GE (AF) UDHAMPUR
GE (AF) STN UDHAMPUR
PROVN OF CERTAIN TOILETS AND ADDN/ALTN TO EXISTING TOILETS AT VARIOUS LOCATIONS AT AF STATION NATHATOP
2025_MES_706984_1
GEAFU-03/2025-26
Open Tender
Civil Works
Item Rate
270 days
GE (AF) UDHAMPUR
GEAFU-03/2025-26
8 documents required · 8 mandatory
₹500
GE (AF) UDHAMPUR
₹88,500
18 Jun 2025
7 May 2025
29 May 2025
7 May 2025
27 May 2025
13 May 2025
7 May 2025 - 10 May 2025
Amount
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed by Engineer-in-Charge.
M&L for Rendering 15mm thick plaster in cement mortar 1:6 on fair face of brick work or concrete surfaces, finished even and smooth w/o using extra cement, complete all as specified and directed by Engineer-in-Charge.
M&L for Rendering 5mm thick on brick masonary surfaces in CM-1:4 with WPC over 10mm thick rendering with CM-1:6 including finish the surface even & fair on wall surface complete all as specified and directed by Engineer-in-Charge. Note : WPC will be measured and paid sepradely.
M&L for Preparing of newly plastered or unplastered surfaces of wall and applying three coats of white wash complete all as specified and directed by Engineer-in-Charge.
M&L for Preparing of newly plastered surfaces of wall and applying Acrylic Smooth exterior paint of required shade : (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed by Engineer-in-Charge.
M&L for 100 mm thick cement concrete (1:4:8) type D2 as sub base to floor complete all as specified and directed by Engineer-in-Charge.
M&L for 25mm thick cement concrete 1:2:4 type B-0 using (12.5mm graded crushed stone aggregates) as in floor and finished even and fair ccomplete all as specified and directed by Engineer-in-Charge.
M&L for 75 mm thick PCC 1:3:6 type C-2 (40mm graded aggregate) as in plinth protection including finish even and smooth surface complete all as specified and directed by Engineer-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer-in-Charge.
M&L for Glazed ceramic coloured tiles 300mm x 450mm x 7-8mm thick as in vertical surfaces such as skirting dado etc set and jointed in neat cement slurry, pointed in white or coloured cement to match over and including 10mm thick rendering in cement mortar 1:4 to receive tiles, complete all as specified and directed by Engr-in-charge.
M&L for Non skid coloured ceramic tiles 7 to 8 mm thick, area of each tiles exc. 0.06 SQM and but n.exc. 0.11 Sqm in floor etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over 15mm thick screed bed in CM 1:6, complete all as specified and directed by Engr-in-Charge.
Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets all as complete all as specified and directed by Engineer-in-Charge..
M&L for Anodised aluminium snap grid frame work size of grid 605x605 mm for false ceiling including all necessary hangers, cleats etc complete all as specified and directed by Engr-in-charge.
M&L for 4mm thick Non asbestos fibre cement building boards, ISI marked, fixed to snap grid frame work 605x605 mm as in ceiling, flat or slopy as per manufacture's instructions complete all as specified and directed by Engr-in-charge.
Taking down Chowkhats or frames exc 1.5 sq. m but n exc 4 sq. m each with shutters (without taking off shutters from the frames) complete all as specified and directed by Engineer-in-Charge.
S&F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. square tube and fixed in opening as per specification and drawing complete all as specified and directed by Engineer-in-Charge.
S&F Factory made solid panel PVC Moulded door shutter 28 to 30mm thick stiles with 2,4 or 6 raised panel design with 2mm thick Moulded PVC sheet on the front face and 2mm thick plain coloure PVC sheet on back face complete all as specified and directed by Engineer-in-Charge.
S&F aluminum anodised handles cast type, 150 mm size (ISI Marked) complete all as specified and directed by Engineer-in-Charge.
S&F aluminium anodised barrel tower bolts of extruded section with 150 mm long bolt (ISI Marked) complete all as specified and directed by Engineer-in-Charge.
S&F extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed,100 mm (ISI Marked) long complete all as specified and directed by Engineer-in-Charge.
S&F in repairs steel water tubing 15 mm bore medium grade galvanised with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings( such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) complete all as specified and directed by Engineer-in-Charge.
S&F in repairs steel water tubing 20 mm bore medium grade galvanised with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings( such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) complete all as specified and directed by Engineer-in-Charge.
Cutting chases in brick wall, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified and directed by Engineer-in-Charge.
S&F in repairs 20mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified complete all as specified and directed by Engineer-in-Charge.
S&F in repairs Vitreous China wash down water closet pan (pedestal pattern) of size 550 x 400mm white (excluding fixing bolts, flushing cistern and flush pipe) including plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminium hinging device complete all as specified and directed by Engineer-in-Charge.
S&F in repairs Vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) complete all as directed
S&F in repairs 10 litres PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete all as specified and directed by Engineer-in-Charge.
S & F Flush pipe of polyethylene of low or high density 32 mm bore for low level cistern complete all as specified and directed by Engineer-in-Charge.
S&F in repairs 15mm wall mixer with provision of overhead shower with 115mm long bend pipe on upper side connecting legs & wall flanges complete all as specified and directed by Engineer-in-Charge. Make : Cat No : FLR-5273UPR of Jaquar or its equivalent.
S&F in repairs 15 mm bore Pillar taps, fancy type, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge.
S&F in repairs PVC connection 15mm bore with PTMT nuts of length 450mm long, complete all as specified and directed by Engineer-in-Charge.
S&F in repairs angle valve, cast copper alloy fancy type screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions of 15 mm bore complete all as specified and directed by Engineer-in-Charge.
S&F in repairs 15 mm dia bib tap fancy type chomium plated, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed, complete all as specified and directed by Engineer-in-Charge.
S&F in repairs Vitreous China wash basin (incl vitreous china Pedestal), white, flat back, size 550 mm x 400 mm excluding tap, incl waste coupling etc chain, plug and porcelain stopper but including brackets and cutting for and pinning in ends of brackets complete all as specified and directed by Engineer-in-Charge.
S&F in repairs Vitreous China Urinal, bowl type, size of 465 x 355 x 265 mm white (excluding flushing cistern, flush pipe and waste pipe), bowl type (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified and directed by Engineer-in-Charge.
S&F in repairs PVC waste pipe of polyethylene of low or high density 32 mm dia,complete all as specified and directed by Engineer-in-Charge.
S&F in repairs Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe (Minimum weight 60 gms) complete all as specified and directed by Engineer-in-Charge.
S&F in repairs brass chromium plated tubular towel rail, 20mm dia, D type, 60 cm long between flanges complete all as specified and directed by Engineer-in-Charge.
S&F in repairs CP Brass Toilet paper holder fixed to walls with screws complete all as complete all as specified and directed by Engineer-in-Charge.
S&F in repairs Brass chromium plated shower rose 125mm size with shower arm 15mm size and 195mm long complete all as specified and directed by Engineer-in-Charge.
S&F in repairs CP single lever basin mixer without popup waste system & 450mm long braided hoses complete all as specified and directed by Engineer-in-Charge. Make : Cat No : VGP-81011B of Jaquar or its equivalent.
S&F in repairs glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long fixed with and including Chromium plated brass screws and wooden/plastic cleats etc complete all as directed.
S&F in repairs CP Health faucet with 1 Mtr tube and hook complete all as specified and directed by Engineer-in-Charge. Make : Cat No : ALD-579 of Jaquar or its equivalent.
S&F in repairs Grating doom 100mm bore of PTMT complete all as specified and directed by Engineer-in-Charge.
S&F in repairs Grating doom 100mm bore of PTMT with waste hole complete all as specified and directed by Engineer-in-Charge.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed by Engineer-in-Charge.
S&F 110/100mm PVC (SWR) 'P' trap complete all as specified and directed by Engineer-in-Charge.
S&F 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed by Engineer-in-Charge.
S&F 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to wall complete all as specified and directed by Engineer-in-Charge.
S&F 110 mm bore PVC (SWR) junction double, (double T), equal or unequal complete all as specified and directed by Engineer-in-Charge.
S&F 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed by Engineer-in-Charge.
S&F 110 mm bore PVC (SWR) bend (any radius) complete all as specified and directed by Engineer-in-Charge.
S&F 75 mm bore PVC (SWR) bend (any radius) if provided with access door complete all as specified and directed by Engineer-in-Charge.
S&F 110 mm bore PVC (SWR) vent cowl complete all as specified and directed by Engineer-in-Charge.
M&L 75 mm bore PVC (SWR) floor trap, plain with grating including jointing with solvent cement fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed by Engineer-in-Charge.
S&F in repairs pegs set of six hooks, solid body,300mm long made of aluminium body complete all as specified and directed by Engineer-in-Charge.
S&F in repairs Soap dish, any type, fixed to plugs with chromium plated brass screws complete all as specified and directed by Engineer-in-Charge.
Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed by Engineer-in-Charge.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m depth for foundation etc, manholes n.exc 10 sqm on plan and n.exc 1.5 m in depth and getting out any type of soil complete all as specified and directed by Engineer-in-Charge.
M & L for PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundation filling & Mass concerete complete all as specified and directed by Engineer-in-Charge.
Returning filling in including spreading, levelling, watering and well ramming in layers n.exc 25 cm thick , including watering ,ramming complete all as specified and directed by Engineer-in-Charge.
Removing of soil to distance exc 50 mtr and n.exc 250 mtr depositing at a level n.exc 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-Charge.
M & L for RCC M-25 Design Mix as in foundations including rafts, footings, foundation beams, plinth beams, bases for columns, etc. basement slabs, under-reamed piles and mass concrete complete all as specified and directed by Engineer-in-Charge.
M & L for RCC M-25 Design Mix as in column ,pillars,piers posts struts complete all as specified and directed by Engineer-in-Charge.
M & L for RCC M-25 Design Mix as in beams ,cantilevers ,bressummers ,lintels over 1.5 mtr span complete all as specified and directed by Engineer-in-Charge.
M&L for RCC M-25 Design Mix as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and directed by Engineer-in-Charge.
M & L for formwork to sides of concerete foundation, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work ; vertical or to batter rough finished surfaces of concerete complete all as specified and directed by Engineer-in-Charge.
M & L for formwork to sides and soffits of floors or roof beams, beam haunchings ,girders, bressummers, lintels, cantilevers, shelves including sup-ports, overhangs etc also splays between floors and beams etc complete all as specified and directed by Engineer-in-Charge.
M & L for formwork to side of piller, posts, struts, piers, columns and stanchions of Rough finished square, rectangular or polygonal surfaces of concerete complete all as specified and directed by Engineer-in-Charge.
M & L for formwork to soffits of suspended flat slabs such as roof slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed by Engineer-in-Charge.
M & L for TMT bar 10mm dia and over cut to length, bent to shape as required and binding with MS wire n.less than 0.9 mm dia annealed complete all as specified and directed by Engineer-in-Charge.
M&L for TMT bars 5 to 10 mm dia as in stirrups complete all as specified and directed by Engineer-in-Charge.
M&L for Brick work with sub class B bricks straight or curved on plan any radius in half bricks thick wall built in cement mortar 1:4 complete all as specified and directed by Engineer-in-Charge.
M&L for Brick work with sub class 'B' bricks, straight or curved on plan exc 6 m mean radius, built in cement mortar 1:6 complete all as specified and directed by Engineer-in-Charge.
M&L for Rendering 5 mm thick plaster in CM 1:3 on ceiling surface finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L for Preparing of newly plastered or unplastered surfaces of ceilling and applying three coats of white wash complete all as specified and directed by Engineer-in-Charge.
S&F Steel ventilator with top hung shutter including hinges, steel peg stay, complete all as specified and directed by Engineer-in-Charge.
S&F 4mm thick Figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane complete all as specified and directed by Engineer-in-Charge.
M&L for 75mm thick PCC 1:3:6 type C-2 as in plinth protection including finish even and smooth surface complete all as specified and directed by Engineer-in-Charge.
S&F for steel water tubing 15 mm bore medium grade galvanised with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings( such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) complete all as specified and directed by Engineer-in-Charge.
S&F for steel water tubing 20 mm bore medium grade galvanised with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings( such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) complete all as specified and directed by Engineer-in-Charge.
S&F 20mm dia, Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge.
S&F Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) including plastic water closet seal, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminium hinging device complete all as specified and directed by Engineer-in-Charge.
S&F 15mm bore wall mixer with provision of overhead shower with 115mm long bend pipe on upper side connecting legs & wall flanges complete all as specified & directed. Make : Cat No : FLR-5273UPR of Jaquar or its equivalent.
S&F PVC connection 15mm size with PTMT nuts of length 450mm, complete all as specified and directed by Engineer-in-Charge.
S&F angle valve, cast copper alloy fancy type screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions of 15 mm bore complete all as specified and directed by Engineer-in-Charge.
S&F 15 mm dia bib tap fancy type chomium plated, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed, complete all as specified and directed by Engineer-in-Charge.
S&F Vitreous China wash basin (incl vitreous china Pedestal), white, flat back, size 550 mm x 400 mm excluding tap, incl waste coupling etc chain, plug and porcelain stopper but including brackets and cutting for and pinning in ends of brackets complete all as specified and directed by Engineer-in-Charge.
S&F Vitreous China Urinal, bowl type, size of 465 x 355 x 265 mm white (excluding flushing cistern, flush pipe and waste pipe), bowl type (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified.
S&F Vitreous China Urinal, squatting plate urinal, white (excluding flushing cistern, flush pipe and waste pipe), bowl type (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified.
S&F PVC waste pipe of polyethylene of low or high density 32 mm bore, complete all as specified and directed by Engineer-in-Charge.
S&F Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe (Minimum weight 60 gms) complete all as specified and directed by Engineer-in-Charge.
S&F for brass chromium plated tubular towel rail, 20mm dia, D type, 60 cm long between flanges complete all as specified and directed by Engineer-in-Charge.
S&F Brass chromium plated Toilet paper holder fixed to walls with screws complete all as specified and directed by Engineer-in-Charge.
S&F Brass Chromium plated shower rose 125mm size with shower arm 15mm size and 195mm long complete all as specified and directed by Engineer-in-Charge.
S&F Chromium plated single lever basin mixer without popup waste system & 450mm long braided hoses complete all as specified and directed by Engineer-in-Charge. Make : Cat No : VGP-81011B of Jaquar or equivalent.
S&F glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long fixed with and including Chromium plated brass screws and wooden/plastic cleats etc complete all as specified and directed by Engineer-in-Charge.
S&F Chromium plated Health faucet with 1 Mtr tube and hook complete all as specified and directed by Engineer-in-Charge. Make : Cat No : ALD-579 of Jaquar or equivalent.
S&F Grating doom 100mm dia of PTMT complete all as specified and directed by Engineer-in-Charge.
S&F Grating doom 100mm dia of PTMT with waste hole complete all as specified and directed by Engineer-in-Charge.
Supply and fix stainless steel sink without draining board made out of 1.00 mm thick sheet for kitchen with plug and washers, waste pipe with cantilever brackets overall size 495mm x 420mm bowl size 410mm x 330mm x 160mmcomplete all as specified and directed by Engineer-in-Charge.
S&F pegs set of six hooks, solid body,300mm long made of aluminium body complete all as specified and directed by Engineer-in-Charge.
S&F Soap dish, any type, fixed to plugs with chromium plated brass screws complete all as specified and directed by Engineer-in-Charge.
M&L for MS rolled sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plate Fe 410-Gde-E-250 quality-A complete all as specified and directed by Engineer-in-Charge.
M&L for applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer on new steel surface exc 10cm width or girth complete all as specified and directed by Engineer-in-Charge.
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screw or L type or J type hook complete all as specified and directed by Engineer-in-Charge.
S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screw or L type or J type hook complete all as specified and directed by Engineer-in-Charge.
Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as directed.
M&L for applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer on new steel surface n.exc 10cm width or girth complete all as specified and directed by Engineer-in-Charge.
Excavating over areas, n exc1.5 m deep for septic tanks and getting out in soft/disintegrated rock complete all as specified and directed by Engineer-in-Charge.
All as per item No 113 here-in before but for depth exc 1.5 and n exc 3.0 m soft/disintegrated rock complete all as specified and directed by Engineer-in-Charge.
M&L for Precast reinforced cement concrete 1:2:4 type B-1, using 20mm graded crushed stone aggregate as in manhole cover slab, complete all as specified and directed by Engineer-in-Charge. Note : (Reinforcement shall be measured and paid separately).
M&L for mild steel TMT bars 6 to 8 mm dia and over, cut to length, bent to shape required, including cranking bending spirally for handle, rungs and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed by Engineer-in-Charge.
M&L for Concrete bed to drain pipes for 150 mm bore, laid in trenches including packing under and haunching against the side of pipes, after they are laid and tested in PCC 1:3:6 type C-2 (using 40mm graded crushed stone aggregate), complete all as specified and directed by Engineer-in-Charge.
M&L for Salt glazed stone ware pipe of 150mm bore grade 'A' laid in trenches and jointed in cement mortar, complete all as specified and directed by Engineer-in-Charge.
Rendering 15mm thick in cement mortar 1:4 mixed with water proofing compound on fair masonry surfacesand finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge..(WPC will be measured and paid seperately).
Supply only liquid waterproofing compoundcomplete all as specified and directed by Engineer-in-Charge.
M&L for Cement concrete 1:2:4 type B-1 (using 20mm graded agg) in surface channels and drains complete all as specified and directed by Engineer-in-Charge.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mi- tred/stopped ends etc.complete all as specified and directed by Engineer-in-Charge.
M & L for hardcore with broken stone or boulders n.exc 63 mm gauge , deposited , spread in layer n.exc 15 cm thick , watering and ramming to a true surface complete all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:2:4 type B-1 (using 40mm graded stone aggregate) as in foundation/mass concrete complete all as specified and directed by Engineer-in-Charge.
M & L for RCC M-25 Design mix for Slabs supported on walls, beams and comums in floors, roofs, landings, balconies, caopies, deck slabs and in design mix complete all as specified and directed by Engineer-in-Charge.
M & L for RCC M-25 Design mix Walls, retaining walls, basement walls, ballast walls any thickness above top of footing including attached pilaster and buttresses etc complete all as specified and directed by Engineer-in-Charge.
M&L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concerete railings, opening in concerete walls, floors and roof n exc 20cm wide and sides of RCC/PCC bansa in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified and directed by Engineer-in-Charge.
M & L formwork to edges to concerete flats , breaks in floors, openings in concerete walls, floors and roof ans sides of RCC/PCC bands in walls, horizontal or sloping and similar work all exceeding 20cm wide. (Where RCC/PCC band in walls, spanning and opening in concerete wall complete all as specified and directed by Engineer-in-Charge.
M & L for formwork to to faces of walls, rataining walls, abutments, parapets and staircase railings and similar woprk including attached pillasters, buttresses etc complete all as specified and directed by Engineer-in-Charge.
S&F 150 mm dia single "Y" or "T" Junction SWG drain pipes complete all as specified and directed by Engineer-in-Charge.
M & L for Loose filling with broken bricks aggregates of gauge 80 to 150 mm in soakage pits, soakage wells complete all as specified and directed by Engineer-in-Charge.
M&L for Point wiring for light/fan point complete with multi-starnded copper conductor 1.5 Sqmm size PVC insulated unseathed cable, 1100 volt grade, confirming to IS 694 & colour code in counduit system of wiring, drawn in and including medium grade PVC conduit not less than 20 mm dia concealed including cutting chases and making good disturbed surface complete, sunk in pressed steel terminal boxes of required size, of not less than 1.6 mm thick factory made and factory painted with top cover 3 mm thick plastic laminated sheet fixed with brass screw and cup washers with all accessories including single core solid copper conductor 1.5 Sqmm size solid PVC insulated unseatheds cable as earth wire to common earth dolly drawn in same conduit c complete all as specified and directed by Engineer-in-Charge.
M&L for Point wiring for 15 Amp socket complete with multi-starnded copper conductor 4 Sqmm size PVC insulated unseathed cable, 1100 volt grade, confirming to IS 694 & colour code in counduit system of wiring, drawn in and including medium grade PVC conduit not less than 20 mm dia concealed including cutting chases and making good disturbed surface complete, sunk in pressed steel terminal boxes of required size, of not less than 1.6 mm thick factory made and factory painted with top cover 3 mm thick plastic laminated sheet fixed with brass screw and cup washers with all accessories including single core solid copper conductor 4 Sqmm size solid PVC insulated unseatheds cable as earth wire to common earth dolly drawn in same conduit complete all as specified and directed by Engineer-in-Charge.
M&L for piano switch, flush type, 5 /6 Amp one way single pole complete all as specified and directed by Engineer-in-Charge.
M&L for ceilling rose 3 phase PVC/polycarbonate complete all as specified and directed by Engineer-in-Charge.
M&L for sub main wiring concealed complete with two runs of single core 10 sqmm (nominal area) 1100 volt grade single core PVC insulated unsheathed cable with multi-stranded copper conductor of FRLS grade (IS:694) drawn through and including 25mm dia non metallic rigid PVC conduit and conduit accessories concealed in walls/ roofs/ floors etc including provision of earth continuity wire with same cable as for wiring but in green colour complete all as specified and directed by Engineer-in-Charge. [Note:- M&L for cutting chases for concealed conduit wiring on any surfaces and making good disturbed surfaces to match with the existing surfaces in cement mortar (1:3) and finishing with existing finishes shall be deemed to be included in the quoted rate.]
S&F LED light fitting 4 feet 1x20 watt 6500K, 220 V AC decorative box type with ultra slim square profile LED lightining fixture with extruded polycarbonate environmental friendly with driver holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engineer-in-Charge.
S&F LED light fitting 2 feet 1x10 watt 6500 K, 220 V AC decorative box type with ultra slim square profile LED lightining fixture with extruded polycarbonate environmental friendly with driver holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engineer-in-Charge.
Supply and fix electric water heater, storage type stainless steel body with Glass lined inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostat, NRV, connection piece etc & electric supply connection and including grouting nuts & bolts of 15 mm dia 100 mm long for hanging the geysers, incl PVC connection 15mm, 450mm dia long heavy duty for hot water connection complete and plastering and finishing of plastered surface of wall as per existing surface complete all as specified and directed by Engineer-in-Charge.
S&F steel water tubing medium grade galvanised (ISI marked) with all fittings such as bends, elbow, tee, pieces connection back nuts c complete all as specified and directed by Engineer-in-Charge as folowing sizes :-
25 mm dia
20 mm dia
40 mm dia
S&F LED street light fitting 35 Watt 6500K pf >.90 efficency 100lm/W 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp fixing of wall,pole,building with impact and corrosion resistant including thermal management in multiple optics complete with IP 65 protection complete with all aceessories duly connection with three core flexible copper wire complete all as specified and directed by Engineer-in-Charge.
Supply and fix exhaust fan, steel body, heavy duty, AC single Phase, 230V of size 300m sweep with, blades, and frame and louvers other accessories including making connection from ceilling rose to exhaust fan with flexible copper conductor copper cable complete all as specified and directed by Engineer-in-Charge.
S&F street light brackket made out of 30//32 mm dia GI ligt grade tubing not less than .76 Mtr long bend to shape including pole clamp/fastern clips made out of FI and nuts, bolts and washers etc complete all as specified and directed by Engineer-in-Charge.
S&F sheet metal enclasure single pole and neutral enclosure with two pin and earth plug and socket including MCB 20 Amp complete all as specified and directed by Engineer-in-Charge.
S&F sheet steel powder coated distribution board SPN DB 8 ways double door , 220 volts, with 200 Amps rated bus bar, neutral link, earth bar, IP 43 protection and double door, IK-09 with metal door suitable for mounting MCBs complete all as specified and directed by Engineer-in-Charge.
S&F MCB SPN 63 Amp 240 volt C curve 10 KA complete all as specified and directed by Engineer-in-Charge.
S&F MCB SP 6-32 Amp 240 volt C curve 10 KA complete all as specified and directed by Engineer-in-Charge.
S&F MCB TPN 40 to 100 Amp 415 volt C curve 10 KA complete all as specified and as directed.
Supply and fix flush mounted factory made VTPN DBs, 415 volt IP - 43 protection IK-09 with metal double door with 200 Amp copper bus bar with 2 neutral bar, earth bar and cables management fully insulated bus bar with set of wire and door earthin with provision of space of 100 amps MCCB as incommer and SP/TP MCCBs as outgoing 4 way complete all as specified and directed by Engineer-in-Charge.
S&F MCCB 125 Amp, 4 pole 415 volt, 25 KA , 50 Hz complete all as specified and directed by Engineer-in-Charge.
Supply and laying in trenches / ducts, passing through pipe / fixing on poles 1100 volts grade, ISI marked of size 25 Sq.mm 3.5 core, LT cable (heavy duty), XLPE insulated served with an inner sheathing of PVC tape armoured with galvanized steel wire or tape and over all PVC sheathed with stranded aluminium conductor cable including commissioning and testing complete all as specified and directed by Engineer-in-Charge.
All as per Item No. 24 herein before but cable of size 35 sqmm, 3.5 core complete all as specified and directed by Engineer-in-Charge.
Supply, installation, testing and commissioning factory made LT feeder pillar box outdoor type, wallfloor mounted of size 1000x900x450mm suitable for 415 Volts 3 phase 4 wire system, 50 Hz supply with aluminium bus bar of rating 200 Amps for phases & neutral installed on porcelain/ epoxy insulators; control wiring with PVC insulated multi-stranded copper conductor cable 1100 V grade; the panel shall be dust proof, vermin proof (IP-54) duly powder coated, made out of 2mm thick CRCA sheet mounted on wall with suitable anchor fasteners, front openable with double shutters and locking arrangement complete all as specified including housing the following accessories: Incoming: (i) MCCB 100 Amps, 4 pole, 16 KA - 01 No (ii) Voltmeter 0-500 Volts, square flush pattern, digital type - 01 No (iii) Ammeter 0-400 Amps, square flush pattern, digital type - 01 No (iv) LED type indicating lamps RYB- 01 set (v) Alarm system to indicate the commercial power failure
M&L for earthing complete with galvanized steel earth plate (600 x 600)mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 Mtr deep below normal ground level) with top edge of plate not less than 1.5 Mtr below normal ground level connected to GI wire 4mm dia as earth lead by means of nuts/bolts and washers, check nuts and washer of galvanized iron or steel including 15 mm dia GI pipe light grade upto 1.5 mtr below ground level for protection pipe, excavation and earth work charcole dust, common salt PCC (1:3:6) type C-1 (using 20 mm graded stone aggregate) for chamber and MS angle iron frame of size (40x40x3)mm and RCC cover 40 mm thick (1:2:4) type B1 (using 20 mm graded stone aggregate) reinforced with 8 mm dia TMT bars @ 75 mm c/c both ways with MS handle 12 mm dia, round, PGI funnel and wire mesh, 20 mm dia GI pipe light grade for watering all as shown in Plate no 3 of SSR Part I of 2009 and connected to earth test point including testing complete all as specified and as directed. Note:- Cost of earthing strip & GI pipe 25mm up to 7.5 m shall be deemed to be included in cost of above item.
M&L for earthing complete with galvanized steel earth plate (600 x 600)mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 Mtr deep below normal ground level) with top edge of plate not less than 1.5 Mtr below normal ground level connected to GI strip of size 32x6mm as earth lead by means of nuts/bolts and washers, check nuts and washer of galvanized iron or steel including 15 mm dia GI pipe light grade upto 1.5 mtr below ground level for protection pipe, excavation and earth work charcole dust, common salt PCC (1:3:6) type C-1 (using 20 mm graded stone aggregate) for chamber and MS angle iron frame of size (40x40x3)mm and RCC cover 40 mm thick (1:2:4) type B1 (using 20 mm graded stone aggregate) reinforced with 8 mm dia TMT bars @ 75 mm c/c both ways with MS handle 12 mm dia, round, PGI funnel and wire mesh, 20 mm dia GI pipe light grade for watering all as shown in Plate no 3 of SSR Part I of 2009 and connected to earth test point including testing complete all as specified and as directed. Note:- Cost of earthing strip & GI pipe 25mm up to 7.5 m shall be deemed to be included in cost of above item.
S&F test point terminal block made of gun metal or phosphorus bronze size (75x75x25)mm drilled and screwed including 3 nos. 8mm dia 25mm long hex head screws for holding the bronze plate including fastening/ bolting the roof down conductor and earth electrode over the bronze plate with copper bolts & nuts of suitable size, complete all as specified and directed by Engineer-in-Charge.
S&F earth continuity conductor or main earthing 4 mm galvanised iron wire lead buried in ground, fixed to wall, any other indicated situation for loop earthing and the like up to test point on necessary insulators and fastening screws, rawl plugs complete all as specified and directed by Engineer-in-Charge.
S&F earth continuity conductor or main earthing lead aluminium strip of size 25x 3 mm buried in ground, fixed to wall, any other indicated situation for loop earthing and the like up to test point on necessary insulators and fastening screws, rawl plugs complete all as specified and directed by Engineer-in-Charge.
Supply and installed of rotationalmounded polyethene PVC water storage tank, (cylinderical vertical with closed top) hoisted & fixed in position having capacity 500 Ltr complete all as specified and directed by Engineer-in-Charge.
S&F of Gun metal glove PVC/gate valve from the pipe line and S&F gun metal glove gate valve (ISI marked) with iron wheel head,screw both ends for iron ppipe complete all as specified and directed by Engineer-in-Charge of the following sizess :-
25 mm dia
15 mm dia
M&L for plain cement concrete 1:3:6 type C2 (using 40mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:2:4 type B1 using 20mm graded stone aggregate as in coping of pole all as directed including use & waste of necessary form work all as specified and as directed.
Excavation in trenches in any type of soil not exceeding 1.5 mtr deep and not exceeding 1.5 mtr wide for laying of cables, RCC poles/stays and struts etc or /getting out cable cover and stacking for reuse/ credit , trimming sides and forming bottom surface complete all as specified and directed by Engineer-in-Charge.
M & L for Sand cushioning for appropiate level before and after laying the cable of trenches for protection of cables including punning down complete all as specified and directed by Engineer-in-Charge. Note :- Thickness of sand cushioning shall be the thickness after punning down.
M & L for sub class 'B' brick for covering to under ground cable laid flat transversally width equal to the lenth of the cable complete all as specified and directed.
RANBIR ENTERPRISES (BID ID -3305819)
rajkumar sharma (BID ID -3306345)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .