
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .