Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.7 LAccepted-AOC 011 NAGAREWADI 612 NAGAREWADI POST PADALI TALUKA SHIRUR KASAR DISTRICT BEED 413249 BEED MAHARASHTRA 413249 UDYAM MH 05 0079863 | BEED | MAHARASHTRA | 413249 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹20.5 L+₹1.3 L (6.86%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹20.5 L+₹1.3 L (6.92%)Rejected-Finance BHAVANI KRUPA GANDHI CHOWK PULGAON 442302 | WARDHA | MAHARASHTRA | 442302 | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹20.9 L+₹1.8 L (9.36%)Rejected-Finance | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹21.1 L+₹1.9 L (9.91%)Rejected-Finance | L5 | Rejected-Finance Not Lowest |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
3 Feb 2020, 6:00 pmClosed
GE PULGAON
GE PULGAON
REPAIRS REPLACEMENT OF OLD VINTAGE CI GI PIPE LINE AT PERIMETER AND DEPOT AREA UNDER GE PULGAON
2020_MES_313351_1
8774/PUL/E8
Open Tender
Civil Works
Item Rate
270 days
GE PULGAON
As per tender documents
7 documents required · 7 mandatory
₹500
Yes
GE PULGAON
₹40,000
Yes
19 Feb 2020
9 Jan 2020
5 Feb 2020
9 Jan 2020
3 Feb 2020
22 Jan 2020
9 Jan 2020 - 3 Feb 2020
Amount
Excavation in trenches, not exc. 1.5 metre wide and not exc. 1.5 metre in depth for foundation, and getting out in soft/loose soil all as specified and as directed .
Excavation in trenches, not exc. 1.5 metre wide and not exc. 1.5 metre in depth for foundation, and getting out in hard/dense soil all as specified and as directed .
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5 m in depth and getting out soft / disintegrated rock.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in any type of soil all as specified and directed .
Returning, filling in, including spreading, leveling watering and well ramming in layers of rock not exceeding 25cm.
Removing excavated material n.exc 50 metre and depositing where directed at a level not exc. 1.5 metre above the starting point of rock all as specified and as directed .
M&L for CI special/fittings suitable for CI flanged/socket ends pipe upto 100 to 150 mm bore dia such as bends, (any radius and angle), tapers any type (straight, bend, increasing, decreasing or double socket etc) tee piece, single branch 'Y' junction, double branch, cross (all flanged), collars, caps & plug, tail pieces, reducers, mechanical joint, etc. complete all as specified and as directed,
M&L for CI special/fittings suitable for CI flanged/socket ends pipe upto 200 to 300 mm bore dia such as bends, (any radius and angle), tapers any type (straight, bend, increasing, decreasing or double socket etc) tee piece, single branch 'Y' junction, double branch, cross (all flanged), collars, caps & plug, tail pieces, reducers etc. complete all as specified and as directed,
Taking up 80 mm bore old Unserviceable steel hume pipe line/CI/GI any type water mains pipes, any class, (including all fittings),disconnecting pipes and fittings all as specified and as directed.
All as per item No. 9….. but for 100 mm bore
All as per item No. 9….. but for 150 mm bore
All as per item No. 9….. but for 200 mm bore
Relaying 80 mm bore only old pipe in good condition/pipe taken out from trenches for repairs in any length including fittings etc. of size all as specified and as directed.
All as per item No. 13….. but for 100 mm bore
All as per item No. 13….. but for 150 mm bore
All as per item No. 13….. but for 150 mm bore
Supply and fix 80 mm bore cast iron pipes with spigot and socket ends centrifugally cast class LA in any length suitable for rubber tyton joint and laid in trenches as specified and as directed .
All as per item No. 17….. but for 100 mm bore
All as per item No. 17….. but for 150 mm bore
All as per item No.17….. but for 200 mm bore
M&L for Run lead joint for 80 mm bore of spigot socket cast iron pipes and fitting, including caulking properly and making joint leak proof including burning out old lead joint in position , including recovering lead all as specified and as directed.
All as per item No. 21….. but for 100 mm bore
All as per item No. 21….. but for 150 mm bore
All as per item No. 21….. but for 200 mm bore
M&L for burning out lead joint in position 80 mm bore , including removing lead to store / stacked at site to issue under credit all as specified and as directed.
All as per item No. 25….. but for 100 mm bore
All as per item No. 25….. but for 150 mm bore
All as per item No. 25….. but for 200 mm bore
Supply and fix of sluice valve 80 mm bore PN-1.0 heavy duty ISI marked as per (IS-14846) with flanged ends with 02 Nos of rubber gaskets, nut bolts and washers along with SS spindle and operating wheel of following size all as specified and as directed.
All as per item No. 29….. but for 100 mm bore
All as per item No. 29….. but for 150 mm bore
All as per item No. 29….. but for 200 mm bore
M&L for rubber tyton joints for 80 mm bore suitable for sockets and spigot CI pipes including rubber gasket for all as specified and as directed
All as per item No. 33….. but for 100 mm bore
All as per item No. 33….. but for 150 mm bore
All as per item No. 33….. but for 200 mm bore
Taking out sluice valves refacing, regrinding and refixing including Repacking stuffing box of sluice valve spindle brass including taking apart and reassembling of 300 MM complete all as specified and directed byEngineer-in-Charge.
Taking out sluice valves refacing, regrinding and refixing including Repacking stuffing box of sluice valve spindle brass including taking apart and reassembling of 200 MM complete all as specified and directed byEngineer-in-Charge.
Taking out sluice valves refacing, regrinding and refixing including Repacking stuffing box of sluice valve spindle including taking apart and reassembling of 150 MM complete all as specified and directed byEngineer-in-Charge.
M&L in repair of rusted & crack CI water branch connection 80 to 150mm dia by using mechanical joint with connecting all accessories complete all as specified and directed byEngineer-in-Charge. Note : (i) cost of gasket and nut bolts ,washers'jointing of materials as required are inclusive in above job. ii) Required T&P for job is provided by the Contractor is deemed to be included in the item rate. (iii) Excavation for pipe is included in job Work.
M&L in repair of rusted & crack CI water branch connection 200 to 300mm dia by using mechanical joint with connecting all accessories complete all as specified and directed byEngineer-in-Charge. Note : (i) cost of gasket and nut bolts ,washers'jointing of materials as required are inclusive in above job. ii) Required T&P for job is provided by the Contractor is deemed to be included in the item rate. (iii) Excavation for pipe is included in job Work.
Dismenttling / taking out existing un serviceable air valve from CI main complete and supply & fixing in repair of new cast iron air valve with 02 Nos of air- outlets 25mmand inlet 80 mm bore inlet for cast iron pipe i.e (MS Clamps with welded socket of suitable size, nut, bolt, washer, gasket including drilling and air ball) all as directed.
M&L for dismantling old wall valve chamber and construction of brick masonary new valve pit chamber of size 900mmx900mmx900mm (internal ) size 100mm thick PCC 1:4:8 type D2 lean concrete foundation using 40mm graded stone aggregate providing well burnt brick masonary wall of 23mm thick built in CM 1:6 rendering in cement 1:6 finished even smooth using extra cement internally and 20mm thick in CM 1:4 and finished fair and even supply and fix 3.15 mm thick MS sheet steel cover fixed on 50mmx50mmx6mm thick angle iron frame embeded in PCC coping with locking arrangement and 1 Nos 50mm size 4 levers lock with key in duplicate Standard size and MS hold fast and handle made out of 25 x 6mm flat iron applying two coats of synthetic enamel paint of approved shade over a coat of primer (Red Oxide) to all exposed surface making good all disturbed surface to match surrounding complete all as specified and directed.
M&L for dismantling old valve chamber and construction of brick masonarry new valve pit chamber of size 1200mmx1200mmx1200mm (internal ) size 100mm thick PCC 1:4:8 type D2 lean concrete foundation using 40mm graded stone aggregate providing well burnt brick masonary wall of 23mm thick built in CM 1:6 rendering in cement 1:6 finished even smooth using extra cement internally and 20mm thick in CM 1:4 and finished fair and even supply and fix 3.15 mm thick MS sheet steel cover fixed on 50mmx50mmx6mm thick angle iron frame embbeded in PCC coping with locking arrangement and 1 Nos 50mm size 4 levers lock with key in duplicate Standard size and MS hold fast and handle made out of 25 x 6mm flat iron appplying two coats of synthetic enamel paint of approved shade over a coat of primer (Red Oxide) to all exposed surface making good all disturbed surface to match surrounding complete all as specified and directed.
Dismantling and taking out existing sluice 80 mm Dia valve from CI pipe line by removing bolts, nuts rubber gasket, joints complete all as specified and directed.
All as per item No. 45….. but for 100 mm Dia
All as per item No. 45….. but for 150 mm bore
All as per item No. 45….. but for 200 mm bore
SHRI RANI SATI TRADERS
M/s Dara Constructions, Pulgaon
M/s MM TRADERS
I P Constructions
M/S Ramakant Chourasia
SHREE SIDDHIVINAYAK TRADERS
M/S JAI BHAWANI CONSTRUCTIONS
Bidder Name
I P Constructions
SHRI RANI SATI TRADERS
SHREE SIDDHIVINAYAK TRADERS
M/S Ramakant Chourasia
MAHARASHTRA ENTERPRISES
M/s Dara Constructions, Pulgaon
M/s MM TRADERS
M/S JAI BHAWANI CONSTRUCTIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .